Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Diamond detectors

With the first runs of the LHC in 2010 and luminosity upgrades expected from 2016, ATLAS and CMS are planning to upgrade their innermost tracking layers with the ultimate radiation hard technologies. Chemical Vapour Deposition (CVD) diamond has been used extensively in beam conditions monitors as the innermost detectors in the highest radiation areas of BaBar, Belle, CDF and all LHC experiments. This material is now being considered as a sensor material for the innermost layer(s) of the upgraded trackers. Recently the RD42 collaboration constructed, irradiated and tested polycrystalline and singlecrystal CVD diamond sensors to the highest fluences expected at the super-LHC. We present beam test results of chemical vapour deposition diamond up to fluences of 1.8x1016 24 GeV protons/cm2 illustrating that both polycrystalline and single-crystal chemical vapour deposition diamonds follow a single damage curve. We report preliminary results on polycrystalline diamond from an alternative manufacturer with promising performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Latest Results on Radiation Tolerance of Diamond Detectors

At present most experiments at the CERN Large Hadron Collider (LHC) are planning upgrades in the next 5-10 years for their innermost tracking layers as well as luminosity monitors to be able to take data as the luminosity increases and CERN moves toward the High Luminosity-LHC (HL-LHC). These upgrades will most likely require more radiation tolerant technologies than exist today. As a result this is one area of intense research, and Chemical Vapour Deposition (CVD) diamond is one such technology. CVD diamond has been used extensively in beam condition monitors as the innermost detectors in the highest radiation areas of all LHC experiments. This talk describes the preliminary radiation tolerance measurements of the highest quality polycrystalline CVD material for a range of proton energies and neutrons obtained with this material with the goal of elucidating the issues that should be addressed for future diamond based detectors. The talk presents the evolution of various semiconductor parameters as a function of dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron Beam Diagnostics Of The JLAB UV FEL

In this contribution we describe various systems and aspects of the electron beam diagnostics of the JLab UV FEL. The FEL is installed on a new bypass beam line at the existing 10 kW IR Upgrade FEL. Here, we describe a set of the following systems. A combination of OTR and phosphor viewers is used for measurements of the transverse beam profile, transverse emittance, and Twiss parameters. This system is also used for alignment of the optical cavity of the UV oscillator and to ensure the overlap between the electron beam and optical mode in the FEL wiggler. A system of beam position monitors equipped with log-amp based BPM electronics. Bunch length on the order of 120 fs RMS is measured with the help of a modified Martin-Puplett interferometer. The longitudinal transfer function measurement system is used to set up bunch compression in an optimal way, such that the LINAC RF curvature is compensated using only higher order magnetic elements of the beam transport. This set of diagnostic systems made a significant contribution in achieving first lasing of the FEL after only about 60 hours of beam operation.

43 PARTICLE ACCELERATORS↗

Time-of-Flight energy measurements with BPMs

The energy of a bunched non-relativistic ion beam can be deduced from measuring the beam phases in neighboring Beam Position Monitors (BPMs). This report presents estimations on implementation of such a procedure at PIP-II H- linac being constructed at Fermilab. In part, the case when the flight time between BPMs is larger than the period of BPM frequency is considered in detail. When the absolute BPM phase calibration is not available, the BPM phase information can be used to trace deviations of the beam energy from the desired value. Such “energy deviation” parameter is operationally implemented at the transfer line between 400 MeV Linac and the Booster, and its analog is expected to be used in the transfer line from PIP-II as well.

Shemyakin, Alexander [Fermilab] (ORCID:00000001501↗

Measurement of period difference in grating pair based on compensation analysis of phase difference between diffraction beams

We propose an experimental method for measuring the period difference in a grating pair. The method uses the relationship between the period difference and the phase difference of diffraction beams of the grating pair when gratings are translated along the grating-vector direction. The effect of the roll angular deviation of gratings can be eliminated by phase compensation with +1st- and -1st-order diffraction beams. Far-field intensity patterns of diffraction beams are monitored to adjust the relative attitude of gratings. For a pair of gratings with periods of {approx}0.674 {mu}m, the period difference was measured to be 0.4434 nm with an expanded uncertainty (k=2) of 0.0113 nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SAND - System for on-Axis Neutrino Detection - in the DUNE Near Detector Complex

The DUNE experiment aims to precisely measure the long baseline neutrino oscillation parameters. The DUNE Far Detector consists of four liquid argon time-projection chambers (total LAr mass of 17 kton for each cryostat), that will be installed at the Sanford Underground Research Facility (SURF) in South Dakota, 1300 km from the proton beam target. The Near Detector complex, located at Fermilab, is fundamental for limiting the systematic uncertainties, due to the neutrino/antineutrino flux and to the cross-section. It comprises three complementary detectors: ND-Lar, ND-Gar and SAND (System for on-Axis Neutrino Detection). ND-Lar and ND-Gar can move off-axis, while SAND is the only detector permanently on-axis, whose primary goal is to monitor the beam and to measure the flux. In this talk, the SAND design and the expected performances will be described together with its role within the Near Detector complex for the DUNE physics program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test results of the proton injector of the Proton Engineering Frontier Project accelerator

One of the goals of the Proton Engineering Frontier Project (PEFP) is to develop a 100 MeV proton accelerator. As a low energy part, a 20 MeV proton linac has been developed and tested. The 20 MeV accelerator consists of a 50 keV proton injector, a 3 MeV radio frequency quadrupole, and a 20 MeV drift tube linac. The proton injector includes a duoplasmatron type ion source and a low energy beam transport. After a preliminary test with 1 mA peak current of the 20 MeV accelerator, the proton injector was modified with the goal of increasing the 20 MeV beam current up to 20 mA peak value. The modifications include the reduction of the proton injector length, installation of a beam current monitor, and electron trap and supplement of the solenoid and steering magnets. In this paper, the modifications of the PEFP proton injector are described and initial test results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recording the synchrotron radiation by a picosecond streak camera for bunch diagnostics in cyclic accelerators

A PS-1/S1 picosecond streak camera with a linear sweep is used to measure temporal characteristics of synchrotron radiation pulses on a damping ring (DR) at the Budker Institute of Nuclear Physics (BINP) of the Siberian Branch of the Russian Academy of Sciences (Novosibirsk). The data obtained allow a conclusion as to the formation processes of electron bunches and their 'quality' in the DR after injection from the linear accelerator. The expediency of employing the streak camera as a part of an optical diagnostic accelerator complex for adjusting the injection from a linear accelerator is shown. Discussed is the issue of designing a new-generation dissector with a time resolution up to a few picoseconds, which would allow implementation of a continuous bunch monitoring in the DR during mutual work with the electron-positron colliders at the BINP. (acoustooptics)

43 PARTICLE ACCELERATORS↗

Dosimetric evaluation of 4 different treatment modalities for curative-intent stereotactic body radiation therapy for isolated thoracic spinal metastases

To investigate the dosimetric characteristics of 4 SBRT-capable dose delivery systems, CyberKnife (CK), Helical TomoTherapy (HT), Volumetric Modulated Arc Therapy (VMAT) by Varian RapidArc (RA), and segmental step-and-shoot intensity-modulated radiation therapy (IMRT) by Elekta, on isolated thoracic spinal lesions. CK, HT, RA, and IMRT planning were performed simultaneously for 10 randomly selected patients with 6 body types and 6 body + pedicle types with isolated thoracic lesions. The prescription was set with curative intent and dose of either 33 Gy in 3 fractions (3F) or 40 Gy in 5F to cover at least 90% of the planning target volume (PTV), correspondingly. Different dosimetric indices, beam-on time, and monitor units (MUs) were evaluated to compare the advantages/disadvantages of each delivery modality. In ensuring the dose-volume constraints for cord and esophagus of the premise, CK, HT, and RA all achieved a sharp conformity index (CI) and a small penumbra volume compared to IMRT. RA achieved a CI comparable to those from CK, HT, and IMRT. CK had a heterogeneous dose distribution in the target as its radiosurgical nature with less dose uniformity inside the target. CK had the longest beam-on time and the largest MUs, followed by HT and RA. IMRT presented the shortest beam-on time and the least MUs delivery. For the body-type lesions, CK, HT, and RA satisfied the target coverage criterion in 6 cases, but the criterion was satisfied in only 3 (50%) cases with the IMRT technique. For the body + pedicle-type lesions, HT satisfied the criterion of the target coverage of ≥90% in 4 of the 6 cases, and reached a target coverage of 89.0% in another case. However, the criterion of the target coverage of ≥90% was reached in 2 cases by CK and RA, and only in 1 case by IMRT. For curative-intent SBRT of isolated thoracic spinal lesions, RA is the first choice for the body-type lesions owing to its delivery efficiency (time); the second choice is CK or HT; HT is the preferential choice for the body + pedicle-type lesions. This study suggests further clinical investigations with longer follow-up for these studied cases.

61 RADIATION PROTECTION AND DOSIMETRY↗

Status of the ILC Main Linac BPM R and D

An introduction and the status of R&D activities for a high-resolution, 'cold' beam position monitor (BPM) and the related read-out electronics are discussed. Two different BPM detector concepts, to be attached to the SC quadrupole and located inside the ILC cryomodule, are currently under investigation: A resonant dipole-mode cavity-style BPM pickup, developed at Fermilab, and a re-entrant resonant coaxial waveguide BPM, designed by CEA-Saclay. While the 1.5 GHz dipole-mode cavity BPM is still in the R&D phase, the re-entrant BPM has already passed first beam tests, including its read-out system. Furthermore, the LAPP group is developing radiation tolerant digital read-out systems, which are tested at the CLIC test facility (CTF).

Wendt, M.↗

SU-F-J-202: Secondary Radiation Measurements for Charged Particle Therapy Monitoring: Fragmentation of Therapeutic He, C and O Ion Beams Impinging On a PMMA Target

Purpose: In Charged Particle Therapy (CPT), besides protons, there has been recently a growing interest in 4He, 12C and 16O beams. The secondary radiation produced in the interaction of those beams with a patient could be potentially used for on-line monitoring of range uncertainties in order to fully exploit the advantages of those light ions resulting from increased Radio Biological Effectiveness, reduced multiple scattering and Oxygen Enhancement Ratio. The study and precise characterization of secondary radiation (beta+, prompt gamma, charged fragments) is the cornerstone of any R&D activity aiming for online monitoring development and purpose of the analysis presented here. Methods: We present the measurements of the secondary radiation generated by He, C and O beams impinging on a beam stopping PMMA target. The data has been collected at the Heidelberg Ionbeam Therapy center (HIT), where several millions of collisions were recorded at different energies, relevant for therapeutical applications. Results: The experimental setup, as well as the analysis strategies will be reviewed. The detected particle fluxes as a function of the primary beam energy and the emission angle with respect to the beam direction will be presented and compared to the results of other available measurements. In addition, the energy spectra and emission shapes of charged secondary particles will be shown and discussed in the context of the primary beam range monitoring technique that is being developed by the ARPG collaboration, within the INSIDE project funded by the Italian research ministry. The implications for dose monitoring applications will be discussed, in the context of the current (or planned) state-of- the-art detector solutions. Conclusion: The characterization of the radiation produced by 12C, 4He and 16O beams fully supports the feasibility of on-line range monitoring in the clinical practice of CPT by means of secondary particles detection.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Semantic Regression for Disentangling Beam Losses in the Fermilab Main Injector and Recycler

Fermilab’s Main Injector enclosure houses two accelerators: the Main Injector (MI) and the Recycler (RR). In periods of joint operation, when both machines contain high intensity beam, radiative beam losses from MI and RR overlap on the enclosure’s beam loss monitoring (BLM) system, making it difficult to attribute those losses to a single machine. Incorrect diagnoses result in unnecessary downtime that incurs both financial and experimental cost. In this work, we introduce a novel neural approach for automatically disentangling each machine’s contributions to those measured losses. Using a continuous adaptation of the popular UNet architecture in conjunction with a novel data augmentation scheme, our model accurately infers the machine of origin on a per-BLM basis in periods of joint and independent operation. Crucially, by extracting beam loss information at varying receptive fields, the method is capable of learning both local and global machine signatures and producing high quality inferences using only raw BLM loss measurements.

43 PARTICLE ACCELERATORS↗

Lycoris - A large-area, high resolution beam telescope

We note that a high-resolution beam telescope is one of the most important and demanding infrastructure components at any test beam facility. Its main purpose is to provide reference particle tracks from the incoming test beam particles to the test beam users, which allows measurement of the performance of the device-under-test (DUT). LYCORIS, a six-plane compact beam telescope with an active area of ~ 10 x 10 cm 2 (extensible to 10 x 20 cm 2 ) was installed at the DESY II Test Beam Facility in 2019, to provide a precise momentum measurement in a 1 T solenoid magnet or to provide tracking over a large area. The overall design of Lycoris will be described as well as the performance of the chosen silicon sensor. The 25 μm pitch micro-strip sensor used for Lycoris was originally designed for the SiD detector concept for the International Linear Collider. It adopts a second metallization layer to route signals from strips to the bump-bonded KPiX ASIC and uses a wire-bonded flex cable for the connection to the DAQ and the power supply system. This arrangement eliminates the need for a dedicated hybrid PCB. Its performance was tested for the first time in this project. The system has been evaluated at the DESY II Test Beam Facility in several test-beam campaigns and has demonstrated an average single-point resolution of 7.07 μm.

47 OTHER INSTRUMENTATION↗

Improvement of the AC orbit bump method of local kick factor measurement using reference bunches

Here we have improved the AC orbit bump technique of local kick factor measurement. This technique, developed at NSLS-II a few years ago, is based on local sine-wave excitation of the electron beam by four fast correctors adjacent to the impedance location. By implementing reference bunches and the time gate function of beam position monitors, we are now able to measure the AC orbits of bunches with different intensities simultaneously. This improvement allows us to obtain the impedance-driven orbit distortion in a single measurement, significantly improving the measurement accuracy and reducing the measurement time.

36 MATERIALS SCIENCE↗

Use of ruthenium dyes for subnanosecond detector fidelity testing in real time transient absorption

Transient absorption spectroscopy is a powerful tool for the study of photoreactions on time scales from femtoseconds to seconds. Typically, reactions slower than {approx}1 ns are recorded by the ''classical'' technique; the reaction is triggered by an excitation flash, and absorption changes accompanying the reaction are recorded in real time using a continuous monitoring light beam and a detection system with sufficiently fast response. The pico- and femtosecond region can be accessed by the more recent ''pump-probe'' technique, which circumvents the difficulties of real time detection on a subnanosecond time scale. This is paid for by accumulation of an excessively large number of shots to sample the reaction kinetics. Hence, it is of interest to extend the classical real time technique as far as possible to the subnanosecond range. In order to identify and minimize detection artifacts common on a subnanosecond scale, like overshoot, ringing, and signal reflections, rigorous testing is required of how the detection system responds to fast changes of the monitoring light intensity. Here, we introduce a novel method to create standard signals for detector fidelity testing on a time scale from a few picoseconds to tens of nanoseconds. The signals result from polarized measurements of absorption changes upon excitation of ruthenium complexes {l_brace}[Ru(bpy){sub 3}]{sup 2+} and a less symmetric derivative{r_brace} by a short laser flash. Two types of signals can be created depending on the polarization of the monitoring light with respect to that of the excitation flash: a fast steplike bleaching at magic angle and a monoexponentially decaying bleaching for parallel polarizations. The lifetime of the decay can be easily varied via temperature and viscosity of the solvent. The method is applied to test the performance of a newly developed real time transient absorption setup with 300 ps time resolution and high sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The study of high-frequency pick-ups for electron beam position measurements in the AWAKE common beamline

The common beamline of the AWAKE experiment at CERN involves the co-propagation of two particle beams: protons with 48 nC bunch charge and 250 ps bunch length, and electrons with up to 600 pC bunch charge and approximately 4 ps bunch length. The existing operational beam position monitors at AWAKE cannot measure the electron bunches whilst the more-intense proton bunches are present, due to their low operating frequency. In order to try to address this challenge, two different types of high-frequency pick-ups were studied, a conical-shaped button pick-up and a Cherenkov diffraction radiation-based pick-up designed to operate at around 30 GHz. Both devices were installed at AWAKE and were connected to two identical read-out systems designed by TRIUMF. This contribution presents and discusses the results obtained from beam-based measurements during the current experimental year.

43 PARTICLE ACCELERATORS↗

SU-E-T-614: Plan Averaging for Multi-Criteria Navigation of Step-And-Shoot IMRT

Purpose: Step-and-shoot IMRT is fundamentally discrete in nature, while multi-criteria optimization (MCO) is fundamentally continuous: the MCO planning consists of continuous sliding across the Pareto surface (the set of plans which represent the tradeoffs between organ-at-risk doses and target doses). In order to achieve close to real-time dose display during this sliding, it is desired that averaged plans share many of the same apertures as the pre-computed plans, since dose computation for apertures generated on-the-fly would be expensive. We propose a method to ensure that neighboring plans on a Pareto surface share many apertures. Methods: Our baseline step-and-shoot sequencing method is that of K. Engel (a method which minimizes the number of segments while guaranteeing the minimum number of monitor units), which we customize to sequence a set of Pareto optimal plans simultaneously. We also add an error tolerance to study the relationship between the number of shared apertures, the total number of apertures needed, and the quality of the fluence map re-creation. Results: We run tests for a 2D Pareto surface trading off rectum and bladder dose versus target coverage for a clinical prostate case. We find that if we enforce exact fluence map recreation, we are not able to achieve much sharing of apertures across plans. The total number of apertures for all seven beams and 4 plans without sharing is 217. With sharing and a 2% error tolerance, this number is reduced to 158 (73%). Conclusion: With the proposed method, total number of apertures can be decreased by 42% (averaging) with no increment of total MU, when an error tolerance of 5% is allowed. With this large amount of sharing, dose computations for averaged plans which occur during Pareto navigation will be much faster, leading to a real-time what-you-see-is-what-you-get Pareto navigation experience. Minghao Guo and Hao Gao were partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000) and the Shanghai Pujiang Talent Program (#14PJ1404500)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electron Bunch Length Monitors using Spatially Encoded Electro-optical Technique

A single-shot, nondestructive, electro-optical, electron bunch length monitor is experimentally verified by encoding the Coulomb field of the bunch profile on the spatial intensity distribution of an unchirped femtosecond laser pulse in an orthogonal geometry (hence, a temporal-to-spatial transformation). This electron bunch measurement scheme can simultaneously measure large timing jitter (?ps) with a wide measurement timespan covering picosecond to subpicosecond ranges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗