Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “statistical analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Bladder–Rectum Spacer Balloon in High-Dose-Rate Brachytherapy in Cervix Carcinoma

Purpose: To compare bladder and rectum doses with the use of a bladder–rectum spacer balloon (BRSB) versus standard gauze packing in the same patient receiving 2 high-dose-rate intracavitary brachytherapy fractions. Methods and Materials: This was a randomized study to compare the reduction in bladder and rectum doses with the use of a BRSB compared with standard gauze packing in patients with carcinoma of the cervix being treated with high-dose-rate intracavitary brachytherapy. The patients were randomized between 2 arms. In arm A, vaginal packing was done with standard gauze packing in the first application, and BRSB was used in the second application. Arm B was the reverse of arm A. The International Commission for Radiation Units and Measurement (ICRU) point doses and doses to 0.1-cm{sup 3}, 1-cm{sup 3}, 2-cm{sup 3}, 5-cm{sup 3}, and 10-cm{sup 3} volumes of bladder and rectum were compared. The patients were also subjectively assessed for the ease of application and the time taken for application. Statistical analysis was done using the paired t test. Results: A total of 43 patients were enrolled; however, 3 patients had to be excluded because the BRSB could not be inserted owing to unfavorable local anatomy. Thus 40 patients (80 plans) were evaluated. The application was difficult in 3 patients with BRSB, and in 2 patients with BRSB the application time was prolonged. There was no significant difference in bladder doses to 0.1 cm{sup 3}, 1 cm{sup 3}, 2 cm{sup 3}, 5 cm{sup 3}, and 10 cm{sup 3} and ICRU bladder point. Statistically significant dose reductions to 0.1-cm{sup 3}, 1-cm{sup 3}, and 2-cm{sup 3} volumes for rectum were observed with the BRSB. No significant differences in 5-cm{sup 3} and 10-cm{sup 3} volumes and ICRU rectum point were observed. Conclusion: A statistically significant dose reduction was observed for small high-dose volumes in rectum with the BRSB. The doses to bladder were comparable for BRSB and gauze packing. Transparent balloons of variable sizes are recommended for patients with a less spacious vaginal cavity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Classification of Cloud Particle Imagery from Aircraft Platforms Using Convolutional Neural Networks

Abstract A vast amount of ice crystal imagery exists from a variety of field campaign initiatives that can be utilized for cloud microphysical research. Here, nine convolutional neural networks are used to classify particles into nine regimes on over 10 million images from the Cloud Particle Imager probe, including liquid and frozen states and particles with evidence of riming. A transfer learning approach proves that the Visual Geometry Group (VGG-16) network best classifies imagery with respect to multiple performance metrics. Classification accuracies on a validation dataset reach 97% and surpass traditional automated classification. Furthermore, after initial model training and preprocessing, 10 000 images can be classified in approximately 35 s using 20 central processing unit cores and two graphics processing units, which reaches real-time classification capabilities. Statistical analysis of the classified images indicates that a large portion (57%) of the dataset is unusable, meaning the images are too blurry or represent indistinguishable small fragments. In addition, 19% of the dataset is classified as liquid drops. After removal of fragments, blurry images, and cloud drops, 38% of the remaining ice particles are largely intersecting the image border (≥10% cutoff) and therefore are considered unusable because of the inability to properly classify and dimensionalize. After this filtering, an unprecedented database of 1 560 364 images across all campaigns is available for parameter extraction and bulk statistics on specific particle types in a wide variety of storm systems, which can act to improve the current state of microphysical parameterizations.

54 ENVIRONMENTAL SCIENCES↗

The Spiral Arm Segments of the Galaxy within 3 kpc from the Sun: A Statistical Approach

As can be reasonably expected, upcoming large-scale APOGEE, GAIA, GALAH, LAMOST, and WEAVE stellar spectroscopic surveys will yield rather noisy Galactic distributions of stars. In view of the possibility of employing these surveys, our aim is to present a statistical method to extract information about the spiral structure of the Galaxy from currently available data, and to demonstrate the effectiveness of this method. The model differs from previous works studying how objects are distributed in space in its calculation of the statistical significance of the hypothesis that some of the objects are actually concentrated in a spiral. A statistical analysis of the distribution of cold dust clumps within molecular clouds, H ii regions, Cepheid stars, and open clusters in the nearby Galactic disk within 3 kpc from the Sun is carried out. As an application of the method, we obtain distances between the Sun and the centers of the neighboring Sagittarius arm segment, the Orion arm segment in which the Sun is located, and the Perseus arm segment. Pitch angles of the logarithmic spiral segments and their widths are also estimated. The hypothesis that the collected objects accidentally form spirals is refuted with almost 100% statistical confidence. We show that these four independent distributions of young objects lead to essentially the same results. We also demonstrate that our newly deduced values of the mean distances and pitch angles for the segments are not too far from those found recently by Reid et al. using VLBI-based trigonometric parallaxes of massive star-forming regions.

79 ASTRONOMY AND ASTROPHYSICS↗

Cladding Profilometry Analysis of Experimental Breeder Reactor-II Metallic Fuel Pins with HT9, D9, and SS316 Cladding

BISON finite element method fuel performance simulations were conducted using an existing automated process that couples the Fuels Irradiation & Physics Database (FIPD) and the Integral Fast Reactor Materials Information System database by writing input files and comparing the BISON output to post-irradiation fuel pin profilometry measurements contained within the databases. The importance of this work is to demonstrate the ability to benchmark fuel performance metallic fuel models within BISON using Experimental Breeder Reactor-II fuel pin data for a number of similar pins, while building off previous modeling efforts. Changes to the generic BISON input file include implementing pin specific axial power and flux profiles, pin specific fluences, frictional contact, and irradiation-induced volumetric swelling models for cladding. A statistical analysis of irradiation-induced volumetric swelling models for HT9, D9, and SS316 was performed for experiments X421/X421A, X441/X441A, and X486. Between these three experiments, there were 174 post-irradiation examination (PIE) profilometries used for validating the swelling models presented using a standard error of the estimate (SEE) method. Implementation of the volumetric swelling models for D9 and SS316 claddings was found to have a significant impact on the BISON profilometry simulated, where HT9 clad pins had an insignificant change due to low fluence values. BISON profilometry simulated for HT9, D9, and SS316 fuel pins agreed with PIE profilometry measurements, with assembly SEE values being 4.4 × 10−3 for X421A, 2.0 × 10−3 for X441A, and 2.8 × 10−3 for X486. D9 clad pins in X421/X421A had the highest SEE values, which is due to the BISON simulated profilometry being shifted axially. While this work accomplished its purpose to demonstrate the modeling of multiple fuel pins from the databases to help validate models, the results suggest that the continued development of metallic fuel models is necessary for qualifying new metallic fuel systems to better capture some physical performance phenomena, such as the hot pressing of U-Pu-Zr and the fuel cladding chemical interaction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Coupled Location/Depth/Yield Problem for North Korea’s Declared Nuclear Tests

On 3 September 2017, the Democratic People's Republic of Korea (DPRK) conducted its sixth and largest declared nuclear test at the Pung'gye Ri test site. Recently, we have been using regional waveform envelopes to estimate the explosive yield and overburden of chemical and nuclear explosions by coupling explosion source models to propagation parameters. Like most yield determination methods, there can be tradeoffs between yield and depth, leading to uncertainties in both parameters. The relative locations are well-constrained by small timing differences in seismic-phase arrivals at stations that recorded multiple events, but there are potential uncertainties on the absolute locations. Depths are poorly constrained by the relative arrival times. In this study, we have performed a coupled location and yield analysis of the DPRK nuclear tests. We use correlation methods to get highly accurate travel times and relative locations using a Bayesian location method. Then, while keeping the relative locations of the six tests constant, we consider the consequences of shifts to the absolute locations on the resulting overburden for each event. Given that overburden, we determine the yield that minimizes the waveform misfit. We also test and compare a number of explosion source models. By considering the coupled location/depth/yield problem, we reduce uncertainties in the absolute locations, and yield and depth estimates of the events. Based on statistical analysis, we estimate that the 2017 test has a yield of 125 kilotons (equivalent TNT) with a 1 sigma uncertainty range of 103-150 ktons at about 600 m of overburden.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Performance assessment of near-fault buildings subjected to physics-based simulated earthquake ground motions with fling step

The effects of the co-seismic static offset (known as fling step) and associated velocity pulses on civil structures have been difficult to study because the static offset is typically removed during the processing of earthquake ground motion records. Simulated ground motions contain fling features and require no processing; therefore, they create new opportunities for representing fling features in seismic hazard analysis and assessing their influence on the seismic demands on near-fault structures. We use physics-based fault rupture simulations to study the characteristics of ground motions with fling step and the sensitivity of the near-fault structural demands to strong fling features. We uncover that simulated ground motions with a large fling step tend to have higher spectral intensity than those without a fling step at the same rupture distance, especially at periods longer than 2 s. As a result, the structural demands on flexible buildings tend to be the most sensitive to the fling features. Statistical analysis suggests that the ground motion spectral shape (represented by spectral accelerations at multiple periods) is—in most cases—a sufficient predictor of the structural demands on near-fault low-rise and mid-rise buildings at locations that are susceptible to strong fling effects. Finally, ground motion record selection experiments reveal that representing the spectral shape features at periods that are most relevant to a given structure may be an effective strategy to reduce the bias in the estimated demands on near-fault long-period structures when the available database of records is considered deficient in fling features.

Fling step↗

Consistent Nuclear Data Evaluations for Criticality Safety

Evaluations of nuclear data are based on statistical analysis of available experimental data and their uncertainties plus model calculations and their uncertainties. As the models are currently rather limited, the evaluations are heavily biassed toward experimental data, with the caveat that a thorough analysis is also required to understand possible discrepancies between data sets. Hence, as new experimental data become available, they are incorporated into the evaluation procedure. Recent measurements of the 233 U capture to fission cross section ratio at the Los Alamos Neutron Science Center have prompted a re-evaluation of the capture cross section in the resonance and fast regions up to 250 keV. We will discuss the challenges of including the new fast neutron experimental data in an evaluation that is consistent with the resonance region. We will also discuss our consistent evaluation procedure based on the Hauser-Feshbach statistical model for nuclear reactions and its application to the evaluations of 239 Pu and 139 La neutron-induced reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MO-F-CAMPUS-I-01: Accuracy of Radiologists Interpretation of Mammographic Breast Density

Purpose: Several commercial and non-commercial software and techniques are available for determining breast density from mammograms. However, where mandated by law the breast density information communicated to the subject/patient is based on radiologist’s interpretation of breast density from mammograms. Several studies have reported on the concordance among radiologists in interpreting mammographic breast density. In this work, we investigated the accuracy of radiologist’s interpretation of breast density. Methods: Volumetric breast density (VBD) determined from 134 unilateral dedicated breast CT scans from 134 subjects was considered the truth. An MQSA-qualified study radiologist with more than 20 years of breast imaging experience reviewed the DICOM “for presentation” standard 2-view mammograms of the corresponding breasts and assigned BIRADS breast density categories. For statistical analysis, the breast density categories were dichotomized in two ways; fatty vs. dense breasts where “fatty” corresponds to BIRADS breast density categories A/B, and “dense” corresponds to BIRADS breast density categories C/D, and extremely dense vs. fatty to heterogeneously dense breasts, where extremely dense corresponds to BIRADS breast density category D and BIRADS breast density categories A through C were grouped as fatty to heterogeneously dense breasts. Logistic regression models (SAS 9.3) were used to determine the association between radiologist’s interpretation of breast density and VBD from breast CT, from which the area under the ROC (AUC) was determined. Results: Both logistic regression models were statistically significant (Likelihood Ratio test, p<0.0001). The accuracy (AUC) of the study radiologist for classification of fatty vs. dense breasts was 88.4% (95% CI: 83–94%) and for classification of extremely dense breast was 94.3% (95% CI: 90–98%). Conclusion: The accuracy of the radiologist in classifying dense and extremely dense breasts is high. Considering the variability in VBD estimates from commercial software, the breast density information communicated to the patient should be based on radiologist’s interpretation. This work was supported in part by NIH R21 CA176470 and R21 CA134128. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or NCI.

60 APPLIED LIFE SCIENCES↗

Search for charged Higgs bosons decaying via H ± → τ ± ν in fully hadronic final states using pp collision data at s $$ \sqrt{s} $$ = 8 TeV with the ATLAS detector

The results of a search for charged Higgs bosons decaying to a τ lepton and a neutrino, H ± → τ ± ν, are presented. The analysis is based on 19.5 fb –1 of proton-proton collision data at √s = 8 TeV collected by the ATLAS experiment at the Large Hadron Collider. Charged Higgs bosons are searched for in events consistent with top-quark pair production or in associated production with a top quark, depending on the considered H ± mass. The final state is characterized by the presence of a hadronic τ decay, missing transverse momentum, b-tagged jets, a hadronically decaying W boson, and the absence of any isolated electrons or muons with high transverse momenta. The data are consistent with the expected background from Standard Model processes. A statistical analysis leads to 95% confidence-level upper limits on the product of branching ratios Β(t → bH ± ) × Β(H ± → τ ± ν), between 0.23% and 1.3% for charged Higgs boson masses in the range 80-160GeV. It also leads to 95% confidence-level upper limits on the production cross section times branching ratio, σ(pp → tH ± + X) × Β(H ± → τ ± ν), between 0.76 pb and 4.5 fb, for charged Higgs boson masses ranging from 180 GeV to 1000 GeV. In the context of different scenarios of the Minimal Supersymmetric Standard Model, these results exclude nearly all values of tan β above one for charged Higgs boson masses between 80 GeV and 160 GeV, and exclude a region of parameter space with high tan β for H ± masses between 200 GeV and 250 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison study of the partial-breast irradiation techniques: Dosimetric analysis of three-dimensional conformal radiation therapy, electron beam therapy, and helical tomotherapy depending on various tumor locations

The partial-breast irradiation (PBI) technique, an alternative to whole-breast irradiation, is a beam delivery method that uses a limited range of treatment volume. The present study was designed to determine the optimal PBI treatment modalities for 8 different tumor locations. Treatment planning was performed on computed tomography (CT) data sets of 6 patients who had received lumpectomy treatments. Tumor locations were classified into 8 subsections according to breast quadrant and depth. Three-dimensional conformal radiation therapy (3D-CRT), electron beam therapy (ET), and helical tomotherapy (H-TOMO) were utilized to evaluate the dosimetric effect for each tumor location. Conformation number (CN), radical dose homogeneity index (rDHI), and dose delivered to healthy tissue were estimated. The Kruskal-Wallis, Mann-Whitney U, and Bonferroni tests were used for statistical analysis. The ET approach showed good sparing effects and acceptable target coverage for the lower inner quadrant—superficial (LIQ-S) and lower inner quadrant—deep (LIQ-D) locations. The H-TOMO method was the least effective technique as no evaluation index achieved superiority for all tumor locations except CN. The ET method is advisable for treating LIQ-S and LIQ-D tumors, as opposed to 3D-CRT or H-TOMO, because of acceptable target coverage and much lower dose applied to surrounding tissue.

61 RADIATION PROTECTION AND DOSIMETRY↗

Exploring the Effects of Node Topology, Connectivity, and Metal Identity on the Binding of Nerve Agents and Their Hydrolysis Products in Metal–Organic Frameworks

Recent studies have shown that metal–organic frameworks (MOFs) built from hexanuclear M(IV) oxide cluster nodes are effective catalysts for nerve agent hydrolysis, where the properties of the active sites on the nodes can strongly influence the reaction energetics. The connectivity and metal identity of these M6 nodes can be easily tuned, offering extensive opportunities for computational screening to predict promising new materials. Thus, we used density functional theory (DFT) to examine the effects of node topology, connectivity, and metal identity on the binding energies of multiple nerve agents and their corresponding hydrolysis products. By computing an optimization metric based on the relative binding strengths of key hydrolysis reaction species (water, agent, and bidentate-bound products), we predicted optimal M6 nodes for hydrolyzing specific nerve agent and simulant molecules, where our results are in qualitative agreement with observed experimental trends. This analysis highlighted the notion that no single metal or node topology is optimal for all possible organophosphates, suggesting that MOFs should be selected based on the agent of interest. Using the large amount of data generated from our DFT calculations, we then derived quantitative structure–activity relationship (QSAR) models to help explain the complex trends observed in the binding energies. Through linear regression, we identified the most important descriptors for describing the binding of nerve agents and their hydrolysis products to M6 nodes. These results suggested that both molecular and node properties, including both structural and chemical features, collectively contribute to the binding energetics. By performing a thorough statistical analysis, we showed that our QSAR models are capable of making quantitatively accurate binding energy predictions for nerve agents and their hydrolysis products in a wide variety of M(IV)-MOFs. In conclusion, the insights gained herein can be used to guide future experiments for the synthesis of MOFs with enhanced catalytic activity for organophosphate hydrolysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of laser remote fusion cutting based on a mathematical model

Laser remote fusion cutting is analyzed by the aid of a semi-analytical mathematical model of the processing front. By local calculation of the energy balance between the absorbed laser beam and the heat losses, the three-dimensional vaporization front can be calculated. Based on an empirical model for the melt flow field, from a mass balance, the melt film and the melting front can be derived, however only in a simplified manner and for quasi-steady state conditions. Front waviness and multiple reflections are not modelled. The model enables to compare the similarities, differences, and limits between laser remote fusion cutting, laser remote ablation cutting, and even laser keyhole welding. In contrast to the upper part of the vaporization front, the major part only slightly varies with respect to heat flux, laser power density, absorptivity, and angle of front inclination. Statistical analysis shows that for high cutting speed, the domains of high laser power density contribute much more to the formation of the front than for low speed. The semi-analytical modelling approach offers flexibility to simplify part of the process physics while, for example, sophisticated modelling of the complex focused fibre-guided laser beam is taken into account to enable deeper analysis of the beam interaction. Mechanisms like recast layer generation, absorptivity at a wavy processing front, and melt film formation are studied too.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Estimating conditional quantiles with the help of the pinball loss

Using the so-called pinball loss for estimating conditional quantiles is a well-known tool in both statistics and machine learning. So far, however, only little work has been done to quantify the efficiency of this tool for non-parametric (modified) empirical risk minimization approaches. The goal of this work is to fill this gap by establishing inequalities that describe how close approximate pinball risk minimizers are to the corresponding conditional quantile. These inequalities, which hold under mild assumptions on the data-generating distribution, are then used to establish so-called variance bounds which recently turned out to play an important role in the statistical analysis of (modified) empirical risk minimization approaches. To illustrate the use of the established inequalities, we then use them to establish an oracle inequality for support vector machines that use the pinball loss. Here, it turns out that we obtain learning rates which are optimal in a min-max sense under some standard assumptions on the regularity of the conditional quantile function.

97 MATHEMATICS AND COMPUTING↗

Anomalous resistivity and electron heating by lower hybrid drift waves inside reconnecting current sheets

Inside an electron diffusion region of laboratory reconnection experiments, the quasi-electrostatic lower hybrid drift wave (ES-LHDW) is observed when a significant guide field component is present. Through direct measurement of the anomalous drag term and quasilinear analysis, it is shown that ES-LHDW can account for approximately 20% of the mean reconnection electric field in a case with moderate guide field. This value exceeds the contribution from classical resistivity, which is around 10%. The effects of the Lorentz force term, often neglected for electrostatic waves, are crucial for the observed correlation between electric field and density fluctuations. Anomalous electron heating by the perturbed current and resistivity (2.6 MW/m 3 ) also surpasses the classical Ohmic heating, which is about 2.0 MW/m 3 . For the case with a high guide field, significantly higher local electron temperatures were observed during periods of strong ES-LHDW activity. A statistical analysis further supports electron heating by LHDW, showing a larger increase in electron temperature with a high guide field. Finally, data from the Magnetospheric Multiscale mission provide evidence of Landau damping of ES-LHDW, suggesting that ES-LHDW may contribute to the generation of nonthermal electrons along the direction parallel to the magnetic field.

Magnetic reconnection↗

Percutaneous Renal Tumor Ablation: Radiation Exposure During Cryoablation and Radiofrequency Ablation

IntroductionOnce reserved solely for non-surgical cases, percutaneous ablation is becoming an increasingly popular treatment option for a wider array of patients with small renal masses and the radiation risk needs to be better defined as this transition continues.Materials and MethodsRetrospective review of our renal tumor ablation database revealed 425 patients who underwent percutaneous ablation for treatment of 455 renal tumors over a 5-year time period. Imparted radiation dose information was reviewed for each procedure and converted to effective patient dose and skin dose using established techniques. Statistical analysis was performed with each ablative technique.ResultsFor the 331 cryoablation procedures, the mean DLP was 6987 mGycm (SD = 2861) resulting in a mean effective dose of 104.7 mSv (SD = 43.5) and the mean CTDI{sub vol} was 558 mGy (SD = 439) resulting in a mean skin dose of 563.2 mGy (SD = 344.1). For the 124 RFA procedures, the mean DLP was 3485 mGycm (SD = 1630) resulting in a mean effective dose of 50.3 mSv (SD = 24.0) and the mean CTDI{sub vol} was 232 mGy (SD = 149) resulting in a mean skin dose of 233.2 mGy (SD = 117.4). The difference in patient radiation exposure between the two renal ablation techniques was statistically significant (p < 0.001).ConclusionBoth cryoablation and RFA imparted an average skin dose that was well below the 2 Gy deterministic threshold for appreciable sequela. Renal tumor cryoablation resulted in a mean skin and effective radiation dose more than twice that for RFA. The radiation exposure for both renal tumor ablation techniques was at the high end of the medical imaging radiation dose spectrum.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Boron neutron capture therapy (BNCT) for liver metastasis in an experimental model: dose–response at five-week follow-up based on retrospective dose assessment in individual rats

Boron neutron capture therapy (BNCT) was proposed for untreatable colorectal liver metastases. Employing an experimental model of liver metastases in rats, we recently demonstrated that BNCT mediated by boronophenylalanine (BPA-BNCT) at 13 Gy prescribed to tumor is therapeutically useful at 3-week follow-up. The aim of the present study was to evaluate dose–response at 5-week follow-up, based on retrospective dose assessment in individual rats. BDIX rats were inoculated with syngeneic colon cancer cells DHD/K12/TRb. Tumor-bearing animals were divided into three groups: BPA-BNCT (n = 19), Beam only (n = 8) and Sham (n = 7) (matched manipulation, no treatment). For each rat, neutron flux was measured in situ and boron content was measured in a pre-irradiation blood sample for retrospective individual dose assessment. For statistical analysis (ANOVA), individual data for the BPA-BNCT group were pooled according to absorbed tumor dose, BPA-BNCT I: 4.5–8.9 Gy and BPA-BNCT II: 9.2–16 Gy. At 5 weeks post-irradiation, the tumor surface area post-treatment/pre-treatment ratio was 12.2 +/- 6.6 for Sham, 7.8 +/- 4.1 for Beam only, 4.4 +/- 5.6 for BPA-BNCT I and 0.45 +/- 0.20 for BPA-BNCT II; tumor nodule weight was 750 +/- 480 mg for Sham, 960 +/- 620 mg for Beam only, 380 +/- 720 mg for BPA-BNCT I and 7.3 +/- 5.9 mg for BPA-BNCT II. The BPA-BNCT II group exhibited statistically significant tumor control with no contributory liver toxicity. Potential threshold doses for tumor response and significant tumor control were established at 6.1 and 9.2 Gy, respectively.

99 GENERAL AND MISCELLANEOUS↗

Current data are consistent with flat spatial hypersurfaces in the Λ CDM cosmological model but favor more lensing than the model predicts

Here, we study the performance of three pairs of tilted, and a pair of untilited, ΛCDM cosmological models, with three of these four pairs allowing for non-flat spatial hypersurfaces, against cosmic microwave background (CMB) temperature and polarization power spectrum data (P18), measurements of the Planck 2018 lensing potential power spectrum (lensing), and a large compilation of non-CMB data (non-CMB). For the eight models, we measure cosmological parameters and study whether or not pairs of the data sets (as well as subsets of them) are mutually consistent in these models. Half of these models allow the lensing consistency parameter A L , which re-scales the gravitational potential power spectrum, to be an additional free parameter to be determined from data, while the other three have A L = 1 which is the theoretically expected value. The pair of untilted non-flat ΛCDM models are incompatible with P18 data. The tilted spatially-flat models assume the usual primordial spatial inhomogeneity power spectrum that is a power law in wave number. The tilted non-flat models assume either the primordial power spectrum used in the Planck group anal yses [Planck P(q)], that has recently been numerically shown to be a good approximation to what is quantum-mechanically generated from a particular choice of closed inflation model initial conditions, or a recently computed power spectrum [new P(q)] that quantum-mechanically follows from a different set of non-flat inflation model initial conditions. In the tilted non-flat models with A L = 1 we find differences between P18 data and non-CMB data cosmological parameter constraints, which are large enough to rule out the Planck P(q) model at 3σ but not the new P(q) model. No significant differences are found when cosmological parameter constraints obtained with two different data sets are compared within the standard tilted flat ΛCDM model. While both P18 data and non-CMB data separately favor a closed geometry, with spatial curvature density parameter Ω k < 0, when P18+non-CMB data are jointly analyzed the evidence in favor of non-flat hypersurfaces subsides. Differences between P18 data and non-CMB data cosmological constraints subside when A L is allowed to vary. From the most restrictive P18+lensing+non-CMB data combination we get almost model-independent constraints on the cosmological parameters and find that the A L > 1 option is preferred over the Ω k < 0 one, with the A L parameter, for all models, being larger than unity by ~ 2.5σ. According to the deviance information criterion, in the P18+lensing+non-CMB analysis, the varying A L option is on the verge of being strongly favored over the A L = 1 one, which could indicate a problem for the standard tilted flat ΛCDM model. These data are consistent with flat spatial hypersurfaces but more and better data could improve the constraints on Ω k and might alter this conclusion. Error bars on some cosmological parameters are significantly reduced when non-CMB data are used jointly with P18+lensing data. For example, in the tilted flat ΛCDM model for P18+lensing+non-CMB data the Hubble constant H 0 = 68.09 ± 0.38 km s -1 Mpc -1 , which is consistent with that from a median statistics analysis of a large compilation of H 0 measurements as well as with a number of local measurements of the cosmological expansion rate. This H 0 error bar is 31% smaller than that from P18+lensing data alone.

79 ASTRONOMY AND ASTROPHYSICS↗

fuel cycle cost analysis of Th/U MOX fuel in a block-type HTR - 18619

With a rapid development of nuclear energy in these years, the supply of nuclear fuel is becoming more and more important. Thorium regains attention because of its abundant reserves and excellent physical properties. As a next generation reactor, the high temperature reactor (HTR) is a promising choice for thorium utilization because of its deeper burnup, harder spectrum and better inherent safety. Therefore, a 600 MWth 108-column modular high temperature reactor (MHR) core model with 20%UO{sub 2}-80%ThO{sub 2}; MOX fuel is adapted. A traditional two-step calculation scheme, lattice calculation then core calculation, is used to get the neutronic performance of equilibrium cycle including uranium enrichment and mass of fuel. Using these data, the fuel cycle cost of HTR can be calculated by the levelized lifetime cost method. In order to take into account the variation of unit price, a well-established, standard statistical analysis technique is used by Monte Carlo simulation, (thus, the probability distribution of fuel cycle cost can be obtained. Furthermore, sensitivity calculations are made to analyze the impact on the fuel cycle cost of variations in the unit prices for each fuel cycle component. The result shows that the most influential parameters are unit price of natural uranium, enrichment and discount rate. Finally a comparison of fuel cycle cost between 100%UO{sub 2} and 20%UO{sub 2}-80%ThO{sub 2} MOX fuel is made. The latter is 11% cheaper than the former. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗