Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “timing detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Time calibration and synchronization of the scintillation light detection system in ICARUS-T600

The ICARUS-T600 Liquid Argon (LAr) Time Projection Chamber (TPC) is presently used as a far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible LSND-like sterile neutrino signal at $\Delta m^2 \approx 1 eV^2$ with the Booster Neutrino Beam (BNB). A light detection system, based on 360 large area Photo-Multiplier Tubes (PMTs), has been realized for ICARUS-T600 to detect VUV photons produced after the passage of ionizing particles in LAr. This system is fundamental for the TPC operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the detector is exposed to a huge flux of cosmic rays due to its shallow depths operations, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of neutrino interactions within the BNB spill gate. The correct time reconstruction of events requires the precise knowledge of the delay of each PMT channel and a good synchronization of recording electronics, this last based on fast sampling digitizers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impedance matched superconducting nanowire photodetector for single- and multi-photon detection

Conventional readout of a superconducting nanowire single-photon detector (SNSPD) sets an upper bound on the output voltage to be the product of the bias current and the load impedance, IB×Zload, where Zload is limited to 50Ω in standard RF electronics. This limit is broken/exceeded by interfacing the 50Ω load and the SNSPD using an integrated superconducting transmission line taper. The taper is a transformer that effectively loads the SNSPD with high impedance without latching. The taper increases the amplitude of the detector output while preserving the fast rising edge. Using a taper with a starting width of 500 nm, a 3.6× higher pulse amplitude, 3.7× faster slew rate, and 25.1 ps smaller timing jitter was observed. The taper also makes the detector's output voltage sensitive to the number of photon-induced hotspots and enables photon number resolution.

Zhu, Di↗

A neural network for beam background decomposition in Belle II at SuperKEKB

Here, we describe a neural network for predicting the background hit rate in the Belle II detector produced by the SuperKEKB electron-positron collider. The neural network, BGNet, learns to predict the individual contributions of different physical background sources, such as beam-gas scattering or continuous top-up injections into the collider, to Belle II sub-detector rates. The samples for learning are archived 1 Hz time series of diagnostic variables from the SuperKEKB collider subsystems and measured hit rates of Belle II used as regression targets. We test the learned model by predicting detector hit rates on archived data from different run periods not used during training. We show that a feature attribution method can help interpret the source of changes in the background level over time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A sub-5 ps jitter time-to-digital converter ASIC with back-gate delay tuning in 22 nm CMOS

We present the design of a Time-to-Digital Converter (TDC) ASIC together with performance characterization results at cryogenic temperature (6-8 K), and at room temperature using emulated Low-Gain Avalanche Detector (LGAD) signals. The TDC design uses a two-step architecture with a ring-oscillator based counter and a Vernier delay line fine TDC. The TDC is implemented in an FD-SOI process, and back-gate tuning is used not only to correct threshold variation due to cryogenic operation, but also as a novel way to tune TDC delay elements with very little overhead. Using this technique, we demonstrate a design with very low power (0.5 mW) and area (0.003 mm 2 ). We present test results using the Fermilab Constant Fraction Discriminator (FCFD) ASIC to produce discriminated signals from an internal charge injection mechanism that mimics the waveform and signal amplitude of minimum ionizing particles impinging on LGAD sensors. We characterize the time precision of the full system and verify that the TDC ASIC contributes a negligible amount to the total system time precision, fully consistent with the expected jitter contribution of less than 5 ps. In conclusion, the results presented here demonstrate the utility of our TDC for applications in physics and quantum communications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced high-performance large diameter Cs 2 HfCl 6 (CHC) and mixed halides scintillator

This paper reports on successful growth and performance evaluation of two large diameter Cs 2 HfCl 6 (CHC) and Cs 2 HfCl 4 Br 2 (CHCB), both recently developed scintillator crystals. The discovery of Cs 2 HfCl 6 (CHC) as a scintillator has lately generated much interest in this material and its family, which belongs to the K 2 PtCl 6 cubic crystal structure. CHC is an intrinsic scintillator that is non-hygroscopic (slightly deliquescent, i.e., slightly moisture sensitive but does not deteriorate much when left in air), has no self-radioactivity, provides excellent energy resolution, and has excellent non-proportionality. CHC has a moderate density of 3.9 g/cm 3 and an effective atomic number of 58. Reported in this paper are transparent crack-free single crystal CHC and CHCB boules of one inch in diameter, both grown using the vertical Bridgman method. Samples retrieved from the boules, sized 23 mm × 30 mm and 23 mm × 26 mm, respectively, are characterized for their optical and scintillation properties. Energy resolutions of 3.5% and 3.7% (FWHM) at 662 keV, respectively, are reported. Light yields of 23,000 ph/MeV and 20,000 ph/MeV have been calculated for the large diameter CHC and CHCB crystals, respectively. Results comparable to previously reported results for smaller crystals have been obtained. Studies on decay time, non-proportionality, as well as detector characterization are also reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of a boron-loaded deuterated liquid scintillator for fast and thermal neutron detection

The preparation and characterization of novel boron-loaded deuterated liquid scintillators (BLDLS) are presented for the first time to investigate the performance of a detector sensitive to both fast and thermal neutrons intended for future neutron spectroscopy measurements. Three deuterated toluene-based scintillation cocktails were produced, one without boron, one loaded with ortho-carborane (natural boron isotopic abundance), and one with 96 wt% 10B enriched ortho-carborane. General optical and material properties were analyzed to include the composition, density, index of refraction, photoluminescence emission spectra, and absorbance spectra in addition to the relative light yield, resolution, relative efficiency, and pulse-shape-discrimination performance for all three scintillators and a hydrogen-based EJ-309 scintillator to evaluate the effects of boron loading in comparison with a common commercially-available scintillator and feasibility for future neutron spectroscopy measurements. Finally, the detection of shielded neutron sources was explored to capitalize on the 10B thermal neutron capture reaction. The results showed loading the scintillators with boron deteriorated the PSD performance slightly compared to the unloaded deuterated scintillator and resulted in a relative light yield loss of 26% and 41% for the 10B enriched and natural boron BLDLS, respectively. Lastly, the BLDLS have a higher relative detection efficiency than the unloaded deuterated scintillator for shielded neutron sources, based on total count rate, a desirable characteristic for missions related to finding and characterizing illicitly-trafficked special nuclear material.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Studies of LAPPD and HRPPD photodetectors for Cherenkov imaging applications

HRPPDs are the baseline single-photon sensors for a classic proximity-focusing RICH (pfRICH) counter, one of the Cherenkov radiation-based PID subsystems of the ePIC detector at the EIC. We report SPE time resolution of 87 ps rms for an LAPPD unit detecting Cherenkov photons in a quartz lens at a CERN PS test beam (2022). We also present the degradation and partial recovery of gain and relative efficiency of an LAPPD unit as a function of the B-field strength (up to 1.5 T) and angular orientation, measured with vertical dipole magnets at CERN (2023–2024). Finally, we report preliminary results of an accelerated ageing study performed on an HRPPD unit in Trieste laboratory (2025).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A 3-Year Sample of Almost 1,600 Elves Recorded Above South America by the Pierre Auger Cosmic-Ray Observatory

Elves are a class of transient luminous events, with a radial extent typically greater than 250 km, that occur in the lower ionosphere above strong electrical storms. We report the observation of 1,598 elves, from 2014 to 2016, recorded with unprecedented time resolution (100 ns) using the fluorescence detector (FD) of the Pierre Auger Cosmic-Ray Observatory. The Auger Observatory is located in the Mendoza province of Argentina with a viewing footprint for elve observations of 3∙10sup>6 km ₂, reaching areas above the Pacific and Atlantic Oceans, as well as the Córdoba region, which is known for severe convective thunderstorms. Primarily designed for ultrahigh energy cosmic-ray observations, the Auger FD turns out to be very sensitive to the ultraviolet emission in elves. The detector features modified Schmidt optics with large apertures resulting in a field of view that spans the horizon, and year-round operation on dark nights with low moonlight background, when the local weather is favorable. The measured light profiles of 18% of the elve events have more than one peak, compatible with intracloud activity. Within the 3-year sample, 72% of the elves correlate with the far-field radiation measurements of the World Wide Lightning Location Network. The Auger Observatory plans to continue operations until at least 2025, including elve observations and analysis. To the best of our knowledge, this observatory is the only facility on Earth that measures elves with year-round operation and full horizon coverage.

79 ASTRONOMY AND ASTROPHYSICS↗

Machine learning inversion of interatomic force constants from single-crystal inelastic neutron scattering

Atomic vibrations govern many macroscopic properties of materials, but experiments to comprehensively probe them remain challenging. Inelastic neutron scattering (INS) is a powerful technique to map phonon dispersions in crystals, especially when leveraging modern time-of-flight (ToF) spectrometers with large detectors. However, efficiently and robustly extracting interatomic force constants (FCs) parameterizing phonon dynamics from experimental spectra remains a bottleneck due to the complexity and high dimensionality of ToF INS datasets. Here, we present a machine learning approach for the direct inversion of FCs from single-crystal INS measurements. The framework leverages synthetic training data generated using universal machine-learned force fields and an efficient physics-based forward model. We benchmark two neural architectures–one emphasizing structured latent representation learning and the other direct, supervised spectral regression–across simulated datasets for two materials under idealized and noisy conditions. The latent-representation model is subsequently applied to experimental single-crystal INS data on germanium. The model is shown to reproduce FCs derived from both first-principles simulations and from iterative optimization, and furthermore achieves reliable inference even from sparse, single-orientation measurements representing short data acquisitions. Analysis of the learned latent space reveals semantically continuous and physically interpretable encodings that support strong cross-domain generalization. By bridging theoretical and experimental domains, we establish a path toward rapid inversion of experimental spectra and data-driven interpretation of temperature-dependent lattice dynamics.

42 ENGINEERING↗

The inertial confinement fusion experimental platform and diagnostics for studies of nuclear reactions relevant to nuclear astrophysics

High energy density plasmas generated in laser-driven inertial confinement fusion implosions provide unparalleled laboratory conditions for studying stellar-relevant nuclear reactions: plasma environment; hot and dense; uniquely high achievable neutron flux. These experiments have the potential to address long-standing questions about plasma effects on nuclear reactions hitherto experimentally inaccessible, including nuclear rates with thermally distributed reactants, plasma screening, and reactions involving nuclei in excited states. The National Ignition Facility (NIF) and OMEGA lasers are two primary facilities for executing experiments of this type. Existing and future nuclear diagnostics, along with supporting diagnostics to characterize the platform, enable exploitation of these plasmas for such nuclear astrophysics-relevant experiments. Here, this review describes the nuclear diagnostic capabilities currently available for these types of experiments at the NIF and OMEGA, including neutron time-of-flight spectrometers, charged-particle detectors, gamma detectors and radiochemistry diagnostics, and briefly summarizes other available diagnostic capabilities used for platform characterization. Enabling tools not yet available are also identified, including a rapid radioactive sample retrieval system, a low-energy neutron spectrometer and a high-efficiency gamma spectrometer.

National Ignition Facility↗

Use of Neutrino Scattering Events with Low Hadronic Recoil to Inform Neutrino Flux and Detector Energy Scale

Charged-current neutrino interactions with low hadronic recoil ("low-nu") have a cross-section that is approximately constant versus neutrino energy. These interactions have been used to measure the shape of neutrino fluxes as a function of neutrino energy at accelerator-based neutrino experiments such as CCFR, NuTeV, MINOS and MINERvA. In this paper, we demonstrate that low-nu events can be used to measure parameters of neutrino flux and detector models and that utilization of event distributions over the upstream detector face can discriminate among parameters that affect the neutrino flux model. From fitting a large sample of low-nu events obtained by exposing MINERvA to the NuMI medium-energy beam, we find that the best-fit flux parameters are within their a priori uncertainties, but the energy scale of muons reconstructed in the MINOS detector is shifted by 3.6% (or 1.8 times the a priori uncertainty on that parameter). These fit results are now used in all MINERvA cross-section measurements, and this technique can be applied by other experiments operating at MINERvA energies, such as DUNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Molecular-Resolution Electron Imaging of Defects and Dynamics at the Ice-Water Interface

Water crystallization into hexagonal ice (type I h ) is one of the most critical processes relevant to the Earth’s environment and human activities. However, despite recent breakthroughs in imaging non-equilibrium condensed ice structures, the ice-water interface has never been imaged at a molecular resolution. This is primarily due to the low stability of the hydrogen bonds in ice under high-resolution microscopy conditions and a lack of methods to prepare compatible samples. Here, this presentation describes the first molecular-resolution imaging of ice crystallized from liquid water and the ice-water interface using high-resolution transmission electron microscopy (HRTEM). By encapsulating deionized (DI) water between two amorphous carbon (a-C) TEM grids and subsequently freezing it with liquid N 2 on a cryo sample stage, we generated two types of ice: non-equilibrium, condensed ice from the atmosphere and encapsulated ice from the DI water (Fig. 1A). Condensed ice usually shows irregular, spherulitic shapes (Fig. 1B). Selected area electron diffraction (SAED) shows that they are a mixture of cubic and hexagonal crystals (Fig. 1C). On the contrary, encapsulated ice forms thin films that contain large-area single-crystalline regions of hexagonal ice oriented along the [0001] zone axis (Fig. 1D). Differential electron energy-loss spectroscopy (EELS) confirmed the high purity of the encapsulated ice free from organic contaminations that are common in other encapsulation methods for HRTEM such as graphene liquid cells. These single-crystalline areas are robust under the electron beam up to ~100 e/Å 2 s. Aberration-corrected HRTEM imaging in these areas achieved a line resolution of ~1.3 Å (Fig. 1E and F). This platform allows us to study near-equilibrium ice structures and dynamics at an unprecedented spatial resolution (Fig. 2). For example, we discovered subdomain-rich regions near the defective crystal edges despite the structure appearing single-crystalline according to diffraction criteria. These subdomains connect via low-angle grain boundaries with flat energy landscapes as a function of tilt angles (according to simulations), showing the high tolerance of ice to defect structures. When we tuned the sample temperature and electron flux rate, we observed radiolysis-controlled bubble generation and dissolution in ice single crystals near a steady state of bubble dynamics. Furthermore, rich beam-induced melting and recrystallization dynamics were observed at the ice-water interface with lattice resolution. These data represent the first observation of the ice-water phase transformation at the sub-nanometer level. In summary, the methods developed in this work enabled molecular-resolution observations of ice and the ice-water interface and shed light on the microstructures and phase transformation pathways. Finer control on the temperature, electron irradiation profile, and imaging detector could eventually lead to real-time observation of ice nucleation in water and address long-standing questions in the nucleation pathways.

74 ATOMIC AND MOLECULAR PHYSICS↗

169 Tm ( n , γ ) cross section and statistical decay properties from measurements at the DANCE facility

Background: Radiative neutron capture on thulium, which is a monoisotopic element, plays a role in different applications such as nuclear astrophysics or nuclear burning environments. Considerable discrepancies—reaching 20%—exist between evaluations in the unresolved-resonance region. Furthermore, experimental data on statistical 𝛾 decay in odd-odd rare-earth nuclei is scarce. There are still open questions about the systematics of the so-called scissors mode in the 𝑀⁢1 photon strength function, especially in odd-odd nuclei. Purpose: This work is focused on two main topics—deriving experimental 169 Tm ⁢(𝑛,𝛾) cross section and studying statistical 𝛾 decay of 170 Tm, in particular properties of the scissors mode. Methods: The capture experiments to obtain experimental cross section were performed at the Los Alamos Neutron Science Center using the time-of-flight technique and employing the Detector for Advanced Neutron Capture Experiments. Measured coincident 𝛾-ray spectra were also compared with statistical simulations using the dicebox code to test different models of level density and photon strength functions. Results: The capture cross section was determined from 1.8 eV to 0.97 MeV, the broadest neutron-energy range ever measured for this isotope. Several new resonances have been observed. The statistical 𝛾 decay of 170 Tm cannot be reproduced without a scissors mode resonance centered at ≈ 3.3MeV. Conclusions: The measured cross section in the unresolved-resonance region is generally lower than the latest evaluations. The derived 169 Tm 𝑠-process abundance is expected to increase by a factor of 1.26, while the changes of the abundances of elements heavier than 169 Tm are in the order of 0.2%. The scissors mode properties in 170 Tm are similar to those deduced in previous analyses of neighboring nuclei 168 Er and 166 Ho .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of nuclear effects in neutrino-argon interactions using generalized kinematic imbalance variables with the MicroBooNE detector

We present a set of new generalized kinematic imbalance variables that can be measured in neutrino scattering. These variables extend previous measurements of kinematic imbalance on the transverse plane and are more sensitive to modeling of nuclear effects. We demonstrate the enhanced power of these variables using simulation and then use the MicroBooNE detector to measure them for the first time. We report flux-integrated single- and double-differential measurements of charged-current muon neutrino scattering on argon using a topology with one muon and one proton in the final state as a function of these novel kinematic imbalance variables. These measurements allow us to demonstrate that the treatment of charged current quasielastic interactions in genie version 2 is inadequate to describe data. As a result, they reveal tensions with more modern generator predictions particularly in regions of phase space where final state interactions are important.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of η c ( 1 S , 2 S ) and χ c J decays to 2 ( π + π − ) η via ψ ( 3686 ) radiative transitions

Based on ( 2712.4 ± 14.1 ) × 10 6 ψ ( 3686 ) decays collected with the BESIII detector, we have observed, for the first time, the hadronic decays of S- and P-wave charmonium states into 2 ( π + π − ) η via radiative transitions from ψ ( 3686 ) . The branching fraction of the decay η c ( 1 S ) → 2 ( π + π − ) η has a significant dependence on the interference pattern between η c ( 1 S ) and non- η c ( 1 S ) processes. We measure it in both the destructive and constructive interference scenarios for the first time. The mass and width of the η c ( 1 S ) are measured to be M = ( 2984.14 ± 0.13 ± 0.38 ) MeV / c 2 and Γ = ( 28.82 ± 0.11 ± 0.82 ) MeV , respectively. Clear signals for the decays of the χ c J ( J = 0 , 1 , 2 ) and the η c ( 2 S ) to 2 ( π + π − ) η are also observed for the first time, and the corresponding branching fractions are measured. The ratio of the branching fractions between the η c ( 2 S ) and η c ( 1 S ) decays is significantly lower than the theoretical prediction, which might suggest different dynamics in their decays. Published by the American Physical Society 2025

Ablikim, M.↗

Conceptual Design of DUNE Near Detector Superconducting Magnet System

The Deep Underground Neutrino Experiment (DUNE) has formed a near detector design group (NDDG) tasked with delivering a CDR by the end of 2019. The DUNE Near Detectors will be housed in an underground hall on the Fermilab site. The two main detector systems are a liquid argon detector and a high-pressure gas time projection chamber (HPgTPC). The HPgTPC requires a magnet that generates a 0.5 T solenoidal magnetic field in a large volume of 6 m diameter, and 5 m length. Herein, we present a superconducting magnet system design. We investigated: an open air core magnet with three coils, and a five coils system having two active fringe field shielding coils. Coils positions were optimized to obtain the specified field homogeneity in the magnet good field region, while minimizing the Lorentz forces and the superconductor volume. We discuss the magnetic, mechanical, and thermal conceptual designs.

43 PARTICLE ACCELERATORS↗

Characterization of Precipitation-Induced Radon Progeny Deposition Events Using a City-Scale Sensor Network

Networks of radiation detectors provide a platform for real-time radioactive source detection and identification in urban environments. Detection algorithms in these systems must adapt to naturally-occurring changes in background, which requires well-characterized relationships between precipitation events and their corresponding radiological signature. Here, we present a quantitative and qualitative description of rain-induced radon progeny deposition events occurring in Chicago from September 2023 to February 2024. We measure ambient gamma radiation levels, precipitation rate, temperature, pressure, and relative humidity in a network of sensor nodes. For each identified precipitation period, we decompose spectra into static- and radon-associated components as defined by a non-negative matrix factorization (NMF) algorithm. We find a consistent power-law relationship between a precipitation-dependent peak of the radon progeny proxy (RPP) and the peak strength of the radon-associated NMF component for most precipitation events. We conduct a case study of a rainfall period with abnormally high levels of implied radon progeny concentration and describe its temporal and spatial evolution. We hypothesize that this phenomenon is due to the air mass path that intersects a uranium-rich region of Wyoming. Finally, we cluster precipitation events into three distinct categories. One category roughly corresponds to events with deep low-pressure systems and high relative radon concentration, while another is characteristic of light stratiform rain with slightly higher temperatures and intermediate relative radon concentration. The third category appears to contain weak-gradient or lake breeze convection showers with intermittent precipitation and low relative radon concentration. These findings suggest that radiological anomaly detection could be improved by training unique background models corresponding to each category of meteorological event.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge response and energy calibration of ProtoDUNE-

ProtoDUNE-SP is a test bed liquid argon time projection chamber (LArTPC) for the far detector of the Deep Underground Neutrino Experiment (DUNE). This LArTPC was calibrated using cosmic-ray cathode-crossing muons, electric field maps, and purity-monitor data to correct for nonuniformities in the detector response and cosmic-ray stopping muons to perform the absolute energy scale calibration for further physics analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗