Displacement-Current Phase Tomography for Water-Dominated Two-Phase Flow Velocimetry
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Visual inspection makes easier to ensure the integrity and safety of spent nuclear fuel (SNF) than any classical techniques. Various classical techniques have been applied but there are no reliable methods to qualitatively and quantitatively verify spent fuel in dry storage. Thus, the present authors have developed the prototype safeguards apparatus for dry storage employing the array of He-4 gas scintillation detectors (S670E, Arktis Radiation Detectors Ltd., Switzerland), newly designed to simultaneously measure thermal and fast neutrons without any moderators. The S670E detector has a cylindrical shape with a diameter of 52 mm and active length of 600 mm (total length: 875 mm). The detector is filled by He-4 gas with an approximate pressure of 180 bar for fast neutron detection, and its inner wall is coated by Li-6 for thermal neutron detection. The scintillation lights generated via Li-6 nuclear reaction and elastic scattering are collected by 24 SiPMs linearly paired at the center of the detector. The detector delivers a TTL (Transistor-Transistor Logic) output for pulse readout and UART (Universal Asynchronous Receiver Transmitter) for device control. In order to assess feasibility of the apparatus, an experimental system has been designed, built, and optimized via computational studies. Cf-252 neutron sources and linearly arrayed detectors, working as a single detector, were occupied for this study due to the difficulties in working with SNF. The laboratory scale cask (diameter: 0.67 m, height: 1.5 m), minimized by a factor of 10 compared to the actual thickness of a commercial TN-32 cask, was also manufactured. The detector array was designed to rotate the lab-scale cask and obtain 36 image profiles at every 10 degrees. All profiles were aligned in single frame image called a sinogram, and the cross-sectional image was then fabricated by the inverse radon transform algorithm. These experiments have been repeated with different configurations and numbers of sources. Some gamma-ray sources were also measured with neutron sources in order to distinguish between neutron and gamma-ray pulses. Basically, a He-4 detector is designed to run on Linux OS so it is difficult to directly apply to Windows-based equipment widely used in S. Korea. Therefore, a new data acquisition board working on Windows OS was designed and built. The board mainly consists of FPGA (Field Programmable Gate Array) and SoC (System on Chip) for TTL pulse readout, sorting measured data, and transferring data to a user interface. In conclusion, the tomographic system at lab-scale has shown considerable potential to detect a partial or gross defect of encapsulated assemblies in dry storage. Next steps of this study will be to 1) repeatedly carry out experiments to demonstrate scientific reliability and validity, and 2) numerically integrate signals with weight factors to enhance the image quality since the suggested system based on passive interrogation method requires longer measurement time. Finally, the system will apply to a commercial dry storage phased out soon in S. Korea. (authors)
The Nuclear Materials Identification System (NMIS) detects and characterizes fissile and nonfissile materials using time correlations between a time-tagged source and one or more detectors. The first fieldable configuration of dedicated hardware and software was developed in the 1990s. In its original configuration, the measurement system consisted of a time-tagged source and two to four detectors. Measurements with this configuration were easily simulated using a single Monte Carlo run. The present measurement configuration is far more complex than the original. The source is now divided into multiple neutron cones; significantly more detectors are included; and the source, detectors, and object being interrogated can all be moved during the measurement to capture different views of the object. In addition to the hardware changes, the software can now reconstruct high-resolution tomographs of the 14 MeV neutron attenuation coefficients and fission sites inside the object. This work shows how a complex measurement of an object that consists of both fissile and nonfissile parts can be simulated by using multiple input decks and combining the resulting output into the desired format. The results of this simulation were then reconstructed using the imaging and fission-mapping software used with measurements. These reconstructions are consistent with the original model, thus validating the simulation method.
X-ray computed tomography (CT) refers to the cross-sectional imaging of an object measuring the transmitted radiation at different directions. In this work, we describe the development of a low cost micro-CT X-ray scanner that is being developed for nondestructive testing. This tomograph operates using a microfocus X-ray source and contains a silicon photodiode as detectors. The performance of the system, by its spatial resolution, has been estimated through its Modulation Transfer Function-MTF and the obtained value at 10% of MTF is 661 {mu}m. It was built as a general purpose nondestructive testing device.
We constructed a laboratory-size three-dimensional water-window x-ray microscope that combines wide-field transmission x-ray microscopy with tomographic reconstruction techniques. It consists of an electron-impact x-ray source emitting oxygen Kα x-rays, Wolter type I grazing incidence mirror optics, and a back-illuminated CCD for x-ray imaging. A spatial resolution limit better than 1.0 line pairs per micrometer was obtained for two-dimensional transmission images, and 1-μm-scale three-dimensional fine structures were resolved.
We present spatially resolved radio-frequency spectroscopy of a trapped Fermi gas with resonant interactions and observe a spectral gap at low temperatures. The spatial distribution of the spectral response of the trapped gas is obtained using in situ phase-contrast imaging and 3D image reconstruction. At the lowest temperature, the homogeneous rf spectrum shows an asymmetric excitation line shape with a peak at 0.48(4){epsilon}{sub F} with respect to the free atomic line, where {epsilon}{sub F} is the local Fermi energy.
ABSTRACT Upcoming deep imaging surveys such as the Vera C. Rubin Observatory Legacy Survey of Space and Time will be confronted with challenges that come with increased depth. One of the leading systematic errors in deep surveys is the blending of objects due to higher surface density in the more crowded images; a considerable fraction of the galaxies which we hope to use for cosmology analyses will overlap each other on the observed sky. In order to investigate these challenges, we emulate blending in a mock catalogue consisting of galaxies at a depth equivalent to 1.3 yr of the full 10-yr Rubin Observatory that includes effects due to weak lensing, ground-based seeing, and the uncertainties due to extraction of catalogues from imaging data. The emulated catalogue indicates that approximately 12 per cent of the observed galaxies are ‘unrecognized’ blends that contain two or more objects but are detected as one. Using the positions and shears of half a billion distant galaxies, we compute shear–shear correlation functions after selecting tomographic samples in terms of both spectroscopic and photometric redshift bins. We examine the sensitivity of the cosmological parameter estimation to unrecognized blending employing both jackknife and analytical Gaussian covariance estimators. An ∼0.025 decrease in the derived structure growth parameter S8 = σ8(Ωm/0.3)0.5 is seen due to unrecognized blending in both tomographies with a slight additional bias for the photo-z-based tomography. This bias is greater than the 2σ statistical error in measuring S8.
PurposeTo assess the relative efficacy of empiric gastroduodenal artery (GDA) embolization in reducing recurrent hemorrhage compared to image-guided targeted embolization.MethodsData were retrospectively collected for consecutive patients who had catheter angiography for major upper gastrointestinal hemorrhage from May 2008 to November 2010 (n = 40). The total number of cases were divided into two main groups according to angiographic findings: those that demonstrated a site of hemorrhage on catheter angiography (group 1, n = 13), and those where the site of hemorrhage was not identified on catheter angiography (group 2, n = 27). Group 2 was then further divided into patients who received empiric embolization (group 2a, n = 20) and those who had no embolization performed after angiography (group 2b, n = 7).ResultsThe technical and clinical success rates for embolization in groups 1 and 2a were, respectively, 100 vs. 95 %, and 85 vs. 80 %. There was no statistical significance in the recurrent hemorrhage rate, reintervention rate, or 30 day mortality between targeted and empiric embolization groups. There were no complications attributed to embolization within this study cohort.ConclusionCases of duodenal-related major upper gastrointestinal hemorrhage where no embolization is performed have poor outcome. Empiric embolization of the GDA in patients with major upper gastrointestinal hemorrhage refractory to endoscopic treatment appears to be a safe and effective treatment, with low reintervention rates and good clinical outcome comparable to patients where the site of hemorrhage is localized and embolized with computed tomographic angiography or catheter angiography and embolized.
This work describes the instrumentation and software for microbeam scattering and structural mapping at the Life Science X-ray Scattering (LiX) beamline at NSLS-II. Using a two-stage focusing scheme, an adjustable beam size between a few micrometres and a fraction of a millimetre is produced at the sample position. Scattering data at small and wide angles are collected simultaneously on multiple Pilatus detectors. A recent addition of an in-vacuum Pilatus 900k detector, with the detector modules arranged in a C-shaped configuration, has improved the azimuthal angle coverage in the wide-angle data. As an option, fluorescence data can be collected simultaneously. Fly scans have been implemented to minimize the time interval between scattering patterns and to avoid unnecessary radiation damage to the sample. For weakly scattering samples, an in-vacuum sample environment has been developed here to minimize background scattering. Data processing for these measurements is highly sample-specific. To establish a generalized data process workflow, first the data are reduced to reciprocal coordinates at the time of data collection. The users can then quantify features of their choosing from these intermediate data and construct structural maps. As examples, results from in-vacuum mapping of onion epidermal cell walls and 2D tomographic sectioning of an intact poplar stem are presented.
Complex dynamic tomographic experiments at brilliant X-ray light sources require real-time feedback on the sample changes with respect to environmental conditions, selecting representative regions of interest for high-resolution scanning, and on-demand data saving mechanisms for storing only relevant projections acquired by fast area detectors and reducing data volumes. Here the implementation details of a 3D real-time imaging monitoring instrument, with zooming to a volume of interest with easy-to-use visualization via ImageJ , a tool familiar to most beamline users, is presented. The instrument relies on optimized data flow between the detector and processing machines and is implemented on commodity computers. The instrument has been developed at beamline 2-BM of the Advanced Photon Source, where the automatic lens changing mechanism for zooming is implemented with an Optique Peter microscope. Performance tests demonstrate the ability to process more than 3 GB of projection data per second and generate real-time 3D zooming with different magnification. These new capabilities are essential for new APS Upgrade instruments such as the projection microscope under development at beamline 32-ID. The efficacy of the proposed instrument was demonstrated during an in situ tomographic experiment on ice and gas hydrate formation in porous samples.
Dual-energy computed tomography and the Alvarez and Macovski [Phys. Med. Biol. 21, 733 (1976)] transmitted intensity (AMTI) model were used in this study to estimate the maps of density (ρ) and atomic number (Z) of mineralogical samples. In this method, the attenuation coefficients are represented [Alvarez and Macovski, Phys. Med. Biol. 21, 733 (1976)] in the form of the two most important interactions of X-rays with atoms that is, photoelectric absorption (PE) and Compton scattering (CS). This enables material discrimination as PE and CS are, respectively, dependent on the atomic number (Z) and density (ρ) of materials [Alvarez and Macovski, Phys. Med. Biol. 21, 733 (1976)]. Dual-energy imaging is able to identify sample materials even if the materials have similar attenuation coefficients at single-energy spectrum. We use the full model rather than applying one of several applied simplified forms [Alvarez and Macovski, Phys. Med. Biol. 21, 733 (1976); Siddiqui et al., SPE Annual Technical Conference and Exhibition (Society of Petroleum Engineers, 2004); Derzhi, U.S. patent application 13/527,660 (2012); Heismann et al., J. Appl. Phys. 94, 2073–2079 (2003); Park and Kim, J. Korean Phys. Soc. 59, 2709 (2011); Abudurexiti et al., Radiol. Phys. Technol. 3, 127–135 (2010); and Kaewkhao et al., J. Quant. Spectrosc. Radiat. Transfer 109, 1260–1265 (2008)]. This paper describes the tomographic reconstruction of ρ and Z maps of mineralogical samples using the AMTI model. The full model requires precise knowledge of the X-ray energy spectra and calibration of PE and CS constants and exponents of atomic number and energy that were estimated based on fits to simulations and calibration measurements. The estimated ρ and Z images of the samples used in this paper yield average relative errors of 2.62% and 1.19% and maximum relative errors of 2.64% and 7.85%, respectively. Furthermore, we demonstrate that the method accounts for the beam hardening effect in density (ρ) and atomic number (Z) reconstructions to a significant extent.
I show that in tomographic experiments, the measurement of a small set of observables suffices to confirm or incrementally amend prior expectations with a high degree of confidence. To this end, I adapt the evidence procedure, an estimation technique used in classical image reconstruction, for use in quantum-state tomography.
The Helmholtz-Zentrum Geesthacht operates the P05 Imaging Beamline at the DESY storage ring PETRA III. This beamline is dedicated to micro- and nanotomography with two endstations. This paper will present the nanotomography endstation layout and first results obtained from commissioning and test experiments. First tests have been performed with CRLs as X-ray objectives and newly developed rolled X-ray prism lenses as condenser optics. This setup allows a resolution of 100 nm half period with an effective detector pixel size of 15nm. A first tomograph of a photonic glass sample was measured in early 2014.
The fundamental processes of the inner corona of the Sun at 1.1 to 3 solar radii can occasionally be investigated in detail by ground-based solar eclipse observations at quasi-yearly intervals. The combination of portable ground-based telescopes and the distant occulting edge provided by the lunar limb allows imaging of coronal structure and ion excitation emission lines at the highest available spatial and spectral resolution. These observations are limited to the visible eastern and western coronal regions and cannot view the intervening region over the central disk in the hemisphere towards Earth. A comparable configuration for continuous coronal observations from a spacecraft, e.g. with an external occulter disk on a 100-meter boom, is conceivable and could generate 3-D data models of the corona via tomographic reconstruction from time series measurements but may not now be technically or economically feasible. The faster and cheaper approach would be to make high cadence eclipse observations from one or more small satellites in lunar orbit. The Solar Occultation Explorer (SOX) is suggested as an explorer-class NASA mission that would conduct eclipse observations at daily to hourly cadence depending on the orbit. This smallsat would carry two principal instrument suites: (1 ) spectroscopic imaging telescope with sub-nm resolution for selected coronal emission lines diagnostic of coronal plasma charge state, denSity, and temperature, and (2) in-situ field & particle instrument suite for measurements of the solar wind and local lunar environments. The most comparable flight heritage instrument, the LASCO C1 spectrometer on the Solar and Heliospheric Observatory (SOHO) mission, did achieve high visible-band spectral resolution with a Fabry-Perot interferometer but was limited in brightness sensitivity by usage of an internal occulter system and has not been operational since June 1998 The SOX mission concept is undergoing initial study by the Lunar Solar Origins Exploration (LunaSOX) project of the NASA Lunar Advanced Science and Exploration Research (LASER) program. This mission would offer high complementarity with the planned Solar Probe Plus spacecraft, designed to investigate.
For reconstructing large tomographic datasets fast, filtered backprojection-type or Fourier-based algorithms are still the method of choice, as they have been for decades. These robust and computationally efficient algorithms have been integrated in a broad range of software packages. The continuous mathematical formulas used for image reconstruction in such algorithms are unambiguous. However, variations in discretization and interpolation result in quantitative differences between reconstructed images, and corresponding segmentations, obtained from different software. This hinders reproducibility of experimental results, making it difficult to ensure that results and conclusions from experiments can be reproduced at different facilities or using different software. In this paper, a way to reduce such differences by optimizing the filter used in analytical algorithms is proposed. These filters can be computed using a wrapper routine around a black-box implementation of a reconstruction algorithm, and lead to quantitatively similar reconstructions. Use cases for this approach are demonstrated by computing implementation-adapted filters for several open-source implementations and applying them to simulated phantoms and real-world data acquired at the synchrotron. Our contribution to a reproducible reconstruction step forms a building block towards a fully reproducible synchrotron tomography data processing pipeline.
While microelectronic devices are frequently characterized with surface-sensitive techniques having nanometer resolution, interconnections used in 3D integration require 3D imaging with high penetration depth and deep sub-micrometer spatial resolution. X-ray tomography is well adapted to this situation. In this context, the purpose of this study is to assess a versatile and turn-key tomographic system allowing for 3D x-ray nanotomography of copper pillars. The tomography tool uses the thin electron beam of a scanning electron microscope (SEM) to provoke x-ray emission from specific metallic targets. Then, radiographs are recorded while the sample rotates in a conventional cone beam tomography scheme that ends up with 3D reconstructions of the pillar. Starting from copper pillars data, collected at the European Synchrotron Radiation Facility, we build a 3D numerical model of a copper pillar, paying particular attention to intermetallics. This model is then used to simulate physical radiographs of the pillar using the geometry of the SEM-hosted x-ray tomography system. Eventually, data are reconstructed and it is shown that the system makes it possible the quantification of 3D intermetallics volume in copper pillars. The paper also includes a prospective discussion about resolution issues.
The evolution of cartilage degeneration is still not fully understood, partly due to its thinness, low radio-opacity and therefore lack of adequately resolving imaging techniques. X-ray phase-contrast imaging (X-PCI) offers increased sensitivity with respect to standard radiography and CT allowing an enhanced visibility of adjoining, low density structures with an almost histological image resolution. This study examined the feasibility of X-PCI for high-resolution (sub-) micrometer analysis of different stages in tissue degeneration of human cartilage samples and compare it to histology and transmission electron microscopy. Ten 10%-formalin preserved healthy and moderately degenerated osteochondral samples, post-mortem extracted from human knee joints, were examined using four different X-PCI tomographic set-ups using synchrotron radiation the European Synchrotron Radiation Facility (France) and the Swiss Light Source (Switzerland). Volumetric datasets were acquired with voxel sizes between 0.7 × 0.7 × 0.7 and 0.1 × 0.1 × 0.1 µm 3 . Data were reconstructed by a filtered back-projection algorithm, post-processed by ImageJ, the WEKA machine learning pixel classification tool and VGStudio max. For correlation, osteochondral samples were processed for histology and transmission electron microscopy. X-PCI provides a three-dimensional visualization of healthy and moderately degenerated cartilage samples down to a (sub-)cellular level with good correlation to histologic and transmission electron microscopy images. X-PCI is able to resolve the three layers and the architectural organization of cartilage including changes in chondrocyte cell morphology, chondrocyte subgroup distribution and (re-)organization as well as its subtle matrix structures. X-PCI captures comprehensive cartilage tissue transformation in its environment and might serve as a tissue-preserving, staining-free and volumetric virtual histology tool for examining and chronicling cartilage behavior in basic research/laboratory experiments of cartilage disease evolution.
This paper details effort by researchers at NASA Langley Research Center to prepare for an upcoming high-speed tomographic background-oriented schlieren test entry in the 31-Inch Mach 10 wind tunnel. In order to troubleshoot potential problems that will arise when setting up the experiment in the actual test facility, a full-scale mock-up of the 31-Inch Mach 10 wind tunnel test section was constructed in the laboratory to provide equivalent characteristic optical access and mounting options. A 3D-printed model that replicates the scale of the forebody of a supersonic retropropulsion (SRP) model that will be used in the final test entry has been fabricated with a central nozzle that can be connected to a high-pressure gas supply to approximate the nozzle flow that will occur. Six high-speed imaging systems consisting of a high-speed camera with a fiber illuminator module have been assembled and mounted on the test section mock-up to provide six unique perspective views of the nozzle flow from the model. Tests with one of the imaging systems using a pulsed laser light source showed that sufficient signal intensity and illumination uniformity was achieved, as demonstrated by the 2D BOS data obtained with the system. Additional work to show that retroreflective material would survive inside of the test section of the 31-Inch Mach 10 tunnel was also performed. Finally, a remotely-controlled tomographic BOS calibration system is discussed.