Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3D Visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Semi-Automatic Geographic Information System Framework for Creating Photo-Realistic Digital Twin Cities to Support Autonomous Driving Research

Digital twin cities are frequently used in vehicle and traffic simulations to render realistic on-road driving scenarios under various traffic and environmental conditions. These digital twins provide a high-fidelity replica of the physical world (e.g., buildings, roads, infrastructures, traffic) to create three-dimensional (3D) virtual-physical environments to support various emerging vehicle and transportation technologies such as connected and automated vehicles. These virtual environments provide a cost-effective digital proving ground to evaluate, validate, and test emerging technologies that include control algorithms, localization, perception, and sensors. Replicating a real-world traffic scenario in a digital twin using a traditional 3D modeling approach is a time-consuming and labor-intensive effort. Here this paper presents a semi-automated spatial framework to construct realistic 3D digital twin cities to support autonomous driving research using readily available geographic information system (GIS) data and 3D prefabricated (prefab) models. We start with a comprehensive review of geospatial data sources of essential digital entities required in a 3D digital twin city and present an integrated GIS-3D modeling pipeline using customized QGIS/GDAL and Blender scripting in Python. The pipeline outputs are realistic 3D digital twin cities compatible with common vehicle simulation software, such as CARLA and IPG CarMaker. The paper closes with a showcase to demonstrate the quality and usability of a digital twin city created to replicate the Shallowford Road corridor in Chattanooga in both Unity and Unreal engine-based virtual environment. The generated digital twin city can be applied to a hardware-in-the-loop simulation environment with an actual testing vehicle to facilitate autonomous driving research.

33 ADVANCED PROPULSION SYSTEMS↗

In-Situ Visualization of a Growing Brittle Crack in Aluminum Oxynitride Using Synchrotron X-Rays and the Double-Cleavage Drilled Compression Geometry

Brittle fracture is difficult to study in situ due to the speed of a growing crack and the often-catastrophic nature of failure in brittle materials. As a result, the influence of microstructural considerations, such as orientation, grain boundary locations, and strain field, on the crack path remains poorly understood. Presented in this study is a method addressing this knowledge gap, which utilizes the double-cleavage drilled compression geometry to achieve quasi-stable fracture in aluminum oxynitride (AlON). Synchrotron X-ray micro-computed tomography is used to characterize the crack shape and length, while high-energy diffraction microscopy provides information on the strains, orientations, and shapes of grains in the microstructure surrounding the crack tip. During testing, the crack grew in discrete and irregular jumps while the fracture toughness falls within reported ranges. The crack in AlON is found to have no greater tendency to crack intergranularly as compared to transgranularly, and grains which are cracked transgranularly do not display a trend in orientation or stress when compared to those around which the crack followed a grain boundary. The high resolution of the crack path and microstructural data provides a path forward for modeling and understanding 3D brittle fracture.

Gorske, Sara F.↗

Novel Radiobiological Gamma Index for Evaluation of 3-Dimensional Predicted Dose Distribution

Purpose: To propose a gamma index-based dose evaluation index that integrates the radiobiological parameters of tumor control (TCP) and normal tissue complication probabilities (NTCP). Methods and Materials: Fifteen prostate and head and neck (H&N) cancer patients received intensity modulated radiation therapy. Before treatment, patient-specific quality assurance was conducted via beam-by-beam analysis, and beam-specific dose error distributions were generated. The predicted 3-dimensional (3D) dose distribution was calculated by back-projection of relative dose error distribution per beam. A 3D gamma analysis of different organs (prostate: clinical [CTV] and planned target volumes [PTV], rectum, bladder, femoral heads; H&N: gross tumor volume [GTV], CTV, spinal cord, brain stem, both parotids) was performed using predicted and planned dose distributions under 2%/2 mm tolerance and physical gamma passing rate was calculated. TCP and NTCP values were calculated for voxels with physical gamma indices (PGI) >1. We propose a new radiobiological gamma index (RGI) to quantify the radiobiological effects of TCP and NTCP and calculate radiobiological gamma passing rates. Results: The mean RGI gamma passing rates for prostate cases were significantly different compared with those of PGI (P<.03–.001). The mean RGI gamma passing rates for H&N cases (except for GTV) were significantly different compared with those of PGI (P<.001). Differences in gamma passing rates between PGI and RGI were due to dose differences between the planned and predicted dose distributions. Radiobiological gamma distribution was visualized to identify areas where the dose was radiobiologically important. Conclusions: RGI was proposed to integrate radiobiological effects into PGI. This index would assist physicians and medical physicists not only in physical evaluations of treatment delivery accuracy, but also in clinical evaluations of predicted dose distribution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-speed quantitative X-ray multi-contrast imaging with deep learning based modulated pattern analysis

The advent of X-ray multi-contrast imaging methods, providing absorption, phase, and dark-field images, holds tremendous promise for complementary and non-destructive visualization of inner structures within materials and bio-samples. However, the low efficiency in measuring and analyzing X-ray modulated patterns has hindered their application in high-resolution in situ imaging. In this work, the Enhanced Scanning Pattern-based Imaging Neural Network (ESPINNet) is introduced as a powerful tool for achieving high-speed, high-resolution quantitative imaging. ESPINNet is faster than correlation-based speckle tracking methods such as XSVT and UMPA, and provides a balanced performance in terms of resolution and speed for data collection by using fewer scanning images. In comparison with our previously developed neural network, ESPINNet introduces the capability to generate dark-field images, further enhancing its versatility. By leveraging scanning patterns, ESPINNet significantly improves resolution and measurement precision. Furthermore, its adaptability to various modulation patterns, including those produced by sandpaper, coded masks, or gratings, ensures broad applicability. These features enable real-time 2D and 3D multi-contrast imaging, positioning ESPINNet as a transformative solution for applications in materials science and biomedical research, particularly for high-speed and in situ measurements.

X-ray at-wavelength metrology↗

Evaluation of potential internal target volume of liver tumors using cine-MRI

Purpose: Four-dimensional computed tomography (4DCT) is widely used for evaluating moving tumors, including lung and liver cancers. For patients with unstable respiration, however, the 4DCT may not visualize tumor motion properly. High-speed magnetic resonance imaging (MRI) sequences (cine-MRI) permit direct visualization of respiratory motion of liver tumors without considering radiation dose exposure to patients. Here, the authors demonstrated a technique for evaluating internal target volume (ITV) with consideration of respiratory variation using cine-MRI. Methods: The authors retrospectively evaluated six patients who received stereotactic body radiotherapy (SBRT) to hepatocellular carcinoma. Before acquiring planning CT, sagittal and coronal cine-MRI images were acquired for 30 s with a frame rate of 2 frames/s. The patient immobilization was conducted under the same condition as SBRT. Planning CT images were then acquired within 15 min from cine-MRI image acquisitions, followed by a 4DCT scan. To calculate tumor motion, the motion vectors between two continuous frames of cine-MRI images were calculated for each frame using the pyramidal Lucas–Kanade method. The target contour was delineated on one frame, and each vertex of the contour was shifted and copied onto the following frame using neighboring motion vectors. 3D trajectory data were generated with the centroid of the contours on sagittal and coronal images. To evaluate the accuracy of the tracking method, the motion of clearly visible blood vessel was analyzed with the motion tracking and manual detection techniques. The target volume delineated on the 50% (end-exhale) phase of 4DCT was translated with the trajectory data, and the distribution of the occupancy probability of target volume was calculated as potential ITV (ITV {sub Potential}). The concordance between ITV {sub Potential} and ITV estimated with 4DCT (ITV {sub 4DCT}) was evaluated using the Dice’s similarity coefficient (DSC). Results: The distance between blood vessel positions determined with motion tracking and manual detection was analyzed. The mean and SD of the distance were less than 0.80 and 0.52 mm, respectively. The maximum ranges of tumor motion on cine-MRI were 2.4 ± 1.4 mm (range, 1.0–5.0 mm), 4.4 ± 3.3 mm (range, 0.8–9.4 mm), and 14.7 ± 5.9 mm (range, 7.4–23.4 mm) in lateral, anterior–posterior, and superior–inferior directions, respectively. The ranges in the superior–inferior direction were larger than those estimated with 4DCT images for all patients. The volume of ITV {sub Potential} was 160.3% ± 13.5% (range, 142.0%–179.2%) of the ITV {sub 4DCT}. The maximum DSC values were observed when the cutoff value of 24.7% ± 4.0% (range, 20%–29%) was applied. Conclusions: The authors demonstrated a novel method of calculating 3D motion and ITV {sub Potential} of liver cancer using orthogonal cine-MRI. Their method achieved accurate calculation of the respiratory motion of moving structures. Individual evaluation of the ITV {sub Potential} will aid in improving respiration management and treatment planning.

60 APPLIED LIFE SCIENCES↗

High redshift LBGs from deep broadband imaging for future spectroscopic surveys

Lyman break galaxies (LBGs) are promising probes for clustering measurements at high redshift, z > 2, a region only covered so far by Lyman-α forest measurements. Here, in this paper, we investigate the feasibility of selecting LBGs by exploiting the existence of a strong deficit of flux shortward of the Lyman limit, due to various absorption processes along the line of sight. The target selection relies on deep imaging data from the HSC and CLAUDS surveys in the g, r, z and u bands, respectively, with median depths reaching 27 AB in all bands. The selections were validated by several dedicated spectroscopic observation campaigns with DESI. Visual inspection of spectra has enabled us to develop an automated spectroscopic typing and redshift estimation algorithm specific to LBGs. Based on these data and tools, we assess the efficiency and purity of target selections optimised for different purposes. Selections providing a wide redshift coverage retain 57% of the observed targets after spectroscopic confirmation with DESI, and provide an efficiency for LBGs of 83 ± 3%, for a purity of the selected LBG sample of 90 ± 2%. This would deliver a confirmed LBG density of ~ 620 deg$^{-2}$ in the range 2.3 < z < 3.5 for a r-band limiting magnitude r < 24.2. Selections optimised for high redshift efficiency retain 73% of the observed targets after spectroscopic confirmation, with 89 ± 4% efficiency for 97 ± 2% purity. This would provide a confirmed LBG density of ~ 470 deg$^{-2}$ in the range 2.8 < z < 3.5 for a r-band limiting magnitude r < 24.5.A preliminary study of the LBG sample 3d-clustering properties is also presented and used to estimate the LBG linear bias. A value of b$_{LBG}$ = 3.3 ± 0.2 (stat.) is obtained for a mean redshift of 2.9 and a limiting magnitude in r of 24.2, in agreement with results reported in the literature.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-FG-202-08: Assessment of Treatment Response Via Longitudinal Diffusion MRI On A MRI-Guided System: Initial Experience of Quantitative Analysis

Purpose: To report our initial experience of systematic monitoring treatment response using longitudinal diffusion MR images on a Co-60 MRI-guided radiotherapy system. Methods: Four patients, including 2 head-and-necks, 1 sarcoma and 1 GBM treated on a 0.35 Tesla MRI-guided treatment system, were analyzed. For each patient, 3D TrueFISP MRIs were acquired during CT simulation and before each treatment for treatment planning and patient setup purposes respectively. Additionally, 2D diffusion-weighted MR images (DWI) were acquired weekly throughout the treatment course. The gross target volume (GTV) and brainstem (as a reference structure) were delineated on weekly 3D TrueFISP MRIs to monitor anatomy changes, the contours were then transferred onto the corresponding DWI images after fusing with the weekly TrueFISP images. The patient-specific temporal and spatial variations during the entire treatment course, such as anatomic changes, target apparent diffusion coefficient (ADC) distribution were evaluated in a longitudinal pattern. Results: Routine MRI revealed progressive soft-tissue GTV volume changes (up to 53%) for the H&N cases during the treatment course of 5–7 weeks. Within the GTV, the mean ADC values varied from −44% (ADC decrease) to +26% (ADC increase) in a week. The gradual increase of ADC value was inversely associated with target volume variation for one H&N case. The maximal changes of mean ADC values within the brainstem were 5.3% for the H&N cases. For the large size sarcoma and GBM tumors, spatial heterogeneity and temporal variations were observed through longitudinal ADC analysis. Conclusion: In addition to the superior soft-tissue visualization, the 0.35T MR system on ViewRay showed the potential to quantitatively measure the ADC values for both tumor and normal tissues. For normal tissue that is minimally affected by radiation, its ADC values are reproducible. Tumor ADC values show temporal and spatial fluctuation that can be exploited for personalized adaptive therapy.

60 APPLIED LIFE SCIENCES↗

FY21 Progress Report: SRNL Analysis of ICCWR LCM and WAMS data for Corrosion and Cracking

The development of algorithms for machine learning and data analysis for the 3013 Surveillance Program is a collaborative effort by the Savannah River National Laboratory (SRNL) and the University of South Carolina (USC). For corrosion detection, Laser Confocal Microscope (LCM) or Wide Area 3D Measurement System (WAMS) data is extracted from large binary files, with software written to convert the data to physical attributes (e.g., height, color and grayscale values; all as functions of a location in a plane projection). A user-friendly Matlab Graphical User Interface (GUI) that reads data from either LCM or WAMS files was developed to integrate input data with software developed for processing and evaluation. The GUI can selectively download binary data, interrogate data attributes, label data, flag significant features, execute Machine Learning (ML) algorithms, output parameters for trained ML algorithms, report ML model accuracy with respect to labeled data, and generate graphical representations for various analyses. Features can be called out by user-specified thresholds, manual labeling or machine learning algorithms when they have been completed. The ability to rapidly label data is important because of the volume of data required for training machine learning algorithms. The GUI has the flexibility to allow addition of improved ML algorithms, methods for data visualization, and statistical computations. Statistical analyses via the GUI include areas of pits within a defined range of pit depths, correlations between Red-Green-Blue (RGB) or grayscale intensity and relative surface height, covariances between values associated with features, and feature histograms. The development of supervised machine learning algorithms, however, has been hindered by a lack of training data. The machine learning algorithms for crack identification are being refined but require improvements to the true positive rate for crack detection. This shortcoming is an artifact of the limited training data currently available, perhaps more so than the structure of the neural networks. At present, the best results are had from a consensus over an ensemble of randomly generated Deep Neural Network (DNN) or Convolutional Neural Network (CNN) algorithms. Although the consensus accuracy method has yielded optimum true positive and true negative rates in excess of 80%, additional validation testing is necessary. In addition to the suite of LCM data that was initially used, and which represents the majority of the work presented in this report, WAMS image data was also reviewed at a preliminary level. The review included a comparison between image resolution and dynamic range for each method. WAMS (ZON file) image data was found to have a pixel pitch of 3.69μm compared to 1 μm for the LCM (vk4 file) data, which implies a lower resolution for the WAMS images. Conversely, the ratio of dynamic range of the WAMS data to the LCM data was approximately 41:20 for height data, suggesting that information from WAMS should more accurately determine the depth of pits. At present, the significance of the greater dynamic range of the WAMS data relative to the LCM data has not yet been evaluated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Documentation and Instructions for Running Two Python Scripts that Aid in Setting up 3D Measurements using the Polytec 3D Scanning Laser Doppler Vibrometer

Sandia National Laboratories has recently purchased a Polytec 3D Scanning Laser Doppler Vibrometer for vibration measurement. This device has proven to be a very nice tool for making vibration measurements, and has a number of advantages over traditional sensors such as accelerometers. The non-contact nature of the laser vibrometer means there is no mass loading due to measuring the response. Additionally, the laser scanning heads can position the laser spot much more quickly and accurately than placing an accelerometer or performing a roving hammer impact. The disadvantage of the system is that a significant amount of time must be invested to align the lasers with each other and the part so that the laser spots can be accurately positioned. The Polytec software includes a number of nice tools to aid in this procedure; however, certain portions are still tedious. Luckily, the Polytec software is readily extensible by programming macros for the system, so tedious portions of the procedure can be made easier by automating the process. The Polytec Software includes a WinWrap (similar to Visual Basic) editor and interface to run macros written in that programming language. The author, however, is much more proficient in Python, and the latter also has a much larger set of libraries that can be used to create very complex macros, while taking advantage of Python’s inherent readability and maintainability.

47 OTHER INSTRUMENTATION↗

AutoAtlas: Neural Network for 3D Unsupervised Partitioning and Representation Learning

Here we present a novel neural network architecture called AutoAtlas for fully unsupervised partitioning and representation learning of 3D brain Magnetic Resonance Imaging (MRI) volumes. AutoAtlas consists of two neural network components: one neural network to perform multi-label partitioning based on local texture in the volume, and a second neural network to compress the information contained within each partition. We train both of these components simultaneously by optimizing a loss function that is designed to promote accurate reconstruction of each partition, while encouraging spatially smooth and contiguous partitioning, and discouraging relatively small partitions. We show that the partitions adapt to the subject specific structural variations of brain tissue while consistently appearing at similar spatial locations across subjects. AutoAtlas also produces very low dimensional features that represent local texture of each partition. We demonstrate prediction of metadata associated with each subject using the derived feature representations and compare the results to prediction using features derived from FreeSurfer anatomical parcellation. Since our features are intrinsically linked to distinct partitions, we can then map values of interest, such as partition-specific feature importance scores onto the brain for visualization.

42 ENGINEERING↗

Savannah River Site H-Canyon Advancing Technologies for Remote Inspections - 20345

In 2017, the DOE Environmental Management Office of Technology Development (DOE-EM TD) sponsored the H-Canyon Advanced Technology Demonstration (ATD) to demonstrate to DOE facilities the value of using new commercial-off-the-shelf (COTS) and near-ready technologies to solve difficult problems and enhance worker safety. The DOE Savannah River Site (SRS) H-Canyon Air Exhaust Tunnel (HCAEX) inspection task was identified as representative of the hazardous, human denied environments which could benefit from advanced technologies. The HCAEX underground concrete tunnel is visually inspected biannually using a camera mounted on a remotely operated vehicle (ROV) designed and built by SRNL. While tunnel images have provided valuable visual information, it is desirable to have a higher order of understanding of the environment to support a more thorough structural integrity (SI) analysis and for long term planning purposes. As part of the ATD, the Concrete Integrated Product Team (CIPT) was formed to identify and evaluate available sensors and methods mature enough to remotely obtain tunnel concrete characterization data of high value and with a high probability of success. The team included SMEs and H-Canyon stakeholders in the field of concrete, nondestructive examination (NDE), structural integrity, sensors and remote systems from SRNL, SRNS, LANL, DOE-SR and the Army Corps of Engineering. The CIPT completed an in-depth identification of customer concrete inspection needs and potential technology solutions. Sensors and methods were evaluated on performance, data usefulness, cost and the feasibility of a successful deployment given the unique tunnel access challenges and environment. Two technologies were identified as promising by the CIPT for near term demonstration and evaluation: Lidar (Light Detection and Ranging) 3-dimensional (3D) mapping and remote robotic deployment of NDE instrumentation. Laser spectroscopy to characterize tunnel surface chemical changes was also of interest, but presently cost prohibitive. This paper will include a discussion of the two efforts underway to evaluate and implement the CIPT recommendations. First, the status of the November 2019 deployment of Lidar at a single location into the tunnel is presented. This initial deployment provided the team a learning curve and lessons learned on the challenges of tunnel deployment to include remote operation and data collection, stabilization of the sensor in high air flow (∼30 mph), ability to achieve a tolerance accuracy of 0.25-inches, and the probability to identify change in tunnel dimensions over time. Secondly, a discussion on the development of the Robotic Arm Concrete Inspection Test Bed capable of deploying NDE instruments to examine custom concrete forms will be presented. Concrete forms simulating the rough concrete surfaces, strength, composition and potential structural defects that can be found at our DOE EM facilities have been designed and built for the test bed. Two state-of-the art concrete NDE instruments have been identified as having potential to work on rough concrete walls, they are being tested and characterized as to their ability to provide desired structural integrity data to include wall thickness and defect identification on the developed test beams. Lastly, lessons learned, and the path forward will be presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MFA-DVR: direct volume rendering of MFA models

3D volume rendering is widely used to reveal insightful intrinsic patterns of volumetric datasets across many domains. However, the complex structures and varying scales of volumetric data can make efficiently generating high-quality volume rendering results a challenging task. Multivariate functional approximation (MFA) is a new data model that addresses some of the critical challenges: high-order evaluation of both value and derivative anywhere in the spatial domain, compact representation for large-scale volumetric data, and uniform representation of both structured and unstructured data. Here, in this paper, we present MFA-DVR, the first direct volume rendering pipeline utilizing the MFA model, for both structured and unstructured volumetric datasets. We demonstrate improved rendering quality using MFA-DVR on both synthetic and real datasets through a comparative study. We show that MFA-DVR not only generates more faithful volume rendering than using local filters but also performs faster on high-order interpolations on structured and unstructured datasets. MFA-DVR is implemented in the existing volume rendering pipeline of the Visualization Toolkit (VTK) to be accessible by the scientific visualization community.

97 MATHEMATICS AND COMPUTING↗

TopoSZ: Preserving Topology in Error-Bounded Lossy Compression

Existing error-bounded lossy compression techniques control the pointwise error during compression to guarantee the integrity of the decompressed data. However, they typically do not explicitly preserve the topological features in data. When performing post hoc analysis with decompressed data using topological methods, preserving topology in the compression process to obtain topologically consistent and correct scientific insights is desirable. In this paper, we introduce TopoSZ, an error-bounded lossy compression method that preserves the topological features in 2D and 3D scalar fields. Specifically, we aim to preserve the types and locations of local extrema as well as the level set relations among critical points captured by contour trees in the decompressed data. The main idea is to derive topological constraints from contour-tree-induced segmentation from the data domain, and incorporate such constraints with a customized error-controlled quantization strategy from the SZ compressor (version 1.4). In conclusion, our method allows users to control the pointwise error and the loss of topological features during the compression process with a global error bound and a persistence threshold.

97 MATHEMATICS AND COMPUTING↗

MO-DE-BRA-06: 3D Image Acquisition and Reconstruction Explained with Online Animations

Purpose: Understanding the principles of 3D imaging and image reconstruction is fundamental to the field of medical imaging. Clinicians, technologists, physicists, patients, students, and inquisitive minds all stand to benefit from greater comprehension of the supporting technologies. To help explain the basic principles of 3D imaging, we developed multi-frame animations that convey the concepts of tomographic imaging. The series of free (gif) animations are accessible online, and provide a multimedia introduction to the main concepts of image reconstruction. Methods: Text and animations were created to convey the principles of analytic tomography in CT, PET, and SPECT. Specific topics covered included: principles of sinograms/image data storage, forward projection, principles of PET acquisitions, and filtered backprojection. A total of 8 animations were created and presented for CT, PET, and digital phantom formats. In addition, a free executable is also provided to allow users to create their own tomographic animations – providing an opportunity for interaction and personalization to help foster user interest. Results: Tutorial text and animations have been posted online, freely available to view or download. The animations are in first position in a google search of “image reconstruction animations”. The website currently receives approximately 200 hits/month, from all over the world, and the usage is growing. Positive feedback has been collected from users. Conclusion: We identified a need for improved teaching tools to help visualize the (temporally variant) concepts of image reconstruction, and have shown that animations can be a useful tool for this aspect of education. Furthermore, posting animations freely on the web has shown to be a good way to maximize their impact in the community. In future endeavors, we hope to expand this animated content, to cover principles of iterative reconstruction, as well as other phenomena relating to imaging.

60 APPLIED LIFE SCIENCES↗

Visualizing Size-Dependent Dynamics of CeO 2-δ {100}-Supported CoO x Nanoparticles Under CO 2 Hydrogenation Conditions

Carbon dioxide is a major greenhouse gas. In order to optimize processes focused on its chemical valorization, one needs detailed information about the effects of CO 2 and/or CO 2 /H 2 mixtures on the structure and morphology of metal/oxide catalysts. Here, in this study, the evolution of a catalyst with cobalt supported on CeO 2 -cube nanostructures under CO 2 hydrogenation conditions was investigated by using a set of in situ characterization techniques (X-ray absorption fine structure, X-ray diffraction, diffuse reflectance infrared Fourier transform spectroscopy, and environmental transmission electron microscopy (TEM)). The {100} facets of the ceria support displayed an unexpectedly high stability due to strong interactions with the aggregates of cobalt oxide. A significant influence of interfacial bonding between CoO x and CeO 2-δ {100} is evident through a clear preference in the orientation of CoO x nanoparticles (NPs) with respect to the substrate. For initially reduced Co/CeO 2 -cube nanostructures, a kinetically controlled oxidation of cobalt upon the introduction of CO 2 was observed during the early stages of CO 2 hydrogenation. Environmental TEM revealed the size-dependent morphological behavior of cobalt oxide NPs due to strong interactions with the CeO 2 {100} surface. When the environment was switched from H 2 to a mixture of H 2 and CO 2 at 250 °C, small CoO x NPs (in the largest dimension < 2.5 nm) rapidly transformed from a pyramidal three-dimensional (3D) form to a planar, monatomic layer attached to the concurrently oxidized CeO 2-δ {100} surface. This maximizes the number of sites available for the binding of CO 2 or reaction intermediates. The shape transformation reflected the oxophilic character of cobalt and strong metal–support interactions. The removal of CO 2 from the gas phase led to a reduction of the cobalt oxide NPs by hydrogen and a reversible two-dimensional → 3D transformation. In contrast, no significant morphological changes, apart from further oxidation, were observed for big CoO x NPs (in the largest dimension > 3 nm). These trends are not seen for nanoparticles of noble metals. The observed morphological and structural changes in the small CoO x NPs affected the stability of reaction intermediates and modified the selectivity of the CoO x /CeO 2 catalyst system for methane production.

36 MATERIALS SCIENCE↗

Multiscale X-ray phase contrast imaging of human cartilage for investigating osteoarthritis formation

The evolution of cartilage degeneration is still not fully understood, partly due to its thinness, low radio-opacity and therefore lack of adequately resolving imaging techniques. X-ray phase-contrast imaging (X-PCI) offers increased sensitivity with respect to standard radiography and CT allowing an enhanced visibility of adjoining, low density structures with an almost histological image resolution. This study examined the feasibility of X-PCI for high-resolution (sub-) micrometer analysis of different stages in tissue degeneration of human cartilage samples and compare it to histology and transmission electron microscopy. Ten 10%-formalin preserved healthy and moderately degenerated osteochondral samples, post-mortem extracted from human knee joints, were examined using four different X-PCI tomographic set-ups using synchrotron radiation the European Synchrotron Radiation Facility (France) and the Swiss Light Source (Switzerland). Volumetric datasets were acquired with voxel sizes between 0.7 × 0.7 × 0.7 and 0.1 × 0.1 × 0.1 µm 3 . Data were reconstructed by a filtered back-projection algorithm, post-processed by ImageJ, the WEKA machine learning pixel classification tool and VGStudio max. For correlation, osteochondral samples were processed for histology and transmission electron microscopy. X-PCI provides a three-dimensional visualization of healthy and moderately degenerated cartilage samples down to a (sub-)cellular level with good correlation to histologic and transmission electron microscopy images. X-PCI is able to resolve the three layers and the architectural organization of cartilage including changes in chondrocyte cell morphology, chondrocyte subgroup distribution and (re-)organization as well as its subtle matrix structures. X-PCI captures comprehensive cartilage tissue transformation in its environment and might serve as a tissue-preserving, staining-free and volumetric virtual histology tool for examining and chronicling cartilage behavior in basic research/laboratory experiments of cartilage disease evolution.

3D analysis↗

Real-time X-ray phase-contrast imaging using SPINNet—a speckle-based phase-contrast imaging neural network

X-ray phase-contrast imaging has become indispensable for visualizing samples with low absorption contrast. In this regard, speckle-based techniques have shown significant advantages in spatial resolution, phase sensitivity, and implementation flexibility compared with traditional methods. However, the computational cost associated with data inversion has hindered their wider adoption. By exploiting the power of deep learning, we developed a speckle-based phase-contrast imaging neural network (SPINNet) that significantly improves the imaging quality and boosts the phase retrieval speed by at least 2 orders of magnitude compared to existing methods. To achieve this performance, we combined SPINNet with a coded-mask-based technique, an enhanced version of the speckle-based method. Using this scheme, we demonstrate the simultaneous reconstruction of absorption and phase images on the order of 100 ms, where a traditional correlation-based analysis would take several minutes even with a cluster. In addition to significant improvement in speed, our experimental results show that the imaging and phase retrieval quality of SPINNet outperform existing single-shot speckle-based methods. Furthermore, we successfully demonstrate SPINNet application in x-ray optics metrology and 3D x-ray phase-contrast tomography. Our result shows that SPINNet could enable many applications requiring high-resolution and fast data acquisition and processing, such as in situ and in operando 2D and 3D phase-contrast imaging and real-time at-wavelength metrology and wavefront sensing.

36 MATERIALS SCIENCE↗

Accelerating Multivariate Functional Approximation Computation with Domain Decomposition Techniques⋆

Modeling large datasets through Multivariate Functional Approximations (MFA) provide an elegant way to handle many visualization and scientific analysis workflows. The process necessitates scalable data partitioning methods to compute MFA representations efficiently without compromising the accuracy or continuity of the reconstructed solution. We propose a domain -decomposed method for computing the MFA with B -spline bases, which reduces the total work per task and uses a restricted Additive Schwarz (RAS) method to converge the control point data degrees -of -freedom along subdomain boundaries. We provide an in-depth analysis of the parallel approach with domain decomposition solvers, aiming to minimize local subdomain error residuals and recover high -order continuity at subdomain interfaces with appropriate choices of knot overlaps. The communication cost, determined by the overlap regions in the RAS implementation, is optimized to recover the numerical error profile of the single subdomain case. Our proposed method stands in contrast to previous methods, which typically only recover either C 0 or at best C 1 continuity for arbitrary B -spline degree expansions, or those that require post -processing to blend discontinuities in the reconstructed data. We demonstrate the effectiveness of our approach using analytical and real -world datasets in 1D, 2D, and 3D through both strong and weak scaling studies. The performance results indicate that the overall cost of computing the approximation is directly proportional to the underlying nearest -neighbor communication implementation, and is only weakly dependent on the overlap region size that determines the size of the messages. This finding underscores the efficiency and scalability of our proposed method, making it a promising solution for handling large datasets in scientific workflows.

additive Schwarz solvers↗