Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAPACITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Study of advanced system for position location and navigation

Concepts are investigated for improving location precision and system capacity relative to current satellite based data collection and location systems. The TRILOC concept provides either or both improvements in location and system capacity by utilizing three measurements acquired during a single transmission from a platform for location purposes. The location algorithm is developed, and range differences are measured onboard the satellite. An error analysis then relates platform location errors to the precision with which the measurements are made. The second concept is to increase system capacity by means of directive antennas onboard the satellite for reducing interference and/or reducing platform power. The potential advantages and disadvantages of both sweeping and fixed directive antennas for random access systems are evaluated.

Source record↗

Experimental investigation and model development of the Skylab ATM secondary nickel-cadmium batteries

The performance of a Ni-Cd battery was evaluated and the cyclic battery controls to be used on the ATM batteries were determined. Cell and battery performance models were developed which to predict the performance of the secondary Ni-Cd batteries on the ATM. Capacity degradation and charge acceptance characteristics were considered. Mathematical models for each of these operating areas were developed based on data from two separate test programs. The capacity degradation model describes the expected usable battery capacity as a function of time, temperature, and depth-of-discharge. The charge acceptance model describes the cell charge acceptance as a function of charge rate, temperature, and state of charge. The models were designed for computer use and to facilitate possible battery modification. They can be used to predict expected performance or to compare real time performance during flight.

Kirsch, W. W.↗

Helium refrigerator

An improved helium refrigerator of the type which includes a plurality of counter-flow heat exchangers and has a maximum reserve cooling capacity when the final or low-temperature heat exchanger is substantially filled with liquid helium, and a minimum reserve cooling capacity when the low-temperature heat exchanger is substantially filled with gas. An electrical bridge circuit including a pair of temperature responsive resistors is mounted on the low-temperature heat exchanger for providing a continuous indication of the reserve cooling capacity of the refrigerator.

Ervin R Wiebe↗

Amplitude effects on the dynamic performance of a hydrostatic gas thrust bearing

The Reynolds' equation is applied to a strip gas thrust bearing to analyze amplitude disturbance effects on its dynamic performance. The Reynolds' equation is numerically approximated using finite difference techniques. The time dependent load carrying capacity is represented by a Fourier series up to and including the third harmonics. Design curves for the load capacity and the linear stiffness and damping are presented as a function of inlet location, restrictor coefficient, supply pressure, amplitude of oscillation, and squeeze number. For the range of amplitudes investigated the dimensionless load capacity, stiffness and damping does not exhibit an appreciable change in magnitude; thus, only one design curve is needed to represent each relationship. A design methodology is presented.

Stiffler, A. K.↗

Life capability of the silver electrode in alkaline electrochemical cells

Estimates of silver electrode degradation rates were made by comparing the recently measured capacities with the reported early life capacities. Chemical analyses were carried out to determine the extent of silver loss from the electrode and its distribution throughout the cell components. The results established that the silver electrode is very stable when stored at reduced temperatures in the range of 0 to -51 C, in which it exhibits a permanent degradation in capacity of 0.5%/year. The results also indicated that the silver electrode is not quite as stable when operated and stored at room temperature, where it exhibits permanent degradation in the range of 3% to 14%/year. These results were employed in predicting the life capability of the proposed new Ag-H2 cell and also in assessing the merits of employing silver electrodes in long-life probe batteries.

Frank, H. A.↗

Pulmonary function evaluation during the Skylab and Apollo-Soyuz missions

Previous experience during Apollo postflight exercise testing indicated no major changes in pulmonary function. Pulmonary function has been studied in detail following exposure to hypoxic and hyperoxic normal gravity environments, but no previous study has reported on men exposed to an environment that was both normoxic at 258 torr total pressure and at null gravity as encountered in Skylab. Forced vital capacity (FVC) was measured during the preflight and postflight periods of the Skylab 2 mission. Inflight measurements of vital capacity (VC) were obtained during the last 2 weeks of the second manned mission (Skylab 3). More detailed pulmonary function screening was accomplished during the Skylab 4 mission. The primary measurements made during Skylab 4 testing included residual volume determination (RV), closing volume (CV), VC, FVC and its derivatives. In addition, VC was measured in flight at regular intervals during the Skylab 4 mission. Vital capacity was decreased slightly (-10%) in flight in all Skylab 4 crewmen. No major preflight-to-postflight changes were observed. The Apollo-Soyuz Test Project (ASTP) crewmen were studied using equipment and procedures similar to those employed during Skylab 4. Postflight evaluation of the ASTP crewmen was complicated by their inadvertent exposure to nitrogen tetroxide gas fumes upon reentry.

Sawin, C. F.↗

Effects of water immersion to the neck on pulmonary circulation and tissue volume in man

A rapid noninvasive breathing method is used to obtain serial measurements of the pulmonary capillary blood flow, diffusing capacity per unit of alveolar volume, combined pulmonary tissue plus capillary volume, functional residual capacity, and oxygen consumption in five normal subjects undergoing 6 h of sitting, 4 h of sitting while immersed to the neck in thermoneutral water, and 4 h of lying in thermoneutral water to the neck. The rebreathing method employed a test gas mixture containing 0.5% C2H2, 0.3% C(18)O, 10% He, 21% O2, and balance N2. It is shown that immersion to the neck in the seated posture results in significant increases in sodium excretion cardiac output, and diffusing capacity per unit of alveolar volume. The pulmonary tissue plus capillary volume did not change, demonstrating that the central vascular engorgement induced by water immersion is not accompanied by significant extravasation of fluid into the pulmonary interstitial space.

Begin, R.↗

Measured performance of a 3 ton LiBr absorption water chiller and its effect on cooling system operation

A three ton lithium bromide absorption water chiller was tested for a number of conditions involving hot water input, chilled water, and the cooling water. The primary influences on chiller capacity were the hot water inlet temperature and the cooling water inlet temperature. One combination of these two parameters extended the output to as much as 125% of design capacity, but no combination could lower the capacity to below 60% of design. A cooling system was conceptually designed so that it could provide several modes of operation. Such flexibility is needed for any solar cooling system to be able to accommodate the varying solar energy collection and the varying building demand. It was concluded that a three-ton absorption water chiller with the kind of performance that was measured can be incorporated into a cooling system such as that proposed, to provide efficient cooling over the specified ranges of operating conditions.

Namkoong, D.↗

Thermodynamic property determination in low gravity

Techniques for determining heat capacities and other properties of molten metals were investigated and critically evaluated. Precisely determining heat capacities calorimetrically in space poses several problems. The weight of a drop calorimeter block along with the necessity of obtaining a large number of data points tend to make traditional approaches appear infeasible. However, for many substances exhibiting sufficiently high thermal conductivities and with known emissivities, it appears possible to investigate their properties by observing the rate of cooling of a levitated sphere which is initially at a uniform temperature above the melting point. A special advantage of the levitation method is that considerable supercooling is expected, making the study of the heat capacities of molten metals both above and below their melting points possible.

Margrave, J. L.↗

Evaluation of selected chemical processes for production of low-cost silicon, phase 2

Potential designs for an integrated fluidized-bed reactor/zinc vaporizer/SiCl4 preheater unit are being considered and heat-transfer calculations have been initiated on versions of the zinc vaporizer section. Estimates of the cost of the silicon prepared in the experimental facility have been made for projected capacities of 25, 50, 75, and 100 metric ton of silicon. A 35 percent saving is obtained in going from 25 metric ton/year to the 50 metric ton/year level. This analysis, coupled with the recognition that use of two reactors in the 50 metric ton/year version allows for continued operation (at reduced capacity) with one reactor shut down, has resulted in a recommendation for adoption of an experimental facility capacity of 50 metric ton/year or greater. At this stage, the change to a larger size facility would not increase the design costs appreciably. In the experimental support program, the effects of seed bed particle size and depth were studied, and operation of the miniplant with a new zinc vaporizer was initiated, revealing the need for modification of the latter.

Blocher, J. M., Jr.↗

Linear feedback rate bounds for regressive channels

Bounds for the linear feedback capacity of m-th order Gaussian autoregressive channels are derived. The upper bound is tighter than that found by Tiernan and Schalwijk (1974) for the feedback capacity of a first-order autoregressive Gaussian channel with not necessarily linear processing. The separation between the upper and lower bounds is small, and it is conjectured that the lower bound converges to the feedback capacity of the first-order channel as the number of signals tends to infinity.

Butman, S. A.↗

Measured performance of a 3-ton LiBr absorption water chiller and its effect on cooling system operation

A 3-ton lithium bromide absorption water chiller was tested for a number of conditions involving hot-water input, chilled water, and the cooling water. The primary influences on chiller capacity were the hot water inlet temperature and the cooling water inlet temperature. One combination of these two parameters extended the output to as much as 125% of design capacity, but no combination could lower the capacity to below 60% of design. A cooling system was conceptually designed so that it could provide several modes of operation. Such flexibility is needed for any solar cooling system to be able to accommodate the varying solar energy collection and the varying building demand. It is concluded that a 3-ton absorption water chiller with the kind of performance that was measured can be incorporated into a cooling system such as that proposed, to provide efficient cooling over the specified ranges of operating conditions.

Namkoong, D.↗

Characterization of degraded nickel cadmium cells

Various cells were cycled until degradation and then tested to determine the electrochemical characterization of the cells with regard to charge control. A constant voltage charged to a temperature-biased voltage, using up to an 8-voltage limit was used for the evaluation. Graphs show severe discharge voltage degradation with cycling and periodic capacity discharge; voltage extremes for cells with and without periodic capacity discharges; voltage extremes for cells with high rate discharge; voltage-temperature levels used for charge control; end of charge current and discharge voltage for 5 percent DOD cycling; cell capacity following 5 percent DOD cycling; and the end of discharge voltage and typical charge current profiles for the 20 percent DOD cycling.

Gross, S.↗

Evaluation program for secondary spacecraft cells: Initial evaluation tests of General Electric Company 40.0 ampere-hour nickel-cadmium spacecraft cells for the tracking data relay satellite system

Five cells provided by NASA's Goddard Space Flight Center were evaluated at room temperature and pressure (25 C plus or minus 2 C) with discharges at the 2 hour rate. Measurements of the cell containers following test, indicated an average increase of .006 inches at the plate thickness. Average end of charge voltages and pressures, and capacity output in ampere hours were determined. Three cells exceeded the voltage requirements of 1.52 volts during both c/10 charges at 20 C. All cells exceeded the voltage requirement of 1.52 volts during the 0 C overcharge test, although their end charges were below 1.50 volts. The pressure requirement of 65 psia was exceeded by both pressure transducer cells during c/10 charges at 25 C and 20 C and also during the 0 C overcharge test. The cells with pressure transducers reached a pressure of 20 psia before reaching the voltage limit of 1.550 volts during the pressure versus capacity test, and exhibited a pressure decay of 2 psia during the last 30 minutes of the 1 hour open circuit stand. Average capacity was 51.3 ampere hours.

Harkness, J. D.↗

Physical exercises on a bicycle-ergometer and running track to prevent hypodynamia in workers of intellectual labor

A program of exercises was developed and tested, consisting of a 12 minute session on a variable load bicycle ergometer and a 10-11 min. run with brief stretching and resting sessions between. Physical performance capacity was measured before, during, and after the period of the experiment and physical exams conducted. After a 4 month test period involving 30 men, aged 25-35, the program was found to be successful in increasing physical performance capacity. The PWC170 increased an average of 22 percent and maximum oxygen consumption 14 percent. Arterial pressure dropped (120/75 to 114/68), vital capacity of lungs increased by 6 percent, strength of respiratory muscles by 8.8 percent, duration of respiratory delay by 18 percent. Duration of cardiac cycles increased, stress index decreased. Cardiac contraction rate 2 minutes after work on the ergometer decreased from 118 to 102 bt/min.

Vasilyeva, V. V.↗

A high performance cocurrent-flow heat pipe for heat recovery applications

By the introduction of a plate-and-tube separator assembly into a heat pipe vapor core, it has been demonstrated that axial transport capacity in reflux mode can be improved by up to a factor of 10. This improvement is largely the result of eliminating the countercurrent shear that commonly limits reflux heat pipe axial capacity. With benzene, axial heat fluxes up to 1800 W/sq cm were obtained in the temperature range 40 to 80 C, while heat flux densities up to 3000 W/sq cm were obtained with R-11 over the temperature range 40 to 80 C. These very high axial capacities compare favorably with liquid metal limits; the sonic limit for liquid sodium, for example, is 3000 W/sq cm at 657 C. Computational models developed for these cocurrent flow heat pipes agreed with experimental data within + or - 25%.

Saaski, E. W.↗

High-performance heat pipes for heat recovery applications

Methods to improve the performance of reflux heat pipes for heat recovery applications were examined both analytically and experimentally. Various models for the estimation of reflux heat pipe transport capacity were surveyed in the literature and compared with experimental data. A high transport capacity reflux heat pipe was developed that provides up to a factor of 10 capacity improvement over conventional open tube designs; analytical models were developed for this device and incorporated into a computer program HPIPE. Good agreement of the model predictions with data for R-11 and benzene reflux heat pipes was obtained.

Saaski, E. W.↗

Solar heated fluidized bed gasification system

A solar-powered fluidized bed gasification system for gasifying carbonaceous material is presented. The system includes a solar gasifier which is heated by fluidizing gas and steam. Energy to heat the gas and steam is supplied by a high heat capacity refractory honeycomb which surrounds the fluid bed reactor zone. The high heat capacity refractory honeycomb is heated by solar energy focused on the honeycomb by solar concentrator through solar window. The fluid bed reaction zone is also heated directly and uniformly by thermal contact of the high heat capacity ceramic honeycomb with the walls of the fluidized bed reactor. Provisions are also made for recovering and recycling catalysts used in the gasification process. Back-up furnace is provided for start-up procedures and for supplying heat to the fluid bed reaction zone when adequate supplies of solar energy are not available.

Qader, S. A.↗