At least 811 records · Page 45

Analysis of the Frequency of Extreme Precipitation Events at Los Alamos National Laboratory

The Environmental Protection and Compliance (EPC) Storm Water Permitting and Compliance Program is currently updating its stormwater compliance standards for the Los Alamos National Laboratory (LANL) Engineering Standards Manual (2015) and is addressing the required current meteorological data needed for storm water applications. Information on the frequency of extreme precipitation events at LANL is needed. In response to this request, LANL Meteorology & Air Quality (MAQ) was tasked to estimate the frequency of extreme precipitation events. An earlier study by Foley (2012) which estimated extreme precipitation rates at LANL for a set of duration periods and average recurrence intervals (return periods) was evaluated. However, it was determined that this study would not be helpful since its technical support documentation was unavailable and the meteorological data and the methodology employed were not well understood. This led to the need to develop a new peer-reviewed methodology. This report documents the development of the new methodology and the application of a temporally representative precipitation dataset from February 1990 through December 2018, monitored at the official LANL meteorological station, Technical Area (TA)-6, to develop the frequency of extreme precipitation events.

54 ENVIRONMENTAL SCIENCES↗

University of Wisconsin-Madison Campus-Wide Deep Dive

In June 2019, staff members from the Engagement and Performance Operations Center (EPOC) and the University of Wisconsin–Madison Division of Information Technology (UW DoIT) met with researchers for the purpose of a Campus-Wide Deep Dive. The goal of this meeting was to help characterize the requirements for a number of research and educational activities, and to enable cyberinfrastructure support staff to better understand the needs of researchers. Material for this event includes both the written documentation from nine projects, and the campus technology organization, but also a writeup of the discussion that took place in person. The Case Studies highlighted the ongoing challenges that the University of Wisconsin–Madison will face in the coming years to support, encourage, and grow several emerging and established use cases. The University of Wisconsin–Madison received an NSF award to help support upgrading the campus network in 2012, specifically to include a Science DMZ and monitoring equipment. However, there is a currently identified need to refresh equipment and identify and work more closely with current campus researchers. Updates to the state network, as well as the campus, are being planned and were discussed during this event. As part of the overall review, the necessity of working more closely with research teams as they are still in the planning phase was discussed so that DoIT can better understand and adapt to changes in requirements as the research demands grow over time . Additional challenges with securing sensitive data, cybersecurity, and supporting collaborations were also discussed.

97 MATHEMATICS AND COMPUTING↗

Demonstration of μCHP in Light Commercial Hot Water Applications

Internal combustion engine driven combined heat and power (CHP) systems produce power while the waste heat is recovered and used for another purpose. For µCHP systems (less than 50kWe output) overall efficiencies can reach over 90% for products currently on the market throughout the world. On a fuel basis this offers an advantage over using grid-based power and another fuel for heat. Additionally, the cost of natural gas on an energy unit basis is significantly less expensive than electric power. This difference can lead to substantial savings for the end user of a CHP system. In some parts of the world, particularly Germany and Japan, µCHP has become a common part of the heat and distributed generation equipment mix. Market analysis conducted in 2012 showed that in North America there is potential of a 5,300 units per year market for µCHP, resulting in an annual energy savings of approximately 13.5 TBtu and more than $84 million in annual customer savings. However, µCHP still has not seen much market penetration in North America. This study helps to identify some of the reasons why, address roadblocks that still need to be overcome and provide experience to established best practices. Nine commercial sites were initially identified (fitness club, surgical center, senior community, resort and spa, commercial laundry, two multi-family housing, restaurant and manufacturing facility). Systems from two different manufacturers were installed at five sites total, but due to unforeseen circumstances, only three of those sites were finally commissioned: test data were collected by Oak Ridge National Laboratory. While not all systems were installed as intended, the project resulted in the following key findings: Micro combined heat and power is an unfamiliar technology for building owners and plumbing and electrical contractors that serve the buildings most suited for µCHP. Manufacturers will need to be aggressive in providing training and providing broad support to successfully bring the technology to market.; The proper integration of µCHP into other building systems is the most critical part of a successful installation. Manufacturers will need to be able to provide the expertise to train, advise and support the mechanical contractors during the design and installation of the heat integration system.; Regulations governing µCHP varies across the country. There are a few UL standards (UL 2200 and UL 1741) that apply nationally. Emissions are governed by EPA except in California where the California Air Resources Board (CARB) has established their own standard. Requirements that dictate installation and interconnection are dependent on local building codes and local utility processes and requirements. Some out of date building codes do not offer clear guidance for these requirements, leading to confusion. This makes developing training and determining broadly applicable best practices difficult.; Installation costs of µCHP are a key factor in making an installation successful. It is critical that these costs and all national, state and local regulations be understood and accounted for by all parties involved in the installation before a project is undertaken.; A robust customer service organization is important to meet the needs of the customers. These systems require annual maintenance and service and local capability is needed to keep costs inline.

03 NATURAL GAS↗

A Summary of the UCLA HANE-Laser Experiment: 2011-2020

In the early years of this century, there was renewed interest at DTRA in artificial radiation belts, the dynamics of high altitude nuclear explosions that produced them, the development of large-scale kinetic plasma computer models at LLNL and LANL (particularly in the form of “hybrid” {i.e., particle ions, massless fluid electrons} algorithms), and the building of a laser facility at UCLA, under the direction of Prof. Niemann, which was connected to the Large Plasma Device (LAPD), a DOE user facility. These advances sparked the idea for a new laser experimental program to examine early-time HANE issues, reviving the concept from a former program at NRL in the 90’s. The basic motivation for this new effort can be traced back to the first DTRA artificial radiation belt workshop at Stanford in 2009. Subsequent discussions then led to a formal proposal from UCLA that was submitted to DTRA (Grant Jones) in 2010, vigorously reviewed, and finally approved in 2011, with funding begun in 2012. An historical perspective of this development process was presented at a DTRA review last year. In this document we review and summarize the major achievements of the DTRA-sponsored UCLA HANE-laser experiment over the past eight years. Our purpose is to briefly describe the major achievements of this program, as documented in the included extensive list of journal publications [which does not include all the publications nor any of the many invited and contributed presentations of the UCLA group], the role of the national laboratories in this effort, and how this work has impacted (and will continue to improve) our understanding of high altitude nuclear events.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Human-System Interface Design Review Guidelines

The U.S. Nuclear Regulatory Commission (NRC) staff reviews the human factors engineering (HFE) aspects of nuclear power plants in accordance with the Standard Review Plan (NUREG-0800, Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants: LWR Edition). The Human Factors Engineering Program Review Model (NUREG-0711, Revision 3, issued November 2012) contains detailed design review procedures. As part of the review process, the interfaces between plant personnel and the plant's systems and components are evaluated for conformance with HFE guidelines. This document, Human-System Interface Design Review Guidelines (NUREG-0700, Revision 3), provides the guidelines necessary to perform this evaluation. The review guidelines address the physical and functional characteristics of human-system interfaces (HSIs). Because these guidelines only address the HFE aspects of design and not other related considerations, such as instrumentation and control and structural design, they are referred to as HFE guidelines. In addition to the review of actual HSIs, the NRC staff can use the NUREG-0700 guidelines to evaluate a design-specific HFE guidelines document or style guide. The HFE guidelines are organized into four basic parts, which are divided into sections. Part I contains guidelines for the basic HSI elements: information displays, user-interface interaction and management, and analog displays and controls. These elements are used as building blocks to develop HSI systems to serve specific functions. Part II contains the guidelines for reviewing the following HSI systems: alarm system, safety parameter display system, group-view display system, soft control system, computer-based procedure system, automation system, and communication system. Part III provides guidelines for the review of workstations and workplaces. Part IV provides guidelines for the review of HSI support (i.e., maintainability of digital systems and degraded HSI and instrumentation and control conditions).

42 ENGINEERING↗

Evaluation of High Vacuum Pump for Tritium Service

In tritium process systems, vacuum pumps are typically used to evacuate volumes and piping, as well as transfer gas to other parts of the process. This was done using the combination of an all-metal scroll pump with a metal bellows backing pump. The all-metal scroll pump, manufactured by Normetex, has been unavailable since 2012, and efforts continue to find a suitable replacement. The main obstacle is finding a pump that has no oils or polymer components, which degrade when exposed to tritium and introduce corrosive and/or hazardous impurities into the process. Since turbomolecular pumps are used in tritium processing, it is thought that pumps similar to the turbomolecular pumps would be of interest. A newer model turbomolecular pump with a variable rotation speed has been identified for use in tritium processing. The turbomolecular pump, backed by a Metal Bellows MB-601 pump with the pump heads in series, was characterized for static and gas flow conditions to determine the suction pressure at various discharge pressures or flow rates for various gases.

42 ENGINEERING↗

Ninth International Workshop on Chiral Dynamics, 2018

The Ninth International Workshop on Chiral Dynamics (CD18) was hosted by the Triangle Universities Nuclear Laboratory (TUNL) and held on the campus of Duke University in Durham, NC. The workshop was from September 17 th to 21 st , 2018. This series of workshops, which started at MIT in 1994, brings together theorists and experimentalists every three years to discuss the status and challenges in the physics of low-energy quantum chromodynamics (QCD), Goldstone Boson dynamics, meson-baryon interactions, few-body physics, lattice QCD and Chiral Perturbation Theory. The last workshop was jointly hosted by the Department of Physics of the University of Pisa and the Pisa branch of the Istituto Nazionale di Fisica Nucleare in July 2015. Previous hosts of the workshop include MIT in 1994, the University of Mainz in 1997, Jefferson Lab in 2000 and 2012, the University of Bonn in 2003, TUNL and Duke University in 2006, and the University of Bern in 2009. Hosting this workshop is an important and substantial service to the international low-energy QCD physics community. Nearly 120 participants attended the workshop, which delivered twenty plenary talks, and over ninety parallel presentations. Proceedings of the workshop are published in Proceedings of Science at https://pos.sissa.it/317/. These proceedings present topics convened in this 9 th workshop and provide a comprehensive review of the field, highlighting recent accomplishments and discussing challenges that will motivate research in the coming years.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Site Environmental Report for Sandia National Laboratories California (2019)

Sandia National Laboratories, California (SNL/CA) is a Department of Energy (DOE) facility. The management and operations of the facility are under a contract with the DOE's National Nuclear Security Administration (NNSA). On May 1, 2017, the name of the management and operating contractor changed from Sandia Corporation to National Technology & Engineering Solutions of Sandia, LLC (NTESS). The DOE, NNSA, Sandia Field Office administers the contract and oversees contractor operations at the site. DOE and its management and operating contractor for Sandia are committed to safeguarding environmental protection, compliance, and sustainability and to ensuring the validity and accuracy of the monitoring data presented in this Annual Site Environmental Report. This Site Environmental Report for 2019 was prepared in accordance with DOE Order 231.1B, Environment, S afro and Health &potting (DOE 2012). The report provides a summary of environmental monitoring information and compliance activities that occurred at SNL/CA during calendar year 2019, unless noted otherwise. General site and environmental program information is also included.

54 ENVIRONMENTAL SCIENCES↗

Tracer gas test in Net-Zero Energy Residential Test Facility

The Net-Zero Energy Residential Test Facility (NZERTF) at NIST was built in 2012 to support the development and adoption of cost-effective net-zero energy designs, technologies, and construction methods. It is two-story, and has four bedrooms, three bathrooms, and an open living room, dining room, and kitchen space. The NZERTF also has a basement and attic, both located within the conditioned space because the thermal and air-moisture barriers encompass the basement walls and attic roof. Transfer grilles link the living spaces to these two zones. The central heating and cooling system includes an air-toair heat pump, which delivers air to the basement, first and second floors. The heat pump has a cooling capacity of 7.6 kW and a heating capacity of 7.8 kW. The indoor unit is in the basement and ductwork runs along the basement ceiling. A balanced heat recovery ventilator (HRV) is installed in the basement and has its own dedicated ductwork. The HRV supplies 47 L/s of outdoor air to the house, with supplies on the first floor (in the kitchen/dining area) and in each of the three second-floor bedrooms. Air from the first-floor bathroom and both second-floor bathrooms is returned to the HRV before being exhausted, though the HRV was turned off during the tests. The house also has a range hood exhaust and a clothes dryer exhaust, both of which were turned off for the tests. The temperature of the house was measured and the operation of the space conditioning system, including its recirculating air distribution fan, were controlled by a commercially available thermostat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empirical Validation of Multi-Zone HVAC System Model: Evaluation of Existing Infiltration Models used in Building Energy Simulation

Infiltration can have a significant impact on building loads. Studies have shown that infiltration can account for 15-40% of annual space conditioning needs in commercial buildings (Emmerich et al. 2019; Younes et al. 2012). The driving force of infiltration is the pressure difference across the building envelope caused by wind, the stack effect (known as buoyancy effect), and the operation of ventilation equipment. Wind pressure is governed by wind direction, speed, building shape, and other structures around the building. The stack effect is a function of the building height and air density differences of ambient air (Han, 2015). The effect of wind is dominant in low-rise residential buildings, and the stack effect is dominant in highrise buildings (ASHRAE 2017). In building energy simulation programs (e.g., EnergyPlus), various empirical infiltration models (e.g., the effective leakage area model, the flow coefficient model) are available to simulate infiltration rates. To help users in selecting a proper infiltration model for modeling of the two-story Flexible Research Platform (FRP), the team evaluates the existing infiltration models in EnergyPlus based on field measurements from the FRP. The blower door and tracer gas decay tests were performed in the FRP. The blower door test result was used to estimate input parameters required in the infiltration models. The actual infiltration rates were estimated with the tracer gas decay test results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Survey of PFAS Treatment Technologies

Per- and polyfluoroalkyl substances (PFAS) are a group of manufactured chemicals that have caught the attention of many governmental agencies and researchers. These chemicals are highly stable and possess hydrophobic properties that lead to the widespread use of PFAS in aqueous film forming foams, and household products such as carpets, paper and non-stick cookware (Prevedouros et al., 2006). Regulatory and health advisories have focused determining a lifetime drinking water health advisory of 70 ng/L for PFOA and PFOS (USEPA, 2016). Other PFASs may be present in the environment, along with PFOA and PFOS, due to product manufacturing processes (Prevedouros et al., 2006). A variety of proprietary AFFF formulations were manufactured and sold during different timeframes, thereby complicating the signature and distribution of PFASs in groundwater beneath former firefighting training areas (McGuire et al., 2014). PFOA and PFOS are stable chemicals that persistent in the environment and are difficult to remediate. The understanding of the physicochemical properties and fate and transport of PFASs in groundwater is growing but is still limited (USEPA, 2012). Many traditional approaches such as coagulation and conventional water treatment are ineffective in treating PFOA and PFOS. Selecting the most appropriate remedial strategy for PFOA and PFOS is therefore challenging. In this survey findings from the literature on PFASs removal using various technologies were compiled.

54 ENVIRONMENTAL SCIENCES↗

Update of Emission Factors of Greenhouse Gases and Criteria Air Pollutants, and Generation Efficiencies of the U.S. Electricity Generation Sector

The last decade has seen a steady evolution of the electricity generation sector. Fuels used for electricity generation have shifted from coal to cleaner energy sources such as natural gas and renewables including solar, wind, and other renewable sources. The share of U.S. electricity generated from coal decreased from 45% in 2010 to 24% in 2019, and is expected to decrease further to 13% by 2050. The conversion efficiency of electricity generation has also increased gradually for fuels such as natural gas due as less-efficient old generators are retired and more-efficient generators replace them. These changes in the electricity generation industry are likely to cause changes in the emissions from power generation units. Emission factors of greenhouse gases (GHG) including CO 2 , CH 4 , and N 2 O, and criteria air pollutants (CAPs) including CO, NO x , PM 10 , PM 2.5 , and SO x , from power plants are important parameters for estimating life-cycle emissions associated with vehicle electrification, energy systems, and the production of materials and chemicals. The electricity generation technologies and associated emission factors in the Greenhouse Gases, Regulated Emissions, and Energy Use in Technologies (GREET) model need to be updated to reflect recent developments in the electricity generation sector. The most recent update of the electricity generation emission factors in GREET adopted a mixed method. The emission factors of CH 4 , N 2 O, NO x , and SOx were estimated using a “topdown” approach by dividing the total emissions by the total net electricity generation, because emission data of these pollutants are readily available in the Emissions & Generation Resource Integrated Database (eGRID). For other CAPs such as CO, VOC, PM 10 , and PM 2.5 , emission data were not reported in eGRID. A “bottom-up” method was used to estimate the emission factors for these pollutants by considering generic uncontrolled emission factors and the pollutant removal efficiencies of emission control technologies adopted in the electricity generation sector. However, the uncontrolled emission factors and the emission removal efficiencies of various emission control technologies considered in the 2012 study came from the legacy AP-42 emission factors, and may not reflect the actual emission performances of the electricity generation sector of today. To leverage new data that recently became available, especially emission data measured from continuous emission monitoring systems (CEMS), we developed a new “top-down” approach to estimate efficiencies and GHG and CAP emission factors for electricity generation from combustion of individual fuel types by individual combustion technologies on the basis of power-generation data from U.S. Energy Information Administration’s (EIA’s) form EIA-923, and plant emission data from Environmental Protection Agency’s (EPA’s) Clean Air Markets Division (CAMD) dataset and National Emissions Inventory (NEI) dataset. Detailed discussion of the method and data used in this study can be found in Section 2.1. With this topdown approach, we aim to improve the estimates of energy efficiencies and emission factors for power plants using a more consistent methodology, and to update the emission factors, generation efficiencies, and generation technologies mixes in GREET to reflect recent technology advancements in the electricity generation sector.

20 FOSSIL-FUELED POWER PLANTS↗

Destructive PIE and Safety Testing of Six AGR-2 UO 2 Capsule 3 Compacts

The Advanced Gas Reactor (AGR) Fuel Development and Qualification Program’s second irradiation experiment (AGR-2) was irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) from June 2010 to October 2013 (Collin 2014). The fuel compacts in this experiment held either tristructural isotropic (TRISO)-coated spherical kernels of uranium oxide (UO2) or TRISO-coated kernels containing both uranium carbide and uranium oxide phases (UCO). There were six separately monitored and controlled capsules in the AGR-2 test train. Capsule 3 held twelve compacts containing UO2-TRISO particles fabricated by BWX Technologies Nuclear Operations Group. The AGR-2 TRISO particles were fabricated in a pilot-scale fluidized-bed chemical vapor deposition (FB-CVD) furnace with a coating chamber inner diameter of 150 mm (Phillips, Barnes, and Hunn 2010), which was a change from the first irradiation experiment (AGR-1) particles that had been coated in a lab-scale FB-CVD coating system with a chamber inner diameter of 50 mm (Lowden 2006). The TRISO particles were overcoated with resinated graphite flake at Oak Ridge National Laboratory (ORNL), and the overcoated particles were pressed into one-inch-long, half-inch-diameter cylinders (Hunn, Montgomery, and Pappano 2010). Each cylindrical compact held an average of 1,543 TRISO particles with 9.6% enriched UO2 kernels that had a nominal diameter of 500 μm (Hunn, Savage, and Silva 2012). Capsule 3 compacts were irradiated to average calculated burnups of 9.01–10.69% fissions per initial metal atom (FIMA), and the average calculated fluences of fast neutrons with energies E n > 0.18 MeV were 3.05–3.53×10 25 n/m 2 (Sterbentz 2014). The calculated time-average, volume-average Capsule 3 compact temperatures were 996–1,062°C. However, Capsule 3 compact temperatures varied several hundred degrees across each compact, and the timeaverage minimum (TA min ) and time-average maximum (TA max ) temperatures were between 889–999°C and 1,072–1,105°C, respectively (Hawkes 2014). After irradiation, the AGR-2 test train was transferred from ATR to the INL Materials and Fuels Complex for inspection and disassembly (Ploger, Demkowicz, and Harp 2015). The initial inspection included dimensional metrology of the compacts and graphite fuel holders. Like all the AGR-2 compacts, the compacts in Capsule 3 shrank slightly during irradiation, as expected, with an average length reduction of 1.07–1.24% and an average diameter reduction of 0.13–0.41%. Post-irradiation examination (PIE) of the capsule components was completed to measure select fission products ( 90 Sr, 110m Ag, 134 Cs, 137 Cs, 144 Ce, and 154 Eu) outside the compacts (Stempien and Demkowicz 2020). This involved gamma counting of the graphite and graphoil spacers at the top and bottom of each capsule, acid leaching for radiochemical analysis of fission products on the metallic capsule components, and burn-leach analysis of the graphite holders. The total amount of 110mAg measured on the Capsule 3 components was 13% of the calculated capsule inventory. This was significantly lower than the amount of 110m Ag measured on the three UCO capsule components, which ranged from 32–70%. The lower 110m Ag release in Capsule 3 was likely due to lower peak temperatures compared with the UCO fuel capsules (Hawkes 2014). Measured inventories of the other select fission products were also lower in Capsule 3.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rheology and Flow Evaluation of Neutralized Sodium Reactor Experiment Fuel with Manganous Nitrate

H-Canyon is preparing the Sodium Reactor Experiment (SRE) solutions in Tanks 16.3 and 16.4 for discard to the Savannah River Site (SRS) High Level Waste (HLW) Tanks into Sludge Batch (SB) 10. To meet HLW's criticality requirements, manganese will be added to the SRE solutions. The addition of manganese to the existing thorium and uranium in the SRE solution raised concerns with the flow of this neutralized material as it is discharged from H-Canyon through the gravity drain system to the H-Area Pump Pit (HPP). A neutralized Mn adjusted SRE stream will produce primarily Mn, Th, and U solids that can deter transfer. A 2012 rheology study was completed as part of the flowsheet development.1 However, the initial rheology study did not include the addition of manganous nitrate as a poison. Therefore, H-Canyon Engineering requested Savannah River National Laboratory (SRNL) to determine if the neutralized, Mn-adjusted SRE solutions will flow through the waste header to the HPP. The H-Canyon Technical Task Request (TTR) specified a target of 80 to 1 to bound the uncertainty in Mn target. Parallel studies were being performed to ensure that freshly precipitated Mn did not have a solubility that would result in challenging the DWPF WAC requirements of 70 to 1. This task was requested via a TTR and is governed by a Task Technical and Quality Assurance Plan (TTQAP).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-frequency and Vertical Variations of Soil Moisture and their Impact on Ecosystem Dynamics

The vertical distribution of subsurface moisture is a major control on ecosystem dynamics and climate. The Mediterranean climate of California, with wet winters and dry summers, provides a testbed for understanding how transpiration is sustained through extended dry periods. The project developed and tested a new subsurface hydrology model that includes a parameterization of stochastic hydraulic conductivity to capture fracture flow, a diagnostic model of rooting profile that depends on the subsurface hydrology, and a representation of hydraulic redistribution by plant roots. A sensitivity study shows that it is plants with rooting depths >8 m that could access the subsurface moisture. The insight is applied to understand differential tree mortality during the 2012-2016 drought in California. The analysis shows that greater mortality trees on plutonic rocks than on sedimentary rocks. The study demonstrates, for the first time, the importance of lithology for the distribution and health of ecosystems.

54 ENVIRONMENTAL SCIENCES↗

Use of Remote Sensing and In-Situ Observations to Develop and Evaluate Improved Representations of Convection and Clouds for the ACME Model

The overachieving goal of the whole CMDV-MCS project is to improve understanding of warm season continental convection and to develop treatments of convection and microphysics capable of representing mesoscale convective systems (MCSs) features in large-scale models. Our tasks for this project contributing to the overachieving goal include: (1) Improve the ice nucleation formulation for MG2 and P3 cloud microphysics schemes; (2) Improve the treatment of subgrid dynamics and thermodynamics driving the ice nucleation in E3SM; and (3) Test the performance of improved ice microphysics in E3SM with observation data. In this project, we have (1) Improved the ice nucleation parameterization for MG2 and P3 in E3SM by implementing two advanced empirical parameterizations with connection to aerosols. The two deterministic heterogeneous ice nucleation parameterizations (i.e., DeMott et al., 2015; Niemand et al., 2012) were merged with the MG2 and P3 cloud microphysics schemes in E3SM. Long-term simulations were conducted to examine the impacts of these new parameterizations on simulated cloud properties; (2) Improved the treatment of subgrid dynamics and thermodynamics driving the ice nucleation in E3SM. We evaluated the double Gaussian PDF of vertical velocity simulated by the Cloud Layers Unified By Binormals (CLUBB) and the sub-column vertical velocity sampled from the Subgrid Importance Latin Hypercube Sampler (SILHS) in E3SM. We introduced the vertical velocity variance induced by topographic gravity waves for ice nucleation and droplet activation; and (3) Tested the performance of improved ice microphysics in E3SM with observation data. We tested the new treatments of ice nucleation in the single column model (SCM) mode for the stratiform mixed-phase clouds observed during 9-10 October 2004 in the DOE ARM Mixed-Phase Arctic Cloud Experiment (M-PACE) and for the convective clouds observed on 20 May 2011 in the Midlatitude Continental Convective Clouds Experiment (MC3E). Modeled ice nucleating particles (INPs) concentrations were compared against observations collected around the globe.

54 ENVIRONMENTAL SCIENCES↗

SnRK1-ZmRFWD3-Opaque2: A Nexus of Seed Nutrient Accumulation and Diurnal Cycles

Plant seeds store nutrients in the form of protein, starch, and oil to support seed germination and seedling establishment. The seed nutrient reserves are supplied with carbon and nitrogen assimilated in vegetative tissues, where primary metabolism oscillates in a circadian manner (Farré and Weise, 2012). However, whether the nutrient accumulation in developing seeds is also tuned during the diurnal cycle remained unclear until now. In a recent study, Li et al. (2020) identified a signaling module at the nexus between nutrient accumulation in maize (Zea mays) seed and the diurnal cycle.

59 BASIC BIOLOGICAL SCIENCES↗

Brief Update on Advancements by Commercial Vendors/Options for Feeding and Pumping Biomass Slurries for Hydrothermal Liquefaction

In 2011, Pacific Northwest National Laboratory (PNNL), working as a partner in the National Advanced Biofuels Consortium, issued a report assessing the viable industrial feed system and pump options for a 2000 dry metric tons per day production-scale hydrothermal liquefaction (HTL) plant (Berglin et al. 2012). This report was issued as PNNL-21981, Review and Assessment of Commercial Vendors/Options for Feeding and Pumping Biomass Slurries for Hydrothermal Liquefaction, and will be referred to as “Pump Survey” for reference. It had the following scope: • Identify relevant applications and industries operating at comparable scales • Interact with commercial vendors and pursue integration between vendors • Take advantage of commercial off-the-shelf (COTS) technology • Supply and support vendor needs for biomass feedstock rheology characterization • Provide vendors with process requirements to support selection of conceptual design for feedstock handing and pump system • Obtain cost data to the extent possible from equipment vendors to support the technical economic analysis (TEA) • Identify issues associated scale-up. The current document represents an update to the prior report in order to: 1. Identify advancements in vendor-reported technologies 2. List reports of new experience or trials with biomass pumping applications 3. Determine if technology/application gaps identified in the prior report have been filled 4. Capture ideas on future research.