Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Forearm blood flow during body temperature transients produced by leg exercise

Subjects exercised for 30 min on a bicycle ergometer at 30, 50, and 70% of maximal aerobic power in ambient temperatures of 15, 25, and 35 C and vapor pressures of less than 18 torr. Exercise was used to vary internal temperature during an experiment, and different ambient temperatures were used to vary skin temperatures independently of internal temperature. Forearm skin temperature was fixed at about 36.5 C. Esophageal temperature was measured with a thermocouple at the level of the left atrium, and mean skin temperature was calculated from a weighted mean of thermocouple temperatures at eight skin sites. Forearm blood flow was measured by electrocapacitance plethysmography. Data are well accounted for by a linear equation independent of exercise intensity, although some subjects showed an equivocal vasodilator effect of exercise.

Wenger, C. B.↗

A comparison between Nimbus 5 THIR and ITPR temperatures and derived winds with rawinsonde data obtained in the AVE 2 experiment

During the period of May 11 and 12, 1974, NASA conducted its second Atmospheric Variability Experiment (AVE II) over the eastern United States. In this time interval, two Nimbus 5 orbits crossed the AVE II area, providing a series of ITPR soundings as well as THIR data. Horizontal temperature mapping of the AVE II cloud field is examined using two grid print map scales. Implied cloud top heights are compared with maximum radar-echo top reports. In addition, shelter temperatures in areas of clear sky are compared with the surface temperatures as determined from 11.5 micrometer radiometer data of the THIR experiment. The ITPR sounding accuracy is evaluated using interpolated radiosonde temperatures at times nearly coincident with the ITPR soundings. It was found that mean differences between the two data sets were as small as 1.3 C near 500 mb and as large as 2.9 C near the tropopause. The differences between ITPR and radiosonde temperatures at constant pressure levels were sufficient to induce significant differences in the horizontal temperature gradient. Cross sections of geostrophic wind along the orbital tracks were developed using a thermal wind buildup based on the ITPR temperature data and the radiosonde temperature data. Differences between the radiosonde and ITPR geostrophic winds could be explained on the basis of differences in the ITPR and radiosonde temperature gradients.

Arnold, J. E.↗

Effect of ambient temperature on the thermal profile of the human forearm, hand, and fingers

Forearm, hand, and finger skin temperatures were measured on the right and left sides of seven resting men. The purpose was to determine the bilateral symmetry of these segmental temperature profiles at ambient temperatures from 10 to 45 C. Thermistors placed on the right and left forearms, hands, and index fingers were used to monitor the subjects until equilibration was reached at each ambient temperature. Additionally, thermal profiles of both hands were measured with copper-constantan thermocouples. During one experimental condition (23 C ambient), rectal, ear canal, and 24 skin temperatures were measured on each subject. Average body and average skin temperatures are given for each subject at the 23 C ambient condition. Detailed thermal profiles are also presented for the dorsal, ventral, and circumferential left forearm, hand, and finger skin temperatures at 23 C ambient. No significant differences were found between the mean skin temperatures of the right and left contralateral segments at any of the selected ambient temperatures.

Montgomery, L. D.↗

Study of VTOL in ground-effect flow field including temperature effect

Detailed pressure, temperature, and velocity data were obtained for twin-fan configurations in-ground-effect and flow models to aid in predicting pressures and upwash forces on aircraft surfaces were developed. For the basic experiments, 49.5 mm-diameter jets were used, oriented normal to a simulated round plane, with pressurized, heated air providing a jet. The experimental data consisted of: (1) the effect of jet height and temperature on the ground, model, and upwash pressures, and temperatures, (2) the effect of simulated aircraft surfaces on the isolated flow field, (3) the jet-induced forces on a three-dimensional body with various strakes, (4) the effects of non-uniform coannular jets. For the uniform circular jets, temperature was varied from room temperature (24 C) to 232 C. Jet total pressure was varied between 9,300 Pascals and 31,500 Pascals. For the coannular jets, intended to represent turbofan engines, fan temperature was maintained at room temperature while core temperature was varied from room temperature to 437 C. Results are presented.

Hill, W. G.↗

Preliminary tests of an advanced high-temperature combustion system

A combustion system has been developed to operate efficiently and with good durability at inlet pressures to 4.05 MPa (40 atm), inlet air temperatures to 900 K, and exhaust gas temperatures to 2480 K. A preliminary investigation of this system was conducted at inlet pressures to 0.94 MPa (9 atm), a nominal inlet air temperature of 560 K, and exhaust gas temperatures to 2135 K. A maximum combustion efficiency of 98.5 percent was attained at a fuel-air ratio of 0.033; the combustion efficiency decreased to about 90 percent as the fuel-air ratio was increased to 0.058. An average liner metal temperature of 915 K, 355 kelvins greater than the nominal inlet air temperature, was reached with an average exhaust gas temperature of 2090 K. The maximum local metal temperature at this condition was about 565 kelvins above the nominal inlet air temperature and decreased to 505 kelvins above with increasing combustor pressure. Tests to determine the isothermal total pressure loss of the combustor showed a liner loss of 1.1 percent and a system loss of 6.5 percent.

Wear, J. D.↗

Evolution of electron and proton temperatures in a flaring loop. I - A case of thermal heating of electrons

A temperature difference between electrons and protons produced in a flaring loop was investigated experimentally by adopting a one-fluid, two-temperature model instead of a single-temperature model. Consideration was given to the case in which flare energy is released in the form of heating of electrons located in the top part of the loop. In this case, a large temperature difference appears in the corona in the energy-input phase of the flare. When the material evaporated from the chromosphere fills the corona, the temperature difference in the loop begins to shrink rapidly from below. Eventually, in the loop apex, the proton temperature exceeds the electron temperature mainly due to cooling of the electrons by conduction down the loop and heating of the protons by compression of the ascending material. In the late phase of the flare (about 15 min from the flare onset), the temperature difference becomes less than 2 pct of the mean temperature of electrons and protons at every point in the loop.

Nagai, F.↗

Temperature dependence of elastic and strength properties of T300/5208 graphite-epoxy

Experimental results are presented for the elastic and strength properties of T300/5208 graphite-epoxy at room temperature, 116K (-250 F), and 394K (+250 F). Results are presented for unidirectional 0, 90, and 45 degree laminates, and + or - 30, + or - 45, and + or - 60 degree angle-ply laminates. The stress-strain behavior of the 0 and 90 degree laminates is essentially linear for all three temperatures and that the stress-strain behavior of all other laminates is linear at 116K. A second-order curve provides the best fit for the temperature is linear at 116K. A second-order curve provides the best fit for the temperature dependence of the elastic modulus of all laminates and for the principal shear modulus. Poisson's ratio appears to vary linearly with temperature. all moduli decrease with increasing temperature except for E (sub 1) which exhibits a small increase. The strength temperature dependence is also quadratic for all laminates except the 0 degree - laminate which exhibits linear temperature dependence. In many cases the temperature dependence of properties is nearly linear.

Milkovich, S. M.↗

Measurement and correlation of jet fuel viscosities at low temperatures

Apparatus and procedures were developed to measure jet fuel viscosity for eight current and future jet fuels at temperatures from ambient to near -60 C by shear viscometry. Viscosity data showed good reproducibility even at temperatures a few degrees below the measured freezing point. The viscosity-temperature relationship could be correlated by two linear segments when plotted as a standard log-log type representation (ASTM D 341). At high temperatures, the viscosity-temperature slope is low. At low temperatures, where wax precipitation is significant, the slope is higher. The breakpoint between temperature regions is the filter flow temperature, a fuel characteristic approximated by the freezing point. A generalization of the representation for the eight experimental fuels provided a predictive correlation for low-temperature viscosity, considered sufficiently accurate for many design or performance calculations.

Schruben, D. L.↗

Soil temperature extrema recovery rates after precipitation cooling

From a one dimensional view of temperature alone variations at the Earth's surface manifest themselves in two cyclic patterns of diurnal and annual periods, due principally to the effects of diurnal and seasonal changes in solar heating as well as gains and losses of available moisture. Beside these two well known cyclic patterns, a third cycle has been identified which occurs in values of diurnal maxima and minima soil temperature extrema at 10 cm depth usually over a mesoscale period of roughly 3 to 14 days. This mesoscale period cycle starts with precipitation cooling of soil and is followed by a power curve temperature recovery. The temperature recovery clearly depends on solar heating of the soil with an increased soil moisture content from precipitation combined with evaporation cooling at soil temperatures lowered by precipitation cooling, but is quite regular and universal for vastly different geographical locations, and soil types and structures. The regularity of the power curve recovery allows a predictive model approach over the recovery period. Multivariable linear regression models alloy predictions of both the power of the temperature recovery curve as well as the total temperature recovery amplitude of the mesoscale temperature recovery, from data available one day after the temperature recovery begins.

Welker, J. E.↗

October Antarctic temperature and total ozone trends from 1979-1985

The morphology of temperature trends in the south polar stratosphere from 1979-1985 is detailed. A significant cooling has occurred in the stratosphere over this period. South polar October mean temperatures have declined 18 K at 24 km over the seven-year period. A large fraction of this decline occurs as a result of including 1979 temperatures in the trend. The years 1979 and 1982 differ from other years in that they include large mid-October wave events which produce significantly warmer polar temperatures. Nevertheless, a significant temperature decline has still occurred in the stratosphere even when the dynamically active years are not included. Comparing two relatively dynamically quiet years, 1980 and 1985, the largest temperature decrease in the 30 mb temperature field occurs not at the pole but in the subpolar temperature maximum centered near 60 deg S. The changes in temperature of both the maximum and the polar low regions correlate fairly well with total ozone changes observed by the Total Ozone Mapping Spectrophotometer.

Newman, Paul A.↗

The temperature of solar flares determined from X-ray spectral line ratios

The effect on derived solar flare plasma temperatures of (1) a power-law distribution of emission measure as a function of temperature, (2) a high-temperature isothermal source coupled to a low-temperature power-law distribution of emission measure, and (3) two isothermal sources is calculated for line ratios involving the ions S XV, Ca XIX, Ca XX, Fe XXV, Ni XXVII, and Fe XXVI. It is shown that if the Fe XXV temperature is less than about 25 million K, as is true for the majority of flares, then about 75 percent or more of the emission measure is produced by plasma at temperatures equal to or less than the Fe XXV temperature plus about 3 million K. If the Fe XXV temperature is 20 million K or higher, this percentage can be larger. This result is obtained even if a superhot component exists that extends up to several hundred million degrees. Temperatures determined from Fe XXVI demonstrate the presence of a superhot component.

Doschek, G. A.↗

A method for remote sensing the emissivity, fractional cloud cover and cloud top temperature of high-level, thin clouds

A methodology for retrieving the emissivity, cloud cover and cloud top temperature of high-level, thin clouds is developed and described. In the thermal infrared windows, the outgoing radiances from the earth's atmosphere contain information about cloud emissivity and cloud top temperature. This information is clearly demonstrated in the brightness temperature difference curves of two window channels. For the purpose of illustration, two window channels centered at 810 and 930 cm are chosen to construct the brightness temperature difference curves for a range of cloud top temperatures. These curves vary for different cloud top temperatures, and along each of these curves the emissivity changes. The brightness temperature difference method is used in a simulation study to demonstrate the feasibility of retrieving the cloud top temperature and emissivity by the utilization of measurements in two window channels. As expected, a perfect retrieval is found if perfect measurements and ideal atmospheric conditions are assumed. If a random error, which has a normal distribution with a mean of zero and standard deviation of + or - 0.5 C, is imposed to the measurements, a reasonable retrieval is found for emissivity greater than 0.3. The algorithm has been applied to a limited amount of HIRS2 data, which has 3.7, 3.98 and 11 micron channels. The cloud top temperature, emissivity and cloud cover are determined by using these channels.

Wu, Man-Li C.↗

Temperature characteristics of silicon space solar cells and underlying parameters

Silicon space cells, 2 cm x 2 cm, with 10 ohm-cm p-base resistivity, 8-mil base thickness, and no back-surface fields have been investigated over the temperature range from 301 to 223 K by measurements of dark forward and reverse current-voltage characteristics and current-voltage relations under illumination. From dark forward bias data, the first and second diode saturation currents, I01 and I02, are determined and hence the base diffusion length and lifetime of minority carriers as functions of temperature. Lifetime increases exponentially with temperature and is explained by a Shockley-Read-Hall model with deep recombination levels 0.245 eV above the valence band. The I02 variation with temperature follows the Sah-Noyce-Shockley-Choo model except at low temperature where extra transitions raise the value above the predicted level. Reverse bias current at low voltage is a thermally assisted tunneling process via deep levels which are observed in base recombination at higher temperatures. The tunneling effects tend to become independent of temperature in the low-temperature region. These results demonstrate the ability to deduce basic parameters such as lifetime from simple measurements and show that back-surface fields offer no advantage at temperatures below 230 K. The analysis also explains the fall in lifetimes observed as the base conductivity increases, attributing it to native defects (perhaps carbon-oxygen-vacancy complexes) rather than the concentration of base dopant.

Anspaugh, B. E.↗

Solar activity variation of ionospheric plasma temperatures

The present status of understanding and modeling of the variation of electron and ion temperatures with solar activity is reviewed. All atmospheric and ionospheric densities and temperatures are positively correlated with solar activity except the electron temperature, which exhibits a rather complex variation pattern during a solar cycle. The ion temperature at low altitudes closely follows the variation patterns of the neutral temperature. The electron temperature at high altitudes increases with increasing solar activity; the increase is larger during day than during night and exhibits a latitudinal variation. At low altitudes during daytime, tha amplitude of the seasonal variation of the electron temperature increases toward the solar maximum. At 400 km during daytime, the summer electron temperatures for Millstone Hill increase slightly toward higher solar activities, whereas the winter temperatures decrease distinctly. For Arecibo, an opposite trend is noticeable.

Bilitza, D.↗

Evidence for a high temperature differentiation in a molten earth: A preliminary appraisal

If the earth were molten during its later stages of accretion as indicated by the present understanding of planetary accretion process, the differentiation that led to the formation of the core and mantle must have occurred at high temperatures in the range of 3000-5000 K because of the effect of pressure on the temperature of melting in the interior of the earth. This calls into question the use of low-temperature laboratory measurements of partition coefficients of trace elements to make inferences about earth accretion and differentiation. The low temperature partition coefficients cannot be directly applied to high temperature fractionations because partition coefficients refer to an equilibrium specific to a temperature for a given reaction, and must change in some proportion to exp 1/RT. There are no laboratory data on partition coefficients at the high temperatures relevant to differentiation in the interior of the earth, and an attempt to estimate high temperature distribution coefficients of siderophile elements was made by considering the chemical potential of a given element at equilibrium and how this potential changes with temperature, under some specific assumptions.

Murthy, V. Rama↗

Improving the low temperature ductility of NiAl

The intermetallic NiAl exhibits excellent potential as a structural material for application in air-breathing and single-stage-to-orbit engines. Unfortunately NiAl is brittle at ambient temperature, which is partly attributed to the lack of five independent slip systems as required by von Mises criterion for uniform, volume conserving deformation since the operative group of zone axes (100) slip offers only three independent slip systems. Isostructural FeAl, however, deforms by group of zone axes (111) slip at room temperature which provides five independent slip systems. Thus, it was decided to macroalloy NiAl with Fe to promote group of zone axes (111) slip thereby possibly improving the ductility. For Ni - 30 at. (percent) Al - 20 at. (percent) Fe having essentially bcc microstructure indicated up to 6 percent tensile elongation combined with high yield strength (about 800 MPa). The results compare favorably with those of stoichiometric Ni - 50 at. (percent) Al which, however, deforms by group of zone axes (100) slip at room temperature. The multi-phase alloy approach has proven even more successful for Ni - 20 at. (percent) Al - 30 at. (percent) Fe. The high temperature ductility of the multi-phase alloy was attributed to deformation transfer across interphase boundaries and the crack stopping action of the constituent gamma/gamma' phase. While the constituent phase became increasingly brittle, the beta' phase became more ductile at elevated temperatures. Thus the multi-phase alloy did not exhibit any elevated temperature embrittlement. Similarly, while the beta' phase became weak at high temperatures, the gamma/gamma' phase exhibited better strength retention leading to the improved elevated temperature strength of the multi-phase alloy. Thus, the multi-phase alloy benefits from both its constituent phases, with each phase alleviating the disadvantages associated with the other phase over any temperature range. The multi-phase alloy approach is suggested as a possible approach to designing intermetallic-based alloys.

Guha, Sumit↗

On the assumption of vanishing temperature fluctuations at the wall for heat transfer modeling

Boundary conditions for fluctuating wall temperature are required for near-wall heat transfer modeling. However, their correct specifications for arbitrary thermal boundary conditions are not clear. The conventional approach is to assume zero fluctuating wall temperature or zero gradient for the temperature variance at the wall. These are idealized specifications and the latter condition could lead to an ill posed problem for fully-developed pipe and channel flows. In this paper, the validity and extent of the zero fluctuating wall temperature condition for heat transfer calculations is examined. The approach taken is to assume a Taylor expansion in the wall normal coordinate for the fluctuating temperature that is general enough to account for both zero and non-zero value at the wall. Turbulent conductivity is calculated from the temperature variance and its dissipation rate. Heat transfer calculations assuming both zero and non-zero fluctuating wall temperature reveal that the zero fluctuating wall temperature assumption is in general valid. The effects of non-zero fluctuating wall temperature are limited only to a very small region near the wall.

Sommer, T. P.↗

An algorithm for the estimation of bounds on the emissivity and temperatures from thermal multispectral airborne remotely sensed data

The effective flux incident upon the detectors of a thermal sensor, after it has been corrected for atmospheric effects, is a function of a non-linear combination of the emissivity of the target for that channel and the temperature of the target. The sensor system cannot separate the contribution from the emissivity and the temperature that constitute the flux value. A method that estimates the bounds on these temperatures and emissivities from thermal data is described. This method is then tested with remotely sensed data obtained from NASA's Thermal Infrared Multispectral Scanner (TIMS) - a 6 channel thermal sensor. Since this is an under-determined set of equations i.e. there are 7 unknowns (6 emissivities and 1 temperature) and 6 equations (corresponding to the 6 channel fluxes), there exist theoretically an infinite combination of values of emissivities and temperature that can satisfy these equations. Using some realistic bounds on the emissivities, bounds on the temperature are calculated. These bounds on the temperature are refined to estimate a tighter bound on the emissivity of the source. An error analysis is also carried out to quantitatively determine the extent of uncertainty introduced in the estimate of these parameters. This method is useful only when a realistic set of bounds can be obtained for the emissivities of the data. In the case of water the lower and upper bounds were set at 0.97 and 1.00 respectively. Five flights were flown in succession at altitudes of 2 km (low), 6 km (mid), 12 km (high), and then back again at 6 km and 2 km. The area selected with the Ross Barnett reservoir near Jackson, Mississippi. The mission was flown during the predawn hours of 1 Feb. 1992. Radiosonde data was collected for that duration to profile the characteristics of the atmosphere. Ground truth temperatures using thermometers and radiometers were also obtained over an area of the reservoir. The results of two independent runs of the radiometer data averaged 7.03 plus or minus .70 for the first run and 7.31 plus or minus .88 for the second run. The results of the algorithm yield a temperature of 7.68 for the low altitude data to 8.73 for the high altitude data.

Jaggi, S.↗