Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sheaths”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Ionospheric Measurements Using Environmental Sampling Techniques

Two rockets were flown to peak altitudes of 220 km in September 1959 to test various methods planned for future measurements of ionization parameters in the ionosphere, exosphere, and interplanetary plasma. The experiments used techniques which sample the ambient environment in the immediate vicinity of the research vehicle. Direct methods were chosen since indirect propagation techniques do not provide the temperatures of charged particles, are insensitive to ion densities, and cannot measure local electron densities under all conditions. Very encouraging results have been obtained from a preliminary analysis of data provided by one of the two flights. A new rf probe technique was successfully used to determine the electron density profile. This was indicated by its agreement with the results of a companion cw propagation experiment, particularly when the probe data were corrected for the effects of the ion sheath which surrounds the vehicle. The characteristics of this sheath were determined directly in flight by an electric field meter which provided the sheath field, and by a Langmuir probe which measured the total potential across the sheath. The electron temperatures deduced from the Langmuir probe data are greater than the neutral gas temperatures previously measured for the same location and season, but these measurements possibly were taken under different atmospheric conditions. Ion densities were calculated from the ion trap data for several altitudes ranging from 130 to 210 km and were found to be within 20 percent of the measured electron densities.

Bourdeau, R. E.↗

Dusty Plasma Dynamics Near Surfaces in Space

The investigation 'Dusty Plasma Dynamics Near Surfaces in Space' is an experimental and theoretical study of the dynamics of dust particles on airless bodies in the solar system in the presence of a photoelectron sheath generated by solar ultraviolet light impinging on the surface. Solar UV illumination of natural and manmade surfaces in space produces photoelectrons which form a plasma sheath near the surface. Dust particles on the surface acquire a charge and may be transported by electric fields in the photoelectron sheath generated by inhomogeneities in the surface or the illumination (such as shadows). The sheath itself has a finite vertical extent leading to (at least) an electric field normal to the illuminated surface. If dust particles are launched from the surface by some other process, such as meteoroid impact, or spacecraft activity on the surface, these grains become charged and move under the influence of gravity and the electric field. This can give rise to suspension of the particles above the surface, loss from the parent body entirely (if accelerated beyond escape velocity), and a different distribution of dust ejecta from what would be expected with purely gravitational dynamics.

Colwell, Joshua E.↗

Fiber optic attenuator

A fiber optic attenuator of the invention is a mandrel structure through which a bundle of optical fibers is wrapped around in a complete circle. The mandrel structure includes a flexible cylindrical sheath through which the bundle passes. A set screw on the mandrel structure impacts one side of the sheath against two posts on the opposite side of the sheath. By rotating the screw, the sheath is deformed to extend partially between the two posts, bending the fiber optic bundle to a small radius controlled by rotating the set screw. Bending the fiber optic bundle to a small radius causes light in each optical fiber to be lost in the cladding, the amount depending upon the radius about which the bundle is bent.

Buzzetti, Mike F.↗

In vivo electrode implanting system

A cylindrical intramuscular implantable electrode is provided with a strip of fabric secured around it. The fabric is woven from a polyester fiber having loops of the fiber protruding. The end of the main cylindrical body is provided with a blunt conductive nose, and the opposite end is provided with a smaller diameter rear section with an annular groove to receive tips of fingers extending from a release tube. The fingers are formed to spring outwardly and move the fingertips out of the annular groove in order to release the electrode from the release tube when a sheath over the electrode is drawn back sufficiently. The sheath compresses the fingers of the release tube and the fabric loops until it is drawn back. Muscle tissue grows into the loops to secure the electrode in place after the sheath is drawn back. The entire assembly of electrode, release tube and sheath can be inserted into the patient's muscle to the desired position through a hypodermic needle. The release tube may be used to manipulate the electrode in the patient's muscle to an optimum position before the electrode is released.

Collins, Jr., Earl R.↗

Conceptual Design of an Electric Sail Technology Demonstration Mission Spacecraft

There is great interest in examining the outer planets of our solar system and Heliopause region (edge of Solar System) and beyond regions of interstellar space by both the Planetary and Heliophysics communities. These needs are well docu-mented in the recent National Academy of Sciences Decadal Surveys. There is significant interest in developing revolutionary propulsion techniques that will enable such Heliopause scientific missions to be completed within 10 to15 years of the launch date. One such enabling propulsion technique commonly known as Electric Sail (E-Sail) propulsion employs positively charged bare wire tethers that extend radially outward from a rotating spacecraft spinning at a rate of one revolution per hour. Around the positively charged bare-wire tethers, a Debye Sheath is created once positive voltage is applied. This sheath stands off of the bare wire tether at a sheath diameter that is proportional to the voltage in the wire coupled with the flux density of solar wind ions within the solar system (or the location of spacecraft in the solar system. The protons that are expended from the sun (solar wind) at 400 to 800 km/sec are electrostatically repelled away from these positively charged Debye sheaths and propulsive thrust is produced via the resulting momentum transfer. The amount of thrust produced is directly proportional to the total wire length. The Marshall Space Flight Center (MSFC) Electric Sail team is currently funded via a two year Phase II NASA Innovative Advanced Concepts (NIAC) awarded in July 2015. The team's current activities are: 1) Developing a Particle in Cell (PIC) numeric engineering model from the experimental data collected at MSFC's Solar Wind Facility on the interaction between simulated solar wind interaction with a charged bare wire that can be applied to a variety of missions, 2) The development of the necessary tether deployers and tethers to enable successful de-ployment of multiple, multi km length bare tethers, 3) Controllability of the space-craft via a voltage bias to steer itself through the solar system to destinations of discovery. These activities once demonstrated analytically, will require a technology demonstration mission (TDM) around the year2020 to demonstrate that all systems work together seamlessly before a Heliophysics Electrostatic Rapid Transit System (HERTS) mission could be initiated. A notional TDM spacecraft that meets the requirements of such a mission will be showcased in this paper.

Wiegmann, Bruce M.↗

Flowing Plasma Interaction with an Electric Sail Tether Element

Electric sails are a relatively new concept for providing high speed propellant-less propulsion. Employing multiple tethers biased to high positive voltage levels (kV), electric sails are designed to gain momentum from the solar wind by repelling solar wind protons. To maximize the area of the sail that interacts with the solar wind, electric sails rely on the formation of a large plasma sheath around each small diameter tether. Motivated by interest in advancing the development of electric sails, a set of laboratory tests has been conducted to study the interaction of a drifting plasma with a sheath formed around a small diameter tether element biased at positive voltages. The laboratory test setup was created with Debye length scaling in mind to offer a path to extrapolate (via modeling) to full scale electric sail missions. Using an instrument known as a Differential Ion Flux Probe (DIFP) the interaction between a positively biased tether element and a drifting plasma has been measured for several scenarios. Clear evidence of the tether element sheath deflecting ions has been obtained. Maps of the flow angle downstream from the tether element have been made and they show the influence of the plasma sheath. Finally, electron current collection measurements have been made for a wide range of plasma conditions and tether element bias voltages. The electron collection data will have an impact on electric sail power requirements, as high voltage power supplies and electron guns will have to be sized to accommodate the electron currents collected by each tether.

Schneider, Todd↗

Comparative Analysis of the 2020 November 29 Solar Energetic Particle Event Observed by Parker Solar Probe

We analyze two specific features of the intense solar energetic particle (SEP) event observed by Parker Solar Probe (PSP) between 2020 November 29 and 2020 December 2. The interplanetary counterpart of the coronal mass ejection (CME) on 2020 November 29 that generated the SEP event (hereafter ICME-2) arrived at PSP (located at 0.8 au from the Sun) on 2020 December 1. ICME-225 was preceded by the passage of an interplanetary shock at 18:35 UT on 2020 November 30 (hereafter26S2), that in turn was preceded by another ICME (i.e., ICME-1) observed in situ on 2020 November 30. The two interesting features of this SEP event at PSP are: First, the presence of the intervening ICME-1 affected the evolution of the.8 MeV proton intensity time profiles resulting in the observation of inverted energy spectra throughout the passage of ICME-1. Second, the sheath region preceding ICME-2 was characterized by weak magnetic fields compared to those measured immediately after the passage of the shock S2 and during the passage of ICME-2. Comparison with prior SEP events measured at 1 au but with similar characteristics indicates that (1) low-energy particles accelerated by S2 were excluded from propagating throughout ICME-1, and (2) the low magnetic fields measured in the sheath of ICME-2 resulted from the properties of the upstream solar wind encountered by ICME-2 that was propagated into the sheath; whereas the high energetic particle energy density in the sheath did not play a dominant role in the formation of these low magnetic fields.

D Lario↗

rHealth One Demonstration Aboard ISS: A Microfluidic Bioanalyzer Based on Sheath/Hydrodynamic Focusing Flow Cytometry

The Exploration Medical Capability (ExMC) element aims to provide astronauts with the means for their own health monitoring, diagnosis, and treatment during exploration missions. As space flight ventures further from earth, the need for autonomous medical care increases under greater constraints on size, mass, and resources. One pillar for diagnosis that crew would be separated from is laboratory analysis. Even now on ISS, blood samples must be collected and returned to earth for testing. In response, ExMC is assessing how assays for hematology, bone health, radiation exposure etc. could be addressed through commercial-off-the-shelf (COTS) and Small Business Innovation Research (SBIR) funded bioanalyzers that are miniaturizing lab technology. Since missions will reach distances where there are no timely replacements, validation on the International Space Station (ISS) is a necessary part of that assessment. In partnership with NASA Johnson Space Center (JSC) Immunology Lab and the Research Operations and Integration (ROI) element, ExMC conducted a technology demonstration on ISS of the rHEALTH ONE, a flow cytometry based bioanalyzer, to assess future devices based on this design. In flow cytometry, there are predominantly three ways to focus the cells (or particles) into a single file stream: hydrodynamic focusing, microcapillary, and acoustic focusing. The rHEALTH ONE utilizes the commercial standard, sheath-based hydrodynamic focusing. rHEALTH itself represents both a company and a suite of medical tools NASA has funded through SBIR grants towards the development of a promising diagnosis instrument for exploration missions. rHEALTH ONE is the interim version of the technology, functional as a benchtop analyzer and test bed for the next generation of rHEALTH in development. Several modifications were made to the rHEALTH ONE analyzer for operation in microgravity. For function, fluid management was key. A sheath-based analyzer uses sheath fluid to flow the sample, cleaning fluid to prevent biological contamination, and a reservoir to collect the liquid waste. The rHEALTH ONE analyzer uses bottles dependent on gravity to separate the air and liquid pathways and keep the liquids contained. It uses only 1 psig of air pressure to directly push the liquid through the device, requiring little-to-no resistance at inlet and outlet. A microtubing assembly with self-sealing luer connectors was designed – featuring 0.014 mm thick durable medical balloons to hold water inside the supply bottles – to create safe containment and easy access for the crew while maintaining the analyzer’s function. For safety, copper tape was added to the interior of the plastic housing to reduce electromagnetic interference, fluid and electrical connections were secured against vibration and leaks, and gaps were further sealed to ensure containment of the optical block and lasers. Water as the sheath and cleaning fluid and TOX 0 samples were used to reduce the biohazard risk to the crew. In May 2022, European Space Agency astronaut Samantha Cristoforetti demonstrated the rHEALTH ONE aboard ISS for its sample loading, flow cytometry, and data collection capability in microgravity. The JSC Immunology Lab provided flow cytometry expertise, designed the sample test protocol, and manufactured and benchmarked the flight samples on a ‘gold-standard’ flow cytometer. The analyzer was primed with water, purged of air, and four calibration solutions of polystyrene microparticles were tested to characterize its performance. Tightly controlled procedures and excellent execution prevented air bubble interference during air/water separation, fluid transfer, sample mixing and loading. Data showed a slight increase in signal noise on 3 of 5 channels and an anomaly of fluorophores migrating in one sample (confirmed by JSC post-flight). Flight results correctly detected the change in sample, matched the analyzer’s ground performance, and were consistent with the gold-standard’s ground results. Although areas were noted for improvement, these outcomes signified complete mission success.

R. S. Miller↗

Liquid level detector

A liquid level detector for conductive liquids for vertical installation in a tank, the detector having a probe positioned within a sheath and insulated therefrom by a seal so that the tip of the probe extends proximate to but not below the lower end of the sheath, the lower end terminating in a rim that is provided with notches, said lower end being tapered, the taper and notches preventing debris collection and bubble formation, said lower end when contacting liquid as it rises will form an airtight cavity defined by the liquid, the interior sheath wall, and the seal, the compression of air in the cavity preventing liquid from further entry into the sheath and contact with the seal. As a result, the liquid cannot deposit a film to form an electrical bridge across the seal.

47 OTHER INSTRUMENTATION↗

Extender for securing a closure

An apparatus for securing a closure such as door or a window that opens and closes by movement relative to a fixed structure such as a wall or a floor. Many embodiments provide a device for relocating a padlock from its normal location where it secures a fastener (such as a hasp) to a location for the padlock that is more accessible for locking and unlocking the padlock. Typically an extender is provided, where the extender has a hook at a first end that is disposed through the eye of the staple of the hasp, and at an opposing second end the extender has an annulus, such as a hole in the extender or a loop or ring affixed to the extender. The shackle of the padlock may be disposed through the annulus and may be disposed through the eye of a second staple to secure the door or window in a closed or open position. Some embodiments employ a rigid sheath to enclose at least a portion of the extender. Typically the rigid sheath has an open state where the hook is exposed outside the sheath and a closed state where the hook is disposed within the sheath.

42 ENGINEERING↗

Summary of Thermocouple Performance During Advanced Gas Reactor Fuel Irradiation Experiments in the Advanced Test Reactor and Out-of-Pile Thermocouple Testing in Support of Such Experiments

High temperature gas reactor experiments create unique challenges for thermocouple based temperature measurements. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time dependent change in composition and, as a consequence, a time dependent drift of the thermocouple signal. This drift is particularly severe for high temperature platinum-rhodium thermocouples (Types S, R, and B); and tungsten-rhenium thermocouples (Types C and W). For lower temperature applications, previous experiences with type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly type N thermocouples are expected to be only slightly affected by neutron fluxes. Currently the use of these Nickel based thermocouples is limited when the temperature exceeds 1000°C due to drift related to phenomena other than nuclear irradiation. High rates of open-circuit failure are also typical. Over the past ten years, three long-term Advanced Gas Reactor (AGR) experiments have been conducted with measured temperatures ranging from 700oC – 1200oC. A variety of standard Type N and specialty thermocouple designs have been used in these experiments with mixed results. A brief summary of thermocouple performance in these experiments is provided. Most recently, out of pile testing has been conducted on a variety of Type N thermocouple designs at the following (nominal) temperatures and durations: 1150oC and 1200oC for 2000 hours at each temperature, followed by 200 hours at 1250oC, and 200 hours at 1300oC. The standard Type N design utilizes high purity crushed MgO insulation and an Inconel 600 sheath. Several variations on the standard Type N design were tested, including Haynes 214 alloy sheath, spinel (MgAl2O4) insulation instead of MgO, a customized sheath developed at the University of Cambridge, and finally a loose assembly thermocouple with hard fired alumina insulation and molybdenum sheath. The most current version of the High Temperature Irradiation Resistant Thermocouple (HTIR-TC) based on molybdenum/niobium alloys, and developed at Idaho National Laboratory, was also tested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sealed Attics Exposed to Two Years of Weathering in a Hot and Humid Climate

Field studies in a hot, humid climate were conducted to investigate the thermal and hygrothermal performance of ventilated attics and non-ventilated semi-conditioned attics sealed with open-cell and with closed-cell spray polyurethane foam insulation. Moisture pin measurements made in the sheathing and absolute humidity sensor data from inside the foam and from the attic air show that moisture is being stored in the foam. The moisture in the foam diffuses to and from the sheathing dependent on the pressure gradient at the foam-sheathing interface which is driven by the irradiance and night-sky radiation. Ventilated attics in the same hot, humid climate showed less moisture movement in the sheathing than those sealed with either open- or closed-cell spray foam. In the ventilated attics the relative humidity drops as the attic air warms; however, the opposite was observed in the sealed attics. Peaks in measured relative humidity in excess of 80 90% and occasionally near saturation (i.e., 100%) were observed from solar noon till about 8 PM on hot, humid days. The conditioned space of the test facility is heated and cooled by an air-to-air heat pump. Therefore the partial pressure of the indoor air during peak irradiance is almost always less than that observed in the sealed attics. Field data will be presented to bring to light the critical humidity control issues in sealed attics exposed to hot, humid climates.

insulation↗

Electric/magnetic field sensor

A UNLV novel electric/magnetic dot sensor includes a loop of conductor having two ends to the loop, a first end and a second end; the first end of the conductor seamlessly secured to a first conductor within a first sheath; the second end of the conductor seamlessly secured to a second conductor within a second sheath; and the first sheath and the second sheath positioned adjacent each other. The UNLV novel sensor can be made by removing outer layers in a segment of coaxial cable, leaving a continuous link of essentially uncovered conductor between two coaxial cable legs.

47 OTHER INSTRUMENTATION↗

Characterization of high-pressure capacitively coupled hydrogen plasmas

Capacitively coupled very-high-frequency hydrogen plasmas have been systematically diagnosed in a wide range of a gas pressure from 5 mTorr to 10 Torr. The plasma parameters, ion species, and ion energy distributions (IEDs) are measured using a Langmuir probe, optical emission spectroscopy, and energy filtered mass spectrometer. The measurement results show that the ion species in a hydrogen plasma is determined from ionization channels and subsequent ion-molecule reactions. The ions are dominated by H{sub 2}{sup +} at a less-collisional condition of < or approx. 20 mTorr, whereas those are dominated by H{sub 3}{sup +} at a collisional condition of > or approx. 20 mTorr. The IED is determined by both the sheath potential drop and ion-neutral collisions in the plasma sheath. The IED is broadened for a collisional sheath at > or approx. 0.3 Torr and the ion bombardment energy is lowered. For high-pressure discharge operated at {approx_equal}10 Torr, plasmas are characterized by a low electron temperature of {approx_equal}0.8 eV and a low ion bombardment energy of < or approx. 15 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Growth mechanism for spherical carbon particles in a dc methane plasma

The growth mechanism for spherical carbon particles of micron sizes observed in a vertically excited CH{sub 4}/Ar columnar plasma [F. Shoji, Z. Feng, A. Kono, and T. Nagai, Appl. Phys. Lett. 89, 171504 (2006)] is investigated theoretically, based on a model in which the particles are negatively charged in the plasma sheath region where they grow by capturing graphite onions with a diameter of ca. 10 nm and a positive charge. A balance of gravity and electric force keeps the particles in the sheath region during their growth. It is found that the particle radius initially increases linearly with time and then approaches a saturation radius, and that the center of gravity of the particle executes a simple harmonic oscillation about its balance position with a characteristic frequency of the order of 10 Hz determined by its specific charge, gravity, and sheath structure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The plasma transistor: A microcavity plasma device coupled with a low voltage, controllable electron emitter

A microplasma transistor has been realized by injecting electrons into the sheath of a rare gas plasma with a low voltage (|V{sub b}|<25 V), controllable electron emitter. Integrating a solid state emitter with a 500 {mu}m diam. cylindrical microcavity plasma yields a three terminal current-controlled device capable of modulating the conduction current and light intensity generated by the microplasma. For an emitter voltage of V{sub b}=-10 V, the rms charge carried by the conduction current of a Ne microplasma is tripled relative to the value measured for no current injection. Similarly, the wavelength-integrated visible emission is increased by 2.7 and 4 dB for V{sub b}=-5 and -25 V, respectively. From the continuity equation for charged particle flux in the sheath, the electron density at the edge of the sheath is determined to be n{sub s}=(3{+-}1)x10{sup 12} cm{sup -3} for an electron temperature in the 1-5 eV range. Energizing the electron emitter is estimated to reduce the ratio of the ion to electron number densities at the cathode surface from 25 to 14. A parameter {beta}{sub p}, defined as the microplasma transistor conductance normalized to that for the conventional plasma device (i.e., V{sub b}=0), is introduced and found to be {approx}40 for this unoptimized device when |V{sub b}|=5 V.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron heating in radio-frequency capacitively coupled atmospheric-pressure plasmas

In atmospheric-pressure plasmas the main electron heating mechanism is Ohmic heating, which has distinct spatial and temporal evolutions in the {alpha} and {gamma} modes. In {gamma} discharges, ionizing avalanches in the sheaths are initiated not only by secondary electrons but also by metastable pooling reactions. In {alpha} discharges, heating takes place at the sheath edges and in contrast with low-pressure plasmas, close to 50% of the power absorbed by the electrons is absorbed at the edge of the retreating sheaths. This heating is due to a field enhancement caused by the large collisionality in atmospheric-pressure discharges.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interaction of ICRF Fields with the Plasma Boundary in AUG and JET and Guidelines for Antenna Optimization

W sputtering during ICRF on ASDEX Upgrade (AUG) and temperature rise on JET A2 antenna septa are considered in connection with plasma conditions at the antenna plasma facing components and E{sub parallel} near-fields. Large antenna-plasma clearance, high gas puff and low light impurity content are favorable to reduce W sputtering in AUG. The spatial distribution of spectroscopically measured effective W sputtering yields clearly points to the existence of strong E{sub parallel} fields at the antenna box ('feeder fields') which dominate over the fields in front of the antenna straps. The picture of E{sub parallel} fields, obtained by HFSS code, corroborates the dominant role of E{sub parallel} at the antenna box on the formation of sheath-driving RF voltages for AUG. Large antenna-plasma clearance and low gas puff are favorable to reduce septum temperature of JET A2 antennas. Assuming a linear relation between the septum temperature and the sheath driving RF voltage calculated by HFSS, the changes of the temperature with dipole phasing (00{pi}{pi}, 0{pi}{pi}0 or 0{pi}0{pi}) are well described by the related changes of the RF voltages. Similarly to the AUG antenna, the strongest E{sub parallel} are found at the limiters of the JET A2 antenna for all used dipole phasings and at the septum for the phasings different from 0{pi}0{pi}. A simple general rule can be used to minimize E{sub parallel} at the antenna: image currents can be allowed only at the surfaces which do not intersect magnetic field lines at large angles of incidence. Possible antenna modifications generally rely either on a reduction of the image currents, on their short-circuiting by introducing additional conducting surfaces or on imposing the E{sub parallel} = 0 boundary condition. On the example of AUG antenna, possible options to minimize the sheath driving voltages are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗