Clinical Application of a New Indwelling Catheter with a Side-Hole and Spirally Arranged Shape-Memory Alloy for Hepatic Arterial Infusion Chemotherapy

A new indwelling catheter, G-spiral (GSP), was developed for hepatic arterial infusion chemotherapy (HAIC) by way of an implanted catheter-port system (CPS). Here we evaluated its physical properties and the outcomes of its clinical use. The GSP vessel-fixing power and its ability to follow a guidewire were determined with a vascular in vitro model, and Student t test was used to determine statistical significance (P < 0.05). A retrospective analysis was performed to evaluate the technical success rate and to identify the clinical complications associated with radiologic CPS implantation with GSP in 65 patients with unresectable hepatic tumors. The mean vessel-fixing power of the GSP (14.4 g) significantly differed from that of a GSP with a cut shape-memory alloy (3.3 g). The mean resistance to following the guidewire displayed by the GSP (88.5 g) was significantly less than that for a 5F W-spiral (106.3 g) or 4F Cobra-type angiographic catheter (117.8 g). The CPS was placed successfully in 64 of 65 cases (98.5%). Hepatic artery occlusion was observed in one case. Occlusion, cracking, and infection of CPS were observed in one, two, and one case, respectively. The GSP is a highly useful indwelling catheter that can be used for HAIC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Visibility of Hypovascularized Liver Tumors during Intra-Arterial Therapy Using Split-Bolus Single-Phase Cone Beam CT

Purpose: To validate a split-bolus contrast injection protocol for single-phase CBCT in terms of detectability of hypovascular liver tumors compared to digital subtraction angiography (DSA). Materials and Methods: In this retrospective, single-center study, 20 consecutive patients with in total 77 hypovascularized tumors referred for intra-arterial therapy received a split-bolus single-phase CBCT. Two readers rated the visibility of the target tumors scheduled for embolization in CBCT and DSA compared to the pre-interventional multiphasic CT or MRI used as reference on a 3-point scoring system (1 = optimal, 3 = not visible) and catheter-associated artifacts (1 = none, 3 = extended). SNR, CNR and contrast values were derived from 37 target tumors in CBCT and MRI. Statistical analysis included the kappa test to determine interrater reliability, the Friedman’s test for the inter-modality comparison evaluating tumor visibility in DSA and CBCT as well as for quantitative assessment. Post hoc analysis included the Wilcoxon signed-rank test. p values < 0.05 were considered significant. Results: Ninety percentage of target tumors were rated as visible in CBCT and 37.5% in DSA (p < 0.001). 70.1% of pre-interventionally detected hypovascularized tumors were depicted with CBCT and 31.2% by DSA (p < 0.001). 7.8% of known tumors were outside the FOV. Quantitative assessment showed higher image contrasts in CBCT (1.91 ± 7.01) compared to hepatobiliary-phase MRI (0.29 ± 0.14, p = 0.003) and to portal-venous (p.v.) MRI (0.31 ± 0.13, p < 0.001), but higher CNR for MRI (1.18 ± 0.80; 13.92 ± 15.82; 13.79 ± 6.65). Conclusion: In conclusion, the split-bolus single-phase CBCT detects significantly more hypovascularized liver tumors compared to DSA performed through the proper hepatic artery with high image contrasts. Level of Evidence: Level III, diagnostic study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evolution of damage and failure in an additively manufactured 316L SS structure: experimental reinvestigation of the third Sandia fracture challenge

The third Sandia Fracture Challenge (SFC3) was a benchmark problem for comparing experimental and simulated ductile deformation and failure in an additively manufactured (AM) 316L stainless steel structure. One surprising observation from the SFC3 was the Challenge-geometry specimens had low variability in global load versus displacement behavior, attributed to the large stress-concentrating geometric features dominating the global behavior, rather than the AM voids that tend to significantly influence geometries with uniform cross-sections. This current study reinvestigates the damage and failure evolution of the Challenge-geometry specimens, utilizing interrupted tensile testing with micro-computed tomography (micro-CT) scans to monitor AM void and crack growth from a virgin state through complete failure. This study did not find a correlation between global load versus displacement behavior and AM void attributes, such as void volume, location, quantity, and relative size, which incidentally corroborates the observation from the SFC3. However, this study does show that the voids affect the local behavior of damage and failure. Surface defects (i.e. large voids located on the surface, far exceeding the nominal surface roughness) that were near the primary stress concentration affected the location of crack initiation in some cases, but they did not noticeably affect the global response. The fracture surfaces were a combination of classic ductile dimples and crack deviation from a more direct path favoring intersection with AM voids. Even though the AM voids promoted crack deviation, pre-test micro-CT scan statistics of the voids did not allow for conclusive predictions of preferred crack paths. This study is a first step towards investigating the importance of voids on the ductile failure of AM structures with stress concentrations.

36 MATERIALS SCIENCE↗

Speleogenesis, geometry, and topology of caves: A quantitative study of 3D karst conduits

Karst systems are hierarchically spatially organized three-dimensional (3D) networks of conduits behaving as drains for groundwater flow. Recently, geostatistical approaches proposed to generate karst networks from data and parameters stemming from analogous observed karst features. Other studies have qualitatively highlighted relationships between speleogenetic processes and cave patterns. However, few studies have been performed to quantitatively define these relationships. This paper reports a quantitative study of cave geometries and topologies that takes the underlying speleogenetic processes into account. In order to study the spatial organization of caves, a 3D numerical database was built from 26 caves, corresponding to 621 km of cumulative cave passages representative of the variety of karst network patterns. The database includes 3D speleological surveys for which the speleogenetic context is known, allowing the polygenic karst networks to be divided into 48 monogenic cave samples and classified into four cave patterns: vadose branchwork (VB), water-table cave (WTC), looping cave (LC), and angular maze (AM). Eight morphometric cave descriptors were calculated, four geometrical parameters (width-height ratio, tortuosity, curvature, and vertical index) and four topological ones (degree of node connectivity, α and γ graph indices, and ramification index) respectively. The results were validated by statistical analyses (Kruskal-Wallis test and PCA). The VB patterns are clearly distinct from AM ones and from a third group including WTC and LC. A quantitative database of cave morphology characteristics is provided, depending on their speleogenetic processes. These characteristics can be used to constrain and/or validate 3D geostatistical simulations. This study shows how important it is to relate the geometry and connectivity of cave networks to recharge and flow processes. Conversely, the approach developed here provides proxies to estimate the evolution of the vadose zone to epiphreatic and phreatic zones in limestones from the quantitative analysis of existing cave patterns.

58 GEOSCIENCES↗

A data driven approach for cross-slip modelling in continuum dislocation dynamics

Cross-slip is a thermally activated process by which screw dislocation changes its glide plane to another slip plane sharing the same Burgers vector. The rate at which this process happens is determined by a Boltzmann type expression that is a function of the screw segment length and the stress acting on the dislocation. In continuum dislocation dynamics (CDD), the information regarding the length of the screw dislocation segment and local stress state on dislocations are lost due to the coarse-grained representation of the density. Here, in this work, a data driven approach to characterize the lost information by analyzing the discrete dislocation configurations is proposed to enable cross-slip modeling in the CDD framework in terms of the coarse-grained dislocation density and stress fields. The analysis showed that the screw segment length follows an exponential distribution, and the stress fluctuations, defined as the difference between the stress on the dislocations and the mean field stress in CDD, follows a Lorentzian distribution. A novel approach for cross slip implementation in CDD employing the screw segment length and stress fluctuation statistics was proposed and rigorously tested by comparing the CDD cross-slip rates with discrete dislocation dynamics (DDD) rates. This approach has been applied in conjunction with three cross-slip models used in DDD simulations differing mainly in the functional form of cross slip activation energy. It was found that different cross-slip activation energy formulations yielded different cross-slip rates, yet the effect on mechanical stress-strain response and dislocation density evolution was minimal for the [001] type loading.

42 ENGINEERING↗

Use of Molecular Imaging to Predict Clinical Outcome in Patients With Rectal Cancer After Preoperative Chemotherapy and Radiation

Purpose: To correlate changes in 2-deoxy-2-[18F]fluoro-D-glucose (18-FDG) positron emission tomography (PET) (18-FDG-PET) uptake with response and disease-free survival with combined modality neoadjuvant therapy in patients with locally advanced rectal cancer. Methods and Materials: Charts were reviewed for consecutive patients with ultrasound-staged T3x to T4Nx or TxN1 rectal adenocarcinoma who underwent preoperative chemoradiation therapy at Fox Chase Cancer Center (FCCC) or Robert H. Lurie Comprehensive Cancer Center of Northwestern University with 18-FDG-PET scanning before and after combined-modality neoadjuvant chemoradiation therapy . The maximum standardized uptake value (SUV) was measured from the tumor before and 3 to 4 weeks after completion of chemoradiation therapy preoperatively. Logistic regression was used to analyze the association of pretreatment SUV, posttreatment SUV, and % SUV decrease on pathologic complete response (pCR), and a Cox model was fitted to analyze disease-free survival. Results: A total of 53 patients (FCCC, n = 41, RLCCC, n = 12) underwent pre- and postchemoradiation PET scanning between September 2000 and June 2006. The pCR rate was 31%. Univariate analysis revealed that % SUV decrease showed a marginally trend in predicting pCR (p = 0.08). In the multivariable analysis, posttreatment SUV was shown a predictor of pCR (p = 0.07), but the test results did not reach statistical significance. None of the investigated variables were predictive of disease-free survival. Conclusions: A trend was observed for % SUV decrease and posttreatment SUV predicting pCR in patients with rectal cancer treated with preoperative chemoradiation therapy. Further prospective study with a larger sample size is warranted to better characterize the role of 18-FDG-PET for response prediction in patients with rectal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three or Four Fractions of 4-5 Gy per Week in Postoperative High-Dose-Rate Brachytherapy for Endometrial Carcinoma

Purpose: To evaluate the results of high-dose-rate brachytherapy (HDRBT) using a schedule of three or four fractions per week, when possible, in 89 patients on local control and toxicity in postoperative treatment of endometrial carcinoma. The effect of the overall HDRBT treatment time (OTT) on toxicity was also evaluated. Patients and Methods: Federation Internationale de Gynecologie Obstetrique Stage: 24 IB, 45 IC, 4 IIA, 6 IIB, 4 IIIA, 2 IIIB, and 4 IIIC. Radiotherapy: Group 1-67 of 89 patients received external beam irradiation (EBI; 44-50 Gy) plus HDRBT (3 fractions of 4-6 Gy); Group 2-22 of 89 patients received HDRBT alone (6 fractions of 4-5 Gy). OTT: Group 1-HDRBT was completed in a median of 5 days in 32 patients and in >5 days in 35; Group 2-HDRBT was completed in <15 days in 11 patients and in {>=}16 days in 11. Toxicity was evaluated using Radiation Therapy Oncology Group scores and the bioequivalent dose (BED) study was performed in vaginal mucosa surface. Statistics included Student's t test, chi-square test, and receiving operator curves. Results: With a mean follow-up of 31 months (range, 6-70), 1 of 89 patients had vaginal relapse. Early toxicity appeared in 8 of 89 (9%) patients and was resolved. Late toxicity appeared in 13/89 (14%): vaginal nine Grade 1, three Grade 2, one Grade 4; bladder two Grade 2; rectal three Grade 1, one Grade 2. No differences were found in relation to OTT in Groups 1 and 2. Mean BED was 88.48 Gy in Group 1 and 165.28 Gy in Group 2. Cases with Grade 2 late vaginal toxicity received >75 Gy after EBI and >165 Gy in Group 2. Conclusions: Three fractions of 4-5 Gy in 3-5 days after EBI or 6 fractions in <15 days in patients receiving HDRBT alone was a safe treatment in relation to toxicity and local control. Vaginal surface BED less than 75 Gy after EBI and less than 160 Gy in HDRBT alone may be safe to avoid G2 toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Metabolic Response on Post-therapy FDG-PET Predicts Patterns of Failure After Radiotherapy for Cervical Cancer

Purpose: To determine the patterns of failure in patients with cervical cancer treated with definitive radiotherapy and evaluated for metabolic response with early posttherapy {sup 18}F-fluorodeoxyglucose positron emission tomography (FDG-PET). Methods and Materials: The records of 238 patients with cervical cancer were reviewed. All patients were treated with a combination of external radiotherapy and intracavitary brachytherapy. Two hundred and nineteen patients (92%) received concurrent chemotherapy. All patients underwent pretreatment FDG-PET, and posttherapy FDG-PET was performed within 8-16 weeks of the completion of radiotherapy. Posttherapy FDG-PET results were categorized as complete metabolic response (CMR), partial metabolic response (PMR), and progressive disease (PD). Failure patterns were categorized as none, isolated local failure (central pelvis {+-} pelvic lymph nodes), distant failure, or combined local plus distant failure. Results: Of the 91 patients (38%) who had a recurrence, 22 had isolated local failures, and 69 had distant failures (49 distant failures and 20 combined local plus distant failures). Of the 173 patients with a CMR, 40 (23%) experienced treatment failure. All 25 patients with PD experienced treatment failure, which was distant in 24 patients (96%). Among the 40 patients with PMR, no failure has been observed for 14 patients (35%). Of the 26 failures within the PMR group, 15 (58%) were limited to the pelvis. Differences in the patterns of failure between the three groups (CMR, PMR, PD) were statistically significant (chi-square test; p < 0.0001). Conclusions: The majority of failures after definitive radiotherapy for cervical cancer include distant failures, even in the setting of concurrent chemotherapy. PMR within the cervix or lymph nodes is more commonly associated with isolated local recurrence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Comparison of Combined Intensity-Modulated Radiotherapy (IMRT) and Proton Therapy Versus IMRT Alone for Pelvic and Para-Aortic Radiotherapy in Gynecologic Malignancies

Purpose: To perform a dosimetric comparison of intensity-modulated radiotherapy (IMRT), passive scattering proton therapy (PSPT), and intensity-modulated proton therapy (IMPT) to the para-aortic (PA) nodal region in women with locally advanced gynecologic malignancies. Methods and Materials: The CT treatment planning scans of 10 consecutive patients treated with IMRT to the pelvis and PA nodes were identified. The clinical target volume was defined by the primary tumor for patients with cervical cancer and by the vagina and paravaginal tissues for patients with endometrial cancer, in addition to the regional lymph nodes. The IMRT, PSPT, and IMPT plans were generated using the Eclipse Treatment Planning System and were analyzed for various dosimetric endpoints. Two groups of treatment plans including proton radiotherapy were created: IMRT to pelvic nodes with PSPT to PA nodes (PSPT/IMRT), and IMRT to pelvic nodes with IMPT to PA nodes (IMPT/IMRT). The IMRT and proton RT plans were optimized to deliver 50.4 Gy or Gy (relative biologic effectiveness [RBE)), respectively. Dose-volume histograms were analyzed for all of the organs at risk. The paired t test was used for all statistical comparison. Results: The small-bowel V{sub 20}, V{sub 30}, V{sub 35}, andV{sub 40} were reduced in PSPT/IMRT by 11%, 18%, 27%, and 43%, respectively (p < 0.01). Treatment with IMPT/IMRT demonstrated a 32% decrease in the small-bowel V{sub 20}. Treatment with PSPT/IMRT showed statistically significant reductions in the body V{sub 5-20}; IMPT/IMRT showed reductions in the body V{sub 5-15}. The dose received by half of both kidneys was reduced by PSPT/IMRT and by IMPT/IMRT. All plans maintained excellent coverage of the planning target volume. Conclusions: Compared with IMRT alone, PSPT/IMRT and IMPT/IMRT had a statistically significant decrease in dose to the small and large bowel and kidneys, while maintaining excellent planning target volume coverage. Further studies should be done to correlate the clinical significance of these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accuracy and Utility of Deformable Image Registration in {sup 68}Ga 4D PET/CT Assessment of Pulmonary Perfusion Changes During and After Lung Radiation Therapy

Purpose: Measuring changes in lung perfusion resulting from radiation therapy dose requires registration of the functional imaging to the radiation therapy treatment planning scan. This study investigates registration accuracy and utility for positron emission tomography (PET)/computed tomography (CT) perfusion imaging in radiation therapy for non–small cell lung cancer. Methods: {sup 68}Ga 4-dimensional PET/CT ventilation-perfusion imaging was performed before, during, and after radiation therapy for 5 patients. Rigid registration and deformable image registration (DIR) using B-splines and Demons algorithms was performed with the CT data to obtain a deformation map between the functional images and planning CT. Contour propagation accuracy and correspondence of anatomic features were used to assess registration accuracy. Wilcoxon signed-rank test was used to determine statistical significance. Changes in lung perfusion resulting from radiation therapy dose were calculated for each registration method for each patient and averaged over all patients. Results: With B-splines/Demons DIR, median distance to agreement between lung contours reduced modestly by 0.9/1.1 mm, 1.3/1.6 mm, and 1.3/1.6 mm for pretreatment, midtreatment, and posttreatment (P<.01 for all), and median Dice score between lung contours improved by 0.04/0.04, 0.05/0.05, and 0.05/0.05 for pretreatment, midtreatment, and posttreatment (P<.001 for all). Distance between anatomic features reduced with DIR by median 2.5 mm and 2.8 for pretreatment and midtreatment time points, respectively (P=.001) and 1.4 mm for posttreatment (P>.2). Poorer posttreatment results were likely caused by posttreatment pneumonitis and tumor regression. Up to 80% standardized uptake value loss in perfusion scans was observed. There was limited change in the loss in lung perfusion between registration methods; however, Demons resulted in larger interpatient variation compared with rigid and B-splines registration. Conclusions: DIR accuracy in the data sets studied was variable depending on anatomic changes resulting from radiation therapy; caution must be exercised when using DIR in regions of low contrast or radiation pneumonitis. Lung perfusion reduces with increasing radiation therapy dose; however, DIR did not translate into significant changes in dose–response assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling treatment couches in the Pinnacle treatment planning system: Especially important for arc therapy

This study is to demonstrate the importance and a method of properly modeling the treatment couch for dose calculation in patient treatment using arc therapy. The 2 treatment couch tops—Aktina AK550 and Elekta iBEAM evo—of Elekta LINACs were scanned using Philips Brilliance Big Bore CT Simulator. Various parts of the couch tops were contoured, and their densities were measured and recorded on the Pinnacle treatment planning system (TPS) using the established computed tomography density table. These contours were saved as organ models to be placed beneath the patient during planning. Relative attenuation measurements were performed following procedures outlined by TG-176 as well as absolute dose comparison of static fields of 10 × 10 cm{sup 2} that were delivered through the couch tops with that calculated in the TPS with the couch models. A total of 10 random arc therapy treatment plans (5 volumetric-modulated arc therapy [VMAT] and 5 stereotactic body radiation therapy [SBRT]), using 24 beams, were selected for this study. All selected plans were calculated with and without couch modeling. Each beam was evaluated using the Delta{sup 4} dosimetry system (Delta{sup 4}). The Student t-test was used to determine statistical significance. Independent reviews were exploited as per the Imaging and Radiation Oncology Core head and neck credentialing phantom. The selected plans were calculated on the actual patient anatomies with and without couch modeling to determine potential clinical effects. Large relative beam attenuations were noted dependent on which part of the couch top beams were passing through. Substantial improvements were also noted for static fields both calculated with the TPS and delivered physically when the couch models were included in the calculation. A statistically significant increase in agreement was noted for dose difference, distance to agreement, and γ-analysis with the Delta{sup 4} on VMAT and SBRT plans. A credentialing review showed improvement in treatment delivery after couch modeling with both thermoluminescent dosimeter doses and film analysis. Furthermore, analysis of treatment plans with and without using the couch model showed a statistically significant reduction in planning target volume coverage and increase in skin dose. In conclusion, ignoring the treatment couch, a common practice when generating a patient treatment plan, can overestimate the dose delivered especially for arc therapy. This work shows that explicitly modeling the couch during planning can meaningfully improve the agreement between calculated and measured dose distributions. Because of this project, we have implemented the couch models clinically across all treatment plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Siting landfills and incinerators in areas of historic unpopularity: Surveying the views of the next generation

Highlights: • Opinions and knowledge of young people in Italy about waste were studied. • Historic opposition to construction of waste facilities is difficult to overcome. • Awareness of waste management develops with knowledge of environmental issues. • Many stakeholders’ views are needed when siting a new waste management facility. • Respondents’ opinions were influenced by their level of environmental knowledge. - Abstract: The Campania Region in Southern Italy has suffered many problems with municipal solid waste management since the mid-1990s, leading to significant public disturbances and subsequent media coverage. This paper reports on the current views and knowledge of young people (university students) in this region about waste management operations and facilities, specifically the siting of landfills and incinerators. By means of a structured questionnaire, opinion and knowledge were systematically examined by degree type and course year. The study took place in 2011 at the University of Salerno campus. A sample of 900 students, comprising 100 students for each of the nine considered faculties, and 20 students for every academic course year, was randomly selected. Only about a quarter of respondents were not opposed to the siting of a landfill or an incinerator in their city. This clearly highlights that historic opposition to the construction of waste facilities is difficult to overcome and that distrust for previous poor management or indiscretions is long-lived and transcends generations. Students from technical faculties expressed the most reasonable opinion; opinion and knowledge were statistically related (Chi-square test, p < 0.05) to the attended faculty, and the knowledge grew linearly with progression through the university. This suggests that awareness of waste management practices develops with experience and understanding of environmental issues. There is general acceptance that many stakeholders – technicians, politicians and citizens – all have to be part of the decision process when siting a new waste management facility. The opinions of the young respondents were significantly influenced by their level of environmental knowledge.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Understanding the bias introduced in quantum dot blinking using change point analysis

Quantum dots are semiconductor crystals that are less than 100 nanometers in size; that is, between 1 billionth and 100 billionths of a meter. They can be composed of one semiconductor material or a core of one semiconductor surrounded by a shell of another. The quantum dots studied in this work consisted of a cadmium selenide core surrounded by a cadmium sulfide shell. When a quantum dot is illuminated with light, some of it can be absorbed and excites the quantum dot to a higher energy state. To relax back down to its resting state, light can be emitted in the form of fluorescence. The nature of the fluorescence that is emitted from a single quantum dot differs from that which is emitted from a bulk sample (usually a solid film or a solution of quantum dots). While in bulk samples the fluorescence over time fluctuates randomly about some average, maintaining a continuous average intensity, single quantum dot fluorescence switches between two or more intensities. This phenomenon is referred to as quantum dot blinking, and its origin is of significant relevance to solar cell, light emitting diode and biological tracking applications. Quantum dot blinking can be studied by exciting an isolated quantum dot with light and recording the ensuing fluorescence using sensitive detectors. This is done over many minutes, resulting in a fluorescence intensity (in counts per second) versus time trajectory. These trajectories must be further analyzed in order to understand the nature of the blinking behavior. Conventionally, a bin and threshold analysis is used, whereby the arrival times of fluorescent photons are binned to reduce the signal noise, and a threshold is used to separate the trajectory into periods of high and low fluorescence. In this study, the effects of bin size and threshold on the blinking kinetics were investigated, and the assumption that there is only one bright and one dark state was tested. To do so, a statistically rigorous method called change point analysis was needed which does not require binning and which can determine the number of intensity levels present. Blinking in 17 quantum dots was studied using both analysis methods. The primary parameter that was compared between the two methods is called a truncation time. Increasing the bin size was found to generally lead to a larger truncation time while increasing the threshold always decreased the truncation time. Using the change point analysis method, 12 out of 17 quantum dots were found to exhibit more than two intensity levels. Lastly, the assumption that only two intensity levels exist was found to significantly affect the blinking statistics: when individual levels were combined into one bright level, the truncation time would increase. The change point analysis method was found to be more suitable for studying multilevel blinking in quantum dots than the conventional bin and threshold method, since the effects of binning and thresholding can be alleviated and the two-level assumption relaxed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solar influence on winter severity in central Europe

The last two winters in central Europe were unusually cold in comparison to the years before. Meteorological data, mainly from the last 50 years, and modelling studies have suggested that both solar activity and El Niño strength may influence such central European winter coldness. To investigate the mechanisms behind this in a statistically robust way and to test which of the two factors was more important during the last 230 years back into the Little Ice Age, we use historical reports of freezing of the river Rhine. The historical data show that 10 of the 14 freeze years occurred close to sunspot minima and only one during a year of moderate El Niño. This solar influence is underpinned by corresponding atmospheric circulation anomalies in reanalysis data covering the period 1871 to 2008. Furthermore, weak solar activity is empirically related to extremely cold winter conditions in Europe also on such long time scales. This relationship still holds today, however the average winter temperatures have been rising during the last decades.

54 ENVIRONMENTAL SCIENCES↗

ON THE CONNECTION OF THE APPARENT PROPER MOTION AND THE VLBI STRUCTURE OF COMPACT RADIO SOURCES

Many of the compact extragalactic radio sources that are used as fiducial points to define the celestial reference frame are known to have proper motions detectable with long-term geodetic/astrometric very long baseline interferometry (VLBI) measurements. These changes can be as high as several hundred microarcseconds per year for certain objects. When imaged with VLBI at milliarcsecond (mas) angular resolution, these sources (radio-loud active galactic nuclei) typically show structures dominated by a compact, often unresolved 'core' and a one-sided 'jet'. The positional instability of compact radio sources is believed to be connected with changes in their brightness distribution structure. For the first time, we test this assumption in a statistical sense on a large sample rather than on only individual objects. We investigate a sample of 62 radio sources for which reliable long-term time series of astrometric positions as well as detailed 8 GHz VLBI brightness distribution models are available. We compare the characteristic direction of their extended jet structure and the direction of their apparent proper motion. We present our data and analysis method, and conclude that there is indeed a correlation between the two characteristic directions. However, there are cases where the {approx}1-10 mas scale VLBI jet directions are significantly misaligned with respect to the apparent proper motion direction.

79 ASTRONOMY AND ASTROPHYSICS↗

REGULARITY OF THE NORTH–SOUTH ASYMMETRY OF SOLAR ACTIVITY: REVISITED

Extended time series of Solar Activity Indices (ESAI) extended the Greenwich series of sunspot area from the year 1874 back to 1821. The ESAI's yearly sunspot area in the northern and southern hemispheres from 1821 to 2013 is utilized to investigate characteristics of the north–south hemispherical asymmetry of sunspot activity. Periodical behavior of about 12 solar cycles is also confirmed from the ESAI data set to exist in dominant hemispheres, linear regression lines of yearly asymmetry values, and cumulative counts of yearly sunspot areas in the hemispheres for solar cycles. The period is also inferred to appear in both the cumulative difference in the yearly sunspot areas in the hemispheres over the entire time interval and in its statistical Student's t-test. The hemispherical bias of sunspot activity should be regarded as an impossible stochastic phenomenon over a long time period.

79 ASTRONOMY AND ASTROPHYSICS↗

DIRECT MEASUREMENT OF THE ANGULAR POWER SPECTRUM OF COSMIC MICROWAVE BACKGROUND TEMPERATURE ANISOTROPIES IN THE WMAP DATA

The angular power spectrum of the cosmic microwave background temperature anisotropies is one of the most important characteristics in cosmology that can shed light on the properties of the universe such as its geometry and total density. Using flat sky approximation and Fourier analysis, we estimate the angular power spectrum from an ensemble of the least foreground-contaminated square patches from the Wilkinson Microwave Anisotropy Probe W and V frequency band map. This method circumvents the issue of foreground cleaning and that of breaking orthogonality in spherical harmonic analysis because we are able to mask out the bright Galactic plane region, thereby rendering a direct measurement of the angular power spectrum. We test and confirm the Gaussian statistical characteristic of the selected patches, from which the first and second acoustic peaks of the power spectrum are reproduced, and the third peak is clearly visible, albeit with some noise residual at the tail.

79 ASTRONOMY AND ASTROPHYSICS↗

A DETECTION OF H{alpha} IN AN EXOPLANETARY EXOSPHERE

We report on a search for H{alpha} absorption in four exoplanets. Strong features at H{alpha} are observed in the transmission spectra of both HD 189733b and HD 209458b. We attempt to characterize and remove the effects of stellar variability in HD 189733b, and along with an empirical Monte Carlo test the results imply a statistically significant transit-dependent feature of (- 8.72 {+-} 1.48) Multiplication-Sign 10{sup -4} integrated over a 16 A band relative to the adjacent continuum. We interpret this as the first detection of this line in an exoplanetary atmosphere. A previous detection of Ly{alpha} in HD 189733b's atmosphere allows us to calculate an excitation temperature for hydrogen, T{sub exc} = 2.6 Multiplication-Sign 10{sup 4} K. This calculation depends significantly on certain simplifying assumptions. We explore these assumptions and argue that T{sub exc} is very likely much greater than the radiative equilibrium temperature (the temperature the planet is assumed to be at based on stellar radiation and the planetary distance) of HD 189733b. A large T{sub exc} implies a very low density that is not in thermodynamic equilibrium with the planet's lower atmosphere. We argue that the n = 2 hydrogen required to cause H{alpha} absorption in the atmosphere is created as a result of the greater UV flux at HD 189733b, which has the smallest orbit and most chromospherically active central star in our sample. Though the overall integration of HD 209458b's transmission spectrum over a wide band is consistent with zero, it contains a dramatic, statistically significant feature in the transmission spectrum with reflectional symmetry. We discuss possible physical processes that could cause this feature. Our remaining two targets (HD 147506b and HD 149026b) do not show any clear features, so we place upper limits on their H{alpha} absorption levels.

79 ASTRONOMY AND ASTROPHYSICS↗