Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Online condition monitoring based dead-time compensation for high frequency SiC voltage source inverter

Dead-time, device output capacitance, and other non-ideal characteristics cause voltage error for the midpoint PWM voltage of the semiconductor phase-leg employed in a voltage-source inverter (VSI). Voltage-second balancing is a well-known concept to mitigate this distortion and improve converter power quality. This paper proposes a unique voltage-second balancing scheme for a SiC based voltage source inverter using online condition monitoring of turn-off delay time and drain-source voltage rise/fall time. This data is sent to the micro-controller to be used in an algorithm to actively adjust the duty cycle of the input PWM gate signals to match the voltage-second of the non-ideal output voltage with an ideal output voltage-second. The monitoring system also allows for this implementation to eliminate the need for precise current sensing and allows for the implementation to be load independent. Dynamic current sensing is still a developing technology, and each load has a unique effect on the output voltage distortion. Test results for a 1 kW half-bridge inverter implementing this monitoring system and voltage-second balancing scheme show a 70% enhancement on the error against the ideal fundamental current value of the output current and a 2% THD improvement on the output current low frequency harmonics.

Dyer, Jacob↗

AC Power Flow Based DLMP Calculation and Decomposition Method to Smooth Power Fluctuation of Distributed Renewable Energy Sources

As the penetration of renewable energy sources increases, the growing renewable power variability brings ramping issues to power systems. Meanwhile, the development of distributed energy resources (DERs) makes the distribution systems to provide both energy and ancillary services. To incentivise individual resources and customers to alleviate ramping issues on the demand side, a two-stage distribution locational marginal price (DLMP) calculation and decomposition method is developed to formulate the marginal power ramping price for DERs. In the first stage of the proposed method, a distribution system operator market scheduling model based on AC optimal power flow is designed to estimate the optimal operating point of the distribution system. Subsequently, the voltage and power flow constraints are linearised in stage two to calculate DLMP. Finally, based on the Lagrange function and sensitivity factors, DLMP is decomposed to the marginal costs for active/reactive power, voltage management, power loss and power variability. Case studies demonstrate that the proposed model can effectively smooth the power fluctuation and reduce the ramping flexibility requirements of distribution systems.

AC optimal power flow↗

Online Static Load Model Estimation in Distribution Systems: Preprint

The paper focuses on parameter identification for time varying voltage dependent polynomial load models, namely the constant impedance (Z), constant current (I), and constant power (P), in the distribution systems. Typically, parameter identification has been done for aggregated loads at substations for the transmission planning studies. Given the higher voltage volatility faced by active distribution systems, this paper takes the load model estimation to the distribution networks. The paper assumes the presence of measurements at the distribution nodes from various sources, each at varying temporal resolutions. Least squares estimation (LSE) method with bounded variables is used to convert the measurements into ZIP parameter estimations for loads at various locations of the feeder. The results and discussions focus on some of the estimation issues faced in a distribution system due to varying voltage sensitivities of loads along a feeder, measurement resolution, impact of window size and sampling rate of measurement data, and the use of dynamic simulations to create synthetic measurement data in the absence of real ones.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Preemptive Voltage Monitoring and Control Using Probabilistic Voltage Sensitivities

Increased penetration levels of distributed variable renewable generation can cause random voltage fluctuations and violations at multiple nodes. Traditional methods of voltage control typically involve reactionary responses of capacitor banks, tap changers, and recently even smart inverters. But because of the lack of foresight in voltage violations, these controls are ineffective to completely mitigate the issue. Therefore, new methods of predicting voltage violations subject to random power injection changes in the distribution network are needed, which can be used to guide optimal and dynamic methods of voltage control. This work lays the foundation for such preemptive voltage monitoring and control by proposing an analytical and sensor data-driven voltage sensitivity analysis method. Driven by stochastic data and forecasts, the method can be used to develop probabilistic voltage sensitivities and consequently to predict system nodes with high likelihood of voltage limit violations. The effectiveness of this method is tested on IEEE 69-node distribution system integrated with distributed solar. The results demonstrate the proposed method's ability to successfully predict nodes with high probability of voltage violations for a specific time-series simulation. The results also demonstrate the ability to guide timely power injection control actions to mitigate future voltage violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Preemptive Voltage Monitoring and Control Using Probabilistic Voltage Sensitivities: Preprint

Increased penetration of distributed variable re-newable generation may cause random voltage fluctuations and violations at multiple nodes. Traditional methods of voltage control typically involve reactionary responses of capacitor banks, tap changers, and recently even smart inverters. But due to the lack of foresight in voltage violations, these controls are ineffective to completely mitigate the issue. Therefore, new methods of predicting voltage violations subject to random power injection changes in the distribution network is needed, which can be used to guide optimal and dynamic methods of voltage control. This work lays the foundation for such preemptive voltage monitoring and control by proposing an analytical and sensor data-driven voltage sensitivity analysis method. Driven by stochastic data and forecasts, the method can be used to develop probabilistic voltage sensitivities and consequently to predict system nodes with high likelihood of voltage limit violations. The effectiveness of this method is tested on IEEE 69 node distribution system integrated with distributed solar. The results demonstrate the proposed method's ability to successfully predict nodes with high probability of voltage violations for a specific time series simulation. The results also demonstrate the ability to guide timely power injection control actions to mitigate future voltage violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental evaluation of a volts-per-hertz reference circuit for the isotope Brayton system

In Brayton-cycle power systems, the speed decreases rapidly with overload. If the voltage decreases linearly with speed (frequency), the power decreases as the square of the voltage. This makes the system more tolerant of overloads. A volts-per-hertz reference circuit, consisting of a volts-per-hertz sensor and a voltage limiter, was designed and fabricated. This reference circuit was incorporated in an existing voltage regulator to control a turbine-driven alternator. Test results show that the control does function to reduce voltage at speeds below the rated speed and that it performed successfully during transients.

Wimmer, H. L.↗

Active control of flexural vibrations in beams

The feasibility of using piezoelectric actuators to control the flexural oscillations of large structures in space is investigated. Flexural oscillations are excited by impulsive loads. The vibratory response can degrade the pointing accuracy of cameras and antennae, and can cause high stresses at structural node points. Piezoelectric actuators have the advantage of exerting localized bending moments. In this way, vibration is controlled without exciting rigid body modes. The actuators are used in collocated sensor/driver pairs to form a feedback control system. The sensor produces a voltage that is proportional to the dynamic stress at the sensor location, and the driver produces a force that is proportional to the voltage applied to it. The analog control system amplifies and phase shifts the sensor signal to produce the voltage signal that is applied to the driver. The feedback control is demonstrated to increase the first mode damping in a cantilever beam by up to 100 percent, depending on the amplifier gain. The damping efficiency of the control system when the piezoelectrics are not optimally positioned at points of high stress in the beam is evaluated.

Gerhold, Carl H.↗

The Commercial Development of Water Repellent Coatings for High Voltage Transmission Lines

The purpose of the Cooperative Research and Development Agreement (CRADA) between UT-Battelle, LLC and Southwire Company was to jointly develop a low cost, commercially viable, water-repellant anti-icing coating system for high voltage transmission lines. Icing of power lines and other structures caused by freezing rain events occurs annually in the United States, and leads to severe and prolonged power outages. These outages cause untold economic and personal distress for many American families and businesses. Researchers at the Department of Energy's Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee have previously developed a set of superhydrophobic coatings with remarkable anti-icing properties that could potentially be sprayed or painted onto high-tension power lines and pylons. These coatings drastically reduce ice accumulation on these structures during freezing rain events. The project involved obtaining technical input, supplies and test high voltage cables from Southwire, along with the joint development of anti-icing coating techniques, which would result in a commercial license agreement between Southwire and ORNL, and potentially other companies requiring water repellent anti-icing coatings.

Hunter, Scott Robert↗

The commercial development of water repellent coatings for high voltage transmission lines

The purpose of the Cooperative Research and Development Agreement (CRADA) between UT-Battelle, LLC and Southwire Company was to jointly develop a low cost, commercially viable, water-repellant anti-icing coating system for high voltage transmission lines. Icing of power lines and other structures caused by freezing rain events occurs annually in the United States, and leads to severe and prolonged power outages. These outages cause untold economic and personal distress for many American families and businesses. Researchers at the Department of Energy's Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee have previously developed a set of superhydrophobic coatings with remarkable anti-icing properties that could potentially be sprayed or painted onto high-tension power lines and pylons. These coatings drastically reduce ice accumulation on these structures during freezing rain events. The project involved obtaining technical input, supplies and test high voltage cables from Southwire, along with the joint development of anti-icing coating techniques, which would result in a commercial license agreement between Southwire and ORNL, and potentially other companies requiring water repellent anti-icing coatings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Solar Array Module Plasma Interactions Experiment (SAMPIE): Science and technology objectives

The Solar Array Module Plasma Interactions Experiment (SAMPIE) is an approved NASA Space Shuttle space flight experiment to be launched in Jul. 1993. The SAMPIE experiment is designed to investigate the interaction of high voltage space power systems with ionospheric plasma. To study the behavior of solar cells, a number of cell coupons, representing technologies of current interest, will be biased to high voltages to characterize both negative potential arcing and positive potential current collection. Additionally, various theories of arc suppression will be tested by including several specially modified cell coupons. Finally, SAMPIE will include experiments to study the basic nature of these interactions. The rationale for a space flight experiment, the measurements to be made, the significance of the expected results, and the current design status of the flight hardware are described.

Hillard, G. Barry↗

Current Flow and Pair Creation at Low Altitude in Rotation-Powered Pulsars' Force-Free Magnetospheres: Space Charge Limited Flow

We report the results of an investigation of particle acceleration and electron-positron plasma generation at low altitude in the polar magnetic flux tubes of rotation-powered pulsars, when the stellar surface is free to emit whatever charges and currents are demanded by the force-free magnetosphere. We apply a new 1D hybrid plasma simulation code to the dynamical problem, using Particle-in-Cell methods for the dynamics of the charged particles, including a determination of the collective electrostatic fluctuations in the plasma, combined with a Monte Carlo treatment of the high-energy gamma-rays that mediate the formation of the electron-positron pairs.We assume the electric current flowing through the pair creation zone is fixed by the much higher inductance magnetosphere, and adopt the results of force-free magnetosphere models to provide the currents which must be carried by the accelerator. The models are spatially one dimensional, and designed to explore the physics, although of practical relevance to young, high-voltage pulsars. We observe novel behaviour (a) When the current density j is less than the Goldreich-Julian value (0 < j/j(sub GJ) < 1), space charge limited acceleration of the current carrying beam is mild, with the full Goldreich-Julian charge density comprising the charge densities of the beam and a cloud of electrically trapped particles with the same sign of charge as the beam. The voltage drops are of the order of mc(sup 2)/e, and pair creation is absent. (b) When the current density exceeds the Goldreich-Julian value (j/j(sub GJ) > 1), the system develops high voltage drops (TV or greater), causing emission of curvature gamma-rays and intense bursts of pair creation. The bursts exhibit limit cycle behaviour, with characteristic time-scales somewhat longer than the relativistic fly-by time over distances comparable to the polar cap diameter (microseconds). (c) In return current regions, where j/j(sub GJ) < 0, the system develops similar bursts of pair creation. These discharges are similar to those encountered in previous calculations by Timokhin of pair creation when the surface has a high work function and cannot freely emit charge. In cases (b) and (c), the intermittently generated pairs allow the system to simultaneously carry the magnetospherically prescribed currents and adjust the charge density and average electric field to force-free conditions. We also elucidate the conditions for pair creating beam flow to be steady (stationary with small fluctuations in the rotating frame), finding that such steady flows can occupy only a small fraction of the current density parameter space exhibited by the force-free magnetospheric model. The generic polar flow dynamics and pair creation are strongly time dependent. The model has an essential difference from almost all previous quantitative studies, in that we sought the accelerating voltage (with pair creation, when the voltage drops are sufficiently large; without, when they are small) as a function of the applied current.

Timokhin, A. N.↗

Submillimeter backward-wave oscillators

A novel submillimeter wave backward-wave oscillator (BWO) that can provide tens of mW of power over a voltage tunable frequency range of more than an octave could serve as the local oscillator for a new class of array sensors in the range from 200 to 2000 GHz. The BWO appears to be the best device available for supporting a wide variety of heterodyne detection systems. It is voltage tunable, able to be phase locked, and can provide sufficient power for all envisioned systems including the arrays of detectors needed for fast data recovery in monitoring upper atmospheric conditions.

Stankiewicz, N.↗

Planar LTCC transformers for high voltage flyback converters: Part II.

This paper is a continuation of the work presented in SAND2007-2591 'Planar LTCC Transformers for High Voltage Flyback Converters'. The designs in that SAND report were all based on a ferrite tape/dielectric paste system originally developed by NASCENTechnoloy, Inc, who collaborated in the design and manufacturing of the planar LTCC flyback converters. The output/volume requirements were targeted to DoD application for hard target/mini fuzing at around 1500 V for reasonable primary peak currents. High voltages could be obtained but with considerable higher current. Work had begun on higher voltage systems and is where this report begins. Limits in material properties and processing capabilities show that the state-of-the-art has limited our practical output voltage from such a small part volume. In other words, the technology is currently limited within the allowable funding and interest.

42 ENGINEERING↗

Distribution Grid Impact Study in Highland Park, Michigan: Understanding Rooftop Solar, Behind-the-Meter Energy Storage, Electric Vehicle Charging, and Building Electrification [Slides]

Through the Communities LEAP (Local Energy Action Program) Pilot, the National Renewable Energy Laboratory (NREL) engaged the Highland Park Stakeholder Coalition to scope four technical assistance work areas to address their energy needs and goals. This slide deck addresses the highlighted tasks under work area "B" related to policy analysis, due diligence, and case studies for removing barriers and providing best practices for local clean energy development. Highland Park community members face frequent, long-duration power interruptions due largely to the aging distribution system serving the area and the legacy design standards used in its construction. While degrading physical infrastructure such as poles, crossarms, and transformers can result in this substandard reliability, another notable characteristic of this legacy system is the lower, 4.8 kV, voltage class. This is a legacy construction standard which many utilities, DTE included, are phasing out in favor of higher, 15 or 25 kV, voltage classes instead. The existing 4.8 kV distribution system serving Highland Park may limit significant adoptions of clean-energy technologies like high percentages of building electrification or electric vehicle adoption. The following analysis seeks to quantify these limitations under a variety of clean-energy technology adoption scenarios. It compares the overall system risks of the present system to those of a hypothetical, upgraded 13.2 kV system, using NREL-developed risk metrics and offers upgrade cost considerations. The legacy 4.8 kV voltage class serving Highland park is not, as we have modeled it, a major limitation to the widespread adoption of cost-optimal rooftop solar and/or behind-the-meter energy storage. Within our modeling framework, these technologies namely impact secondary, low-voltage assets, which may be remedied without the need for a system-wide upgrade to a 13.2 kV voltage class. Our model of the current 4.8kV system indicates it is not capable of supporting community-wide electrification efforts. Widespread building electrification, and the resulting large increase in wintertime load, dramatically increases the prevalence of voltage violations and thermal overloading on the current 4.8 kV distribution system. These impacts illustrate the need for system-wide upgrades to a 13.2 kV voltage class to accommodate these technologies. Low to Moderate DER adoption does not adversely impact the grid but does improve undervoltage and asset overloading issues. However, these benefits are insufficient to defer grid upgrades. Higher DER penetration is shown to increase overvoltage and asset overloading in future electrification scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Dynamic hosting capacity analysis for distributed photovoltaic resources—Framework and case study

Distributed photovoltaic systems can cause adverse distribution system impacts, including voltage violations at customer locations and thermal overload of lines, transformers, and other equipment resulting from high current. The installed capacity at which violations first occur and above which would require system upgrades is called the hosting capacity. Current static methods for determining hosting capacity tend to either consider infrequent worst-case snapshots in time and/or capture coarse time and spatial resolution. Because the duration of violations cannot be captured with these traditional methods, the metric thresholds used in these studies conservatively use the strictest constraints given in operating standards, even though both worse voltage performance and higher overloads may be temporarily acceptable. However, assessing the full details requires accurately capturing time-dependence, voltage-regulating equipment operations, and performance of advanced controls-based mitigation techniques. In this paper, we propose a dynamic distributed photovoltaic hosting capacity methodology to address these issues by conducting power flow analysis for a full year. A key contribution is the formulation of time aware metrics to take these annual results and identify the hosting capacity. Through a case study, we show that this approach can more fully capture grid impacts of distributed photovoltaic than traditional methods and the dynamic hosting capacity was 60%–200% higher than the static hosting capacity in this case study.

14 SOLAR ENERGY↗

Solar array module plasma interactions experiment (SAMPIE) - Science and technology objectives

The solar array module plasma interactions experiment (SAMPIE) is an approved NASA flight experiment manifested for Shuttle deployment in early 1994. The SAMPIE experiment is designed to investigate the interaction of high voltage space power systems with ionospheric plasma. To study the behavior of solar cells, a number of solar cell coupons (representing design technologies of current interest) will be biased to high voltages to measure both arcing and current collection. Various theories of arc suppression will be tested by including several specially modified cell coupons. Finally, SAMPIE will include experiments to study the basic nature of arcing and current collection. This paper describes the rationale for a space flight experiment, the measurements to be made, and the significance of the expected results. A future paper will present a detailed discussion of the engineering design.

Hillard, G. B.↗

Research and Development Toward Massive Liquid Argon Time Projection Chambers for Neutrino Detection

Liquid argon (LAr) time projection chambers (TPC) have rapidly increased in importance as particle detectors throughout the past four decades. While much research has been completed, there are still many areas which require further development to build and operate the next generation LAr TPC experiment, such as the Deep Underground Neutrino Experiment (DUNE). These include high voltage breakdown, argon purification and purity monitoring, and vacuum ultraviolet (VUV) scintillation light measurement. Visual monitoring of high voltage breakdown is helpful in allowing assessment of the performance of high voltage component design. Thus, a system of cryogenic cameras, the first of its kind, was developed for use in a large LAr cryostat, without the need for additional electronics heating. The system functioned without problem for 50 days at cryogenic temperature, with some degradation of image quality, and provided a useful monitor for the DUNE 35-ton cryogenics systems. The system did not observe any high voltage breakdowns during the run. Further development of the concept is ongoing for future installation in other experiments. The monitoring of LAr purity using TPC data is a fundamental study for LAr TPC experiments. However, the study has not been performed for a large LAr TPC in the presence of high electronic noise. Custom software was developed and validated for the accurate reconstruction of signals in noisy TPC data. The results of the reconstruction were used to successfully measure the LAr electron lifetime with an uncertainty comparable to alternate methods of measurement. The electron lifetime of the 35-ton Phase II run is determined to be 4.12 ± 0.17 (stat.) ±0.40 (syst.) ms. For general purpose research and development of high purity LAr as a particle detection medium, a dedicated test stand was designed, constructed, and commissioned. The system is used to test the gaseous photomultiplier (GPM) performance at cryogenic temperatures. The GPM functions with photoelectron multiplication at 77 K, at a reduced gain. Further study is required to show the detector’s direct sensitivity to LAr VUV scintillation light.

Thiesse, Matthew↗

Polarization of gold in nanopores leads to ion current rectification

Biomimetic nanopores with rectifying properties are relevant components of ionic switches, ionic circuits, and biological sensors. Rectification indicates that currents for voltages of one polarity are higher than currents for voltages of the opposite polarity. Ion current rectification requires the presence of surface charges on the pore walls, achieved either by the attachment of charged groups or in multielectrode systems by applying voltage to integrated gate electrodes. Here we present a simpler concept for introducing surface charges via polarization of a thin layer of Au present at one entrance of a silicon nitride nanopore. In an electric field applied by two electrodes placed in bulk solution on both sides of the membrane, the Au layer polarizes such that excess positive charge locally concentrates at one end and negative charge concentrates at the other end. Consequently, a junction is formed between zones with enhanced anion and cation concentrations in the solution adjacent to the Au layer. This bipolar double layer together with enhanced cation concentration in a negatively charged silicon nitride nanopore leads to voltage-controlled surface-charge patterns and ion current rectification. The experimental findings are supported by numerical modeling that confirm modulation of ionic concentrations by the Au layer and ion current rectification even in low-aspect ratio nanopores. Lastly, our findings enable a new strategy for creating ionic circuits with diodes and transistors.

36 MATERIALS SCIENCE↗