Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “solar panel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Diagonal Shadows Could Cause Arcs in Thin-Film Modules With P4 Scribes

Thin-film photovoltaic (PV) modules are often made using monolithic integration (MLI), regardless of absorber technology. MLI modules sometimes use a fourth pattern of scribe lines, P4, to divide modules into parallel substrings of cells. We simulated diagonal shadows in such modules and show that they cause a voltage difference across P4. This voltage can be enough to cause an arc across P4. An arc inside a PV module can cause burned polymers and broken glass. Such packaging failures create a risk of fire or electric shock in any PV module. These hazards go beyond the permanent loss of efficiency that vertical shadows can cause. Here, we propose several solutions to this potential problem.

14 SOLAR ENERGY↗

Fill Factor Loss in Fielded Photovoltaic Modules Due to Metallization Failures, Characterized by Luminescence and Thermal Imaging

Understanding the causes of photovoltaic module failure in the field can be achieved using spatially-resolved imaging tools in combination with current-voltage (IV) characterization. We evaluate 23 field-degraded modules by comparing their IV characteristics with module images obtained by electroluminescence, photoluminescence, UV-fluorescence, and dark lock-in thermography. We identify primarily metallization failures (metallization series resistance, solder point heating, broken fingers, disrupted interconnects) in these modules that has led to a severe drop in the fill factor and up to 35% power loss over only 2 years of deployment.

14 SOLAR ENERGY↗

Numerical Validation of an Algorithm for Combined Soiling and Degradation Analysis of Photovoltaic Systems

We describe and demonstrate an open-source algorithm for simultaneously quantifying degradation and soiling of photovoltaic (PV) systems from energy-production time series data. The new analysis is based on year-on-year degradation rate analysis combined with stochastic rate and recovery soiling analysis. The algorithm is designed to fit into the workflow provided by RdTools, a Python module maintained by NREL and collaboratively developed with the community, which provides a framework and functions for degradation and loss-factor analysis of PV field data. We demonstrate the method on numerically simulated PV data sets and show that it reduces the root-mean-square error of the P50 degradation rate estimate when soiling is present.

14 SOLAR ENERGY↗

UV-Fluorescence Imaging of Silicon PV Modules After Outdoor Aging and Accelerated Stress Testing

Fast, non-destructive, outdoor-compatible methods for photovoltaic module characterization are essential for monitoring module quality without disrupting energy production. UV-fluorescence (UVF) imaging of the encapsulant layer can be used for crack detection in the field. We show that UVF patterns vary widely between modules and types of applied stress. We propose that combining accelerated stress testing (e.g. thermal cycling and damp heat) with field investigations can help build understanding of different types of UVF, which are formed and subsequently quenched at varying rates. Ultimately, such understanding could enable estimating when cracks were formed.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Luminescence and Thermal Imaging Applied to Half-Cut-Cell and Emitter-Wrap-Through-Cell Modules

Imaging techniques provide spatial details and visualization of module defects and degradation mechanisms that affect energy conversion efficiency and performance. We apply photoluminescence, electroluminescence, and dark lock-in thermography imaging techniques to evaluate new modules in their initial state and after applying stresses of damp heat, light-induced-degradation regeneration parameters, thermal cycling, and humidity-freeze cycles. One module uses emitter-wrap-through cells with back contacts connected to a metal-foil backplane, and the other is composed of half-cut cells. Imaging shows examples on non-uniform degradation and damage such as cells that degrade and recover under the applied conditions, cells with cracks and handling damage, and cells with increasing series resistance.

degradation↗

Cracked Gridline Wear Out Follows a Power Law

Cracks can form in Silicon solar cells in photovoltaic modules due to mechanical stresses arising from various extrinsic factors like handling and weather. While the immediate performance degradation may be minor, continuous loading overtime will degrade module performance. One probable reason is gridline surface wear across the cracked silicon with increased cyclic loading. In this work we propose a method to correlate gridline wear to module electrical degradation. We begin by conducting cyclic four-point bending tests on laminated silicon solar cells with a single crack and 22 intact gridlines for 10,000 cycles. We measure the progressive change in resistance during each loading cycle. We correlate it to a length scale called critical crack opening displacement (CCOD) that signifies failure of individual gridlines. By employing Weibull analysis, we determine the characteristic CCOD for all cycles and fit this data to a modified version of a wear power law. We observe that this i ts the data well. We also propose to study the effect of individual parameters in the power law equation and extend the equation to include material properties.

bending↗

Recovery of Glass and Silicon Solar Cells from Si-Modules Through Laser Processing

This study demonstrates an innovative and environmentally friendly laser-based approach for the efficient recovery of glass and silicon solar cells, allowing the recycling of photovoltaic modules. The methodology involves the use of a high-power pulsed laser beam focusing at various interfaces within the modules. Specifically, the delivery of ultra-short pulse laser energy at the interfaces of glass and polymeric encapsulants, as well as at the encapsulants and silicon solar cells, facilitates the debonding of polymers from both glass and silicon cell surfaces. The debonding occurs through photothermal, ablation, chemical modification, and localized heat generation. The research successfully demonstrates the recovery of glass from commercial mini solar modules of size 11.5 x 6.8 cm 2 and a silicon wafer of size 3.0x1.6 cm 2 . Ongoing efforts aim to extend the effectiveness of this laser-based methodology to comprehensively recycle larger-size components. This innovative approach holds promise for addressing environmental concerns associated with the disposal of solar modules, contributing to sustainable practices in the renewable energy sector.

glass↗

NH 4 OH Looping with Membrane CO 2 Absorber and Distributed Stripper for Enhanced Algae Growth

The University of Kentucky Center for Applied Energy (UK CAER) has devised a unique, integrated CO2 capture and utilization technology. CO2 from coal-fired power generation flue gas is first captured at half the operating cost of a typical aqueous CO2 capture system (CCS), distributed in an aqueous stream and then fixed by algae in bioreactors where the algae production is increased by 50% over that with a typical intermittent nutrient feeding system. Lower CCS operating cost is achieved by eliminating the flue gas pretreatment step for cooling and SO2 removal, eliminating steam extraction from the power generation steam cycle for solvent regeneration, and eliminating CO2 compression. Higher algae production is achieved by continuous, just-in-time nutrient feed to the bioreactors directly from a distributed solvent regenerator, which maintains the bioreactor pH for optimum growth. The process starts with a uniquely configured membrane absorber, where the flue gas is indirectly contacted with an ammonium hydroxide (NH4OH) solvent. Dissolved NH3 is attractive for both CO2 capture and as an algae nutrient. For CO2 capture it is inexpensive, has a low regeneration energy, is thermally- and oxidatively-stable and has a viscosity near that of water, which makes is easy to transport. Numerous studies have shown that the scrubbing capacity of NH3 is approximately 0.9-1.2 kg of CO2/kg of NH3, with a CO2 removal efficiency of ~99% and half the solvent regeneration energy than that of 30 wt% MEA[1, 2, 3]. NH3 is attractive as an algae nutrient due to its low cost. The rich NH4OH solvent is pumped to a set of distributed regenerators which are co-located with the algae bioreactors. Solvent pumping, transport and distribution reduces the balance of plant (BOP) cost compared to a typical aqueous CCS related to the flue gas duct and boost fan required to transport the flue gas. The energy required for the distributed solvent regeneration is supplied by solar-thermal panels eliminating the need for steam extraction from the power generation steam cycle. After solvent regeneration, the product stream contains both the CO2 captured from the flue gas and volatized NH3 from the solvent. This product stream is fed directly to the bioreactors, eliminating the need for compression of the CO2 stream. The relative amounts of CO2 and NH3 in the product stream are adjusted and controlled by a controlling the regeneration conditions (pressure and temperature). The continuous feed of the right ratio of nutrients overcomes the typical inhibition of algae growth resulting from frequent pH swings in the bioreactor due to unbalanced (intermittent) feeding systems for CO2 and N. Also, because the regenerators will operate at pressure and be located in close proximity to the bioreactors, there is no worry about pressure drop when sparging the gas into the algae. Sparging produces small bubbles which is beneficial for mass transfer efficiency. One known challenge when using an NH4OH solvent is high NH3 emission. Hydrophobic membranes are used for CO2 capture using an aqueous NH3 solution[4, 5] without the direct contact between flue gas and aqueous solution. Additionally, UK CAER CO2 capture and utilization process manages NH3 slip in three extra measures. First, NH3 slip is minimized by working with minimal species partial pressure, which is proportional to the concentration in the liquid. Hence, lowering the capture solvent concentration will lower the NH3 partial pressure. Second, UK CAER’s previous work has demonstrated that the addition of Zn2+ into NH3 solutions to chelate the NH3 can reduce NH3 volatility. Third, the configuration of the membrane CO2 absorber utilizes condensed water from the flue gas to continually wash the gas-side of the membrane to reduce fouling and recapture NH3 slip. Additional details about the UK CAER unique, integrated CO2 capture and utilization technology will be presented along with technology development plans. Diao, N., Q. Li, and Z. Fang. 2004. Heat transfer in ground heat exchangers with groundwater advection. International Journal of Thermal Sciences. 43: 1203-1211, He, Q., M. Chen, L. Meng, K. Liu, and W. Pan. 2004. Study on Carbon Dioxide Removal from Flue Gas by Absorption of Aqueous Ammonia. Western Kentucky University. Yeh, A.C., and H. Bai. 1999. Comparison of ammonia and monoethanolamine solvents to reduce CO2 greenhouse gas emissions. The Science of the Total Environment. 228: 121-133, Villeneuve, K., D. Roizard, J.C. Remigy, M. Iacono, and S. Rode. 2018. CO2 capture by aqueous ammonia with hollow fiber membrane contactors: Gas phase reactions and performance stability. Separation and Purification Technology, 199: 189-197, Toro Molina, C., and C. Bouallou. 2016. Carbon dioxide absorption by ammonia intensified with membrane contactors. Clean Techn Environ Policy 18, 2133–2146 (2016)

20 FOSSIL-FUELED POWER PLANTS↗

Remanufacturable "Net-Zero Pb" Perovskite Solar Modules

Our introduced a low-cost recycling method for perovskite PV cells which utilize KI salt-based solvents, a more sustainable chemical compared to commonly used chemicals such as DMF, chlorobenzene etc. All steps of the recycling method were demonstrated in detail in publications and presentations of the team. In addition, the techno-economic team demonstrated that the KI-based method is a more promising option compared to other methods investigated in the literature.

14 SOLAR ENERGY↗

PV Lifetime Project (2024 NREL Annual Report)

DOE’s PV Lifetime project was initiated in 2016 with the goal of accurately characterizing the early-life evolution of photovoltaic (PV) field performance. Different PV cell and module technologies result in different initial degradation rates due to effects like light-induced degradation (LID) and light & elevated temperature-induced degradation (LeTID). To accurately characterize the initial field degradation of maximum power (Pmp) requires the use of high-accuracy indoor IV curve measurements at standard test conditions. Therefore, PV modules involved in this study are removed from the field once or twice per year and brought indoors for measurement under constant temperature and irradiance conditions.

14 SOLAR ENERGY↗

Carbondale Community Geothermal Coalition – Replicable Models for Decarbonizing Mixed-Use Rural Communities

The Carbondale Community Geothermal Coalition (CCGC) set out to prove that a fifth-generation geothermal district heating & cooling (5G GDHC) network can be technically feasible, cost-effective, and socially equitable for a small, mixed-use rural community. During Budget Period 1 (Planning & Design) the team: ● Completed a 449 ft thermal-response test confirming excellent ground conductivity (k = 1.69 Btu ft -1 hr -1 °F -1 ) and a benign 56.3 °F undisturbed temperature. Page 1 Final Technical Report for Award Number: DE-EE0010663 ● Built a fully calibrated digital twin (URBANopt → Modelica) for 240 k ft 2 of existing + future buildings. ● Designed a 75-borehole ambient-temperature loop (ATL) augmented by 75 solar-thermal panels, supplying 44 % of district heating and 100 % cooling in Stage-1. ● Produced retrofit bid-ready drawings for the Third Street Center and Second Street Townhomes. ● Reached > 200 community stakeholders and exceeded equity targets (46 % Hispanic/Latinx participation). ● Drafted a multi-tiered workforce plan aligned with Colorado Mountain College (Hispanic Serving Institution) and IGSHPA certifications.

15 GEOTHERMAL ENERGY↗

High-temperature annealable solar array.

Bonded solderless solar cell panel prototype withstanding high annealing temperature and thermal shock without electrical or mechanical degradation

Clarke, D. R.↗

Solar energy research and utilization

The role is described that solar energy will play in the heating and cooling of buildings, the production of renewable gaseous, liquid and solid fuels, and the production of electric power over the next 45 years. Potential impacts on the various energy markets and estimated costs of such systems are discussed along with illustrations of some of the processes to accomplish the goals. The conclusions of the NSF/NASA Solar Energy Panel (1972) are given along with the estimated costs to accomplish the 15 year recommended program and also the recent and near future budget appropriations and recommendations are included.

Cherry, W. R.↗

Modular test system for solar collectors

Portable, recirculating-water-flow, and temperature-control device is used with solar simulator and actual sunlight to test and evaluate several solar-collector panel coatings, panel designs, and scaled-down collector subsystems. System can be pressurized to prevent boiling and allows operation above 100 degrees Centigrade.

Dolan, F. J.↗