Aquarius's Instrument Science Data System (ISDS) Automated to Acquire, Process, Trend Data and Produce Radiometric System Assessment Reports

The Aquarius Radiometer, a subsystem of the Aquarius Instrument required a data acquisition ground system to support calibration and radiometer performance assessment. To support calibration and compose performance assessments, we developed an automated system which uploaded raw data to a ftp server and saved raw and processed data to a database. This paper details the overall functionalities of the Aquarius Instrument Science Data System (ISDS) and the individual electrical ground support equipment (EGSE) which produced data files that were infused into the ISDS. Real time EGSEs include an ICDS Simulator, Calibration GSE, Labview controlled power supply, and a chamber data acquisition system. ICDS Simulator serves as a test conductor primary workstation, collecting radiometer housekeeping (HK) and science data and passing commands and HK telemetry collection request to the radiometer. Calibration GSE (Radiometer Active Test Source) provides source choice from multiple targets for the radiometer external calibration. Power Supply GSE, controlled by labview, provides real time voltage and current monitoring of the radiometer. And finally the chamber data acquisition system produces data reflecting chamber vacuum pressure, thermistor temperatures, AVG and watts. Each GSE system produce text based data files every two to six minutes and automatically copies the data files to the Central Archiver PC. The Archiver PC stores the data files, schedules automated uploads of these files to an external FTP server, and accepts request to copy all data files to the ISDS for offline data processing and analysis. Aquarius Radiometer ISDS contains PHP and MATLab programs to parse, process and save all data to a MySQL database. Analysis tools (MATLab programs) in the ISDS system are capable of displaying radiometer science, telemetry and auxiliary data in near real time as well as performing data analysis and producing automated performance assessment reports of the Aquarius Radiometer.

Source record↗

Calibration technique of wall shear stress sensors using oscillating plate

Disclosed are a system and methods for calibrating wall shear stress sensors. The system includes an oscillating plate coupled to an actuator and mounted on a rolling elements, and one or more sensors coupled to a height adjusting device. The system can further comprise a height control rod coupled to a height control base and a sensor holder configured to house the one or more sensors and supported on a connector, the connector configured to be rotatably disposed about the height control rod. The system can be calibrated by causing the actuator to oscillate the oscillating plate at a frequency, sensing, using the one or more sensors, shear stress at a wall, the shear stress at the wall being associated with a velocity field, and determining a theoretical wall shear stress based on fluid properties, the frequency, and the height of the one or more sensors above the oscillating plate.

Freidkes, Brett R.↗

Calibration improvements to electronically scanned pressure systems and preliminary statistical assessment

Orifice-to-orifice inconsistencies in data acquired with an electronically-scanned pressure system at the beginning of a wind tunnel experiment forced modifications to the standard, instrument calibration procedures. These modifications included a large increase in the number of calibration points which would allow a critical examination of the calibration curve-fit process, and a subsequent post-test reduction of the pressure data. Evaluation of these data has resulted in an improved functional representation of the pressure-voltage signature for electronically-scanned pressures sensors, which can reduce the errors due to calibration curve fit to under 0.10 percent of reading compared to the manufacturer specified 0.10 percent of full scale. Application of the improved calibration function allows a more rational selection of the calibration set-point pressures. These pressures should be adjusted to achieve a voltage output which matches the physical shape of the pressure-voltage signature of the sensor. This process is conducted in lieu of the more traditional approach where a calibration pressure is specified and the resulting sensor voltage is recorded. The fifteen calibrations acquired over the two-week duration of the wind tunnel test were further used to perform a preliminary, statistical assessment of the variation in the calibration process. The results allowed the estimation of the bias uncertainty for a single instrument calibration; and, they form the precursor for more extensive and more controlled studies in the laboratory.

Everhart, Joel L.↗

Calibration of NASA Turbulent Air Motion Measurement System

A turbulent air motion measurement system (TAMMS) was integrated onboard the Lockheed 188 Electra airplane (designated NASA 429) based at the Wallops Flight Facility in support of the NASA role in global tropospheric research. The system provides air motion and turbulence measurements from an airborne platform which is capable of sampling tropospheric and planetary boundary-layer conditions. TAMMS consists of a gust probe with free-rotating vanes mounted on a 3.7-m epoxy-graphite composite nose boom, a high-resolution inertial navigation system (INS), and data acquisition system. A variation of the tower flyby method augmented with radar tracking was implemented for the calibration of static pressure position error and air temperature probe. Additional flight calibration maneuvers were performed remote from the tower in homogeneous atmospheric conditions. System hardware and instrumentation are described and the calibration procedures discussed. Calibration and flight results are presented to illustrate the overall ability of the system to determine the three-component ambient wind fields during straight and level flight conditions.

Barrick, John D. W.↗

3D Printing of Compositional Gradients Using the Microfluidic Circuit Analogy

3D printing of structures with compositional gradients requires accurate dispensing control to achieve desired profiles. Here, empirical data are used with a model based on the microfluidic circuit analogy (MCA) to project dispense rate profiles that yield improved compositional accuracy in the printed part. Since minor variation in the experimental setup for each printing session can result in significant changes, a calibration procedure is developed to measure the system response. This calibration enables the extraction of the empirical MCA model parameters specific to each print session. Using the empirical parameters, the MCA model then can be used to predict appropriate dispense rates for the desired composition profile and toolpath of interest. Here, the MCA model is validated experimentally by direct ink write 3D printing of compositional gradients using viscoelastic polydimethylsiloxane inks and is shown to improve accuracy to desired profile by a factor of 2–5. This approach enables a new route to 3D print structures with arbitrarily complex compositional gradients.

36 MATERIALS SCIENCE↗

Implementation of low temperature spectrometers for the JET high resolution Thomson scattering diagnostic for disruption plasma measurements

This work presents a system upgrade of the High Resolution Thomson Scattering (HRTS) diagnostic on JET that allows it to measure low temperature (1–500 eV) plasma pre- and post-Thermal quench (TQ), which would help us further understand the Shattered Pellet Injection (SPI) physics. The upgrade was done by connecting optic fibers from the original HRTS system to four spectrometers specialized in measuring low temperature plasmas. The upgraded system allows for the measurement of low temperature plasma at up to 12 spatial points, which can be flexibly distributed throughout the JET outer midplane profile during the dedicated SPI experiments. In other JET experiments, four previously unused groups of fibers were used to measure the central plasma to provide disruption data without changing the standard HRTS system. The low temperature Thomson scattering system was installed, commissioned, and cross-calibrated against the standard HRTS diagnostic in a calibration pulse. The system worked reliably during the JET experiments and provided electron density and temperature profiles for pre- and post-TQ low temperature plasmas in the SPI campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A self-certifying FPGA based pixel readout chip test system for CMS ETL upgrade

A flexible self-certifying pixel readout test system for testing the Endcap Timing Read-Out Chip (ETROC) has been developed for the CMS MIP Timing Detector (MTD), part of the upgrade for the HL-LHC. The system includes an FPGA-based (Xilinx KC705) test system that can take data from an emulator or up to four ETROC boards in telescope mode. A python based DAQ system simplifies configuration, calibration, and testing of the chips. The system provides an efficient & reliable solution for testing ETROC (ETROC2 since April 2023 with 16x16 pixels, full-size, full functionality prototype) and can be extended to other readout chips with similar architecture (AIDA integration is currently being explored).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data collection operational support system, part 2

Calibrated signal-strength data obtained at 10 sites in the Rockies and NASA telemetry data regarding the signal levels in the ATS 6 spacecraft are presented along with methodology to use the data to compute the carrier-to-noise rations and signal-to-noise rations at each of the calibrated sites. The data and methodology are also used to estimate the median values of these quantities for sites in the Rockies, Alaska, and Appalachia. Results are discussed.

Source record↗

Optical measurement systems

Some of the areas of research conducted at Lewis on optical measurement techniques are described. Two laser anemometer systems developed at Lewis are used to illustrate the special instrumentation needs encountered in aeropropulsion research. Velocity measurements to be made through small viewing ports, close to surfaces within the propulsion system components, and in turbulent or highly-accelerating flows are some of the significant challenges. The application to research facilities of two advanced optical systems, the rainbow schlieren and the combustor viewing system, is presented. The calibration and verification of commercial optical measuring systems, such as droplet sizing systems, are also discussed. Calibration techniques capable of simulating moving droplets for flight-type sizing systems are being developed at Lewis. The presentation concludes with a brief look at the forces driving future research on optical instrumentation.

Lesco, Daniel J.↗

Calibration of multipolarisation imaging radar

An experiment was designed to calibrate airborne imaging radar (AIR) images, in terms of relative and absolute backscatter, and relative phase between polarization channels. The calibration uses measurements made within the radar system itself (internal calibration) and using ground-based corner reflectors and transponders (external calibration). The techniques developed for the AIR calibration campaign will form the basis of the calibration approach for SIR-C.

Freeman, A.↗

Software For Calibration Of Polarimetric SAR Data

POLCAL (Polarimetric Radar Calibration) software tool intended to assist in calibration of synthetic-aperture radar (SAR) systems. In particular, calibrates Stokes-matrix-format data produced as standard product by NASA/Jet Propulsion Laboratory (JPL) airborne imaging synthetic aperture radar (AIRSAR). Version 4.0 of POLCAL is upgrade of version 2.0. New options include automatic absolute calibration of 89/90 data, distributed-target analysis, calibration of nearby scenes with corner reflectors, altitude or roll-angle corrections, and calibration of errors introduced by known topography. Reduces crosstalk and corrects phase calibration without use of ground calibration equipment. Written in FORTRAN 77.

Van Zyl, Jakob↗

NASA-6 atmospheric measuring station

Information required to calibrate, functionally check, and operate the Instrumentation Branch equipment on the NASA-6 aircraft is provided. All procedures required for preflight checks and in-flight operation of the NASA-6 atmospheric measuring station are given. The calibration section is intended for only that portion of the system maintained and calibrated by IN-MSD-12 Systems Operation contractor personnel. Maintenance is not included.

Source record↗

A review of some radiometric calibration problems and methods

The in-flight radiometric calibration instrumentation and procedures of the Landsat Thematic Mapper and the high-resolution visible-range instruments of SPOT are illustrated with drawings and diagrams, characterized, and compared. Problems encountered in the laboratory calibration process, minimizing the temporal instability of the systems, identifying anomalies in the electronics in flight, and rechecking the calibration are examined, and it is pointed out that the stability of the calibration systems is less than that of the instruments themselves. The use of carefully measured ground-site data and atmospheric parameters in combination with radiative-transfer models for periodic calibration is recommended.

Slater, P. N.↗

Use of an ISOCS-based Waste Assay System for Decommissioning Waste at Trawsfynydd - 19526

Magnox UK Ltd. are decommissioning the former Magnox nuclear power stations in the UK, a process that generates a significant amount of radioactive waste, much of it in the Low Level or Very Low Level categories. It is therefore necessary to perform radiometric assay of the decommissioning waste in order to determine the disposal route and to identify items of waste that are Out of Scope of regulatory control and can therefore be free-released. They have recently commissioned a Canberra On Site Assay System (OSAS) for this purpose. OSAS is a high-resolution gamma-ray spectrometry based waste assay system, which makes use of the ISOCS methodology in order to perform the necessary efficiency calibration of the system for use when assaying the various different containers for the decommissioning waste employed at Trawsfynydd: 210 litre drums, Dolav boxes, wheeled bins and Pac-Tec bulk bags of heavier waste. This publication describes the approach used by Magnox in the processing of the decommissioning waste at Trawsfynydd. It also presents details of the OSAS system and how it was calibrated along with the results from the proof testing of the new system, involving comparison with the results from the assay of waste previously assayed using other monitors. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Automated Integration of Continental-Scale Observations in Near-Real Time for Simulation and Analysis of Biosphere–Atmosphere Interactions

The National Ecological Observatory Network (NEON) is a continental-scale observatory with sites across the US collecting standardized ecological observations that will operate for multiple decades. To maximize the utility of NEON data, we envision edge computing systems that gather, calibrate, aggregate, and ingest measurements in an integrated fashion. Edge systems will employ machine learning methods to cross-calibrate, gap-fill and provision data in near-real time to the NEON Data Portal and to High Performance Computing (HPC) systems, running ensembles of Earth system models (ESMs) that assimilate the data. For the first time gridded EC data products and response functions promise to offset pervasive observational biases through evaluating, benchmarking, optimizing parameters, and training new machine learning parameterizations within ESMs all at the same model-grid scale. Leveraging open-source software for EC data analysis, we are already building software infrastructure for integration of near-real time data streams into the International Land Model Benchmarking (ILAMB) package for use by the wider research community. We will present a perspective on the design and integration of end-to-end infrastructure for data acquisition, edge computing, HPC simulation, analysis, and validation, where Artificial Intelligence (AI) approaches are used throughout the distributed workflow to improve accuracy and computational performance.

Durden, David J.↗

XCal: model-based approach to X-ray CT spectral calibration

Transmission X-ray computed tomography (CT) is widely used to quantitatively reconstruct 3D objects composed of multiple materials. However, accurate CT reconstruction requires the system to be calibrated to account for the effective X-ray spectrum. Unfortunately, measurement of the effective spectrum is ill-posed, and existing calibration methods require that the system be recalibrated when the system parameters are changed. In this paper, we propose XCal, a multi-energy model-based spectral calibration approach for X-ray CT. The XCal approach models the effective spectrum using a separable physics-based model of the CT system. The model parameters are then estimated by fitting calibration data with known objects at multiple energies. An important advantage of XCal is that it allows the user to change scanner settings, such as the source voltage or X-ray filters, without the need for recalibration. Evaluations on simulated and measured datasets demonstrate that XCal significantly improves the accuracy of the estimated spectrum as compared to existing calibration methods.

Li, Wenrui [Purdue Univ., West Lafayette, IN (Unit↗

Absolute photometric calibration of detectors to 0.3 mmag using amplitude-stabilized lasers and a helium-cooled absolute radiometer

Laser sources whose intensity is determined with a cryogenic electrical substitution radiometer are described. Detectors are then calibrated against this known flux, with an overall error of 0.028 percent (0.3 mmag). Ongoing research has produced laser intensity stabilizers with flicker and drift of less than 0.01 percent. Recently, the useful wavelength limit of these stabilizers have been extended to 1.65 microns by using a new modular technology and InGaAs detector systems. Data from Si photodiode calibration using the method of Zalewski and Geist are compared against an absolute cavity radiometer calibration as an internal check on the calibration system.

Miller, Peter J.↗