Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

HARD X-RAY FLARE SOURCE SIZES MEASURED WITH THE RAMATY HIGH ENERGY SOLAR SPECTROSCOPIC IMAGER

Ramaty High Energy Solar Spectroscopic Imager (RHESSI) observations of 18 double hard X-ray sources seen at energies above 25 keV are analyzed to determine the spatial extent of the most compact structures evident in each case. The following four image reconstruction algorithms were used: Clean, Pixon, and two routines using visibilities-maximum entropy and forward fit (VFF). All have been adapted for this study to optimize their ability to provide reliable estimates of the sizes of the more compact sources. The source fluxes, sizes, and morphologies obtained with each method are cross-correlated and the similarities and disagreements are discussed. The full width at half-maximum (FWHM) of the major axes of the sources with assumed elliptical Gaussian shapes are generally well correlated between the four image reconstruction routines and vary between the RHESSI resolution limit of {approx}2'' up to {approx}20'' with most below 10''. The FWHM of the minor axes are generally at or just above the RHESSI limit and hence should be considered as unresolved in most cases. The orientation angles of the elliptical sources are also well correlated. These results suggest that the elongated sources are generally aligned along a flare ribbon with the minor axis perpendicular to the ribbon. This is verified for the one flare in our list with coincident Transition Region and Coronal Explorer (TRACE) images. There is evidence for significant extra flux in many of the flares in addition to the two identified compact sources, thus rendering the VFF assumption of just two Gaussians inadequate. A more realistic approximation in many cases would be of two line sources with unresolved widths. Recommendations are given for optimizing the RHESSI imaging reconstruction process to ensure that the finest possible details of the source morphology become evident and that reliable estimates can be made of the source dimensions.

07 ISOTOPE AND RADIATION SOURCES↗

THE CHANDRA LOCAL VOLUME SURVEY: THE X-RAY POINT-SOURCE CATALOG OF NGC 300

We present the source catalog of a new Chandra ACIS-I observation of NGC 300 obtained as part of the Chandra Local Volume Survey. Our 63 ks exposure covers {approx}88% of the D{sub 25} isophote (R Almost-Equal-To 6.3 kpc) and yields a catalog of 95 X-ray point sources detected at high significance to a limiting unabsorbed 0.35-8 keV luminosity of {approx}10{sup 36} erg s{sup -1}. Sources were cross-correlated with a previous XMM-Newton catalog, and we find 75 'X-ray transient candidate' sources that were detected by one observatory, but not the other. We derive an X-ray scale length of 1.7 {+-} 0.2 kpc and a recent star formation rate of 0.12 M{sub Sun} yr{sup -1} in excellent agreement with optical observations. Deep, multi-color imaging from the Hubble Space Telescope, covering {approx}32% of our Chandra field, was used to search for optical counterparts to the X-ray sources, and we have developed a new source classification scheme to determine which sources are likely X-ray binaries, supernova remnants, and background active galactic nucleus candidates. Finally, we present the X-ray luminosity functions (XLFs) at different X-ray energies, and we find the total NGC 300 X-ray point-source population to be consistent with other late-type galaxies hosting young stellar populations ({approx}< 50 Myr). We find that XLF of sources associated with older stellar populations has a steeper slope than the XLF of X-ray sources coinciding with young stellar populations, consistent with theoretical predictions.

79 ASTRONOMY AND ASTROPHYSICS↗

THE QUaD GALACTIC PLANE SURVEY. II. A COMPACT SOURCE CATALOG

We present a catalog of compact sources derived from the QUaD Galactic Plane Survey. The survey covers {approx}800 deg{sup 2} of the inner galaxy (|b| < 4{sup 0}) in Stokes I, Q, and U parameters at 100 and 150 GHz, with angular resolutions of 5 and 3.5 arcmin, respectively. Five hundred and twenty-six unique sources are identified in I, of which 239 are spatially matched between frequency bands, with 53 (234) detected at 100 (150) GHz alone; 170 sources are identified as ultracompact H II regions. Approximating the distribution of total intensity source fluxes as a power law, we find a slope of {gamma}{sub S,100} = -1.8 {+-} 0.4 at 100 GHz and {gamma}{sub S,150} = -2.2 {+-} 0.4 at 150 GHz. Similarly, the power-law index of the source two-point angular correlation function is {gamma}{sub {theta},100} = -1.21 {+-} 0.04 and {gamma}{sub {theta},150} = -1.25 {+-} 0.04. The total intensity spectral index distribution peaks at {alpha}{sub I} {approx} 0.25, indicating that dust emission is not the only source of radiation produced by these objects between 100 and 150 GHz; free-free radiation is likely significant in the 100 GHz band. Four sources are detected in polarized intensity P, of which three have matching counterparts in I. Three of the polarized sources lie close to the Galactic center, Sagittarius A*, Sagittarius B2, and the Galactic Radio Arc, while the fourth is RCW 49, a bright H II region. An extended polarized source, undetected by the source extraction algorithm on account of its {approx}0.{sup 0}5 size, is identified visually, and is an isolated example of large-scale polarized emission oriented distinctly from the bulk Galactic dust polarization.

79 ASTRONOMY AND ASTROPHYSICS↗

TG-43 U1 based dosimetric characterization of model 67-6520 Cs-137 brachytherapy source

Purpose: Brachytherapy treatment has been a cornerstone for management of various cancer sites, particularly for the treatment of gynecological malignancies. In low dose rate brachytherapy treatments, {sup 137}Cs sources have been used for several decades. A new {sup 137}Cs source design has been introduced (model 67-6520, source B3-561) by Isotope Products Laboratories (IPL) for clinical application. The goal of the present work is to implement the TG-43 U1 protocol in the characterization of the aforementioned {sup 137}Cs source. Methods: The dosimetric characteristics of the IPL {sup 137}Cs source are measured using LiF thermoluminescent dosimeters in a Solid Water phantom material and calculated using Monte Carlo simulations with the GEANT4 code in Solid Water and liquid water. The dose rate constant, radial dose function, and two-dimensional anisotropy function of this source model were obtained following the TG-43 U1 recommendations. In addition, the primary and scatter dose separation (PSS) formalism that could be used in convolution/superposition methods to calculate dose distributions around brachytherapy sources in heterogeneous media was studied. Results: The measured and calculated dose rate constants of the IPL {sup 137}Cs source in Solid Water were found to be 0.930({+-}7.3%) and 0.928({+-}2.6%) cGy h{sup -1} U{sup -1}, respectively. The agreement between these two methods was within our experimental uncertainties. The Monte Carlo calculated value in liquid water of the dose rate constant was {Lambda}=0.948({+-}2.6%) cGy h{sup -1} U{sup -1}. Similarly, the agreement between measured and calculated radial dose functions and the anisotropy functions was found to be within {+-}5%. In addition, the tabulated data that are required to characterize the source using the PSS formalism were derived. Conclusions: In this article the complete dosimetry of the newly designed {sup 137}Cs IPL source following the AAPM TG-43 U1 dosimetric protocol and the PSS formalism is provided.

07 ISOTOPE AND RADIATION SOURCES↗

Direct measurement of instantaneous source speed for a HDR brachytherapy unit using an optical fiber based detector

Purpose: Several attempts to determine the transit time of a high dose rate (HDR) brachytherapy unit have been reported in the literature with controversial results. The determination of the source speed is necessary to accurately calculate the transient dose in brachytherapy treatments. In these studies, only the average speed of the source was measured as a parameter for transit dose calculation, which does not account for the realistic movement of the source, and is therefore inaccurate for numerical simulations. The purpose of this work is to report the implementation and technical design of an optical fiber based detector to directly measure the instantaneous speed profile of a {sup 192}Ir source in a Nucletron HDR brachytherapy unit. Methods: To accomplish this task, we have developed a setup that uses the Cerenkov light induced in optical fibers as a detection signal for the radiation source moving inside the HDR catheter. As the {sup 192}Ir source travels between two optical fibers with known distance, the threshold of the induced signals are used to extract the transit time and thus the velocity. The high resolution of the detector enables the measurement of the transit time at short separation distance of the fibers, providing the instantaneous speed. Results: Accurate and high resolution speed profiles of the {sup 192}Ir radiation source traveling from the safe to the end of the catheter and between dwell positions are presented. The maximum and minimum velocities of the source were found to be 52.0{+-}1.0 and 17.3{+-}1.2 cm/s. The authors demonstrate that the radiation source follows a uniformly accelerated linear motion with acceleration of |a|=113 cm/s{sup 2}. In addition, the authors compare the average speed measured using the optical fiber detector to those obtained in the literature, showing deviation up to 265%. Conclusions: To the best of the authors' knowledge, the authors directly measured for the first time the instantaneous speed profile of a radiation source in a HDR brachytherapy unit traveling from the unit safe to the end of the catheter and between interdwell distances. The method is feasible and accurate to implement on quality assurance tests and provides a unique database for efficient computational simulations of the transient dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-19A-05: Experimental and Monte Carlo Characterization of the 1 Cm CivaString 103Pd Brachytherapy Source

Purpose: To determine the in-air azimuthal anisotropy and in-water dose distribution for the 1 cm length of the CivaString {sup 103}Pd brachytherapy source through measurements and Monte Carlo (MC) simulations. American Association of Physicists in Medicine Task Group No. 43 (TG-43) dosimetry parameters were also determined for this source. Methods: The in-air azimuthal anisotropy of the source was measured with a NaI scintillation detector and simulated with the MCNP5 radiation transport code. Measured and simulated results were normalized to their respective mean values and compared. The TG-43 dose-rate constant, line-source radial dose function, and 2D anisotropy function for this source were determined from LiF:Mg,Ti thermoluminescent dosimeter (TLD) measurements and MC simulations. The impact of {sup 103}Pd well-loading variability on the in-water dose distribution was investigated using MC simulations by comparing the dose distribution for a source model with four wells of equal strength to that for a source model with strengths increased by 1% for two of the four wells. Results: NaI scintillation detector measurements and MC simulations of the in-air azimuthal anisotropy showed that ≥95% of the normalized data were within 1.2% of the mean value. TLD measurements and MC simulations of the TG-43 dose-rate constant, line-source radial dose function, and 2D anisotropy function agreed to within the experimental TLD uncertainties (k=2). MC simulations showed that a 1% variability in {sup 103}Pd well-loading resulted in changes of <0.1%, <0.1%, and <0.3% in the TG-43 dose-rate constant, radial dose distribution, and polar dose distribution, respectively. Conclusion: The CivaString source has a high degree of azimuthal symmetry as indicated by the NaI scintillation detector measurements and MC simulations of the in-air azimuthal anisotropy. TG-43 dosimetry parameters for this source were determined from TLD measurements and MC simulations. {sup 103}Pd well-loading variability results in minimal variations in the in-water dose distribution according to MC simulations. This work was partially supported by CivaTech Oncology, Inc. through an educational grant for Joshua Reed, John Micka, Wesley Culberson, and Larry DeWerd and through research support for Mark Rivard.

07 ISOTOPE AND RADIATION SOURCES↗

Source strength verification and quality assurance of preloaded brachytherapy needles using a CMOS flat panel detector

Purpose: Current methods of low dose rate brachytherapy source strength verification for sources preloaded into needles consist of either assaying a small number of seeds from a separate sample belonging to the same lot used to load the needles or performing batch assays of a subset of the preloaded seed trains. Both of these methods are cumbersome and have the limitations inherent to sampling. The purpose of this work was to investigate an alternative approach that uses an image-based, autoradiographic system capable of the rapid and complete assay of all sources without compromising sterility. Methods: The system consists of a flat panel image detector, an autoclavable needle holder, and software to analyze the detected signals. The needle holder was designed to maintain a fixed vertical spacing between the needles and the image detector, and to collimate the emissions from each seed. It also provides a sterile barrier between the needles and the imager. The image detector has a sufficiently large image capture area to allow several needles to be analyzed simultaneously.Several tests were performed to assess the accuracy and reproducibility of source strengths obtained using this system. Three different seed models (Oncura 6711 and 9011 {sup 125}I seeds, and IsoAid Advantage {sup 103}Pd seeds) were used in the evaluations. Seeds were loaded into trains with at least 1 cm spacing. Results: Using our system, it was possible to obtain linear calibration curves with coverage factor k = 1 prediction intervals of less than ±2% near the centre of their range for the three source models. The uncertainty budget calculated from a combination of type A and type B estimates of potential sources of error was somewhat larger, yielding (k = 1) combined uncertainties for individual seed readings of 6.2% for {sup 125}I 6711 seeds, 4.7% for {sup 125}I 9011 seeds, and 11.0% for Advantage {sup 103}Pd seeds. Conclusions: This study showed that a flat panel detector dosimetry system is a viable option for source strength verification in preloaded needles, as it is capable of measuring all of the sources intended for implantation. Such a system has the potential to directly and efficiently estimate individual source strengths, the overall mean source strength, and the positions within the seed-spacer train.

60 APPLIED LIFE SCIENCES↗

Assessment of Contribution of Contemporary Carbon Sources to Size-Fractionated Particulate Matter and Time-Resolved Bulk Particulate Matter Using the Measurement of Radiocarbon

This study was motivated by a desire to improve understanding of the sources contributing to the carbon that is an important component of airborne particulate matter (PM). The ultimate goal of this project was to lay a ground work for future tools that might be easily implemented with archived or routinely collected samples. A key feature of this study was application of radiocarbon measurement that can be interpreted to indicate the relative contributions from fossil and non-fossil carbon sources of atmospheric PM. Size-resolved PM and time-resolved PM{sub 10} collected from a site in Sacramento, CA in November 2007 (Phase I) and March 2008 (Phase II) were analyzed for radiocarbon and source markers such as levoglucosan, cholesterol, and elemental carbon. Radiocarbon data indicates that the contributions of non-fossil carbon sources were much greater than that from fossil carbon sources in all samples. Radiocarbon and source marker measurements confirm that a greater contribution of non-fossil carbon sources in Phase I samples was highly likely due to residential wood combustion. The present study proves that measurement of radiocarbon and source markers can be readily applied to archived or routinely collected samples for better characterization of PM sources. More accurate source apportionment will support ARB in developing more efficient control strategies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calculation of Ambient (H*(10)) and Personal (H p (10)) Dose Equivalent from a 252 Cf Neutron Source

The neutron emission rate from radioisotope neutron sources such as 252 Cf sources can be calibrated by the National Institute of Standards and Technology (NIST) by the manganous sulfite bath method. This calibration method does not compute the dose or dose equivalent rate from the source. Because there is no accepted transfer standard for neutron dose measurements, secondary calibration facilities are responsible for determining their own neutron dose factors. This report describes a neutron source and irradiation apparatus in use at the Pacific Northwest National Laboratory Calibration Facility. The neutron source is a SR-Cf-3000 design 252 Cf neutron source. The neutron source is contained in an aluminum transfer capsule that is used to transport the neutron source between its storage location and it’s irradiation location. During irradiations, the source is located in a transfer tube assembly that consists of two concentric aluminum tubes. When moderated neutrons are desired, the transfer tube assembly is surrounded by a sphere that is filled with D 2 O as a moderating medium. Ambient dose equivalent (H*(10)) and Personal dose equivalent (H p (10)) dose rates and dose conversion factors were calculated for moderated and unmoderated neutron spectra based on the data provided in ICRP Publication 74. The neutron fluence-to-dose-equivalent conversion factors calculated for this report are summarized and compared to published values in Table 47. The calculated coefficients for the unmoderated 252 Cf spectra agree very well with published reference values, within about 2%. The calculated coefficients for the D 2 O moderated 252 Cf spectra, however, differ from published reference values by about 22%. The PNNL coefficients are higher than the published values which could be interpreted to mean that the PNNL D 2 O moderated spectrum is harder, i.e. higher average energy, than the spectrum published by the ISO (2000), which formed the basis for the published coefficients. The D 2 O moderating sphere in use at PNNL contains less D 2 O moderator than did the D 2 O moderating sphere that was used to calculate the ISO spectrum and this is the likely reason for much of the spectral differences. The exact location of the 252 Cf activity in the source encapsulation is unknown. Preliminary measurements, not described in this report, indicate that the activity may be offset from the location that has been assumed in the past. Corrections for the offset are being proposed and will be the subject of another report. This report was written in a calculation package format to help meet various Quality Assurance requirements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Next-Generation Photon Sources for Grand Challenges in Science and Energy

The next generation of sustainable energy technologies will revolve around transformational new materials and chemical processes that convert energy efficiently among photons, electrons, and chemical bonds. New materials that tap sunlight, store electricity, or make fuel from splitting water or recycling carbon dioxide will need to be much smarter and more functional than today's commodity-based energy materials. To control and catalyze chemical reactions or to convert a solar photon to an electron requires coordination of multiple steps, each carried out by customized materials and interfaces with designed nanoscale structures. Such advanced materials are not found in nature the way we find fossil fuels; they must be designed and fabricated to exacting standards, using principles revealed by basic science. Success in this endeavor requires probing, and ultimately controlling, the interactions among photons, electrons, and chemical bonds on their natural length and time scales. Control science - the application of knowledge at the frontier of science to control phenomena and create new functionality - realized through the next generation of ultraviolet and X-ray photon sources, has the potential to be transformational for the life sciences and information technology, as well as for sustainable energy. Current synchrotron-based light sources have revolutionized macromolecular crystallography. The insights thus obtained are largely in the domain of static structure. The opportunity is for next generation light sources to extend these insights to the control of dynamic phenomena through ultrafast pump-probe experiments, time-resolved coherent imaging, and high-resolution spectroscopic imaging. Similarly, control of spin and charge degrees of freedom in complex functional materials has the potential not only to reveal the fundamental mechanisms of high-temperature superconductivity, but also to lay the foundation for future generations of information science. This report identifies two aspects of energy science in which next-generation ultraviolet and X-ray light sources will have the deepest and broadest impact: (1) The temporal evolution of electrons, spins, atoms, and chemical reactions, down to the femtosecond time scale. (2) Spectroscopic and structural imaging of nano objects (or nanoscale regions of inhomogeneous materials) with nanometer spatial resolution and ultimate spectral resolution. The dual advances of temporal and spatial resolution promised by fourth-generation light sources ideally match the challenges of control science. Femtosecond time resolution has opened completely new territory where atomic motion can be followed in real time and electronic excitations and decay processes can be followed over time. Coherent imaging with short-wavelength radiation will make it possible to access the nanometer length scale, where intrinsic quantum behavior becomes dominant. Performing spectroscopy on individual nanometer-scale objects rather than on conglomerates will eliminate the blurring of the energy levels induced by particle size and shape distributions and reveal the energetics of single functional units. Energy resolution limited only by the uncertainty relation is enabled by these advances. Current storage-ring-based light sources and their incremental enhancements cannot meet the need for femtosecond time resolution, nanometer spatial resolution, intrinsic energy resolution, full coherence over energy ranges up to hard X-rays, and peak brilliance required to enable the new science outlined in this report. In fact, the new, unexplored territory is so expansive that no single currently imagined light source technology can fulfill the whole potential. Both technological and economic challenges require resolution as we move forward. For example, femtosecond time resolution and high peak brilliance are required for following chemical reactions in real time, but lower peak brilliance and high repetition rate are needed to avoid radiation damage in high-resolution spatial imaging and to avoid space-charge broadening in photoelectron spectroscopy and microscopy. But light sources alone are not enough. The photons produced by next-generation light sources must be measured by state-of-the-art experiments installed at fully equipped end stations. Sophisticated detectors with unprecedented spatial, temporal, and spectral resolution must be designed and created. The theory of ultrafast phenomena that have never before been observed must be developed and implemented. Enormous data sets of diffracted signals in reciprocal space and across wide energy ranges must be collected and analyzed in real time so that they can guide the ongoing experiments. These experimental challenges - end stations, detectors, sophisticated experiments, theory, and data handling - must be planned and provided for as part of the photon source.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

New Identifications and Multiwavelength Properties of Extragalactic Fermi Gamma-Ray Sources in the SPT-SZ Survey Field

he fourth Fermi Large Area Telescope catalog (4FGL) contains 5064 $\ γ$-ray sources detected at high significance, but 26% of them still lack associations at other wavelengths. The SPT-SZ survey, conducted between 2008 and 2011 with the South Pole Telescope (SPT), covers 2500 deg 2 of the southern sky in three millimeter-wavelength (mm) bands and was used to construct a catalog of nearly 5000 emissive sources. In this study, we introduce a new cross-matching scheme to search for multiwavelength counterparts of extragalactic $\ γ$-ray sources using a mm catalog. We apply a Poissonian probability to evaluate the rate of spurious false associations and compare the multiwavelength associations from the radio, mm, near-infrared, and X-ray with 4FGL $\ γ$-ray sources. In the SPT-SZ survey field, 85% of 4FGL sources are associated with mm counterparts. These mm sources include 94% of previously associated 4FGL sources and 56% of previously unassociated 4FGL sources. The latter group contains 40 4FGL sources for which SPT has provided the first identified counterparts. Nearly all of the SPT-associated 4FGL sources can be described as flat-spectrum radio quasars or blazars. We find that the mm band is the most efficient wavelength for detecting $\ γ$-ray blazars when considering both completeness and purity. We also demonstrate that the mm band correlates better to the $\ γ$-ray band than the radio or X-ray bands. With the next generation of CMB experiments, this technique can be extended to greater sensitivities and more sky area to further complete the identifications of the remaining unknown $\ γ$-ray blazars.

79 ASTRONOMY AND ASTROPHYSICS↗

The Solid Angle for a Spherical Surface Source and a Detector with an Arbitrary Aperture: An Elegant Proof

It has previously been proven that the solid angle (or geometry factor, also called the geometrical efficiency) for a spherically symmetric outward-directed surface source with an arbitrary radius and polar angle distribution and an arbitrary detector aperture is equal to the solid angle for an isotropic point source located at the center of the spherical surface source and the same detector aperture. The solid angle for a source-detector system is the fraction of source particles that enter the detector aperture and so it is not purely geometric-the angular distribution of the source is a factor. The previous proof relied on an analytic transport-theory (streaming only) calculation of the solid angle Ω for a spherically symmetric surface source and a point detector. In this paper, a new, more elegant proof is given. Since the net current across any portion of a plane that intersects the center of a spherical surface source is zero, the solid angle for a spherical surface source with any polar angle distribution and a uniform azimuthal angle distribution and any detector aperture is equal to the solid angle for an isotropic point source and the same detector. This insight obviates the calculus and trigonometry involved in the previous proof. (author)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sealed source peer review plan

Sealed sources are known quantities of radioactive materials that have been encapsulated in quantities that produce known radiation fields. Sealed sources have multiple uses ranging from instrument calibration sources to sources that produce radiation fields for experimental applications. The Off-Site Source Recovery (OSR) Project at Los Alamos National Laboratory (LANL), created in 1999, under the direction of the Waste Management Division of the U.S. Department of Energy (DOE) Albuquerque has been assigned the responsibility to recover and manage excess and unwanted radioactive sealed sources from the public and private sector. LANL intends to ship drums containing qualified sealed sources to the Waste Isolation Pilot Plant (WIPP) for disposal. Prior to shipping, these drums must be characterized with respect to radiological content and other parameters. The U. S. Environmental Protection Agency (EPA) requires that ten radionulcides be quantified and reported for every container of waste to be disposed in the WIPP. The methods traditionally approved by the EPA include non-destructive assay (NDA) in accordance with Appendix A of the Contact-Handled Transuranic Waste Acceptance Criteria for the Waste Isolation Pilot Plant (DOE, 2002) (CH WAC). However, because of the nature and pedigree of historical records for sealed sources and the technical infeasibility of performing NDA on these sources, LANL proposes to characterize the content of these waste drums using qualified existing radiological data in lieu of direct measurement. This plan describes the process and documentation requirements for the use of the peer review process to qualify existing data for sealed radiological sources in lieu of perfonning radioassay. The peer review process will be performed in accordance with criteria provided in 40 CFR {section} 194.22 which specifies the use of the NUREG 1297 guidelines. The plan defines the management approach, resources, schedule, and technical requirements for the subject peer review.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Event reconstruction for line source releases

The goal of source inversion, also called event reconstruction, is the calculation of source parameters from information obtained by network of concentration (or dosage) and meteorological sensors. Source parameters include source location and strength, but in certain cases there could be more than one source so the inversion procedure could deal with determination of number of sources, as well. In a case of limited time period pollutant emission events, as for example during accidents or intentional releases, it is of great use to estimate starting and ending times of the event. This kind of research is very useful for estimating the source parameters of industrial pollutants since it provides important information for regulation purposes. Also it provides information to fast responders in a case of accidental pollutant releases or for homeland security needs when chemical, biological or radiological agent is deliberately released. Development of faster and more accurate algorithms is very important since it could help reduce the populace's exposure to dangerous airborne contaminants, plan evacuation routes, and help assess the magnitude of clean up. During the last decade, the large number of research papers in area of source inversion was published where many different approaches were used. Most of the source inversion work publish to date apply to point source releases. The forward dispersion models used range from fast Gaussian plume and puff codes that enable almost instantaneous calculations of concentrations and dosages to Computational Fluid Dynamics (CFD) codes that provide more detailed and precise calculation but at the same time are expensive with respect to time and computer resources. The optimization methods were often used and examples are simulated annealing and genetic algorithms.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Evaluation of Anodized and Electroplated Radioactive Check Sources for Radiological Monitoring Instruments

Radioactive check sources are often used for source checking calibrated instruments to confirm accurate readings are obtained from radiological monitoring instruments. Because of the importance of check sources and their application, PNNL conducted a study to evaluate the effectiveness and accuracy of active sources produced using different construction methods. Eleven, randomly selected check sources of both anodized (five) and electroplated (six) construction were evaluated, along with their calculated decay curves, to determine how well they withstand consistent, multi-year use in the field. Results show that the anodized and electroplated check sources evaluated hold up well enough to continue their use, regardless of wear and tear sustained over years of use. This report provides the source information, empirical data for the 11 anodized and electroplated check sources and their representative decay curves, and it documents the conclusion that anodized and electroplated check sources are reliable for routine use in the field over multiple years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Two Extraordinary AmLi Neutron Sources

Two legacy AmLi sources, MRC-101 and MRC-103, are routinely used for neutron detector characterization and testing campaigns that Pacific Northwest National Laboratory manages for the Defense Threat Reduction Agency within the U.S. Department of Defense. However, applicability of source measurement data has been substantially limited due to the lack of original manufacturer documentation and cross comparison to other sources. This paper summarizes results of the measurement campaign conducted to better quantify source radionuclide content, neutron energy spectrum and emission rate of the AmLi sources. The source characterization study consisted of three major consecutive measurement exercises. First, gamma spectrometry measurements using a high purity germanium detector were used to estimate the radionuclide content and potential impurities of the AmLi sources. Then neutron spectral measurements were taken to determine the unique neutron energy distribution. Finally, assessments of the total neutron yields of the sources were made with measurements in a neutron well counter. The neutron detection efficiency for these measurements was determined via detailed Monte Carlo modeling based on the neutron energy distribution measured with the rotating neutron spectrometer. The most exciting and unexpected finding of the study was a significant contamination of the source material with beryllium, contributing up to 17% to the total neutron emission rate and correspondingly changing the neutron energy spectrum. Also, the obtained lithium-only portion of the measured energy distribution of the sources was compared against several AmLi spectra previously reported by different researchers.

AWCC, AmLi, beryllium contamination, neutron spect↗

Influence of background sources and topographic resolution in the Weather Research and Forecasting Model on xenon plume characteristics at monitoring stations

For many atmospheric monitoring applications, networks of measurement sites—such as the radionuclide stations of the International Monitoring System—can be sparse. With measurement locations potentially hundreds to thousands of kilometers from a release it is important to quantify the effects of physical processes on transport and dispersion of plumes between source and measurement locations. This study addresses the effects of background sources and topography resolution near the release location of radionuclides. We use the Weather Research and Forecasting (WRF) model with inline chemistry to investigate (1) how an additional, time-varying source of 133 Xe, such as an operational medical isotope production facility, contributes to activity concentration measurements at monitoring sites, and (2) how complex topography influences on atmospheric conditions near emission sources impact plume concentrations at varying distances from the source. Two 133 Xe emission sources, including (1) a high flux rate of short duration representing an explosive event, and (2) a variable and continuous background source, are simulated. The continuous background source contributes significantly to total 133 Xe concentrations at several monitoring stations. Further, a WRF simulation at 9 km horizontal resolution is compared with a nested grid simulation, where the innermost domain has a resolution of 1 km. Increased topographic resolution leads to an improved representation of plume responses to local winds, with topographic influences greatest at locations closest to the sources. Differences between the two domain resolutions decrease at greater distances from the sources, as plumes have time to spread and mix and are influenced by synoptic scale circulation patterns that are represented similarly in both simulations.

54 ENVIRONMENTAL SCIENCES↗

Configuration and impurity quantification of AmLi sources using radiography and gamma spectroscopy

This paper presents the non-destructive assay of two AmLi sources used for detector characterization and active interrogation at PNNL, identified as MRC-101 and MRC-103. First, a detailed description of the internal configuration of 2724-BT encapsulated MRC sources is established. X-ray radiographs of the AmLi sources are reported for the first time to verify the dimensions and orientation of the encapsulation. Notably, a density variation was observed as a contrast change across the height of the source cavities. Contrary to commonly made assumptions in literature, it is indirectly observed that the AmLi source/target material only occupies a portion of the source cavity. The intensity of the prompt gamma-rays resulting from the inelastic scatter of alpha particles on 7Li was used to calculate the mass ratios of LiH:AmO2. The gamma-ray spectra revealed the presence of numerous impurities in both source and target material (243Am, 237Np, 154Eu, 23Na, and 9Be). Neutron-gamma production ratios were applied to the intensity of the Doppler-broadened peaks from alpha-induced reactions with 7Li, 9Be, and 23Na to calculate neutron rates for both sources. A neutron/alpha production yield (derived in this work) was then related to the atomic concentration of these isotopes to find the approximate masses within each source. Ultimately, the AmLi source density was estimated with prompt gamma analysis based on partial source volumes as 0.45±0.08 g/cm^3.

DTRA, AmLi, neutron↗