Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAVITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Analysis and Control of Wakefields in X-Band Crab Cavities for Compact Linear Collider

The Compact Linear Collider requires a crab cavity on each beamline prior to the interaction point to rotate the bunches before collision. The cavities are X-band travelling wave type and are located close to the final doublet of the beam delivery system. This makes the beam very sensitive to transverse momentum imparted by wakefields; hence the wakefields must be tightly controlled. Of special concerns are the orthogonal polarization of the operating mode and the fundamental monopole mode of the crab cavity. The former mode is at the same frequency as the operating mode of a cylindrically symmetric cavity and the latter one is at a lower frequency and hence is difficult to damp using a single means. In this paper major problematic modes of the crab cavity are investigated and damping requirements for them are calculated. Possibility of meeting the required wakefield control using waveguide damping and choke damping is thoroughly investigated. As a comparison, damped-detuning is also investigated.

43 PARTICLE ACCELERATORS↗

CLIC Crab Cavity Design Optimisation for Maximum Luminosity

The bunch size and crossing angle planned for CERN's compact linear collider CLIC dictate that crab cavities on opposing linacs will be needed to rotate bunches of particles into alignment at the interaction point if the desired luminosity is to be achieved. Wakefield effects, RF phase errors between crab cavities on opposing linacs and unpredictable beam loading can each act to reduce luminosity below that anticipated for bunches colliding in perfect alignment. Unlike acceleration cavities, which are normally optimised for gradient, crab cavities must be optimised primarily for luminosity. Accepting the crab cavity technology choice of a 12 GHz, normal conducting, travelling wave structure as explained in the text, this paper develops an analytical approach to optimise cell number and iris diameter.

43 PARTICLE ACCELERATORS↗

Design and Development of Superconducting Parallel-Bar Deflecting/Crabbing Cavities

The superconducting parallel-bar cavity is a deflecting/crabbing cavity with attractive properties that is being considered for a number of applications. We present the designs of a 499 MHz deflecting cavity developed for the Jefferson Lab 12 GeV Upgrade and a 400 MHz crabbing cavity for the LHC High Luminosity Upgrade. Prototypes of these two cavities are now under development and fabrication.

43 PARTICLE ACCELERATORS↗

Automated Hydroforming of Seamless Superconducting RF Cavity

We are studying the possibility of automated hydroforming process for seamless superconducting RF cavities. Preliminary hydroforming tests of three-cell cavities from seamless tubes made of C1020 copper have been performed. The key point of an automated forming is to monitor and strictly control some parameters such as operation time, internal pressure and material displacements. Especially, it is necessary for our studies to be able to control axial and radial deformation independently. We plan to perform the forming in two stages to increase the reliability of successful forming. In the first stage hydroforming by using intermediate constraint dies, three-cell cavities were successfully formed in less than 1 minute. In parallel, we did elongation tests on cavity-quality niobium and confirmed that it is possible to achieve an elongation of >64% in 2 stages that is required for our forming of 1.3 GHz cavities.

36 MATERIALS SCIENCE↗

Commissioning results of Nb 3 Sn cavity vapor diffusion deposition system at JLab

Nb 3 Sn as a BCS superconductor with a superconducting critical temperature higher than that of niobium offers potential benefit for SRF cavities via a lower-than-niobium surface resistance at the same temperature and frequency. A Nb 3 Sn vapor diffusion deposition system designed for coating of 1.5 and 1.3 GHz single-cell cavities was built and commissioned at JLab. As the part of the commissioning, RF performance at 2.0 K of a single-cell 1.5 GHz CEBAF-shaped cavity was measured before and after coating in the system. Before Nb 3 Sn coating the cavity had a Q 0 of about 10 10 and was limited by the high field Q-slope at E acc ≅ 27 MV/m. Coated cavity exhibited the superconducting transition at about 17.9 K. The low-field quality factor was about 5∙10 9 at 4.3 K and 7∙10 9 at 2.0 K decreasing with field to about 1∙10 9 at E acc ≅ 8 MV/m at both temperatures. The highest field was limited by the available RF power.

36 MATERIALS SCIENCE↗

Experiment and Results on Plasma Etching of SRF cavities

The inner surfaces of SRF cavities are currently chemically treated (etched or electropolished) to achieve the state of the art RF performance. We designed an apparatus and developed a method for plasma etching of the inner surface for SRF cavities. The process parameters (pressure, power, gas concentration, diameter and shape of the inner electrode, temperature and positive dc bias at inner electrode) are optimized for cylindrical geometry. The etch rate non-uniformity has been overcome by simultaneous translation of the gas point-of-entry and the inner electrode during the processing. A single cell SRF cavity has been centrifugally barrel polished, chemically etched and RF tested to establish a baseline performance. This cavity is plasma etched and RF tested afterwards. The effect of plasma etching on the RF performance of this cavity will be presented and discussed.

43 PARTICLE ACCELERATORS↗

New results of development on high efficiency high gradient superconducting rf cavities

We report on the latest results of development on high-efficiency high-gradient superconducting radio frequency (SRF) cavities. Several 1-cell cavities made of large-grain niobium (Nb) were built, processed and tested. Two of these cavities are of the Low Surface Field (LSF) shape. Series of tests were carried out following controlled thermal cycling. Experiments toward zero-field cooling were carried out. The best experimentally achieved results are E acc = 41 MV/m at Q 0 = 6.5×10 10 at 1.4 K by a 1-cell 1.3 GHz large-grain Nb TTF shape cavity and E acc = 49 MV/m at Q 0 = 1.5×10 10 at 1.8 K by a 1-cell 1.5 GHz large-grain Nb CEBAF upgrade low-loss shape cavity.

43 PARTICLE ACCELERATORS↗

Mechanical Properties of Niobium Cavities

The mechanical stability of bulk Nb cavity is an important aspect to be considered in relation to cavity material, geometry and treatments. Mechanical properties of Nb are typically obtained from uniaxial tensile tests of small samples. In this contribution we report the results of measurements of the resonant frequency and local strain along the contour of single-cell cavities made of ingot and fine-grain Nb of different purity subjected to increasing uniform differential pressure, up to 6 atm. Measurements have been done on cavities subjected to different heat treatments. Good agreement between finite element analysis simulations and experimental data in the elastic regime was obtained with a single set of values of Young’s modulus and Poisson’s ratio. The experimental results indicate that the yield strength of medium-purity ingot Nb cavities is higher than that of fine-grain, high-purity Nb.

36 MATERIALS SCIENCE↗

Temperature Mapping of Nitrogen-doped Niobium Superconducting Radiofrequency Cavities

It was recently shown that diffusing nitrogen on the inner surface of superconducting radiofrequency (SRF) cavities at high temperature can improve the quality factor of the niobium cavity. However, a reduction of the quench field is also typically found. To better understand the location of rf losses and quench, we used a thermometry system to map the temperature of the outer surface of ingot Nb cavities after nitrogen doping and electropolishing. Surface temperature of the cavities was recorded while increasing the rf power and also during the quenching. The results of thermal mapping showed no precursor heating on the cavities and quenching to be ignited near the equator where the surface magnetic field is maximum. Hot-spots at the equator area during multipacting were also detected by thermal mapping.

43 PARTICLE ACCELERATORS↗

Microwave Cavity Simulation Using Ansys HFSS

The design of microwave cavity detectors for axion dark matter research is often accomplished using advanced full-wave electromagnetic simulation software tools. These tools provide a cost-effective approach to evaluate a wide variety of cavity configurations, frequency tuning mechanisms, and conductive or dielectric materials and coatings. One simulation software package used for this application is Ansys High Frequency Structure Simulator (HFSS), which is based upon the well-established finite element method. HFSS includes numerous features useful for microwave cavity design such as parametric geometry modeling, adaptive meshing algorithm, curvilinear mesh elements, driven modal and eigenmode matrix solvers, and optimization algorithms. This paper describes the use of the HFSS software to simulate microwave cavities for axion haloscope detectors, with an example tutorial for a cylindrical cavity. Excellent agreement between the simulated and analytical results is shown for the resonant frequency, quality factor, and form factor.

Ansys HFSS, Cavity simulation, finite element mode↗

Performance of a 1.3 GHZ Normal-Conducting 5-Cell Standing-Wave Cavity

A 5-cell, normal-conducting, 1.3 GHz, standing-wave (SW) cavity was built as a prototype capture accelerator for the ILC positron source. Although the ILC uses predominantly superconducting cavities, the capture cavity location in both a high radiation environment and a solenoidal magnetic field requires it to be normal conducting. With the relatively high duty ILC beam pulses (1 msec at 5 Hz) and the high gradient required for efficient positron capture (15 MV/m), achieving adequate cavity cooling to prevent significant detuning is challenging. This paper presents the operational performance of this cavity including the processing history, characteristics of the breakdown events and the acceleration gradient witnessed by a single bunch at different injection times for different rf pulse lengths.

43 PARTICLE ACCELERATORS↗

New Accessory for Cleaning the Inside of the Machine Tool Cavity

The best way to extend the life of a metalworking fluid (MWF) is to make sure the machine tool and MWF delivery system are properly cleaned at least once per year. The dilemma the MWF manager is faced with is: How does one clean the machine tool and the MWF system on a large machine tool with an enclosure in a timely manner without impacting production schedules? Remember the walls and roof of the machine enclosure are coated with a film of dried contaminated MWF that must also be removed. If not removed, the deposits on these surfaces can recontaminate the fresh charge of MWF. I have found a product that with this revised procedure helps to shorten the machine tool down time involved with machine cleaning. (1) Discuss with your MWF supplier if they have a machine cleaning product that can be used with your current water based MWF during normal machining operations. Most MWF manufacturers have a machine cleaner that can be used at a lower concentration (1-2% vs. 5%) and can be used while still making production parts for a short period of time (usually 24-48 hours). (2) Make sure this machine cleaner is compatible with the work-piece material you are machining into product. Most cleaners are compatible with ferrous alloys. Because of the increased alkalinity of the fluid you might experience staining if you are machining copper or aluminum alloys. (3) Remove the chips from the chips pans and fluid channels. (4) During off shift hours circulate the MWF using a new product marketed by Rego-Fix called a 'Hydroball'. This device has a 5/8 inch diameter straight shank which allows it to be installed in any collet or solid quick change tool holder. It has multiple nozzles so that the user can control the spray pattern generated when the MWF is circulated. It allows the user to utilize the high pressure, through spindle MWF delivery capability of your machine tool for cleaning purposes. The high pressure MWF system can now be effectively used for cleaning purposes. This will also work with standard pressure system but you must reduce the number of nozzles utilized. By combining the movement of the machine axis around the operating envelope and the MWF circulation you can do a reasonably effective job of washing the inside of the machine tool operating cavity. Way covers will be moved and surfaces exposed because of axis movement. Spray direction will change to better wash fixtures and machine tool components. Deposits will start to breakdown and be washed into the machine tool sump. Since the cycle will run four or more hours it can be done with a weaker cleaning solution. The distributor states that the unit can be rotated up to 50 RPM. When running it has the same effect as the washing rotor inside of your home dishwasher. Inside the cavity on a machining center there is a lot of splash. During normal operations, MWF deposits buildup on the walls and roof of the enclosures. If these deposits (containing bacteria, mold and other contaminants) are not removed they will inoculate the fresh charge of MWF when they are resaturated. When you clean the inside of machine tool cavity, time is spent removing these deposits on the walls and roof of the enclosure. Getting to these surfaces is very difficult usually requiring that a member of the cleaning crew get inside the machine tool to reach them. The Hydro ball is effective in distributing the cleaning solution on all surfaces of the enclosure under high pressure. The only negative we have found is you get to find all the gaps and leaks in your machine tool enclosure. By running the hydro ball with the machine cleaner enriched MWF during off shift (4-8 hours) you can effectively remove these deposits and buildups on the internal surfaces of the cavity of the machine tool and wash them down into the sump. You also clean the internal components of the MWF system without interrupting normal scheduled work. (5) Pump out the spent MWF. You will have found that most of the deposits have been washed from the internal surfaces of the enclosure. For extremely dirty machines you might have to refill the machine tool with the normal machine cleaner mix. You will find that even heavy deposits will break down quicker because of this pre-wash cycle. (6) Rinse the machine cavity. (7) Clean the walls, bottom and screens in the MWF reservoir. The use of this tool and the dilute machine cleaner reduced the cleaning time considerately without affecting production schedules. (8) Refill with MWF and resume normal operations. What we like about this system is we can schedule these light cleanings just before a scheduled fluid change. Add the cleaner to the mix and run the Hydroball on second shift. The spent fluid is pumped out on third shift and the machine refilled. The machine tool with a fresh charge of MWF is ready for first shift without interrupting production schedules. We get better life from our MWFs and the machinists are happier about the condition of their machines.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preliminary Results from Multi-cell seamless niobium cavities fabricated by hydroforming

The technology of forming multi-cell seamless niobium cavities has been developed at DESY within the European CARE (Coordinated Accelerator Research in Europe) program. Three-cell units have been manufactured successfully and a 9-cell cavity has recently been completed from three sub-sections and has been successfully tested at DESY. Additionally, we have equipped two 3-cell units one center unit of a 9-cell cavity and one end-unit with niobium beam pipes, have tuned these units and carried out cryogenic radio-frequency (RF) tests after standard BCP surface treatments had been applied to these cavities. In addition, we have taken temperature maps with JLab s two-cell thermometry system to compare with standard electron-beam welded cavities. This contribution will report about the preliminary cryogenic test results and the T-mapping this is an ongoing investigation.

43 PARTICLE ACCELERATORS↗

A 3-cell deflecting rf cavity for emittance exchange experiment at ANL.

An RF deflecting structure has been designed and fabricated for a transverse-to-longitudinal emittance exchange experiment at Argonne National Laboratory (ANL) [Y.-E. Sun, et al., Design study of a transverse-to-longitudinal emittance exchange proof-of-principle experiment, in: Proceedings of PAC-2007, Albuquerque, NM, USA, 2007, pp. 3441-3443]. The structure is a 1300 MHz normal conducting RF cavity consisting of three cells operating in a dipole (TM{sub 110}-like) mode. As high as 3.4 MV deflecting voltage is required for the experiment. In this paper, we present detailed RF design of the cavity, particle tracking simulations in the cavity and low power RF measurement results in comparison with numerical simulations. The cavity cell geometries (gaps in particular) are optimized to giving a zero orbit offset for particles crossing the cavity with zero-phase.

43 PARTICLE ACCELERATORS↗

Beam-induced Electron Loading Effects in High Pressure Cavities for a Muon Collider

Ionization cooling is a critical building block for the realization of a muon collider. To suppress breakdown in the presence of the external magnetic field, an idea of using an RF cavity filled with high pressure hydrogen gas is being considered for the cooling channel design. One possible problem expected in the high pressure RF cavity is, however, the dissipation of significant RF power through the beam-induced electrons accumulated inside the cavity. To characterize this detrimental loading effect, we develop a simplified model that relates the electron density evolution and the observed pickup voltage signal in the cavity, with consideration of several key molecular processes such as the formation of the polyatomic molecules, recombination and attachment. This model is expected to be compared with the actual beam test of the cavity in the MuCool Test Area (MTA) of Fermilab.

43 PARTICLE ACCELERATORS↗

The RF performance of cavity made from defective niobium material determined by Eddy Current Scanning

Eddy current scanning (ECS) has been used to screen niobium sheets to avoid defective material being used in costly cavity fabrication. The evaluation criterion of this quality control tool is not well understood. Past surface studies showed some features were shallow enough to be removed by chemical etching. The remaining features were identified to be small number of deeper inclusions, but mostly unidentifiable features (by chemical analysis). A real cavity made of defective niobium material has been tested. The cavity achieved high performance with comparable results to the cavities made from defect free cavities. Temperature mapping could help to define the control standard clearly.

43 PARTICLE ACCELERATORS↗

Detailed Simulations of a Three-Stage Supercritical Carbon Dioxide Axial Compressor with a Focus on the Shrouded Stator Cavities Flow

This paper describes the findings of detailed simulations performed to investigate the impact of seal teeth cavity leakage flow on the aerodynamic and thermal performance of a three-stage supercritical CO 2 axial compressor. The study compares a shrouded stator configuration (with cavities) to a cantilevered stator configuration (without cavities) to highlight their differences. High-fidelity computational fluid dynamics simulations were performed using non-linear harmonic (NLH) and mixing plane assumptions, considering various possible rotor/stator interface configurations for mixing plane calculations. The key performance parameters for each case were compared, and the best-performing configuration selected for further analysis. The individual stage performance parameters are also examined and compared between the cantilevered and shrouded configurations. It was observed that in the shrouded case, the leakage flow enters the cavity downstream of the stator trailing edge and gets entrained into the primary flow upstream of the stator, leading to boundary layer changes at the hub and degradation of stator and downstream rotor performance. Vortical flow structures were also observed in the stator wells, which tended to change the flow angles around the region, thereby affecting mixing and velocity distribution, resulting in a slight deterioration of compressor performance. Additionally, the study examines windage heating due to shear work from rotating walls, including the seal teeth surface. The amount of shear work done on the leakage flow and the corresponding rise in fluid temperature were quantified, tabulated, and further compared with a simple analytical model, showing good agreement between them and, hence, validating the numerical approach used.

42 ENGINEERING↗

Proton Beam Therapy for Unresectable Malignancies of the Nasal Cavity and Paranasal Sinuses

Purpose: The cure rate for unresectable malignancies of the nasal cavity and paranasal sinuses is low. Because irradiation with proton beams, which are characterized by their rapid fall-off at the distal end of the Bragg peak and sharp lateral penumbra, depending on energy, depth, and delivery, provide better dose distribution than X-ray irradiation, proton beam therapy (PBT) might improve treatment outcomes for conditions located in proximity to risk organs. We retrospectively analyzed the clinical profile of PBT for unresectable malignancies of the nasal cavity and paranasal sinuses. Methods and Materials: We reviewed 39 patients in our database fulfilling the following criteria: unresectable malignant tumors of the nasal cavity, paranasal sinuses or skull base; N0M0 disease; and treatment with PBT (>60 GyE) from January 1999 to December 2006. Results: Median patient age was 57 years (range, 22-84 years); 22 of the patients were men and 17 were women. The most frequent primary site was the nasal cavity (n = 26, 67%). The local control rates at 6 months and 1 year were 84.6% and 77.0%, respectively. With a median active follow-up of 45.4 months, 3-year progression-free and overall survival were 49.1% and 59.3%, respectively. The most common acute toxicities were mild dermatitis (Grade 2, 33.3%), but no severe toxicity was observed (Grade 3 or greater, 0%). Five patients (12.8%) experienced Grade 3 to 5 late toxicities, and one treatment-related death was reported, caused by cerebrospinal fluid leakage Grade 5 (2.6%). Conclusion: These findings suggest that the clinical profile of PBT for unresectable malignancies of the nasal cavity and paranasal sinuses make it is a promising treatment option.

62 RADIOLOGY AND NUCLEAR MEDICINE↗