Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Development of arrays of position-sensitive microcalorimeters for Constellation-X

We are developing arrays of position-sensitive transition-edge sensor (POST) X-ray detectors for future astronomy missions such as NASA's Constellation-X. The POST consists of multiple absorbers thermally coupled to one or more transition-edge sensor (TES). Each absorber element has a different thermal coupling to the TES. This results in a distribution of different pulse shapes and enables position discrimination between the absorber elements. POST'S are motivated by the desire to achieve the largest possible focal plane area with the fewest number of readout channels and are ideally suited to increasing the Constellation-X focal plane area, without comprising on spatial sampling. Optimizing the performance of POST'S requires careful design of key parameters such as the thermal conductances between the absorbers, TES and the heat sink. as well as the absorber heat capacities. Using recently developed signal processing algorithms we have investigated the trade-off between position-sensitivity, energy resolution and pulse decay time. based on different device design parameters for PoST's. Our new generation of PoST's utilize technology successfully developed on high resolution (approximately 2.5eV) single pixels arrays of Mo/Au TESs. also under development for Constellation-X. This includes noise mitigation features on the TES and low resistivity electroplated absorbers. We report on the first experimental results from these new one and two-channel PoST"s, consisting of all Au and composite Au/Bi absorbers, which are designed to achieve an energy resolution of < 10 eV. coupled with count-rates of 100's per pixel per second and position sensitivity over the energy range 0.3-10 keV.

Smith, S. J.↗

Using Si Diodes To Detect H2 Liquid/Vapor Interfaces

Commercially available silicon-diode temperature sensors used to detect interfaces between hydrogen liquid and hydrogen vapor at steady-state saturation conditions. Sensors mounted at short intervals along rod to form rake-like array. Array inserted in tank with rod oriented vertically, where it senses level of liquid hydrogen to resolution equal to interval between sensors. Basic idea to measure voltage across sensor while supplying small electric current that heats sensor. Because vapor cools sensor less effectively than liquid does, sensor's steady-state temperature greater when sensor surrounded by vapor than when immersed in liquid. Voltage output decreases as temperature increases for silicon diodes. Thus, temperature (voltage) reading used to determine whether liquid level above or below sensor.

Dempsey, Paula Jean↗

Analysis of the TDRS multiple access system for possible use as an attitude control system sensor

A member of the constellation of TDR satellites (TDRS) has experienced a failure of its prime earth sensor. Failure of the remaining earth sensor could result in the inability of the satellite to control its attitude and provide user services. Loss of the satellite would be a serious event. The multiple access (MA) antenna array on the TDRS has been proposed for use as a backup sensor for the attitude control system. This paper describes our analysis of the performance of the MA array as an interferometer used for accurate attitude determination. A least squares fit of a plane to the MA phase information appears to represent the TDRS body roll and pitch within about 0.1 deg. This is sufficient for SGL pointing and MA and SSA user services. Analytic improvements that include ionospheric correction may yield sufficient accuracy for KSA user services.

Blevins, Bruce Allyn↗

Arrays of High Performance Thermal Detectors

Thermal detectors have historically been the sensors of choice for applications where photoconductive or photovoltaic detectors are unavailable. While they have the advantage of broad wavelength coverage, a primary disadvantage has been sensitivity; at a given operating temperature, bolometers are typically much less sensitive than photodetectors. The development of cryogenic bolometers has resulted in thermal detectors which can reach fundamental sensitivity limits. When operated at temperatures below 0.3 K these devices can provide background-limited sensitivity for cryogenic imaging and spectroscopy in space. The past decade has seen a rapid growth in sensitivity and array format in cryogenic bolometers. Micromachining technology, combined with advances in superconducting electronics, provides a strong technological base for future developments. I will describe the present state of development of low-temperature thermal detectors, and the possible extension of this technology to higher temperature operation.

Moseley, Harvey↗

Thermal Transport Model for Heat Sink Design

A document discusses the development of a finite element model for describing thermal transport through microcalorimeter arrays in order to assist in heat-sinking design. A fabricated multi-absorber transition edge sensor (PoST) was designed in order to reduce device wiring density by a factor of four. The finite element model consists of breaking the microcalorimeter array into separate elements, including the transition edge sensor (TES) and the silicon substrate on which the sensor is deposited. Each element is then broken up into subelements, whose surface area subtends 10 10 microns. The heat capacity per unit temperature, thermal conductance, and thermal diffusivity of each subelement are the model inputs, as are the temperatures of each subelement. Numerical integration using the Finite in Time Centered in Space algorithm of the thermal diffusion equation is then performed in order to obtain a temporal evolution of the subelement temperature. Thermal transport across interfaces is modeled using a thermal boundary resistance obtained using the acoustic mismatch model. The document concludes with a discussion of the PoST fabrication. PoSTs are novel because they enable incident x-ray position sensitivity with good energy resolution and low wiring density.

Chervenak, James A.↗

Gyro and accelerometer failure detection and identification in redundant sensor systems

Algorithms for failure detection and identification for redundant noncolinear arrays of single degree of freedom gyros and accelerometers are described. These algorithms are optimum in the sense that detection occurs as soon as it is no longer possible to account for the instrument outputs as the outputs of good instruments operating within their noise tolerances, and identification occurs as soon as it is true that only a particular instrument failure could account for the actual instrument outputs within the noise tolerance of good instruments. An estimation algorithm is described which minimizes the maximum possible estimation error magnitude for the given set of instrument outputs. Monte Carlo simulation results are presented for the application of the algorithms to an inertial reference unit consisting of six gyros and six accelerometers in two alternate configurations.

Potter, J. E.↗

Acoustic Measurements from Wind Tunnel Test of AMELIA - Advanced Model for Extreme Lift and Improved Aeroacoustics

A wind tunnel test has been conducted to measure the aerodynamic and acoustic performance of an active circulation-control aircraft with leading- and trailing- edge slot blowing. The 11 Advanced Model for Extreme Lift and Improved Aeroacoustics (AMELIA) model was tested in the Arnold Engineering Development Center (AEDC) National Full Scale Aerodynamics Complex (NFAC) 40- by 80-Ft wind tunnel. Forward velocities ranged from 0 to Mach 0.15 and total slot mass-flow was varied from 0 to 2.8 lbmsec. Angle-of-attack and sideslip ranges were -5 to 25 and -10 to 10, respectively.This reports summarizes acoustic measurements from the wind tunnel test and the corrections applied to the released acoustic data. The analysis focuses on measurements for the clean wing configuration (turbine propulsion simulators removed) with trailing-and leading-edge slot blowing and with trailing-edge blowing, for systematic variations in slot mass flow from nearly zero to the system maximum. The acoustic measurements from a fixed phased microphone array and seven fixed microphones were corrected for sensor directional response and atmospheric attenuation. Graphs of 13-octave spectra, narrowband spectra, and directional variations in OASPL are presented for each active lift configuration. This report is intended to document the corresponding set of corrected data that is now available for development and verification of new predictive models of the active lift source.For large slot mass flow conditions 13-octave spectral shapes were level and flat, typical of a pink noise source. Little source directivity was present in the OASPL levels for the 0 flap conditions and show only a slight downstream increase with the 60 flap configuration. For moderate to high slot mass flow conditions trailing-edge only blowing spectra were similar to leading- and trailing edge blowing cases. However for the lower mass flows variations of as much as 5 dB were observed.

CCW↗

Lightning mapper and the future

A trade-off analysis was completed that reveals how the lightning mapper detection efficiency will change as a function of interference filter bandwidth, pixel field of view, and telescope aperture. It is shown that the critical parameter on which we have minimum flexibility is filter band-width. The problem is that too narrow a filter bandwidth is incompatible with wide areal coverage. The trade-off analysis demonstrates that an 80 percent lightning detection efficiency will technically be relatively straight-forward, while a 90 percent detection efficiency will apparently be difficult to achieve. Three focal plane designs are currently under consideration. One would use a single large, solid state silicon integrating array with multiple output channels and off-the-focal-plane analog, time domain, background removing fibers. A second design would use the same technology, but the sensor would consist of up to four virtually independent focal plane arrays. This design reduces the areal coverage of each detector. Thus narrower interference filters could be utilized. Superior performance would be realized at a probable increase in cost. The final design would use a three-dimensional focal plane in order to perform background removal at the focal plane. Superior performance would be achieved along with reduced weight and power requirements. Unfortunately, this focal plane technology is still under development.

Christian, H. J.↗

Synthesis of Carbon Nanotubes Array by CVD

Since the properties of multi-wall carbon nanotubes (MWCNT) are superior in many devices such as electronics and sensors, many efforts have been involved in synthesizing particular structural or dimensional MWCNT. Uniform aligned MWCNT array is one of the prototype structures for devices such as filed emission device and microelectromechanical systems in which a large length to diameter ratio may also be required. Most aligned MWCNT recently synthesized by plasma enhanced chemical vapor deposition (CVD) have cone shaped structures. This presentation will illustrate aligned MWCNT array synthesized on silicon substrates using thermal CVD that could produce MWCNT with uniform diameter. An array of nickel particles was used as catalyst for MWCNT growth. A thin Ti or Au buffer layer was coated on the substrate prior to depositing nickel particles. Because the MWCNT size depends on the catalyst particle size, the nickel particle size annealed at various temperatures was investigated. MWCNT were grown on the substrate in the temperature range of 700 C - 1000 C and the pressure range of 1 to 300 torr. Methane and hydrogen gases with methane content of 1 - 10 % were used for the MWCNT synthesis. Morphology, length and diameter of MWCNT were determined by scanning electron microscopy and Raman spectroscopy. The detailed results of synthesis and characterizations will be discussed in the presentation.

Zhu, S.↗

Solid state, CCD-buried channel, television camera study and design

An investigation of an all solid state television camera design, which uses a buried channel charge-coupled device (CCD) as the image sensor, was undertaken. A 380 x 488 element CCD array was utilized to ensure compatibility with 525 line transmission and display monitor equipment. Specific camera design approaches selected for study and analysis included (a) optional clocking modes for either fast (1/60 second) or normal (1/30 second) frame readout, (b) techniques for the elimination or suppression of CCD blemish effects, and (c) automatic light control and video gain control techniques to eliminate or minimize sensor overload due to bright objects in the scene. Preferred approaches were determined and integrated into a design which addresses the program requirements for a deliverable solid state TV camera.

Hoagland, K. A.↗

Flexible Micropost Arrays for Shear Stress Measurement

Increased fuel costs, heightened environmental protection requirements, and noise abatement continue to place drag reduction at the forefront of aerospace research priorities. Unfortunately, shortfalls still exist in the fundamental understanding of boundary-layer airflow over aerodynamic surfaces, especially regarding drag arising from skin friction. For example, there is insufficient availability of instrumentation to adequately characterize complex flows with strong pressure gradients, heat transfer, wall mass flux, three-dimensionality, separation, shock waves, and transient phenomena. One example is the acoustic liner efficacy on aircraft engine nacelle walls. Active measurement of shear stress in boundary layer airflow would enable a better understanding of how aircraft structure and flight dynamics affect skin friction. Current shear stress measurement techniques suffer from reliability, complexity, and airflow disruption, thereby compromising resultant shear stress data. The state-of-the-art for shear stress sensing uses indirect or direct measurement techniques. Indirect measurements (e.g., hot-wire, heat flux gages, oil interferometry, laser Doppler anemometry, small scale pressure drag surfaces, i.e., fences) require intricate knowledge of the studied flow, restrictive instrument arrangements, large surface areas, flow disruption, or seeding material; with smaller, higher bandwidth probes under development. Direct measurements involve strain displacement of a sensor element and require no prior knowledge of the flow. Unfortunately, conventional "floating" recessed components for direct measurements are mm to cm in size. Whispering gallery mode devices and Fiber Bragg Gratings are examples of recent additions to this type of sensor with much smaller (m) sensor components. Direct detection techniques are often single point measurements and difficult to calibrate and implement in wind tunnel experiments. In addition, the wiring, packaging, and installation of delicate micro-electromechanical devices impede the use of most direct shear sensors. Similarly, the cavity required for sensing element displacement is sensitive to particulate obstruction. This work was focused on developing a shear stress sensor for use in subsonic wind tunnel test facilities applicable to an array of test configurations. The non-displacement shear sensors described here have minimal packaging requirements resulting in minimal or no disturbance of boundary layer flow. Compared to previous concepts, device installation could be simple with reduced cost and down-time. The novelty lies in the creation of low profile (nanoscale to 100 μm) micropost arrays that stay within the viscous sub-layer of the airflow. Aerodynamic forces, which are related to the surface shear stress, cause post deflection and optical property changes. Ultimately, a reliable, accurate shear stress sensor that does not disrupt the airflow has the potential to provide high value data for flow physics researchers, aerodynamicists, and aircraft manufacturers leading to greater flight efficiency arising from more in-depth knowledge on how aircraft design impacts near surface properties.

Wohl, Christopher J.↗

Shack-Hartmann Phasing of Segmented Telescopes: Systematic Effects from Lenslet Arrays

The segments in the Keck telescopes are routinely phased using a Shack-Hartmann wavefront sensor with sub-apertures that span adjacent segments. However, one potential limitation to the absolute accuracy of this technique is that it relies on a lenslet array (or a single lens plus a prism array) to form the subimages. These optics have the potential to introduce wavefront errors and stray reflections at the subaperture level that will bias the phasing measurement. We present laboratory data to quantify this effect, using measured errors from Keck and two other lenslet arrays. In addition, as part of the design of the Thirty Meter Telescope Alignment and Phasing System we present a preliminary investigation of a lenslet-free approach that relies on Fresnel diffraction to form the subimages at the CCD. Such a technique has several advantages, including the elimination of lenslet aberrations.

segmented mirrors↗

Advanced ACTPol Cryogenic Detector Arrays and Readout

Advanced ACTPol is a polarization-sensitive upgrade for the 6 m aperture Atacama Cosmology Telescope, adding new frequencies and increasing sensitivity over the previous ACTPol receiver. In 2016, Advanced ACTPol will begin to map approximately half the sky in five frequency bands (28-230 GHz). Its maps of primary and secondary cosmic microwave background anisotropies-imaged in intensity and polarization at few arcminute-scale resolution-will enable precision cosmological constraints and also awide array of cross-correlation science that probes the expansion history of the universe and the growth of structure via gravitational collapse. To accomplish these scientific goals, the AdvancedACTPol receiver will be a significant upgrade to the ACTPol receiver, including four new multichroic arrays of cryogenic, feedhorn-coupled AlMn transition edge sensor polarimeters (fabricated on 150 mm diameter wafers); a system of continuously rotating meta-material silicon half-wave plates; and a new multiplexing readout architecture which uses superconducting quantum interference devices and time division to achieve a 64-row multiplexing factor. Here we present the status and scientific goals of the Advanced ACTPol instrument, emphasizing the design and implementation of the AdvancedACTPol cryogenic detector arrays.

secondary cosmic microwave background anisotropies↗

Solid state television camera (CCD-buried channel)

The development of an all solid state television camera, which uses a buried channel charge coupled device (CCD) as the image sensor, was undertaken. A 380 x 488 element CCD array is utilized to ensure compatibility with 525 line transmission and display monitor equipment. Specific camera design approaches selected for study and analysis included (a) optional clocking modes for either fast (1/60 second) or normal (1/30 second) frame readout, (b) techniques for the elimination or suppression of CCD blemish effects, and (c) automatic light control and video gain control (i.e., ALC and AGC) techniques to eliminate or minimize sensor overload due to bright objects in the scene. Preferred approaches were determined and integrated into a deliverable solid state TV camera which addressed the program requirements for a prototype qualifiable to space environment conditions.

Source record↗

Test results on intensified charge coupled devices

CCD imaging arrays were evaluated for a photon counting astronomical sensor. Results show noise corresponding to less than 100 rms electrons and gains of approximately 1000 at 10kV accelerating voltage (greater than 5000 at 25kV). Measured charge transfer efficiencies are in excess of 0.9999, signal saturation levels are as high as 990000 electrons per pixel and peak quantum efficiencies are greater than 75%. Successful proximity focussed intensified charge coupled devices (ICCD) have been fabricated, although problems still exist with contamination and possible structural failures in the CCD's during tube manufacture.

Williams, J. T.↗

Ground truth management system to support multispectral scanner /MSS/ digital analysis

A computerized geographic information system for management of ground truth has been designed and implemented to relate MSS classification results to in situ observations. The ground truth system transforms, generalizes and rectifies ground observations to conform to the pixel size and shape of high resolution MSS aircraft data. These observations can then be aggregated for comparison to lower resolution sensor data. Construction of a digital ground truth array allows direct pixel by pixel comparison between classification results of MSS data and ground truth. By making comparisons, analysts can identify spatial distribution of error within the MSS data as well as usual figures of merit for the classifications. Use of the ground truth system permits investigators to compare a variety of environmental or anthropogenic data, such as soil color or tillage patterns, with classification results and allows direct inclusion of such data into classification operations. To illustrate the system, examples from classification of simulated Thematic Mapper data for agricultural test sites in North Dakota and Kansas are provided.

Coiner, J. C.↗

An industrial perspective of the LANDSAT opportunity

The feasibility of enhancing LANDSAT products to provide the greatest usability low cost data possible can be determined through government sponsorship and finance of one or more task forces composed of a critical number of experts in multiple disciplines from many industries and academia. The synergism of multiple minds addressing singular problems without the creation of permanent or perpetual structures must yield output in the form of implementable specifications, even if presented as alternatives. Changes are needed within the spacecraft in order to account for Sun angle changes. The use of pointing accuracy to make geometric corrections (and possible radiometric corrections, is needed more than onboard data reduction and information extraction, which assume a proper knowledge of application and reduce potential utilization. Multilinear arrays need to be investigated and methods for sensor calibration and for determining the effects of atmospheric inversion, as well as the best way to back out the modulation transfer function must be determined.

Williams, B. F.↗

Time delay and integration detectors using charge transfer devices

An imaging system comprises a multi-channel matrix array of CCD devices wherein a number of sensor cells (pixels) in each channel are subdivided and operated in discrete intercoupled groups of subarrays with a readout CCD shift register terminating each end of the channels. Clock voltages, applied to the subarrays, selectively cause charge signal flow in each subarray in either direction independent of the other subarrays. By selective application of four phase clock voltages, either one, two or all three of the sections subarray sections cause charge signal flow in one direction, while the remainder cause charge signal flow in the opposite direction. This creates a form of selective electronic exposure control which provides an effective variable time delay and integration of three, six or nine sensor cells or integration stages. The device is constructed on a semiconductor sustrate with a buried channel and is adapted for front surface imaging through transparent doped tin oxide gates.

Mccann, D. H.↗