Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bed”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Porosity Determination and Classification of Laser Powder Bed Fusion AlSi10Mg Dogbones Using Machine Learning [Slides]

Angular pores (lack of fusion) pores are more detrimental to the health of the part due to induced stress concentrations. Three types of porosity found in AM parts: keyhole porosity, gas porosity, and lack of fusion porosity. In this research, we address the question, "Which machine learning and/or machine vision techniques work best to segment porosity and determine the type of porosity observed in the sample?"

42 ENGINEERING↗

CFD Simulation of Biomass Pyrolysis Vapor Upgrading over a Pt/TiO 2 Catalyst in Fixed and Moving Beds

This report presents a comprehensive computational fluid dynamics (CFD) study of the biomass pyrolysis vapor phase upgrading and the catalyst regeneration in different reactors under various operational conditions. This study used the open-source software Multiphase Flow with Interphase eXchanges (MFiX), developed at National Energy Technology Laboratory (NETL) for simulating hydrodynamics, heat transfer, and chemical reactions in multiphase systems. This simulation solved the conservation of mass, momentum, energy, species for gas and solid phases with chemical reactions.

09 BIOMASS FUELS↗

Performance Evaluation of a Prototype Moving Packed-Bed Particle/sCO 2 Heat Exchanger

Particle heat exchangers are a critical enabling technology for next generation concentrating solar power (CSP) plants that use supercritical carbon dioxide (sCO 2 ) as a working fluid. This report covers the design, manufacturing and testing of a prototype particle-to-sCO 2 heat exchanger targeting thermal performance levels required to meet commercial scale cost targets. In addition, the the design and assembly of integrated particle and sCO 2 flow loops for heat exchanger performance testing are detailed. The prototype heat exchanger was tested to particle inlet temperatures of 500 °C at 17 MPa which resulted in overall heat transfer coefficients of approximately 300 W/m 2 -K at the design point and cases using high approach temperature with peak values as high as 400 W/m 2 -K

14 SOLAR ENERGY↗

Progress Towards a Titanium-Zirconium-Molybdenum Alloy Coreblock Prototype Using Powder Bed Fusion

Microreactor designs make use of a coreblock for structural stability allowing for these devices to provide powder generation while being portable and inherently safe. In order to maximize energy output of the microreactors, materials must be able to withstand high temperature without melting and without substantial decreases in mechanical properties. As simultaneous projects looking at steels, graphite, and other materials are on-going, this work package will investigate titanium – zirconium – molybdenum alloy (TZM) as it allows for potentially higher microreactor operating temperatures than traditional reactor materials such as stainless steel. Notably, this alloy was developed in the 1960s for use in rockets and has a very high melting point (2623°C) but is difficult to form, machine and join. With limited needs in aerospace, literature is appropriately sparce in looking at the AM of TZM (examples include [1,2]). However, the properties appear to be an excellent match for the needs of the microreactor coreblock leading to the current project. In addition, small washers form the bulk of TZM parts needed in aerospace while the microreactor community was looking at larger, more complex parts. Therefore, AM of TZM is being explored to enable near – net shape of components with the needed complexity to impact the nuclear energy field.

36 MATERIALS SCIENCE↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a pixelated BaF 2 test bed for timing applications [Slides]

BaF 2 one of the fastest known scintillators, emitting at 195 & 220 nm with sub-nanosecond decay constant. Fast emission only comprises ~13% of total light. The goal is to develop a prototype BaF 2 detector system with a practical form factor and variable geometry, and characterize system performance for various timing applications.

42 ENGINEERING↗