Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “surface wave”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Advanced satellite communication system

The objective of this research program was to develop an innovative advanced satellite receiver/demodulator utilizing surface acoustic wave (SAW) chirp transform processor and coherent BPSK demodulation. The algorithm of this SAW chirp Fourier transformer is of the Convolve - Multiply - Convolve (CMC) type, utilizing off-the-shelf reflective array compressor (RAC) chirp filters. This satellite receiver, if fully developed, was intended to be used as an on-board multichannel communications repeater. The Advanced Communications Receiver consists of four units: (1) CMC processor, (2) single sideband modulator, (3) demodulator, and (4) chirp waveform generator and individual channel processors. The input signal is composed of multiple user transmission frequencies operating independently from remotely located ground terminals. This signal is Fourier transformed by the CMC Processor into a unique time slot for each user frequency. The CMC processor is driven by a waveform generator through a single sideband (SSB) modulator. The output of the coherent demodulator is composed of positive and negative pulses, which are the envelopes of the chirp transform processor output. These pulses correspond to the data symbols. Following the demodulator, a logic circuit reconstructs the pulses into data, which are subsequently differentially decoded to form the transmitted data. The coherent demodulation and detection of BPSK signals derived from a CMC chirp transform processor were experimentally demonstrated and bit error rate (BER) testing was performed. To assess the feasibility of such advanced receiver, the results were compared with the theoretical analysis and plotted for an average BER as a function of signal-to-noise ratio. Another goal of this SBIR program was the development of a commercial product. The commercial product developed was an arbitrary waveform generator. The successful sales have begun with the delivery of the first arbitrary waveform generator.

Staples, Edward J.↗

Using a temperature-controlled quartz crystal microbalance in a space equipment cleanroom to monitor molecular contamination

There is a need for continuous monitoring for molecular contamination in clean rooms where spaceflight equipment is assembled, integrated, and tested to insure that contamination budgets are met. The TQCM (temperature-controlled quartz crystal microbalance) can be used to provide both a real time warning and a cumulative measurement of molecular contamination. It has advantages over the other measurement methods such as witness mirrors, NVR (non-volatile residue) plates, and gas analyzers. A comparison of the TQCM sensitivity and ease of operations is made with the other methods. The surface acoustic wave microbalance (SAW), a newly developed instrument similar to TQCM, is considered in the comparison. An example is provided of TQCM use at Goddard Space Flight Center when the Wide Field Planetary Camera 2(WFPC-2) and the Corrective Optics Space Telescope Axial Replacement (COSTAR) were undergoing integrated testing prior to their installation in the Hubble Space Telescope on its first servicing mission. Areas for further investigation are presented.

Mitchell, William J.↗

Effect of nonlinear interactions on p-mode frequencies and line widths

We calculate the effect of nonlinear interactions among solar acoustic modes upon the modal frequencies and energy loss rates (or line widths). The frequency shift for a radial p-mode of frequency 3 mHz is found to be about -0.5 microHz. The magnitude of nonlinear frequency shift increases more rapidly with frequency than the inverse mode mass (mode mass is defined as the ratio of energy in the mode to its surface velocity amplitude squared). This frequency shift is primarily due to nonresonant three-mode interactions and is dominated by high l surface gravity waves (f-modes) and p-modes. The line width of a radial p-mode of frequency 3 mHz, due to resonant nonlinear interactions, is about 0.3 microHz. This result is consistent with that of Kumar and Goldreich (1989). We also find, in agreement with these authors, that the most important nonlinear interactions of trapped p-modes involve f-modes and high-frequency p-modes (frequency greater than about 5 mHz) which propagate in the solar photosphere. Thus, using the arguments advanced by Kumar & Goldreich (1989), we conclude that nonlinear couplings cannot saturate the overstable solar p-modes at their small observed amplitudes. Both the nonlinear frequency shifts and line widths, at a fixed frequency, are proportional to the inverse of mode mass which for modes of degree greater than about 100 is approximately l(exp 0.8). Therefore, the frequency of an f-mode of l = 1000, due to nonlinear interactions, is decreased by approximately 0.4%.

Kumar, Pawan↗

An X-ray and optical study of the interaction of the Cygnus Loop supernova remnant with an interstellar cloud

We have used the ROSAT high-resolution imager and optical emission line data to study the structure of a bright optical knot on the southeastern rim of the Cygnus Loop supernova remnant. This knot has been identified as an encounter between the blast wave and a small isolated cloud. The knot appears in projection just behind the blast wave, which is traced by Balmer line filaments which bound the X-ray emission. The knot is a prominent X-ray feature, consisting of a numerb of filaments which are correlated with the optical line emission. These data permit a detailed view of the blast wave interaction. By combining the optical and X-ray data it is possible to trace the blast wave as a continuous surface from its southern edge around the western side of the cloud that then continues on to the north. The southeastern knot is an indentation on the surface of the blast wave. Thus the southeastern knot is not a small cloud that has been overrun by the blast wave, but the tip of a larger cloud. Bright X-ray emission is associated with bright radiative filaments. The location of this emission, upstream of the radiative shocks, implies that the enhanced X-rays come from a reverse shock. The presence of a reverse shock is further evidence that the southeastern knot represents an early stage of a blast wave encountering a large cloud. A consistent picture of the Cygnus Loop as an explosion within a preexisting cavity is emerging. These observations agree with that picture.

Graham, James, R.↗

Reflection Properties of Metallic Gratings on ZnO Films over GaAs Substrates

A potential application for piezoelectric film deposited on GaAs substrates is the monolithic integration of surface acoustic wave (SAW) devices with GaAs electronics. Metallic gratings are basic elements required for the construction of such devices, and analyzing the reflectivity and the velocity change due to metallic gratings is often a critical design parameter. In this article, Datta and Hunsinger technique is extended to the case of a multilayered structure, and the developed technique is applied to analyze shorted and open gratings on ZnO films sputtered over (001)-cut (110)-propagating GaAs substrates. The analysis shows that zero reflectivity of shorted gratings can be obtained by a combination of the ZnO film and the metal thickness and the metalization ratio of the grating. Experiments are performed on shorted and an open gratings (with the center frequency of about 180 MHz) for three different metal thicknesses over ZnO films which are 0.8 and 2.6 micrometers thick. From the experiments, zero reflectivity at the resonant frequency of the grating is observed for a reasonable thickness (h/Alpha = 0.5%) of aluminum metalization. The velocity shift between the shorted and the open grating is also measured to be 0.18 MHz and 0.25 MHz for 0.8 and 1.6 micrometers respectively. The measured data show relatively good agreement with theoretical predictions.

Hickernell, Fred S.↗

Calibration of the QCM/SAW Cascade Impactor for Measurement of Ozone in the Stratosphere

The Quartz Crystal Microbalance Surface Acoustic Wave (QCM/SAW) cascade impactor collects size-fractionated distributions of aerosols on a series of 10 MHz quartz crystals and employs SAW devices coated with chemical sensors for gas detection. Presently, we are calibrating the ER-2 certified QCM/SAW cascade impactor in the laboratory for the detection of ozone. Experiments have been performed to characterize the QCM and SAW mass loading, saturation limits, mass frequency relationships, and sensitivity. We are also characterizing sampling efficiency by measuring the loss of ozone on different materials. There are parallel experiments underway to measure the variations in the sensitivity and response of the QCM/SAW crystals as a function of temperature and pressure. Results of the work to date will be shown.

Wright, Cassandra K.↗

New Polymer Coatings for Chemically Selective Mass Sensors

There is a current need to develop sensitive and chemically specific sensors for the detection of nitric acid for in-situ measurements in the atmosphere. Polymer coatings have been synthesized and tested for their sensitivity and selectivity to nitric acid. A primary requirement for these polymers is detectability down to the parts per trillion range. The results of studies using these polymers as coatings for quartz crystal microbalances (QCM) and surface acoustic wave (SAW) devices will be presented.

Sims, S. C.↗

FTIR Spectroscopy of HNO3 and NO2 Relevant to Stratospheric Wake Analysis

The Fourier Transform Infrared (FTIR) technique has been employed to measure absolute concentrations of nitric acid (HNO3) and nitrogen dioxide (NO2) with 1/cm resolution and an absorption pathlength of 4 m under quasi-static and flow conditions at atmospheric pressure and room temperature. Water features seen under quasi-static conditions diminished in intensity under flowing conditions. Nitric acid was observed in the 1660-1760/cm range, while nitrogen dioxide was detected both in the 1536-1660 and 1213-1400/cm ranges. Concentrations of nitrogen dioxide and nitric acid were determined to be 11.9 and 4.35 parts per million (ppm), respectively, with an uncertainty of 0.2 ppm. Experiments are underway with a 10 m cell to measure the absorption of nitric acid, water, sulfur dioxide, hydrochloric acid and ammonia on various materials such as glass, teflon, stainless steel and aluminum used for implementation of the flow system. Such materials will be used for the measurements of stratospheric trace gases by the Quartz Crystal Microbalance (QCM) and Surface Acoustic Wave (SAW) devices.

Abina, Rafiu A.↗

An Acoustic Charge Transport Imager for High Definition Television Applications: Low-Voltage SAW Amplifiers on Multilayer GaAs/ZnO Substrates

This thesis addresses the acoustoelectric issues concerning the amplification of surface acoustic waves (SAWs) and the reflection of SAWs from slanted reflector gratings on GaAs, with application to a novel acoustic charge transport (ACT) device architecture. First a simple model of the SAWAMP was developed, which was subsequently used to define the epitaxially grown material structure necessary to provide simultaneously high resistance and high electron mobility. In addition, a segmented SAWAMP structure was explored with line widths on the order of an acoustic wavelength. This resulted in the demonstration of SAWAMPS with an order of magnitude less voltage and power requirements than previously reported devices. A two-dimensional model was developed to explain the performance of devices with charge confinement layers less then 0.5 mm, which was experimentally verified. This model was extended to predict a greatly increased gain from the addition of a ZnO overlay. These overlays were experimentally attempted, but no working devices were reported due to process incompatibilities. In addition to the SAWAMP research, the reflection of SAWs from slanted gratings on GaAs was also studied and experimentally determined reflection coefficients for both 45 deg grooves and Al stripes on GaAs have been reported for the first time. The SAWAMp and reflector gratings were combined to investigate the integrated ring oscillator for application to the proposed ACT device and design parameters for this device have been provided.

Hunt, W. D.↗

An Acoustic Charge Transport Imager for High Definition Television

This project, over its term, included funding to a variety of companies and organizations. In addition to Georgia Tech these included Florida Atlantic University with Dr. William E. Glenn as the P.I., Kodak with Mr. Mike Richardson as the P.I. and M.I.T./Polaroid with Dr. Richard Solomon as the P.I. The focus of the work conducted by these organizations was the development of camera hardware for High Definition Television (HDTV). The focus of the research at Georgia Tech was the development of new semiconductor technology to achieve a next generation solid state imager chip that would operate at a high frame rate (I 70 frames per second), operate at low light levels (via the use of avalanche photodiodes as the detector element) and contain 2 million pixels. The actual cost required to create this new semiconductor technology was probably at least 5 or 6 times the investment made under this program and hence we fell short of achieving this rather grand goal. We did, however, produce a number of spin-off technologies as a result of our efforts. These include, among others, improved avalanche photodiode structures, significant advancement of the state of understanding of ZnO/GaAs structures and significant contributions to the analysis of general GaAs semiconductor devices and the design of Surface Acoustic Wave resonator filters for wireless communication. More of these will be described in the report. The work conducted at the partner sites resulted in the development of 4 prototype HDTV cameras. The HDTV camera developed by Kodak uses the Kodak KAI-2091M high- definition monochrome image sensor. This progressively-scanned charge-coupled device (CCD) can operate at video frame rates and has 9 gm square pixels. The photosensitive area has a 16:9 aspect ratio and is consistent with the "Common Image Format" (CIF). It features an active image area of 1928 horizontal by 1084 vertical pixels and has a 55% fill factor. The camera is designed to operate in continuous mode with an output data rate of 5MHz, which gives a maximum frame rate of 4 frames per second. The MIT/Polaroid group developed two cameras under this program. The cameras have effectively four times the current video spatial resolution and at 60 frames per second are double the normal video frame rate.

Hunt, William D.↗

Mode Profiles in Waveguide-Coupled Resonators

Surface acoustic wave (SAW) waveguide-coupled resonators are of considerable interest for narrow-band filter applications, though to date there has been very little published on the acoustic details of their operation. As in any resonator, one must fully understand its mode structure and herein we study the SAW mode profiles in these devices. Transverse mode profiles in the resonant cavity of the device were measured at various frequencies of interest using a knife-edge laser probe. In addition we predict the mode profiles for the device structure by two independent methods. One is a stack-matrix approach adapted from integrated optics and the other is a conventional analytical eigenmode analysis of the Helmholtz equation. Both modeling techniques are in good agreement with the measured results.

Hunt, William D.↗

Structural Loading on the QCM/SAW Instrument Aboard the ER-2 Used for Atmospheric Testing

Several experiments have been proposed to capture and evaluate samples of the atmosphere where SST's travel. One means to achieve this is to utilize the quartz crystal microbalance (QCM) / surface acoustical wave (SAW) instrument installed aboard the ER-2, formerly the U-2 reconnaissance aircraft. The QCM is a cascade impactor designed to perform in-situ, real-time measurements of aerosols and chemical vapors at an altitude of 60,000-70,000 feet. The primary use of the ER-2 is by NASA for Earth resources to test new sensor systems before being placed aboard satellites. One of the main reasons the ER-2 is used for this flight experiment is its capability to fly approximately twelve miles above the sea level (can reach an altitude of 78,000 feet). Because the ER-2 operates at such a high altitude, it is of special interest to scientists interested in space exploration or supersonic aircraft. The purpose of some of the experiments is to extinct data from the atmosphere around the ER-2. For the current CSTEA flight experiment, the housing of the QCM is in a frame that connects to an outer pod that attaches to the fuselage of the ER-2. Due to the location of the QCM within the housing frame and the location of the pod on the ER-2, the pod and its contents are subject to structural loads. In addition to structural loads, structural vibrations are also of importance because the QCM output data is based on the determination of beat frequencies between a pair of oscillators (one coated, the second uncoated, according to the chemical reaction being monitored). A structural analysis of this system can indicate whether potential resonances may exist between the (higher) structural modal frequencies and the beat frequencies. In addition undesirable deformations may result due to maximum expected static or dynamic loads during typical flight conditions. If the deformations are excessive they may adversely affect the accuracy the instrumentation output.

Bainum, Peter M.↗

Laboratory Study of Water Surface Roughness Generation by Wave-Current Interaction

Within the framework of this project, the blocking of waves by inhomogeneous currents was studied. A laboratory experiment was conducted in collaboration with Steven R. Long at the linear wave tank of the NASA Air-Sea Interaction Facility, Wallops Island, VA during May 1999. Mechanically-generated waves were blocked approximately 3m upstream from the wave paddle by an opposing current. A false bottom was used to obtain a spatially varying flow field in the measurement section of the wave tank. We used an imaging slope gauge, which was mounted directly underneath the sloping section of the false tank bottom to observe the wave field. For a given current speed, the amplitude and the frequency of the waves was adjusted so that the blocking occurred within the observed footprint. Image sequences of up to 600 images at up 100 Hz sampling rate were recorded for an area of approximately 25cm x 25cm. Unlike previous measurements with wave wire gauges, the captured image sequences show the generation of the capillary waves at the blocking point and give detailed insight into the spatial and temporal evolution of the blocking process. The image data were used to study the wave-current interaction for currents from 5 to 25 cm/s and waves with frequencies between 1 and 3 Hz. First the images were calibrated with regard to size and slope. Then standard Fourier techniques as well the empirical mode decomposition method developed by Dr. Norden Huang and Dr. Steven R. Long were employed to quantify the wave number downshift from the gravity to the capillary regime.

Klinke, Jochen↗

Clues from the SWIR: Mineralogical Constraints from 1 to 4 microns

Among the great Mars mineral problems are the predictions of both carbonates and clays as alteration products and the lack of observational evidence to support those predictions. In spite of geochemical evidence of sulfur and chlorine in the soils, assignment of specific sulfates and chlorides has remained elusive. The purpose of this contribution is to show several common alteration minerals that are consistent with the short-wave infrared surface spectra and geochemistry, briefly consider the silicate problem, propose an additional method of soil formation and review what surface measurements in the spectral range from approximately 1 to 4 microns can do to help resolve remaining ambiguities of surface mineralogy. Additional information is contained in the original extended abstract.

Calvin, W. M.↗

Calibration of the QCM/SAW Cascade Impactor for Measurement of Ozone

The Quartz Crystal Microbalance Surface Acoustic Wave (QCM/SAW) cascade impactor is an instrument designed to collect size-fractionated distributions of aerosols on a series of quartz crystals and employ SAW devices coated with chemical sensors for gas detection. We are calibrating the cascade impactor in our laboratory for future deployment for in-situ experiments to measure ozone. Experiments have been performed to characterize the QCM and SAW mass loading, saturation limits, mass frequency relationships, and sensitivity. The characteristics of mass loading, saturation limits, mass-frequency relationships, sensitivity, and the loss of ozone on different materials have been quantified.

Williams, Cassandra K.↗

Small Business Innovations (Mass Microbalance)

Femtometrics of Costa Mesa, CA, developed the Model 200-1 SAW Mass Microbalance under a NASA Small Business Innovation Research (SBIR) contract with Langley Research Center. The product is described as "the next generation of aerosol mass microbalance technology," because a new type of sensor, the Surface Acoustic Wave (SAW) piezoelectric crystal, offers mass resolution two orders of magnitude greater than the Quartz Crystal Microbalance cascade impactor (QCM) (used at Langley since 1979 for collection and measurement of aerosol particles in the upper atmosphere). The Model 200-1 SAW Mass Microbalance, which provides a 400-fold increase in mass sensitivity per unit area over the QCM, can be used for real-time particle monitoring in clean rooms, measuring chemical vapors in very low concentrations, measuring target chemicals in the stratosphere and in industry as a toxic vapor monitor.

Source record↗

Cones in Supersonic Flow

In the case of cones in axially symmetric flow of supersonic velocity, adiabatic compression takes place between shock wave and surface of the cone. Interpolation curves betwen shock polars and the surface are therefore necessary for the complete understanding of this type of flow. They are given in the present report by graphical-numerical integration of the differential equation for all cone angles and airspeeds.

Hantzsche, W.↗

Validation and Improvement of CERES Surface Radiation Budget Algorithms: Extension of Dusty and Cloudy Scenes

Our main task was to validate and improve the generation of surface long wave fluxes from the CERES TOA window channel flux measurements. We completed this task successfully for the clear sky fluxes in the presence of aerosols including dust during the first year of the project. The algorithm we developed for CERES was remarkably successful for clear sky fluxes and we have no further tasks that need to be performed past the requested termination date of December 31, 2004. We found that the information contained in the TOA fluxes was not sufficient to improve upon the current CERES algorithm for cloudy sky fluxes. Given this development and given our success in clear sky fluxes, we do not see any reason to continue our validation work beyond what we have completed. Specific details are given.

Ramanathan, V.↗