Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Integration of thermal and environmental control systems during Space Station Freedom early assembly phase

An overview of Space Station Freedom Thermal Control System (TCS) and Environmental Control and Life Support System (ECLSS) integration is presented for Stages 2-6. Particular attention is given to issues associated with integrating five distinct, functioning spacecraft with hardware not specifically designed for intermediate stages. Areas specifically addressed include integrated ECLSS temperature and humidity control performance, thermal load balancing, performance and verification requirements, interface verification procedures, TCS activation sequence, resource allocation and Space Shuttle integration.

Di Pietro, David A.↗

Simulated performance of biomass gasification based combined power and refrigeration plant for community scale application

Thermal performance analysis and sizing of a biomass gasification based combined power and refrigeration plant (CPR) is reported in this study. The plant is capable of producing 100 kWe of electrical output while simultaneously producing a refrigeration effect, varying from 28-68 ton of refrigeration (TR). The topping gas turbine cycle is an indirectly heated all-air cycle. A combustor heat exchanger duplex (CHX) unit burns producer gas and transfer heat to air. This arrangement avoids complex gas cleaning requirements for the biomass-derived producer gas. The exhaust air of the topping GT is utilized to run a bottoming ammonia absorption refrigeration (AAR) cycle via a heat recovery steam generator (HRSG), steam produced in the HRSG supplying heat to the generator of the refrigeration cycle. Effects of major operating parameters like topping cycle pressure ratio (r{sub p}) and turbine inlet temperature (TIT) on the energetic performance of the plant are studied. Energetic performance of the plant is evaluated via energy efficiency, required biomass consumption and fuel energy savings ratio (FESR). The FESR calculation method is significant for indicating the savings in fuel of a combined power and process heat plant instead of separate plants for power and process heat. The study reveals that, topping cycle attains maximum power efficiency of 30%in pressure ratio range of 8-10. Up to a certain value of pressure ratio the required air flow rate through the GT unit decreases with increase in pressure ratio and then increases with further increase in pressure ratio. The capacity of refrigeration of the AAR unit initially decreases up to a certain value of topping GT cycle pressure ratio and then increases with further increase in pressure ratio. The FESR is found to be maximized at a pressure ratio of 9 (when TIT=1100°C), the maximum value being 53%. The FESR is higher for higher TIT. The heat exchanger sizing is also influenced by the topping cycle pressure ratio and GT-TIT.

09 BIOMASS FUELS↗

Solar energy system performance evaluation: Seasonal report for Contemporary-Manchester, Manchester, New Hampshire

The operational and thermal performance of the solar energy system, Contemporary-Manchester, is described. The system was designed by Contemporary Systems Incorporated to provide space heating and domestic hot water preheating for a three story dwelling located on the New Hampshire Vocational Technical College campus, Manchester, New Hampshire. The net fossil energy savings for the period from March, 1979 to February, 1980 was 14.52 million Btu. However, the performance of the system must be degraded due to the fact that the building was unoccupied throughout the data assessment and analysis period. The unoccupied status prevented the normal adjustment of heating and ventilating controls for maintenance of comfort levels within the building. This lack of occupancy also prevented the typical family hot water usage, which would have allowed for more realistic evaluation of the hot water subsystem.

Source record↗

Final cryogenic performance report for the NASA Cosmic Background Explorer (COBE)

The cryogenic operation of NASA's Cosmic Background Explorer (COBE) ended on September 21, 1990, with the depletion of the liquid helium cryogen. The COBE had successfully completed more than 10 months of dewar and instrument operation. We report on the cryogenic performance of the COBE dewar and of the two cryogenic instruments throughout the mission lifetime. We discuss the steady state dewar performance, and the dewar and instrument response to a variety of transient thermal phenomena, including external radiation (from the earth and the sun) and instrument power variation. We present the effectiveness of using approximate mass gauging techniques in determining the liquid helium content. Finally we discuss the dewar behavior during the depletion of the helium, and the expected thermal performance of the dewar cryogen tank and the cryogenic instruments as they approach final thermal equilibrium.

Volz, S. M.↗

Statistical and sensitivity analysis of failing rods in EPR LBLOCA

A statistical fuel failure analysis procedure has been developed, and is now applied in full scale to a large break loss-of-coolant accident (LBLOCA) scenario in EPR-type nuclear power plant. The goal is to statistically determine the number of failing fuel rods. It is also important to bring out the underlying causes for rod failures, and therefore a sensitivity analysis procedure for the preceding complex calculation chain is outlined and adopted. In order to produce a statistically reliable estimation on the number of failing rods, a large number of simulations are required. In the analysis, single rods are simulated with the coupled fuel performance - thermal hydraulics code FRAPTRAN-GENFLO. The statistically varied factors are divided into global and local by their range of influence. Transient thermal hydraulic and power history boundary conditions and model parameters are global and affect all the rods. Fuel rod manufacturing parameters and other rod position related factors are local and are related to a certain rod. The number of global scenarios is 59 as dictated by the Wilks' formula, and 1000 randomly sampled rods are simulated in each scenario. The thermal hydraulic and transient power boundary conditions for the fuel performance code are calculated with a statistical version of the system code APROS. The steady-state irradiation histories are simulated with FRAPCON, and the steady-state power histories used as boundary conditions for FRAPCON are obtained from SIMULATE calculations. Thus, a multistage calculation chain is required to consolidate the procedure. As an outcome, in the worst global scenario, 1.4% of the simulated rods failed. It can be concluded that the Finnish safety regulations, i.e. max. 10% of the rods allowed to fail, are met. In order to find out which input parameters have significance to the outcome of the analysis, a sensitivity analysis is done. At the moment, only the worst global scenario is considered but later on it is possible to include also the sensitivities of the global factors. Due to complexity of the existing data, first the relevant input parameters for the sensitivity analysis have to be specified. Data visualization with a cobweb graph is used for the screening. Then, selected sensitivity measures are calculated between the chosen input and output parameters. The sensitivity indices calculated are the Borgonovo's delta measure, the first order Sobol sensitivity index, and squared Pearson correlation coefficients. The first mentioned is a novelty in this context. As an outcome, the most relevant parameters with respect to the cladding integrity were determined to be the decay heat power during the transient, the thermal hydraulic conditions in the rod's location in the reactor, and the steady-state irradiation history of the rod as represented in this analysis by the rod burnup. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Using Models to Predict the Hygrothermal Performance of Equipment and Piping Insulation

The development of hygrothermal models began in earnest in the 1990s, with the initial emphasis on the performance of building envelope systems. Numerous large-scale building envelope failures associated with water intrusion drove this development. The physical principles of moisture transfer that apply to building envelopes are equally valid for equipment and piping insulation systems. The main advantage of modeling is that carefully characterized models can predict the long-term hygrothermal performance of any system under different climatic and interior conditions. Thermal insulations are commonly used on outdoor equipment and piping for different applications, such as thermal energy conservation and freeze protection. The insulated equipment usually experiences moisture intrusion due to many factors, such as the duration and frequency of moisture exposure, equipment operating temperature, insulation type, exposure temperature, weather conditions, equipment thermal cycling, and weatherproofing condition. Hygrothermal models have been employed to estimate the moisture pickup of insulated equipment and piping systems, as well as the moisture redistribution and subsequent change in thermal performance as these systems become contaminated with moisture. The hygrothermal model provides insights on the parameters influencing the time of wetness, the lateral redistribution of moisture along the pipe away from the leak, and the ease by which water escapes the insulation/jacketing systems. It has been shown that the moisture leak effect decreases rapidly with distance from the leak and that one- and two-dimensional hygrothermal simulations help to identify solutions to reduce conditions that support corrosion under insulation (CUI).

Shrestha, Som↗

High-temperature thermal conductivity measurements of macro-porous graphite

Graphite is a unique material for high temperature applications and will likely become increasingly important as we attempt to electrify industrial applications. Here, we investigate the thermal properties of low-quality, macro-porous graphite to determine the tradeoff between quality and thermal performance. We use laser flash analysis (LFA) to measure the thermal diffusivity of graphite at high temperatures. Due to the large pores in the graphite samples preventing uniform laser flash heating, we first apply a thick coating to achieve the required flat, parallel surfaces for LFA measurements. We then develop a methodology to extract properties of the sample from the diffusivity measurements, based on finite element modeling of a variety of sample/coating interface profiles. Validating the methodology against a reference sample demonstrates a mean absolute percentage error of 8.5%, with potential improvement with better sample characterization. We show low-quality graphite has a thermal conductivity of ~10 W/m/K up to 1000 °C, which is an order of magnitude lower than high-quality graphite, but contributions from photon conductivity may result in higher conductivities at higher temperatures. Overall, we demonstrate an approach for measuring thermal properties of macro-porous materials at high temperatures, and apply the approach to measuring thermal conductivity of porous graphite, which will aid in the design of hightemperature systems for cost-competitive decarbonization.

Verma, Shomik↗

Design Concepts for Co-Production of Power, Fuels & Chemicals Via Coal/Biomass Mixtures

The overall goal of the program is to develop design concepts, incorporating advanced technologies in areas such as oxygen production, feed systems, gas cleanup, component separations and gas turbines, for integrated and economically viable coal and biomass fed gasification facilities equipped with carbon capture and storage for the following scenarios: (i) coproduction of power along with hydrogen, (ii) coproduction of power along with fuels, (iii) coproduction of power along with petrochemicals, and (iv) coproduction of power along with agricultural chemicals. To achieve this goal, specifically the following objectives are met in this proposed project: (i) identify advanced technology options and innovative preliminary design concepts that synergistically integrate plant subsections, (ii) develop steady state system simulations to predict plant efficiency and environmental signature, (iii) develop plant cost estimates by capacity factoring major subsystems or by major equipment items where required, and then capital, operating and maintenance cost estimates, and (iv) perform techno- economic analyses for the above described coproduction facilities. Thermal efficiencies for the electricity only cases with 90% carbon capture are 38.26% and 36.76% (HHV basis) with the bituminous and the lignite feedstocks respectively. For the coproduction cases (where 50% of the energy exported is in the form of electricity), the electrical efficiency, as expected, is highest for the hydrogen coproduction cases while lowest for the higher alcohols (ethanol) coproduction cases. The electrical efficiencies for Fischer-Tropsch coproduction cases are slightly higher than those for the methanol coproduction cases but it should be noted that the methanol (as well as the higher alcohol) coproduction cases produce the finished coproduct while the Fischer-Tropsch coproduction cases produce a coproduct that requires further processing in a refinery. The cross comparison of the thermal performance between the various coproduct cases is further complicated by the fact that the carbon footprint is not the same when carbon leaving with the coproduct are accounted for. The economic analysis and demand for a particular coproduct in the market place is a more meaningful comparison of the various coproduction scenarios. The first year cost of electricity calculated for the bituminous coal is $\$$102.9/MWh while that for the lignite is $\$$108.1/MWh. The calculated cost of hydrogen ranged from $\$$1.42/kg to $\$$2.77/kg depending on the feedstock, which is lower than the DOE announced hydrogen cost goal of $\$$3.00/kg in July 14, 2005. Methanol cost ranged from $\$$345/MT to $\$$617/MT, while the market price is around $\$$450/MT. For Fischer-Tropsch liquids, the calculated cost ranged from $\$$65/bbl to $\$$112/bbl, which is comparable to the current market price of crude oil at around $\$$100/bbl. It should be noted, however, that F-T liquids contain no sulfur and nitrogen compounds. The calculated cost of alcohol ranged from $\$$4.37/gal to $\$$5.43/gal, while it ranged from $\$$2.20/gal to $\$$3.70/gal in a DOE funded study conducted by Louisiana State University. The Louisiana State University study consisted of a significantly larger plant than our study and benefited from economies of scale. When the plant size in our study is scaled up to similar size as in the Louisiana State University study, cost of alcohol is then reduced to a range of $\$$3.24/gal to $\$$4.28/gal, which is comparable. Urea cost ranged from $\$$307/MT to $\$$428/MT, while the market price is around $\$$480/MT.

20 FOSSIL-FUELED POWER PLANTS↗

Analytic and experimental evaluation of shadow shields and their support members for thermal control of space vehicles

The thermal performance of shadow shields, and their support struts, for the thermal protection of cryogenic propellants in a simulated deep-space environment was investigated analytically and experimentally. Very low overall heat-transfer rates were obtained when highly reflective aluminized Mylar shadow shields were used. The thermal interactions between the shields and support struts were investigated with fair to good agreement between the analysis and experimental data. The exterior surface of both fiberglass and titanium struts was coated to reduce the heat input into the test tank. The vacuum level inside the test facility strongly influenced the heat-transfer rates.

Boyle, R. J.↗

Apparatus for measurement of thermal conductivity of insulation systems subjected to extreme temperature differences

Advanced aerospace designs require thermal insulation systems which are consistent with cryogenic fluids, high thermal loads, and design restrictions such as weight and volume. To evaluate the thermal performance of these insulating systems, an apparatus capable of measuring thermal conductivity using extreme temperature differences (27 to 1100 K) is being developed. This system is described along with estimates of precision and accuracy in selected operating conditions. Preliminary data are presented.

Dube, W. P.↗

Effect of Cyclic Aeroconvective Heating on Flexible Thermal Insulations

This paper describes the effect of cyclic aeroconvective heating on the thermal performance of ceramic flexible insulations considered for potential use as thermal protection systems or thermal insulations for future hypersonic vehicles such as the Reusable Launch Vehicles (RLV's) and other applications where structures require thermal protection from severe heating. The thermal response of these materials after exposure to cyclic aeroconvective heating from a plasma arc is described. The thermal insulations evaluated were Composite Flexible Blanket Insulations composed of an outer layer of aluminoborosilicate fabric and alumina insulation. The insulations were evaluated with and without a high emissivity coating. These insulations were exposed to the plasma arc stream for nine minutes reaching surface temperatures of 1150 C and a heat flux of 10.5 W/sq cm. Insulations were exposed three, six, or nine times in order to demonstrate reusability and to determine the effect oi coatings on the surface durability of these insulations. Test results demonstrated the capability of these insulations to protect either composite or metallic structures from high heating environments. It is shown that high emittance coatings reduce backface temperatures. The durability of these insulations when impacted at low velocities was also demonstrated. The interaction of the coatings with the ceramic fibers was characterized. An analytical thermal model was utilized to correlate experimental thermal test results with calculated values.

Kourtides, Demetrius A.↗

Results of Use of Heat Flux Sensors on Liquid Hydrogen Tanks

Heat flux sensors were used to characterize the performance of insulation on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER), a large-scale test article designed to simulate upper stage cryogenic propellant tank thermal performance in simulated space environments. Usually, the insulation heat loads are derived from calculations removing all other heat sources and attributing the residual heat load to the insulation system. Testing for SHIIVER included the tank being just insulated with spray-on-foam insulation as well as covering the domes with multilayer insulation while leaving the barrel section insulated with spray-on-foam. Heat flux sensors were located at multiple locations on both domes as well as on the barrel section of the tank. Results from the SHIIVER testing using the heat flux sensors are compared to other calculated heat inputs for both liquid nitrogen and liquid hydrogen testing as a function of tank fill level. Further investigation into the transient nature of the SHIIVER testing including the heat flux sensors provided insight into heat flow patterns that may not have been otherwise seen using temperature sensors and calculated insulation heat loads. While the demonstrated uncertainties in the absolute values in the heat flux sensors are high, the values and the trends match well with other calculation methods. The results of SHIIVER allow for the use of heat flux sensors for measurements of insulation performance and dynamic system thermal response for future applications.

Cryogenic Fluid Management↗

Results of Use of Heat Flux Sensors on Liquid Hydrogen Tanks

ABSTRACT: Heat flux sensors were used to characterize the performance of insulation on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER), a large-scale test article designed to simulate upper stage cryogenic propellant tank thermal performance in simulated space environments. Usually, the insulation heat loads are derived from calculations removing all other heat sources and attributing the residual heat load to the insulation system. Testing for SHIIVER included the tank being just insulated with spray-on-foam insulation as well as covering the domes with multilayer insulation while leaving the barrel section insulated with spray-on-foam. Heat flux sensors were located at multiple locations on both domes as well as on the barrel section of the tank. Results from the SHIIVER testing using the heat flux sensors are compared to other calculated heat inputs for both liquid nitrogen and liquid hydrogen testing as a function of tank fill level. Further investigation into the transient nature of the SHIIVER testing including the heat flux sensors provided insight into heat flow patterns that may not have been otherwise seen using temperature sensors and calculated insulation heat loads. While the demonstrated uncertainties in the absolute values in the heat flux sensors are high, the values and the trends match well with other calculation methods. The results of SHIIVER allow for the use of heat flux sensors for measurements of insulation performance and dynamic system thermal response for future applications.

Cryogenic Fluid Management↗

Thermal Management Key Performance Parameter Development and System Analysis for the SUSAN Electrofan Aircraft

A set of key performance parameters (KPPs) for thermal management system (TMS) components was developed for use in system sizing and analysis. These KPPs were defined at three different levels of performance corresponding to different ranges of Technology Readiness Levels. KPP values were determined based on a large dataset that includes analysis and testing data from literature, NASA-funded research, and commercial product datasheets. These KPPs were then used to perform a TMS sizing and analysis of the SUbsonic Single Aft eNgine (SUSAN) aircraft. Total TMS mass, power consumption, and drag is quantified at each KPP level, showing decreasing trends as the level of technology improves.

thermal management↗