Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Beam Optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Interferometer for Testing in Vibration Environments

Temporal phase shifting interferometers require a stable environment during the data acquisition, so that well controlled phase steps can be introduced between successively acquired interferograms. In contrast, single-frame interferometers need to acquire only one interferogram to provide a phase map with very good precision at high spatial resolution. Thus these interferometers are well suited for the interferometric testing of large optics with long radius of curvature for which vibration isolation is difficult, eg. testing astronomical telescope mirrors in a test tower, or testing space optics inside a cryogenic vacuum chamber. This paper describes the Instantaneous Phase Interferometer (IPI) by ADE Phase Shift, together with measurement results at NASA. The IPI consists of a polarization Twyman-Green interferometer operating at 632.8 nm, with single-frame data acquisition based on a spatial carrier technique. The spatial carrier fringes are generated by introducing large amount of tilt between the test beam and the reference beam. The phase information of the optical surface under test is encoded in the straightness of the interference fringes, which can be detected in a single frame with spatial sampling of 1000 x 1000 pixels. Measurements taken at the NASA Marshall Space Flight Cater in support of the characterization of developmental optics for the Next Generation Space Telescope are presented. Such tests consist of a mirror placed inside a cryogenic vacuum chamber, with the IPI placed outside the test chamber without any additional vibration isolation.

Eng, Ron↗

CODEX Optical Design and Alignment

The COronal Diagnostic EXperiment (CODEX) is a Heliophysics mission to measure the density, temperature, and velocity of the electrons in the solar corona with the primary goal of improving our understanding of the physical conditions of the solar wind in the acceleration region. The temperature and velocity measurement requires much higher signal-to-noise ratio than the density measurements. In solar coronagraphs, the diffraction of the solar disk light due to the occulting element is the dominant source of noise. Therefore, to further suppress the diffracted sun light with respect to the existing coronagraphs is a critical element of the CODEX design. To minimize the stray light due to diffraction, the selected optical design is a two-stage standard coronagraph with an external occulter, an internal occulter, and a Lyot stop. What is unique for this design is that a focal mask was inserted at the telescope focal plane. It works together with the field lens suppressing the stray light down by ~ another order of magnitude as compared to a traditional three-stage approach. During the optical design, a Fourier Transform based beam propagation software, i.e., GLAD, was used to model the beam path through the full coronagraph, from the external occulter to the detector array. All diffraction sensitive elements: external occulter, internal occulter, focal mask, and Lyot stop were carefully modeled and optimized. As a result, the requirement of achieving a stray light level which is one order of magnitude lower than F-corona was satisfied. On the other hand, to achieve the final suppression, a precision optical alignment is another must. This paper also presents our creative alignment procedure: using the combination of metrology, precision alignment equipment, and real time diffraction ring monitoring to minimize the diffraction. The final test results show that the suppression ratio (B/B 0 ) reaches 10 -11 level, which is equivalent to one order of magnitude lower than F-corona.

CODEX optical design and alignment↗

Performance of Titanium Optics on a NASA 30 Cm Ion Thruster

The results of performance tests with two titanium optics sets are presented and compared to those of molybdenum optics. All tests were conducted on a 30 cm ion thruster that was nearly identical to the NASA Solar Electric Propulsion Technology Application Readiness (NSTAR) thruster design. Optics performance tests were conducted over a thruster input power range of 0.5 to 4.6 kW. Optics performance including impingement-limited total voltages, electron backstreaming limits, screen grid ion transparencies, near-field beam current density profiles, beam divergence angles, and beam divergence thrust correction factors were determined throughout this power range. The impingement-limited total voltages for titanium optics were within 10 to 55 V of those for molybdenum optics. Electron backstreaming limit magnitude as a function of peak beam current density for both molybdenum and titanium optics were within a few volts of each other, indicating similar hot grid gaps for these two grid materials during steady-state operation. Beam divergence half-angles at 90 percent of the total beam current and thrust correction factors for both titanium optics sets were within one degree and one percent, respectively, of those for molybdenum optics. When thruster power was increased to 2.3 kW immediately following discharge ignition, the titanium screen grid came into contact with the accelerator grid within five minutes of ignition. Relative to molybdenum, titanium's larger thermal expansion and smaller thermal conductivity likely caused the screen grid to thermally expand more relative to the accelerator grid during startup.

Soulas, George C.↗

Surface roughness measured by optical signatures

To measure roughness of metal surfaces by nondestructive means direct laser beam at surface and record distribution pattern of intensity of reflected light to obtain optical signature for comparison with calibrated surface. Signature of machined surface with scratch compared to that of regularly-patterned machined surface may also detect imperfections.

Salvinski, R. J.↗

Laser power beaming system analyses

The successful demonstration of the PAMELA adaptive optics hardware and the fabrication of the BTOS truss structure were identified by the program office as the two most critical elements of the NASA power beaming program, so it was these that received attention during this program. Much of the effort was expended in direct program support at MSFC, but detailed technical analyses of the AMP deterministic control scheme and the BTOS truss structure (both the JPL design and a spherical one) were prepared and are attached, and recommendations are given.

Zeiders, Glenn W., Jr.↗

A 30-cm diameter argon ion source

A 30 cm diameter argon ion source was evaluated. Ion source beam currents up to 4a were extracted with ion energies ranging from 0.2 to 1.5 KeV. An ion optics scaling relation was developed for predicting ion beam extraction capability as a function of total extraction voltage, gas type, and screen grid open area. Ignition and emission characteristics of several hollow cathode geometries were assessed for purposes of defining discharge chamber and neutralizer cathodes. Also presented are ion beam profile characteristics which exhibit broad beam capability well suited for ion beam sputtering applications.

Sovey, J. S.↗

A 30-cm diameter argon ion source

A 30-cm diameter argon ion source was evaluated. Ion source beam currents up to 4A were extracted with ion energies ranging from 0.2 to 1.5 KeV. An ion optics scaling relation was developed for predicting ion beam extraction capability as a function of total extraction voltage, gas type and screen grid open area. Ignition and emission characteristics of several hollow cathode geometries were assessed for purposes of defining discharge chamber and neutralizer cathodes. Also presented are ion beam profile characteristics which exhibit broad beam capability well suited for ion beam sputtering applications.

Sovey, J. S.↗

The production of low-energy neutral oxygen beams by grazing-incidence neutralization

The Vanderbilt University neutral oxygen facility produces beams of low-energy neutral oxygen atoms by means of grazing-incidence collisions between ion beams and metal surfaces. Residual ions are reflected by applied electric fields. This method can utilize initial ion beams of either O(+) or O2(+) since a very large percentage of molecular oxygen ions are dissociated when they undergo grazing-incidence neutralization. The method of neutralization is applicable to low-energy beams and to all ions. Particular emphasis is on O and N2 beams for simulation of the low Earth orbit space environment. Since the beam is a pure O-neutral beam and since measurements of the interaction of the beam with solid surfaces are made spectroscopically, absolute reaction rates can be determined. The technique permits the beams to be used in conjunction with electron and photon irradiation for studies of synergistic effects. Comparisons of optical spectra of Kapton excited by 2.5-keV O, O(+), and O2(+) show significant differences. Optical spectra of Kapton excited by neutral oxygen beams of less than 1 keV have been recorded.

Albridge, R. G.↗

Development of a laser velocimeter for a large transonic wind tunnel

On a 8 x 6 Foot Supersonic Wind Tunnel a laser velocimeter was utilized in the testing of advanced high speed turbopropellers. The system, using a 15-W argon-ion laser, a 3-beam 2-axis transmitting-receiving optics package, a zoom lens with 1- to 4-m focal lengths, and a 0.4-m corner mirror was initially assembled and tested in the checkout room. During the time the system was located in the checkout area, experience was acquired in the alignment and operation of the system and the data acquisition system and software were developed. By using air jets to simulate tunnel air flow, the system worked quite well. However, problems with beam alignment arose because of reduced atmospheric pressure. Mounting the laser into a vessel maintained at atmospheric pressure with deflectors mounted to the external walls improved operation for about 2 hours before misalignment reoccurred. The system was remounted to the positioning platform in an enclosure that provides both thermal and acoustic isolation.

Greissing, J. P.↗

Handling and analysis of ices in cryostats and glove boxes in view of cometary samples

Comet nucleus sample return mission and other return missions from planets and satellites need equipment for handling and analysis of icy samples at low temperatures under vacuum or protective gas. Two methods are reported which were developed for analysis of small icy samples and which are modified for larger samples in cometary matter simulation experiments (KOSI). A conventional optical cryostat system was modified to allow for transport of samples at 5 K, ion beam irradiation, and measurement in an off-line optical spectrophotometer. The new system consists of a removable window plug containing nozzles for condensation of water and volatiles onto a cold finger. This plug can be removed in a vacuum system, changed against another plug (e.g., with other windows (IR, VIS, VUV) or other nozzles). While open, the samples can be treated under vacuum with cooling by manipulators (cut, removal, sample taking, irradiation with light, photons, or ions). After bringing the plug back, the samples can be moved to another site of analysis. For handling the 30 cm diameter mineral-ice samples from the KOSI experiments an 80x80x80 cm glove box made out of plexiglass was used. The samples were kept in a liquid nitrogen bath, which was filled from the outside. A stream a dry N2 and evaporating gas from the bath purified the glove box from impurity gases and, in particular, H2O, which otherwise would condense onto the samples.

Roessler, K.↗

Optoelectronic Control Of Phased-Array Antenna

Radiation patterns switched within microseconds. According to concept, digital beam-steering information destined for number of phased antenna elements transmitted in serial multiplex along optical fiber to optoelectronic integrated circuit (OEIC), demultiplexing information into parallel electronic channels to phase shifters associated with various elements. Because of small distances between elements of such arrays, compactness of optical fibers makes them attractive for distribution of beam-steering (phase-shifting) control signals. Also offers advantages of light weight, low attenuation, mechanical flexibility, large bandwidth, and immunity to both crosstalk and electromagnetic interference.

Bhasin, K. B.↗

Intense laser beams; Proceedings of the Meeting, Los Angeles, CA, Jan. 23, 24, 1992

Various papers on intense laser beams are presented. Individual topics addressed include: novel methods of copper vapor laser excitation, UCLA IR FEL, lasing characteristics of a large-bore copper vapor laser (CVL), copper density measurement of a large-bore CVL, high-power XeCl excimer laser, solid state direct-drive circuit for pumping gas lasers, united energy model for FELs, intensity and frequency instabilities in double-mode CO2 lasers, comparison of output power stabilities of CO and CO2 lasers, increasing efficiency of sealed-off CO lasers, thermal effects in singlet delta oxygen generation, optical extraction from the chemical oxygen-iodine laser medium, generation and laser diagnostic analysis of bismuth fluoride. Also discussed are: high-Q resonator design for an HF overtone chemical lasers, improved coatings for HF overtone lasers, scaled atmospheric blooming experiment, simulation on producing conjugate field using deformable mirrors, paraxial theory of amplitude correction, potential capabilities of adaptive optical systems in the atmosphere, power beaming research at NASA, system evaluations of laser power beaming options, performance projections for laser beam power to space, independent assessment of laser power beaming options, removal of atmospheric CFCs by lasers, efficiency of vaporization cutting by CVL.

Wade, Richard C.↗

HiPEP Ion Optics System Evaluation Using Gridlets

Experimental measurements are presented for sub-scale ion optics systems comprised of 7 and 19 aperture pairs with geometrical features that are similar to the HiPEP ion optics system. Effects of hole diameter and grid-to-grid spacing are presented as functions of applied voltage and beamlet current. Recommendations are made for the beamlet current range where the ion optics system can be safely operated without experiencing direct impingement of high energy ions on the accelerator grid surface. Measurements are also presented of the accelerator grid voltage where beam plasma electrons backstream through the ion optics system. Results of numerical simulations obtained with the ffx code are compared to both the impingement limit and backstreaming measurements. An emphasis is placed on identifying differences between measurements and simulation predictions to highlight areas where more research is needed. Relatively large effects are observed in simulations when the discharge chamber plasma properties and ion optics geometry are varied. Parameters investigated using simulations include the applied voltages, grid spacing, hole-to-hole spacing, doubles-to-singles ratio, plasma potential, and electron temperature; and estimates are provided for the sensitivity of impingement limits on these parameters.

Willliams, John D.↗

Progress of Multi-Beam Long Trace-Profiler Development

The multi-beam long trace profiler (LTP) under development at NASA s Marshall Space Flight Center[1] is designed to increase the efficiency of metrology of replicated X-ray optics. The traditional LTP operates on a single laser beam that scans along the test surface to detect the slope errors. While capable of exceptional surface slope accuracy, the LTP single beam scanning has slow measuring speed. As metrology constitutes a significant fraction of the time spent in optics production, an increase in the efficiency of metrology helps in decreasing the cost of fabrication of the x-ray optics and in improving their quality. Metrology efficiency can be increased by replacing the single laser beam with multiple beams that can scan a section of the test surface at a single instance. The increase in speed with such a system would be almost proportional to the number of laser beams. A collaborative feasibility study has been made and specifications were fixed for a multi-beam long trace profiler. The progress made in the development of this metrology system is presented.

Gubarev, Mikhail↗

Pulse Shepherding in Nonlinear Fiber Optics

In a wavelength division multiplexed fiber system, where pulses on different wavelength beams may co-propagate in a single mode fiber, the cross-phase-modulation (CPM) effects caused by the nonlinearity of the optical fiber are unavoidable. In other words, pulses on different wavelength beams can interact with and affect each other through the intensity dependence of the refractive index of the fiber. Although CPM will not cause energy to be exchanged among the beams, the pulse shapes and locations on these beams can be altered significantly. This phenomenon makes possible the manipulation and control of pulses co-propagating on different wavelength beams through the introduction of a shepherd pulse at a separate wavelength. How this can be accomplished is demonstrated in this paper.

Yeh, C.↗

Multi-Beam Laser Beacon Propagation Over Lunar Distance: Comparison of Predictions and Measurements

A multi-beam beacon was transmitted from the Optical Communication Telescope Laboratory (OCTL) located at Table Mountain, CA to the Lunar Laser Space Terminal (LLST), on-board the Lunar Atmospheric Dust and Environment Explorer (LADEE) spacecraft, during NASA’s recent Lunar Laser Communication Demonstration (LLCD). The laser beacon (1568?0.1 nm) was square wave modulated and sensed by a LLST quadrant sensor to enable link acquisition and tracking. LLST computed the mean received beacon power and returned 5 kHz sampled power time series over the downlink. Post-processing of the decoded downlink received at OCTL retrieved the uplink power recorded at LLST. The predicted mean irradiance delivered to LLST consistently agreed with the variable beam divergence transmitted from OCTL to within < 1 decibel (dB). Irradiance fluctuations detected at LLST were reconciled with an uplink wave-propagation model derived using independently monitored atmospheric parameters. We report good agreement of the scintillation index and atmospheric coherence time.

Biswas, A↗

Laser beam steering device

Agile beam steering is a critical requirement for airborne and space based LIDAR and optical communication systems. Design and test results are presented for a compact beam steering device with low inertia which functions by dithering two complementary (positive and negative) binary optic microlens arrays relative to each other in directions orthogonal to the direction of light propagation. The miniaturized system has been demonstrated at scan frequencies as high as 300 Hz, generating a 13 x 13 spot array with a total field of view of 2.4 degrees. The design is readily extendable to a 9.5 degree field of view and a 52 x 52 scan pattern. The system is compact - less than 2 in. on a side. Further size reductions are anticipated.

Motamedi, M. E.↗