Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “systematic errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Measuring the muon precession frequency in the E989 Fermilab g-2 experiment

Since more than 50 years the electron and muon anomalies, $a_e$ and $a_\mu$, defined in terms of the gyromagnetic factor $g_i$ for particle $i$ as $a_i=(g_i-2)/2$, have provided a deep insight into the quantum structure of elementary particles.They have been, and continue to be, a milestone for the development of the Standard Model of Particle Physics against which all new theories have to be compared.For almost 20 years, the experimental value of $a_\mu$ has shown a tantalizing discrepancy of more than $3 \sigma$ from the theoretical prediction making it mandatory for experimentalists to improve the current result, dominated by the E821 experiment at BNL\cite{BNL}. The Muon $g-2$ E989 experiment at Fermilab will use the same storage ring technique used at BNL, and previously in the CERN-III experiment, with the goal of decreasing by a factor of 4 the current error on $a_\mu$, which will allow for a finer comparison with the theoretical prediction. E989 started collecting data in winter 2018 accumulating, in the period April-July 2018 (Run1) almost twice the statistics of the previous experiment (before application of data quality cuts). In this document, the experiment will be briefly described, underlying the improvements which will allow to reduce the systematic error, and some preliminary result will be shown.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of Daily Setup Variation With Tomotherapy Megavoltage Computed Tomography

The purpose of this study was to evaluate different setup uncertainties for various anatomic sites with TomoTherapy (registered) pretreatment megavoltage computed tomography (MVCT) and to provide optimal margin guidelines for these anatomic sites. Ninety-two patients with tumors in head and neck (HN), brain, lung, abdominal, or prostate regions were included in the study. MVCT was used to verify patient position and tumor target localization before each treatment. With the anatomy registration tool, MVCT provided real-time tumor shift coordinates relative to the positions where the simulation CT was performed. Thermoplastic facemasks were used for HN and brain treatments. Vac-Lok{sup TM} cushions were used to immobilize the lower extremities up to the thighs for prostate patients. No respiration suppression was administered for lung and abdomen patients. The interfractional setup variations were recorded and corrected before treatment. The mean interfractional setup error was the smallest for HN among the 5 sites analyzed. The average 3D displacement in lateral, longitudinal, and vertical directions for the 5 sites ranged from 2.2-7.7 mm for HN and lung, respectively. The largest movement in the lung was 2.0 cm in the longitudinal direction, with a mean error of 6.0 mm and standard deviation of 4.8 mm. The mean interfractional rotation variation was small and ranged from 0.2-0.5 deg., with the standard deviation ranging from 0.7-0.9 deg. Internal organ displacement was also investigated with a posttreatment MVCT scan for HN, lung, abdomen, and prostate patients. The maximum 3D intrafractional displacement across all sites was less than 4.5 mm. The interfractional systematic errors and random errors were analyzed and the suggested margins for HN, brain, prostate, abdomen, and lung in the lateral, longitudinal, and vertical directions were between 4.2 and 8.2 mm, 5.0 mm and 12.0 mm, and 1.5 mm and 6.8 mm, respectively. We suggest that TomoTherapy (registered) pretreatment MVCT can be used to improve the accuracy of patient positioning and reduce tumor margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sterile neutrino oscillations in MINOS and hadron production in pC collisions

MINOS is a long baseline neutrino oscillation experiment, starting with a muon-neutrino beam, for the precise measurement of the atmospheric neutrino oscillation parameters |Δm 2 | and θ 23 . The Near Detector measures the neutrino flux and spectra before oscillations. The beam propagates for 735 km to the Far Detector, which measures the depleted spectrum after oscillations. The depletion can be interpreted as v μ → v τ oscillations. Subdominant v μ → v e oscillations may be allowed if the mixing angle θ 13 ≠ 0. The two detectors are functionally identical in order to cancel systematic errors when using the Near Detector data to constrain the Far Detector prediction. A crucial part of the analysis is the relative calibration between the two detectors, which is known at the 2% level. A calibration procedure to remove the time and temperature dependence of the detector response using through-going cosmic muons is presented here. Although the two-detector approach reduces the systematic uncertainties related to the neutrino flux, a cross check on the neutrino parent meson ratios is performed in this thesis. The cross sections of mesons produced in proton-carbon interactions from the NA49 experiment have been measured and the results have been compared to the MINOS expectations. A neutrino oscillation analysis allowing mixing to a sterile neutrino is performed, under the assumption that the additional mass splitting is Ο(1 eV 2 ). The analysis uses the energy spectrum of the neutral current interaction products, as neutral current interactions are sensitive to sterile neutrino mixing but not to the active flavour neutrino mixing. The neutrino oscillation parameters have been found to be: |Δm 2 | = 2.43 -0.18 +0.21 x 10 -3 eV 2 , θ 23 = 40.27° -5.17 +14.64 , θ 24 = 0.00° +5.99 and θ 34 = 0.00° +24.57 under the assumption that θ 13 = 12° (limited by the CHOOZ experiment) or |Δm 2 | = 2.43 -0.18 +0.20 x 10 -3 eV 2 , θ 23 = 39.09° -4.89 +16.71 , θ 24 = 0.00° +4.79 and θ 34 = 0.00° +17.39 if θ 13 is assumed to be zero.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

GeoCarb L2 Validation- Albedo Error Propagation into XCO2 in the Near Infrared

GeoCarb validation activities Pre-launch validation •Thermovac: Nov-Jan, 2022/3: Edwards/Dryden will move to Palo Alto Nov-March 2022/3 •Day-in-the life simulation-2022 •Simulations near Dallas, TX •Validation of TROPOMI in GeoCarb domain-2022 2GeoCarb post-launch GeoCarb will have gas precision of: •0.3% (1.2 ppm) for XCO2 •0.6% (11 ppb) for XCH4 •10% or 12 ppb for XCO GeoCarb SIF with precision of better than 0.75 W/m2/um/sr GeoCarb will utilize TCCON, GML/DOE aircraft, AirCore, and any validation site with systematic errors better than GeoCarb’s

GeoCarb↗

Effects of model deficiencies on parameter estimation

Reliable structural dynamic models will be required as a basis for deriving the reduced-order plant models used in control systems for large space structures. Ground vibration testing and model verification will play an important role in the development of these models; however, fundamental differences between the space environment and earth environment, as well as variations in structural properties due to as-built conditions, will make on-orbit identification essential. The efficiency, and perhaps even the success, of on-orbit identification will depend on having a valid model of the structure. It is envisioned that the identification process will primarily involve parametric methods. Given a correct model, a variety of estimation algorithms may be used to estimate parameter values. This paper explores the effects of modeling errors and model deficiencies on parameter estimation by reviewing previous case histories. The effects depend at least to some extent on the estimation algorithm being used. Bayesian estimation was used in the case histories presented here. It is therefore conceivable that the behavior of an estimation algorithm might be useful in detecting and possibly even diagnosing deficiencies. In practice, the task is complicated by the presence of systematic errors in experimental procedures and data processing and in the use of the estimation procedures themselves.

Hasselman, T. K.↗

Impact of Systematic Modeling Uncertainties on Kilonova Property Estimation

The precise atomic structure and therefore the wavelength-dependent opacities of lanthanides are highly uncertain. This uncertainty introduces systematic errors in modeling transients like kilonovae and estimating key properties such as mass, characteristic velocity, and heavy metal content. Here, we quantify how atomic data from across the literature as well as choices of thermalization efficiency of r-process radioactive decay heating impact the light curve and spectra of kilonovae. Specifically, we analyze the spectra of a grid of models produced by the radiative transfer code Sedona that span the expected range of kilonova properties to identify regions with the highest systematic uncertainty. Our findings indicate that differences in atomic data have a substantial impact on estimates of lanthanide mass fraction, spanning approximately 1 order of magnitude for lanthanide-rich ejecta, and demonstrate the difficulty in precisely measuring the lanthanide fraction in lanthanide-poor ejecta. Mass estimates vary typically by 25%–40% for differing atomic data. Similarly, the choice of thermalization efficiency can affect mass estimates by 20%–50%. Observational properties such as color and decay rate are highly model dependent. Velocity estimation, when fitting solely based on the light curve, can have a typical error of ∼100%. Atomic data of light r-process elements can strongly affect blue emission. Even for well-observed events like GW170817, the total lanthanide production estimated using different atomic data sets can vary by a factor of ∼6.

Gravitational wave sources↗

Measuring the reduced shear

Neglecting the second order corrections in weak lensing measurements can lead to a few percent uncertainties on cosmic shears, and becomes more important for cluster lensing mass reconstructions. Existing methods which claim to measure the reduced shears are not necessarily accurate to the second order when a point spread function (PSF) is present. We show that the method of Zhang (2008) exactly measures the reduced shears at the second order level in the presence of PSF. A simple theorem is provided for further confirming our calculation, and for judging the accuracy of any shear measurement method at the second order based on its properties at the first order. The method of Zhang (2008) is well defined mathematically. It does not require assumptions on the morphologies of galaxies and the PSF. To reach a sub-percent level accuracy, the CCD pixel size is required to be not larger than 1/3 of the Full Width at Half Maximum (FWHM) of the PSF, regardless of whether the PSF has a power-law or exponential profile at large distances. Using a large ensemble (∼>10{sup 7}) of mock galaxies of unrestricted morphologies, we study the shear recovery accuracy under different noise conditions. We find that contaminations to the shear signals from the noise of background photons can be removed in a well defined way because they are not correlated with the source shapes. The residual shear measurement errors due to background noise are consistent with zero at the sub-percent level even when the amplitude of such noise reaches about 1/10 of the source flux within the half-light radius of the source. This limit can in principle be extended further with a larger galaxy ensemble in our simulations. On the other hand, the source Poisson noise remains to be a cause of systematic errors. For a sub-percent level accuracy, our method requires the amplitude of the source Poisson noise to be less than 1/80 ∼ 1/100 of the source flux within the half-light radius of the source, corresponding to collecting roughly 10{sup 4} source photons.

79 ASTRONOMY AND ASTROPHYSICS↗

NEAR-INFRARED THERMAL EMISSION DETECTIONS OF A NUMBER OF HOT JUPITERS AND THE SYSTEMATICS OF GROUND-BASED NEAR-INFRARED PHOTOMETRY

We present detections of the near-infrared thermal emission of three hot Jupiters and one brown dwarf using the Wide-field Infrared Camera (WIRCam) on the Canada-France-Hawaii Telescope (CFHT). These include Ks-band secondary eclipse detections of the hot Jupiters WASP-3b and Qatar-1b and the brown dwarf KELT-1b. We also report Y-band, K {sub CONT}-band, and two new and one reanalyzed Ks-band detections of the thermal emission of the hot Jupiter WASP-12b. We present a new reduction pipeline for CFHT/WIRCam data, which is optimized for high precision photometry. We also describe novel techniques for constraining systematic errors in ground-based near-infrared photometry, so as to return reliable secondary eclipse depths and uncertainties. We discuss the noise properties of our ground-based photometry for wavelengths spanning the near-infrared (the YJHK bands), for faint and bright stars, and for the same object on several occasions. For the hot Jupiters WASP-3b and WASP-12b we demonstrate the repeatability of our eclipse depth measurements in the Ks band; we therefore place stringent limits on the systematics of ground-based, near-infrared photometry, and also rule out violent weather changes in the deep, high pressure atmospheres of these two hot Jupiters at the epochs of our observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Accuracy of tip-sample interaction measurements using dynamic atomic force microscopy techniques: Dependence on oscillation amplitude, interaction strength, and tip-sample distance

Atomic force microscopy (AFM) is a versatile surface characterization method that can map a sample’s topography with high spatial resolution while simultaneously interrogating its surface chemistry through the site-specific high-resolution quantification of the forces acting between the sample and the probe tip. Thanks to considerable advances in AFM measurement technology, such local measurements of chemical properties have gained much popularity in recent years. To this end, dynamic AFM methodologies are implemented where either the oscillation frequency or the oscillation amplitude and phase of the vibrating cantilever are recorded as a function of tip-sample distance and subsequently converted to reflect tip-sample forces or interaction potentials. Such conversion has, however, been shown to produce non-negligible errors when applying the most commonly used mathematical conversion procedures if oscillation amplitudes are of the order of the decay length of the interaction. Extending on these earlier findings, the computational study presented in this paper reveals that the degree of divergence from actual values may also critically depend on both the overall strength of tip-sample interaction and the distance at which the interaction is obtained. These systematic errors can, however, be effectively eliminated by using oscillation amplitudes that are sufficiently larger than the decay length of the interaction potential.

Electrical properties and parameters↗

DESI DR2 results. I. Baryon acoustic oscillations from the Lyman alpha forest

We present the baryon acoustic oscillation (BAO) measurements with the Lyman-𝛼 (Ly⁢𝛼) forest from the second data release (DR2) of the Dark Energy Spectroscopic Instrument (DESI) survey. Our BAO measurements include both the autocorrelation of the Ly⁢𝛼 forest absorption observed in the spectra of high-redshift quasars and the cross-correlation of the absorption with the quasar positions. The total sample size is approximately a factor of 2 larger than the DR1 dataset, with forest measurements in over 820,000 quasar spectra and the positions of over 1.2 million quasars. We describe several significant improvements to our analysis in this paper, and two supporting papers describe improvements to the synthetic datasets that we use for validation and how we identify damped Ly⁢𝛼 absorbers. Our main result is that we have measured the BAO scale with a statistical precision of 1.1% along and 1.3% transverse to the line of sight, for a combined precision of 0.65% on the isotropic BAO scale at 𝑧 eff =2.33. This excellent precision, combined with recent theoretical studies of the BAO shift due to nonlinear growth, motivated us to include a systematic error term in Ly⁢𝛼 BAO analysis for the first time. We measure the ratios 𝐷 𝐻 ⁡(𝑧 eff )/𝑟 𝑑 = 8.632 ± 0.098 ± 0.026 and 𝐷 𝑀 ⁡(𝑧 eff )/𝑟 𝑑 = 38.99 ± 0.52 ± 0.12, where 𝐷 𝐻 = 𝑐/𝐻⁡(𝑧) is the Hubble distance, 𝐷 𝑀 is the transverse comoving distance, 𝑟 𝑑 is the sound horizon at the drag epoch, and we quote both the statistical and the theoretical systematic uncertainty. The companion paper presents the BAO measurements at lower redshifts from the same dataset and the cosmological interpretation.

baryon acoustic oscillations↗

DESI DR2 Results I: Baryon Acoustic Oscillations from the Lyman Alpha Forest

We present the Baryon Acoustic Oscillation (BAO) measurements with the Lyman-alpha (LyA) forest from the second data release (DR2) of the Dark Energy Spectroscopic Instrument (DESI) survey. Our BAO measurements include both the auto-correlation of the LyA forest absorption observed in the spectra of high-redshift quasars and the cross-correlation of the absorption with the quasar positions. The total sample size is approximately a factor of two larger than the DR1 dataset, with forest measurements in over 820,000 quasar spectra and the positions of over 1.2 million quasars. We describe several significant improvements to our analysis in this paper, and two supporting papers describe improvements to the synthetic datasets that we use for validation and how we identify damped LyA absorbers. Our main result is that we have measured the BAO scale with a statistical precision of 1.1% along and 1.3% transverse to the line of sight, for a combined precision of 0.65% on the isotropic BAO scale at $z_{eff} = 2.33$. This excellent precision, combined with recent theoretical studies of the BAO shift due to nonlinear growth, motivated us to include a systematic error term in LyA BAO analysis for the first time. We measure the ratios $D_H(z_{eff})/r_d = 8.632 \pm 0.098 \pm 0.026$ and $D_M(z_{eff})/r_d = 38.99 \pm 0.52 \pm 0.12$, where $D_H = c/H(z)$ is the Hubble distance, $D_M$ is the transverse comoving distance, $r_d$ is the sound horizon at the drag epoch, and we quote both the statistical and the theoretical systematic uncertainty. The companion paper presents the BAO measurements at lower redshifts from the same dataset and the cosmological interpretation.

79 ASTRONOMY AND ASTROPHYSICS↗

Media Calibration in the Deep Space Network: A Status Report

A new media calibration system (MCS) has been implemented at the Goldstone complex of the DSN (Deep Space Network). It is intended to calibrate the delay of radio signals imposed by the neutral atmosphere. The system provides periodic measurements of both the static dry and fluctuating wet components of this delay. In particular, the system will calibrate the fluctuations in line of sight path delay due to atmospheric water vapor that we believe will dominate the error budget for several radio science and radio astronomy experiments. We have compared two of these media calibration systems with a connected element interferometer on a 21 km baseline. In this report we describe a total of 30 observations in which a radio source was tracked for an hour or more and the delay residuals then calibrated using the MCS. The accuracy of the comparison appears to be limited by systematic errors in the interferometer, which are under investigation. However, our results do indicate that the MCS can meet or exceed the two-way Allan standard deviation specification of 1.5 x 10( exp -15) on time scales of 2,000 - 10,000 sec, as required by the Cassini GWE (Gravitational Wave Experiment) for two way Doppler tracking.

Naudet, Charles J.↗

Error trends in SASS winds as functions of atmospheric stability and sea surface temperature

Wind speed measurements obtained with the scatterometer instrument aboard the Seasat satellite are compared equivalent neutral wind measurements obtained from ship reports in the western N. Atlantic and eastern N. Pacific where the concentration of ship reports are high and the ranges of atmospheric stability and sea surface temperature are large. It is found that at low wind speeds the difference between satellite measurements and surface reports depends on sea surface temperature. At wind speeds higher than 8 m/s the dependence was greatly reduced. The removal of systematic errors due to fluctuations in atmospheric stability reduced the r.m.s. difference from 1.7 m/s to 0.8 m/s. It is suggested that further clarification of the effects of fluctuations in atmospheric stability on Seasat wind speed measurements should increase their reliability in the future.

Liu, W. T.↗

Competition between the tensor light shift and nonlinear Zeeman effect

Many precision measurements (e.g., in spectroscopy, atomic clocks, quantum-information processing, etc.) suffer from systematic errors introduced by the light shift. In our experimental configuration, however, the tensor light shift plays a positive role enabling the observation of spectral features otherwise masked by the cancellation of the transition amplitudes and creating resonances at a frequency unperturbed either by laser power or beam inhomogeneity. These phenomena occur thanks to the special relation between the nonlinear Zeeman and light shift effects. The interplay between these two perturbations is systematically studied and the cancellation of the nonlinear Zeeman effect by the tensor light shift is demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lattice QCD calculation of 𝑥-dependent meson distribution amplitudes at physical pion mass with threshold logarithm resummation

We present a lattice quantum chromodynamics (QCD) calculation of the 𝑥-dependent pion and kaon distribution amplitudes (DA) in the framework of large momentum effective theory. This calculation is performed on a fine lattice of 𝑎 = 0.076 fm at physical pion mass, with the pion boosted to 1.8 GeV and kaon boosted to 2.3 GeV. We renormalize the matrix elements in the hybrid scheme and match to Math output error with a subtraction of the leading renormalon in the Wilson-line mass. The perturbative matching is improved by resumming the large logarithms related to the small quark and gluon momenta in the soft-gluon limit. After resummation, we demonstrate that we are able to calculate a range of 𝑥 ∈[𝑥 0 ,1 − 𝑥 0 ] with 𝑥 0 = 0.25 for pion and 𝑥 0 = 0.2 for kaon with theoretical systematic errors under control. The kaon DA is shown to be slighted skewed, and narrower than pion DA. Although the 𝑥-dependence cannot be direct calculated beyond these ranges, we estimate higher moments of the pion and kaon DAs by complementing our calculation with short-distance factorization.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determining the metric of the Cosmos: Stability, accuracy, and consistency

The ultimate application of Einstein's field equations is to empirically determine the geometry of the Universe from its matter content, rather than simply assuming the Universe can be represented by a homogeneous model on all scales. Choosing a Lemaitre-Tolman-Bondi model as the most convenient inhomogeneous model for the early stages of development, a data reduction procedure was recently validated using perfect test data. Here, we simulate observational uncertainties and improve the previous numerical scheme to ensure that it will be usable with real data as soon as observational surveys are sufficiently deep and complete. Two regions require special treatment--the origin and the maximum in the areal radius. To minimize numerical errors near the origin, we use a Lemaitre-Tolman-Bondi series expansion to provide the initial values for integrating the differential equations. We also use an improved method to match the numerical integration to the series expansion that bridges the region near the maximum in the areal radius. Because the mass enclosed within the maximum obeys a specific relationship, we show that it is possible to correct for a fixed systematic error in either the distance scale or the redshift-space mass density, such that the integrated values are consistent with the data at the maximum.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental consistency in parton distribution fitting

The recently developed 'data set diagonalization' method is applied to measure compatibility of the data sets that are used to determine parton distribution functions. Discrepancies among the experiments are found to be somewhat larger than is predicted by propagating the published experimental errors according to Gaussian statistics. The results support a tolerance criterion of {Delta}{chi}{sup 2{approx_equal}}10 to estimate the 90% confidence range for parton distribution function uncertainties. No basis is found in the data sets for the larger {Delta}{chi}{sup 2} values that are in current use, though it may be necessary to retain those larger values until improved methods can be developed to take account of systematic errors in applying the theory, including the effect of parametrization dependence. The data set diagonalization method also measures how much influence each experiment has on the global fit and identifies experiments that show significant tension with respect to the others. The method is used to explore the contribution from muon scattering experiments, which are found to exhibit the largest discrepancies in the current fit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulated forecast error and climate drift resulting from the omission of the upper stratosphere in numerical models

Using an NCAR community climate model, Version I, the forecast error growth and the climate drift resulting from the omission of the upper stratosphere are investigated. In the experiment, the control simulation is a seasonal integration of a medium horizontal general circulation model with 30 levels extending from the surface to the upper mesosphere, while the main experiment uses an identical model, except that only the bottom 15 levels (below 10 mb) are retained. It is shown that both random and systematic errors develop rapidly in the lower stratosphere with some local propagation into the troposphere in the 10-30-day time range. The random growth rate in the troposphere in the case of the altered upper boundary was found to be slightly faster than that for the initial-condition uncertainty alone. However, this is not likely to make a significant impact in operational forecast models, because the initial-condition uncertainty is very large.

Boville, Byron A.↗