Electric sector impacts of renewable policy coordination: A multi-model study of the North American energy system
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Two-dimensional transition metal dichalcogenides (TMDs)-based memristors are promising candidates for realizing artificial synapses in next-generation computing. However, practical implementation faces several challenges, such as high non-linearity and asymmetry in synaptic weight updates, limited dynamic range, and cycle-to-cycle variability. Here, utilizing optimal-power argon plasma treatment, we significantly enhance the performance matrix of memristors fabricated from monolayer MoS 2 . Our approach not only improves linearity and symmetry in synaptic weight updates but also increases the number of available synaptic weight updates and enhances Spike-Time Dependent Plasticity. Notably, it broadens the switching ratio by two orders, minimizes cycle-to-cycle variability, reduces non-linear factors, and achieves an energy consumption of ~30 fJ per synaptic event. Implementation of these enhancements is demonstrated through Artificial Neural Network simulations, yielding a learning accuracy of ~97% on the MNIST hand-written digits dataset. Our findings underscore the significance of defect engineering as a powerful tool in advancing the synaptic functionality of memristors.
The Excel-based CHECT tool estimates the LCOC ($/kWh) by charger type (Level 1, Level 2, and DC fast charging) for a given charging hub scenario. CHECT requires users to input certain charging hub scenario parameters, including the number of chargers, daily utilization, and charger replacement frequency by charger type. Additional inputs such as the charging schedule, local utility rates, capital/operational costs, and financial inputs can be customized by the user, or the tool can generate results using appropriate default values from literature for the charging hub scenario and service location(s). Using the above inputs, CHECT performs a robust techno-economic analysis to generate the LCOC by charger type, broken down by cost category (e.g., capital, operational, utility, taxes) for various combinations of charging hub types (multiunit dwelling or public) and ownership models (residential, utility, or private company). It also outputs the annual discounted cash flows and determines the most sensitive input variables. In addition, the tool allows users to easily compare the LCOC across various ownership models or across different states.
Atmospheric carbon dioxide (CO 2 ) plays a key role in the global carbon cycle and global warming. Climate-carbon feedbacks are often studied and estimated using Earth System Models (ESMs), which couple together multiple model components—including the atmosphere, ocean, terrestrial biosphere, and cryosphere—to jointly simulate mass and energy exchanges within and between these components. Despite tremendous advances, model intercomparisons and benchmarking are aspects of ESMs that warrant further improvement (Fer et al., 2021; Smith et al., 2014). Such benchmarking is critical because comparing the value of state variables in these simulations against observed values provides evidence for appropriately refining model components; moreover, researchers can learn much about Earth system dynamics in the process (Randall et al., 2019). We introduce `gdess` (a.k.a., Greenhouse gas Diagnostics for Earth System Simulations), which parses observational datasets and ESM simulation output, combines them to be in a consistent structure, computes statistical metrics, and generates diagnostic visualizations. In its current incarnation, `gdess` facilitates evaluating a model's ability to reproduce observed temporal and spatial variations of atmospheric CO 2 . The diagnostics implemented modularly in `gdess` support more rapid assessment and improvement of model-simulated global CO 2 sources and sinks associated with land and ocean ecosystem processes. We intend for this set of automated diagnostics to form an extensible, open source framework for future comparisons of simulated and observed concentrations of various greenhouse gases across Earth system models.
We consider a route planning problem in which two unmanned vehicles are required to complete a set of tasks present at distinct locations, referred to as targets, with minimum energy consumption. The mission environment is hazardous, and to ensure a safe operation, the UVs are required to communicate with each other at every target they visit. The problem objective is to determine the allocation of the tasks to the UVs and plan tours for the UVs to visit the targets such that the weighted sum of the distances traveled by the UVs and the distances traveled by the communicating signals between them is minimized. We formulate this problem as an Integer program and show that naively solving the problem using commercially available off-the-shelf solvers is insufficient in determining scalable solutions efficiently. To address this computational challenge, we develop an approximation and a heuristic algorithm, and employ them to compute high-quality solutions to a special case of the problem where equal weights are assigned to the distances traveled by the vehicles and the communicating signals. For this special case, we show that the approximation algorithm has a fixed approximation ratio of 3.75. We also develop lower bounds to the optimal cost of the problem to evaluate the performance of these algorithms on large-scale instances. We demonstrate the performance of these algorithms on 500 randomly generated instances with the number of targets ranging from 6 to 100, and show that the algorithms provide high-quality solutions to the problem swiftly; the average computation time of the algorithmic solutions is within a fraction of a second for instances with at most 100 targets. Finally, we show that the approximation ratio has a variable ratio for the weighted case of the problem. Specifically, if ρ denotes the ratio of the weights assigned to the distances representing the communication and travel costs, the algorithm has an a posteriori ratio of $3 + \frac{3ρ}{4}$ when ρ ≥ 1, and $\frac{3}{ρ}$ + $\frac{3}{4}$ when ρ ≤ 1.
Distributed energy resources (DERs), including rooftop solar, energy storage, and flexible loads, are gaining popularity as costs decline and as building owners and utilities realize their benefits. DERs can improve distribution system efficiency, help prevent the need for expensive grid upgrades, and increase the resilience of local communities. However, they can also cause difficulties in grid operations and can require controls to achieve their benefits. To address this challenge, NREL researchers have developed a community-scale solution that assesses the impacts of DERs and their control strategies on a distribution system. The framework has been shown to reduce solar photovoltaic (PV) curtailment to 0%, mitigate the adverse impact of solar variability on the distribution voltage, and provide up to 5-day critical load support during emergency events. Utilizing 5 different modules representing the feeder, buildings, home energy management systems, an aggregator, and a utility controller, NREL expects this simulation technology to play a critical role in the continued integration of DERs. According to the Energy Information Administration (EIA), solar curtailments accounted for 94% of the total energy curtailed in the California Independent System Operator (CAISO) in 2020. By enabling Independent System Operators (ISOs) and utility operators to bring solar curtailments to 0%, the electrical grid can become less dependent on fossil-fueled power generation sources. NREL's co-simulation framework contains five major components: Distribution Feeder Model: describes the distribution feeder topology using OpenDSS, including the locations of all DERs. Residential Building Model: simulates a large number of buildings at a high resolution using OCHRETM. The model is equipped to control equipment based on signals from an external module. The model includes major household appliances such as HVAC and a water heater, non-dispatchable load models, a distributed PV system, and a home battery system. Home Energy Management System: optimizes the controls for the devices in a home using foreseeTM. The control can adjust based on the user preferences including cost, comfort, and convenience. In hierarchical control scenarios, where the houses follow signals from an aggregator, the home energy management system provides a flexibility band with a range of power and follows the dispatch signals received from aggregator. Community-Level Aggregator: solves for optimal energy dispatch based on the flexibility bands received from each home and the grid service signal received from the utility controller. Utility-Level Controller: provides grid signals for voltage control using Distributed Energy Resources (DERs), such as solar systems, in the community.
A fault detection and diagnostics (FDD) tool is a type of energy management and information system designed to continuously identify the presence of faults and efficiency improvement opportunities through a one-way interface to the building automation system and application of automated analytics. Building owners and operators at the leading edge of technology adoption are using FDD tools to enable average whole-building portfolio savings of 8 percent. Although FDD tools can inform building operators of operational faults, currently a manual action is always required to correct faults and generate the associated energy savings. A subset of faults, however, such as biased sensors and manual override, can be addressed automatically, removing the need for operations and maintenance staff intervention. Automating this fault “correction” can significantly increase the savings generated by FDD tools and reduce the reliance on human intervention. Doing so is expected to advance the usability, as well as the technical and economic performance, of FDD technologies. In this paper, we present the development of 10 innovative fault auto-correction algorithms for HVAC and lighting systems. When the auto-correction routine is triggered, it will overwrite the control setpoints or other variables (via BACnet or other protocol) to implement the intended changes. These algorithms are able to automatically correct the faults or improve the operation associated with an incorrectly programmed schedule, override manual control, sensor bias, control hunting, rogue zone, and less aggressive setpoints/setpoints setback. The paper will also discuss the implementation of the auto-correction algorithms in FDD software products.
With rapid growth of distributed renewable generation, the establishment of electricity distribution markets has attracted widespread concerns. Different from existing transmission grid-scale electricity markets, an electricity distribution market is featured by numerous small-scale prosumers, and zero marginal cost and intermittency of renewable generation units. Against this background, this paper first extends an average pricing market (APM) mechanism for pricing renewable generation outputs with zero marginal cost in the distribution network concerned. Then, to mitigate the uninstructed volatility of renewable generation outputs and power demand, a penalty scheme is proposed for deviations between the real-time demand/output and market cleared bid/offer, with frequency regulation service (FRS) from energy storage systems (ESSs) considered. It is proved that the market volatility can be well controlled within an expected limit through properly setting the penalty prices for load demand and generation output fluctuations. Also, with this mechanism a non-negative market surplus could always be attained. Case studies are carried out to demonstrate the feasibility and efficiency of the proposed distribution market mechanism and penalty scheme.
Cross-sections for the production of a $Z$ boson in association with two photons are measured in proton–proton collisions at a centre-of-mass energy of 13 TeV. The data used correspond to an integrated luminosity of 139 fb -1 recorded by the ATLAS experiment during Run 2 of the LHC. The measurements use the electron and muon decay channels of the $Z$ boson, and a fiducial phase-space region where the photons are not radiated from the leptons. The integrated $Z$($\rightarrow$ $\ell$$\ell$)$\gamma \gamma$ cross-section is measured with a precision of 12% and differential cross-sections are measured as a function of six kinematic variables of the $Z\gamma \gamma$ system. The data are compared with predictions from MC event generators which are accurate to up to next-to-leading order in QCD. The cross-section measurements are used to set limits on the coupling strengths of dimension-8 operators in the framework of an effective field theory.
This dataset was generated using an iterative active-learning strategy implemented in the ArcaNN software package (https://github.com/arcann-chem/arcann_training) to train machine-learning interatomic potentials for aqueous ZnCl2 solutions. Each active-learning cycle consisted of three stages: training, exploration, and labeling. The initial training set combined configurations generated in this work from enhanced-sampling ab initio molecular dynamics simulations with configurations from a previously reported neural-network-potential study of aqueous ZnCl2. The enhanced-sampling ab initio molecular dynamics simulations involved Zn–Cl separation and the chloride coordination number around Zn²? as collective variables. These configurations served as the seed dataset. Subsequent active-learning cycles expanded the training set by identifying and labeling configurations that were poorly represented by the current models, thereby improving coverage of ion-association states and changes in local coordination and charge-state environments relevant to the solution free-energy landscape. For all selected configurations, single-point calculations of the total energies and atomic forces were performed within density functional theory using the CP2K Quickstep module. Reference calculations employed the revPBE-D3 and r2SCAN exchange-correlation functionals. Motivated by recent work on aqueous Zn²?, the main revPBE calculations omitted D3 dispersion contributions involving Zn²?, while retaining the D3 correction for water and chloride. For comparison, fully dispersion-corrected revPBE-D3 reference calculations were also performed, with D3 applied to all species, including Zn²?. Valence electrons were treated explicitly, while core electrons were represented using norm-conserving Goedecker–Teter–Hutter pseudopotentials. The wave functions were expanded using the mixed Gaussian-and-plane-wave scheme with TZV2P-MOLOPT basis sets for all elements and a 600 Ry auxiliary plane-wave cutoff for the electron density. Self-consistent-field convergence was accelerated using the orbital-transformation and Direct Inversion in the Iterative Subspace algorithms, with a convergence threshold of 10?6. All single-point calculations were performed in periodic orthorhombic cells. The CELL_REF keyword in CP2K was used to define a fixed reference cell with a box length of 25 Å. This treatment ensured a consistent reference for configurations extracted from NpT trajectories with fluctuating cell dimensions. The resulting DFT energies and atomic forces constitute the ground-truth labels used to train the MLIPs. The resulting MLIP was trained for aqueous ZnCl2 solutions spanning concentrations from 0 to 30 molal and a broad pH range, from strongly acidic to strongly basic conditions. Representative examples of configurations included in the MLIP training dataset are provided below. These include 1) Representative configurations from the dataset labeled at the revPBE-D3 level, with D3 dispersion interactions involving Zn2+ excluded (revPBE-wo-D3). 2) Representative configurations from the dataset labeled at the fully dispersion-corrected revPBE-D3 level, with D3 interactions applied to all species, including Zn2+ (revPBE-D3). 3) Representative configurations from the dataset labeled at the r2SCAN level of theory (r2SCAN).
Abstract. Conservative mapping of data from one horizontal grid to another should preserve certain integral or mean properties of the original data. This may be essential in some model applications, including ensuring realistic exchange of energy and mass between coupled model components. It can also be essential for certain types of analysis, such as evaluating how far a system is from an equilibrium state. For some common grids, existing remapping algorithms may fail to perfectly represent the shapes and sizes of grid cells, which leads to errors in the remapped fields. A procedure is presented here that enables users to rely on the mapping weights generated by remapping algorithms but corrects for their deficiencies. With this procedure, for a given pair of source and destination grids, a single set of remapping weights can be applied to remap any variable, including those with grid cells that are partially or fully masked.
The growing adoption of residential distributed energy resources (DERs) introduces more uncertain variability in power grid operation. More importantly, the residential DERs operate behind customers’ energy meters, and therefore, the utility cannot “directly” monitor them. Prior approaches to enable visibility into behind-the-meter (BTM) DERs either depend on estimations or require intrusive instrumentation on the customer side. To address the critical need for direct real-time monitoring of BTM DERs, in this paper, we propose a novel approach for utility-side direct real-time monitoring of residential BTM DERs. We utilize high-frequency (> 10kHz) conducted electromagnetic interference (EMI) from residential DERs’ grid-tied inverters to monitor their power generation. We discuss the working principle of our approach and present supporting results using three of-the-shelf grid-tied inverters.
Security-constrained unit commitment (SCUC) is a key component in power system operations. When AC power flow constraints are considered in the SCUC model (AC-SCUC), the problem becomes extremely difficult due to its discrete and non-convex nature, as described in “Grid Optimization Competition Challenge 3 Problem Formulation (GOCC)”. There are four main challenges: (i) Discrete decisions regarding unit online/offline status and start-up/shut-down procedures for every single unit. The number of discrete decision variables increases considerably when a system integrates multiple generators; (ii) Configuration-based combined-cycle formulations, and multi-commodity models that include ramping products, spin/non-spin products, and regulation up/down products. The combined-cycle units introduce additional discrete decision variables and auxiliary service products further complicate the model by connecting multi-commodity products’ continuous and discrete variables; (iii) SCUC models with AC power flow constraints are far more complex due to massive bilinear terms in the large-scale nonlinear power balance equations. The nonlinear power balance equations are further complicated by the discrete step control variables of shunts; (iv) N − 1 contingency analysis. The size of the model increases linearly with the number of contingencies considered, greatly increasing the size of the optimization model. Accordingly, there is an emergent need to develop a robust algorithm capable of deriving a high-quality solution in a short time and passing through contingency tests simultaneously. In this project, we explore innovative techniques to address this challenging problem by integrating advanced polyhedral theory, approximation methods, relaxation strategies, decomposition techniques, and parallel computing. Each technique approaches the problem from a different perspective, leveraging its specific strengths to tackle distinct challenges. Each individual method has demonstrated its effectiveness in the PI’s previous research. Their integration is expected to significantly reduce the computational time required to solve the proposed complex problem. Successful completion of this project has the potential to transform the industry by enhancing optimization solvers capable of handling large-scale day-ahead energy market clearing models within strict time constraints, while incorporating AC power flow constraints. This advancement will lead to reduced overall generation costs and, consequently, increased social welfare.
Long-term planning and operation of hydropower reservoirs require an understanding of both water and energy storage. As energy storage needs of the evolving grid increase, we must account for the water and energy storage potential of these reservoirs. Given the limitations of current data on existing hydropower, we compile statistics related to storage volume and hydraulic head from publicly available data sets and examine differences in descriptions of US hydropower storage. Assembled characteristics are used to calculate nominal energy storage capacity, a simple measure of potential to generate power from a given volume of water, not factoring in detailed constraints. Inventory-based estimates of energy storage are calculated at 2,075 dams, which helps put the potential for US hydropower to support energy storage in context with similar evaluations in other regions and with other energy storage technologies. The national energy storage capacity ranges between 34.5 and 45.1 TWh depending on the information used, with 52% of energy storage located at the 10 largest reservoirs in the US. Energy storage capacities are also calculated at 236 dams with historical volume and elevation data. Finally, reservoir inflows provide context for the storage volumes and sensitivities to hydrologic variability. Larger reservoirs with greater storage volume to inflow ratios are concentrated in the Western US, but the majority of hydropower reservoirs store less than the annual inflow. We address several infrastructure and water resource informatics challenges and highlight remaining issues, including representing seasonal or shorter variability in water volumes and representing connected hydropower facilities.
This dataset include standardized phenological transition dates, and derived season lengths of active, dormant and transition seasons of ecosystem carbon and energy fluxes, as reported in FLUXNET. Such metrics are unique in that they characterize the seasonal dynamics of these fluxes in their own terms rather than in reference to traditional phenology indicators that mostly relate to vegetation structural characteristics. The Flux Seasonality Metrics Database (FSMD) generated 17 standardized seasonality metrics for 4 different fluxes including gross primary productivity (GPP), ecosystem respiration (RE), latent heat (LE) and sensible heat (H) reported in FLUXNET2015 Dataset for about 200 sites and 1500 site-years of data globally. Each metric is reported as an estimate and a confidence interval, which is a function of data coverage and flux variability. We anticipate that the FSMD will facilitate new model validation exercises, and stimulate new research in global change and Earth science disciplines where land-atmosphere exchange dynamics play a central role.
Local climate undoubtedly affects facility maintenance requirements; however, knowledge of the link between weather and facility condition over time is grounded in the 1990s and needs to be updated. WIRE aims to quantify the relationship between climate and infrastructure by calculating climate-based service life estimates to be used in BUILDER, a program the Department of Energy (DOE) uses for facility management. Phase One of this project is a case study on window-or-wall-mounted AC units. The independent variables influencing service life are load, maintenance quality, and effective age, with load calculated from three weather variables: temperature, humidity, and solar radiation. Given sufficient data, service life can be calculated as a function of these variables via regression. WIRE is currently collecting data. Preliminary estimated service life projections as a function of load derived from Lawrence Livermore National Laboratory (LLNL) data support the need for updated analysis on the relationship between climate and facility condition. With the groundwork laid, WIRE can generate deliverables immediately upon arrival of data. The methods used for this case study constitute a framework for deriving the relationship between weather variables and service life for other components.
Concentrating solar power (CSP) plants, thanks to the implementation of cost-competitive thermal energy storage, represent a dispatchable zero-emission alternative to traditional fossil fuel power plants. Next generation solar towers are expected to adopt high temperature receivers (>700 degrees C) coupled to sCO2-based power blocks, which optimal design is generally pushed towards the maximum cycle efficiency, often neglecting the economic impact with the justification that the main share of the capital cost is represented by the heliostat field. As result, the scientific literature lacks in comprehensive studies on techno-economic evaluation of CSP+sCO2 power plants addressing the important correlation that exists between system cost and performances. This work provides a preliminary techno-economic analysis of a solar power tower comparing four different cycle configurations for the sCO2 power block. Results have been reported on a Pareto front, highlighting the tradeoff between the plant investment cost and the solar-to-electricity plant efficiency. The trends of the optimization variables and cycle results have been reported to give useful insights about proper assumptions for the sCO2 power block design. The recompressed cycle with intercooling resulted as the most promising configuration and it has been further analyzed through a comparison of different solutions on the Pareto front. The cost breakdown of the sCO2 power block has been reported to highlight which components have the greatest impact on the overall plant cost and how they vary along the optimal solutions front. Eventually, the optimization has been repeated introducing a correlation to compute the turbomachinery isentropic efficiencies, to investigate their effect on the techno- economic analysis.
The Weather Research and Forecasting (WRF) Model has been extensively used for wind energy applications, and current releases include a scheme that can be applied to examine the effects of wind turbine arrays on the atmospheric flow and electricity generation from wind turbines. Herein we present a high-resolution simulation using two different wind farm parameterizations: 1) the “Fitch” parameterization that is included in WRF releases and 2) the recently developed Explicit Wake Parameterization (EWP) scheme. We compare the schemes using a single yearlong simulation for a domain centered on the highest density of current turbine deployments in the contiguous United States (Iowa). Pairwise analyses are applied to diagnose the downstream wake effects and impact of wind turbine arrays on near-surface climate conditions. On average, use of the EWP scheme results in small-magnitude wake effects within wind farm arrays and faster recovery of full WT array wakes. This in turn leads to smaller impacts on near-surface climate variables and reduced array–array interactions, which at a systemwide scale lead to summertime capacity factors (i.e., the electrical power produced relative to nameplate installed capacity) that are 2%–3% higher than those from the more commonly applied Fitch parameterization. It is currently not possible to make recommendations with regard to which wind farm parameterization exhibits higher fidelity or to draw inferences with regard to whether the relative performance may vary with prevailing climate conditions and/or wind turbine deployment configuration. However, the sensitivities documented herein to the wind farm parameterization are of sufficient magnitude to potentially influence wind turbine array siting decisions. Thus, our research findings imply high value in undertaking combined long-term high-fidelity observational studies in support of model validation and verification.