Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “uncertainty relation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

HOW LOW CAN YOU GO? THE PHOTOECCENTRIC EFFECT FOR PLANETS OF VARIOUS SIZES

It is well-known that the light curve of a transiting planet contains information about the planet's orbital period and size relative to the host star. More recently, it has been demonstrated that a tight constraint on an individual planet's eccentricity can sometimes be derived from the light curve via the ''photoeccentric effect'', the effect of a planet's eccentricity on the shape and duration of its light curve. This has only been studied for large planets and high signal-to-noise scenarios, raising the question of how well it can be measured for smaller planets or low signal-to-noise cases. We explore the limits of the photoeccentric effect over a wide range of planet parameters. The method hinges upon measuring g directly from the light curve, where g is the ratio of the planet's speed (projected on the plane of the sky) during transit to the speed expected for a circular orbit. We find that when the signal-to-noise in the measurement of g is <10, the ability to measure eccentricity with the photoeccentric effect decreases. We develop a ''rule of thumb'' that for per-point relative photometric uncertainties σ = (10{sup –3}, 10{sup –4}, 10{sup –5}), the critical values of the planet-star radius ratio are R{sub p} /R {sub *} ≈ (0.1, 0.05, 0.03) for Kepler-like 30 minute integration times. We demonstrate how to predict the best-case uncertainty in eccentricity that can be found with the photoeccentric effect for any light curve. This clears the path to study eccentricities of individual planets of various sizes in the Kepler sample and future transit surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

THE EVOLUTION OF THE ULTRAVIOLET LUMINOSITY FUNCTION FROM z {approx} 0.75 TO z {approx} 2.5 USING HST ERS WFC3/UVIS OBSERVATIONS

We present UV luminosity functions (LFs) at 1500 A derived from the Hubble Space Telescope Early Release Science WFC3/UVIS data acquired over {approx}50 arcmin{sup 2} of the GOODS-South field. The LFs are determined over the entire redshift range z = 0.75-2.5 using two methods, similar to those used at higher redshifts for Lyman break galaxies (LBGs): (1) 13 band UV+optical+NIR photometric redshifts to study galaxies in the range z = 0.5-2 in three bins of dz = 0.5 and (2) dropout samples in three redshift windows centered at z {approx} 1.5, z {approx} 1.9, and z {approx} 2.5. The characteristic luminosity dims by 1.5 mag from z = 2.5 to z = 0.75, consistent with earlier work. However, the other Schechter function parameters, the faint-end slope and the number density, are found to be remarkably constant over the range z = 0.75-2.5. Using these LF determinations, we find the UV luminosity density to increase by {approx}1.4 dex according to (1 + z){sup 2.58{+-}0.15} from z {approx} 0 to its peak at z {approx} 2.5. Strikingly, the inferred faint-end slopes for our LFs are all steeper than {alpha} = -1.5, in agreement with higher-redshift LBG studies. Since the faint-end slope in the local universe is found to be much flatter with {alpha} {approx_equal} -1.2, this poses the question as to when and how the expected flattening occurs. Despite relatively large uncertainties, our data suggest {alpha} {approx_equal} -1.7 at least down to z {approx} 1. These new results from such a shallow early data set demonstrate very clearly the remarkable potential of WFC3/UVIS for the thorough characterization of galaxy evolution over the full redshift range z {approx} 0.5 to z {approx} 3.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of the thermal and ionization state of the intergalactic medium during the cosmic afternoon

We perform the first measurement of the thermal and ionization state of the intergalactic medium (IGM) across 0.9 < z < 1.5 using 301 Ly α absorption lines fitted from 12 archival Hubble Space Telescope Space Telescope Imaging Spectrograph quasar spectra. We employ the machine-learning-based inference method that uses joint Doppler parameter–column density (⁠b-N HI ⁠) distributions obtained from Ly α forest decomposition. Our results show that the Γ HI photoionization rates, ⁠, agree with recent ultraviolet background synthesis models, with log(Γ HI /s -1 ) = $-11.79^{+0.18}_{-0.15}$, $-11.98^{+0.09}_{-0.09}$⁠, and $-12.32^{+0.10}_{-0.12}$⁠, at z = 1.4, 1.2, and 1, respectively. We obtain the IGM temperature at the mean density, T 0 ⁠, and the adiabatic index, γ⁠, as [log(T 0 /K), γ] = $[4.13^{+0.12}_{-0.10}, 1.34^{+0.10}_{-0.15}]$, $[3.79^{+0.11}_{-0.11}, 1.70^{+0.09}_{-0.09}]$, and $[4.12^{+0.15}_{-0.25}, 1.34^{+0.21}_{-0.26}]$ at z = 1.4⁠, 1.2, and 1. Our measurements of T 0 at z = 1.4 and 1.2 are consistent with the trend predicted from previous z < 3 temperature measurements and theoretical expectations, where the IGM cools down after $He\tiny{II}$ reionization in the absence of any non-standard heating. However, our T 0 measurement at z = 1 unexpectedly high IGM temperature. Given the relatively large uncertainty in these measurements, where σ T$_0$ ~ 5000 K, mostly emanating from the limited size of our data set, we cannot conclude whether the IGM cools down as expected. Lastly, we generate mock data sets to test the constraining power of future measurement with larger data sets. The results demonstrate that, with redshift path-length Δz ~ 2 for each redshift bin, three times the current data set, we can constrain the T 0 of IGM within 1500 K, which would be sufficient to constrain the IGM thermal history at z < 1.5 conclusively.

79 ASTRONOMY AND ASTROPHYSICS↗

THE MAYAK WORKER DOSIMETRY SYSTEM (MWDS-2016): INTERNAL DOSIMETRY RESULTS AND COMPARISON WITH MWDS-2013

Abstract Differences in results from the new Mayak Worker Dosimetry System (MWDS-2016) vs the previous MWDS-2013 are described. Statistical characteristics are shown for the distribution of accumulated absorbed doses to organs for 8340 workers with bioassay data. Differences in mean values of accumulated doses and their relative standard uncertainties calculated by MWDS-2016 and MWDS-2013 were analysed separately for various types of industrial compounds of plutonium, specifically nitrates, mixtures and oxides. Within the range of accumulated doses >1 mGy, lung doses for nitrates and mixtures decreased by 41 and 15%, respectively, and remained at the same level for oxides. Accumulated liver doses within the range >1 mGy increased for nitrates and mixtures by 13 and 8%, respectively, and decreased for oxides by 7%.

Vostrotin, Vadim V.↗

Generalized geometric speed limits for quantum observables

Leveraging quantum information geometry, we derive generalized quantum speed limits on the rate of change of the expectation values of observables. These bounds subsume and, for Hilbert space dimension ≥3, tighten existing bounds—in some cases by an arbitrarily large multiplicative constant. Our theoretical results are supported by illustrative examples and an experimental demonstration using a superconducting qutrit. We also derive two upper bounds on the generalized quantum Fisher information in terms of the condition number of the density matrix. One of these bounds applies only to coherent dynamics and depends also on the variance of the Hamiltonian. The other bound depends also on the so-called Wigner-Yanase skew information. These bounds generalize well-known bounds on the symmetric logarithmic derivative quantum Fisher information and are tighter than the existing bounds for sufficiently mixed states (e.g., for sufficiently high temperature thermal states).

open quantum systems & decoherence↗

Mass measurements in the vicinity of the r p-process and the {nu} p-process paths with the Penning trap facilities JYFLTRAP and SHIPTRAP

The masses of very neutron-deficient nuclides close to the astrophysical r p- and {nu} p-process paths have been determined with the Penning trap facilities JYFLTRAP at JYFL/Jyvaeskylae and SHIPTRAP at GSI/Darmstadt. Isotopes from yttrium (Z=39) to palladium (Z=46) have been produced in heavy-ion fusion-evaporation reactions. In total, 21 nuclides were studied, and almost half of the mass values were experimentally determined for the first time: {sup 88}Tc, {sup 90-92}Ru, {sup 92-94}Rh, and {sup 94,95}Pd. For the {sup 95}Pd{sup m}, (21/2{sup +}) high-spin state, a first direct mass determination was performed. Relative mass uncertainties of typically {delta}m/m=5x10{sup -8} were obtained. The impact of the new mass values has been studied in {nu} p-process nucleosynthesis calculations. The resulting reaction flow and the final abundances are compared with those obtained with the data of the Atomic Mass Evaluation 2003.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Penning trap mass measurements of {sup 99-109}Cd with the ISOLTRAP mass spectrometer, and implications for the rp process

Penning trap mass measurements of neutron-deficient Cd isotopes {sup 99-109}Cd have been performed with the ISOLTRAP mass spectrometer at ISOLDE/CERN, all with relative mass uncertainties below 3{center_dot}10{sup -8}. A new mass evaluation has been performed. The mass of {sup 99}Cd has been determined for the first time, which extends the region of accurately known mass values toward the doubly magic nucleus {sup 100}Sn. The implication of the results on the reaction path of the rp process in stellar x-ray bursts is discussed. In particular, the uncertainty of the abundance and the overproduction created by the rp-process for the mass A=99 are demonstrated by reducing the uncertainty of the proton-separation energy of {sup 100}InS{sub p}({sup 100}In) by a factor of 2.5.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision test of the isobaric multiplet mass equation for the A=32, T=2 quintet

Masses of the radionuclides {sup 32,33}Si and {sup 34}P and of the stable nuclides {sup 32}S and {sup 31}P have been measured with the Low Energy Beam and Ion Trap (LEBIT) Penning trap mass spectrometer. Relative mass uncertainties as low as 3x10{sup -9} have been achieved. The measured mass value of {sup 32}Si differs from the literature value by four standard deviations. The precise mass determination of {sup 32}Si and {sup 32}S have been employed to test the validity of the quadratic form of the isobaric multiplet mass equation (IMME) for the most well known A=32, T=2 isospin quintet. The new experimental results indicate a dramatic breakdown of the model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Penning trap mass spectrometry of neutron-rich Fe and Co isotopes around N=40 with the LEBIT mass spectrometer

Penning trap mass spectrometry is presented as a complementary tool to nuclear spectroscopy experiments for the study of nuclear structure in the vicinity of N=40, Z=28. High-precision mass measurements of the {sup 63-66}Fe and {sup 64-67}Co isotopes have been carried out with the Low Energy Beam and Ion Trap (LEBIT) Penning trap mass spectrometer. The newly obtained mass values for {sup 66}Fe and {sup 67}Co are presented, together with the previously reported LEBIT mass measurements in this region. In the case of {sup 65}Fe the existence of a new isomer is reported, and an isomer recently discovered by decay spectroscopy in {sup 67}Co is confirmed. Relative mass uncertainties as low as 4x10{sup -8} are obtained. All mass values are found to be in good agreement with previous experimental results with the exception of {sup 64}Co, where a 5sigma deviation is observed. Using these data the two neutron separation energies S{sub 2n} are calculated. However, the large error bars in the mass values of the neighbor Fe and Co isotopes with N>40 complicate the validation of a weak subshell closure at N=40 for the Co isotopes or the possible reduction in the neutron shell gap in the case of the Fe isotopes, in accordance with the theoretical predictions of an onset of deformation in the region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Unified approach to electron and neutrino elastic scattering off nuclei with an application to the study of the axial structure

In this paper, we show a relationship between elastic electron scattering observables and the elastic neutrino cross section that provides a straightforward determination of the latter from experimental data of the former and relates their uncertainties. An illustration of this procedure is presented using a Hartree-Fock mean field for the nuclear structure of a set of even-even nuclear targets, using the spectra of the neutrinos produced in pion decay at rest. We also analyze the prospects for measuring the incoherent axial contribution to the neutrino elastic scattering in odd targets.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Signals of unparticles in low energy parity violation and the NuTeV experiment

We have studied the possible signals of unparticle in atomic parity violation (APV) along an isotope chain and in the NuTeV experiment. The effects of unparticle physics could be observed in APV, if the uncertainty in relative neutron/proton radius shift {delta}({delta}(R{sub N}/R{sub P})) is less than a few times 10{sup -4} by measuring the parity violating electron scattering. The constraints imposed by the NuTeV experiment on unparticle physics are discussed in detail. If the NuTeV results are confirmed by future experiments, we suggest that unparticle could account for a part of the NuTeV anomaly. There exist certain regions for the unparticle parameters ({lambda}{sub U}, d{sub U}, c{sub VU}, and c{sub AU}), where the NuTeV discrepancy could be completely explained by unparticle effects and the strange quark asymmetry, even with or without the contributions from the isoscalarity violation, etc. It is remarkable that these parameter regions are consistent with the constraints from b{yields}s{gamma}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Discriminating different scenarios to account for the cosmic e{sup {+-}} excess by synchrotron and inverse Compton radiation

The excesses of the cosmic positron fraction recently measured by PAMELA and the electron spectra by ATIC, PPB-BETS, Fermi, and H.E.S.S. indicate the existence of primary electron and positron sources. The possible explanations include dark matter annihilation, decay, and astrophysical origin, like pulsars. In this work we show that these three scenarios can all explain the experimental results of the cosmic e{sup {+-}} excess. However, it may be difficult to discriminate these different scenarios by the local measurements of electrons and positrons. We propose possible discriminations among these scenarios through the synchrotron and inverse Compton radiation of the primary electrons/positrons from the region close to the Galactic center. Taking typical configurations, we find the three scenarios predict quite different spectra and skymaps of the synchrotron and inverse Compton radiation, though there are relatively large uncertainties. The most prominent differences come from the energy band 10{sup 4}{approx}10{sup 9} MHz for synchrotron emission and > or approx. 10 GeV for inverse Compton emission. It might be able to discriminate at least the annihilating dark matter scenario from the other two given the high precision synchrotron and diffuse {gamma}-ray skymaps in the future.

79 ASTRONOMY AND ASTROPHYSICS↗

Impact of nuclear mass uncertainties on the r process

Here, nuclear masses play a fundamental role in understanding how the heaviest elements in the Universe are created in the r process. We predict r -process nucleosynthesis yields using neutron capture and photodissociation rates that are based on the nuclear density functional theory. Using six Skyrme energy density functionals based on different optimization protocols, we determine for the first time systematic uncertainty bands—related to mass modeling—for r -process abundances in realistic astrophysical scenarios. We find that features of the underlying microphysics make an imprint on abundances especially in the vicinity of neutron shell closures: Abundance peaks and troughs are reflected in trends of neutron separation energy. Further advances in the nuclear theory and experiments, when linked to observations, will help in the understanding of astrophysical conditions in extreme r -process sites.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Toward virtual thin-beam 𝜈 cross-section measurements: A feasibility study of 𝜈-Ar interaction analysis with DUNE-PRISM

Neutrino-nucleus cross section measurements are critical for future neutrino oscillation analyses. However, our models to describe them require further refinement, and a deeper understanding of the underlying physics is essential for future neutrino oscillation experiments to realize their ambitious physics goals. Current neutrino cross section measurements provide clear deficiencies in neutrino interaction modeling, but almost all are reported averaged over broad neutrino fluxes, rendering their interpretation challenging. Using the concept of deep underground neutrino experiment-precision reaction independent spectrum measurement (DUNE-PRISM)—a movable near detector that samples multiple off axis positions—neutrino interaction measurements can be used to construct narrow virtual fluxes (less than 100 MeV wide). These fluxes can be used to extract charged-current neutrino-nucleus cross sections as functions of outgoing lepton kinematics within specific neutrino energy ranges. Based on a dedicated simulation with realistic event statistics and flux-related systematic uncertainties, but assuming an almost-perfect detector, we run a feasibility study demonstrating how DUNE-PRISM data can be used to measure muon neutrino charged-current integrated and differential cross sections over narrow fluxes. We find that this approach enables a largely model-independent reconstruction of powerful observables, including energy transfer, typically accessible only in electron scattering measurements, but that large exposures may be required for differential cross section measurements with few-percentage statistical uncertainties.

Neutrino interactions↗

Evaluation of a lithium formate EPR dosimetry system for dose measurements around {sup 192}Ir brachytherapy sources

A dosimetry system using lithium formate monohydrate (HCO{sub 2}Li{center_dot}H{sub 2}O) as detector material and electron paramagnetic resonance (EPR) spectroscopy for readout has been used to measure absorbed dose distributions around clinical {sup 192}Ir sources. Cylindrical tablets with diameter of 4.5 mm, height of 4.8 mm, and density of 1.26 g/cm{sup 3} were manufactured. Homogeneity test and calibration of the dosimeters were performed in a 6 MV photon beam. {sup 192}Ir irradiations were performed in a PMMA phantom using two different source models, the GammaMed Plus HDR and the microSelectron PDR-v1 model. Measured absorbed doses to water in the PMMA phantom were converted to the corresponding absorbed doses to water in water phantoms of dimensions used by the treatment planning systems (TPSs) using correction factors explicitly derived for this experiment. Experimentally determined absorbed doses agreed with the absorbed doses to water calculated by the TPS to within {+-}2.9%. Relative standard uncertainties in the experimentally determined absorbed doses were estimated to be within the range of 1.7%-1.3% depending on the radial distance from the source, the type of source (HDR or PDR), and the particular absorbed doses used. This work shows that a lithium formate dosimetry system is well suited for measurements of absorbed dose to water around clinical HDR and PDR {sup 192}Ir sources. Being less energy dependent than the commonly used thermoluminescent lithium fluoride (LiF) dosimeters, lithium formate monohydrate dosimeters are well suited to measure absorbed doses in situations where the energy dependence cannot easily be accounted for such as in multiple-source irradiations to verify treatment plans. Their wide dynamic range and linear dose response over the dose interval of 0.2-1000 Gy make them suitable for measurements on sources of the strengths used in clinical applications. The dosimeter size needs, however, to be reduced for application to single-source dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

A novel synthetic single crystal diamond device for in vivo dosimetry

Purpose: Aim of the present work is to evaluate the synthetic single crystal diamond Schottky photodiode developed at the laboratories of “Tor Vergata” University in Rome in a new dosimeter configuration specifically designed for offline wireless in vivo dosimetry (IVD) applications. Methods: The new diamond based dosimeter, single crystal diamond detector (SCDD-iv), consists of a small unwired detector and a small external reading unit that can be connected to commercial electrometers for getting the detector readout after irradiation. Two nominally identical SCDD-iv dosimeter prototypes were fabricated and tested. A basic dosimetric characterization of detector performances relevant for IVD application was performed under irradiation with {sup 60}Co and 6 MV photon beams. Preirradiation procedure, response stability, short and long term reproducibility, leakage charge, fading effect, linearity with dose, dose rate dependence, temperature dependence, and angular response were investigated. Results: The SCDD-iv is simple, with no cables linked to the patient and the readout is immediate. The range of response with dose has been tested from 1 up to 12 Gy; the reading is independent of the accumulated dose and dose rate independent in the range between about 0.5 and 5 Gy/min; its temperature dependence is within 0.5% between 25 and 38 °C, and its directional dependence is within 2% from 0° to 90°. The combined relative standard uncertainty of absorbed dose to water measurements is estimated lower than the tolerance and action level of 5%. Conclusions: The reported results indicate the proposed novel offline dosimeter based on a synthetic single crystal diamond Schottky photodiode as a promising candidate for in vivo dosimetry applications with photon beams.

07 ISOTOPE AND RADIATION SOURCES↗

WE-DE-201-02: A Statistical Analysis Tool for Plan Quality Verification in HDR Brachytherapy Forward Planning for Cervix Cancer

Purpose: High Dose Rate (HDR) brachytherapy forward planning is principally an iterative process; hence, plan quality is affected by planners’ experiences and limited planning time. Thus, this may lead to sporadic errors and inconsistencies in planning. A statistical tool based on previous approved clinical treatment plans would help to maintain the consistency of planning quality and improve the efficiency of second checking. Methods: An independent dose calculation tool was developed from commercial software. Thirty-three previously approved cervical HDR plans with the same prescription dose (550cGy), applicator type, and treatment protocol were examined, and ICRU defined reference point doses (bladder, vaginal mucosa, rectum, and points A/B) along with dwell times were collected. Dose calculation tool then calculated appropriate range with a 95% confidence interval for each parameter obtained, which would be used as the benchmark for evaluation of those parameters in future HDR treatment plans. Model quality was verified using five randomly selected approved plans from the same dataset. Results: Dose variations appears to be larger at the reference point of bladder and mucosa as compared with rectum. Most reference point doses from verification plans fell between the predicted range, except the doses of two points of rectum and two points of reference position A (owing to rectal anatomical variations & clinical adjustment in prescription points, respectively). Similar results were obtained for tandem and ring dwell times despite relatively larger uncertainties. Conclusion: This statistical tool provides an insight into clinically acceptable range of cervical HDR plans, which could be useful in plan checking and identifying potential planning errors, thus improving the consistency of plan quality.

60 APPLIED LIFE SCIENCES↗