Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sampled value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Ethylene monitoring and control system

A system that can accurately monitor and control low concentrations of ethylene gas includes a test chamber configured to receive sample gas potentially containing an ethylene concentration and ozone, a detector configured to receive light produced during a reaction between the ethylene and ozone and to produce signals related thereto, and a computer connected to the detector to process the signals to determine therefrom a value of the concentration of ethylene in the sample gas. The supply for the system can include a four way valve configured to receive pressurized gas at one input and a test chamber. A piston is journaled in the test chamber with a drive end disposed in a drive chamber and a reaction end defining with walls of the test chamber a variable volume reaction chamber. The drive end of the piston is pneumatically connected to two ports of the four way valve to provide motive force to the piston. A manifold is connected to the variable volume reaction chamber, and is configured to receive sample gasses from at least one of a plurality of ports connectable to degreening rooms and to supply the sample gas to the reactive chamber for reaction with ozone. The apparatus can be used to monitor and control the ethylene concentration in multiple degreening rooms.

Nelson, Bruce N.↗

Ethylene monitoring and control system

A system that can accurately monitor and control low concentrations of ethylene gas includes a test chamber configured to receive sample gas potentially containing an ethylene concentration and ozone, a detector configured to receive light produced during a reaction between the ethylene and ozone and to produce signals related thereto, and a computer connected to the detector to process the signals to determine therefrom a value of the concentration of ethylene in the sample gas. The supply for the system can include a four way valve configured to receive pressurized gas at one input and a test chamber. A piston is journaled in the test chamber with a drive end disposed in a drive chamber and a reaction end defining with walls of the test chamber a variable volume reaction chamber. The drive end of the piston is pneumatically connected to two ports of the four way valve to provide motive force to the piston. A manifold is connected to the variable volume reaction chamber, and is configured to receive sample gasses from at least one of a plurality of ports connectable to degreening rooms and to supply the sample gas to the reactive chamber for reaction with ozone. The apparatus can be used to monitor and control the ethylene concentration in multiple degreening rooms.

Nelson, Bruce N.↗

Wide bandgap photoconductor (SiC:V)-based optically addressed light valve for high fluence operation

Optically addressable light valves based on wide bandgap 4H- and 6H-SiC as photoconductors were designed to withstand higher operational laser fluences than the state of-the-art bismuth silicon oxide (BSO; Bi 12 SiO 20 ) based devices. Vanadium-doped SiC was selected as the photoconductors due to their reasonable photoresponsivity while many fold improvement in laser induced damage threshold as compared to BSO. The laser induced damage threshold values of the materials were measured after exposing ~ 200 sites on the samples to increasing levels of fluence of a gaussian pulsed Nd: YAG laser system (1064 nm) with a 5 Hz repetition rate. The measured damage threshold values for BSO, 4H- and 6H-SiC were 0.4 J/cm 2 , 1.75 J/cm 2 and 1.8 J/cm 2 , respectively. Photoconductive switches based on 4H and 6H-SiC samples were characterized at wavelengths of 380 nm, 405 nm, and 447 nm. The peak photoresponsivity values of the 4H- and 6H-SiC materials were measured to be under 380 nm and 405 nm, respectively. The photoconductor was bonded to a BK7 optical window with 5 μm diameter microspheres as spacers. A twisted nematic type E7 liquid crystal (LC) was filled in the 5 μm gap in a vacuum chamber. The desired alignment of the liquid crystal was achieved by mutually orthogonal orientation of LC alignment layers on the two mating faces (SiC and BK7). The fabricated devices were modulated using address beams of wavelengths 380 nm, 405 nm, and 447 nm. In conclusion, required transmission levels of > 90% was achieved for the fabricated OALVs for a sinusoidal voltage waveform that meets the lifetime requirement of the device.

36 MATERIALS SCIENCE↗

Infrared band extinctions and complex refractive indices of crystalline C2H2 and C4H2

Thermal IR absorption intensities are obtained for thin films of crystalline C2H2 and C4H2 at 70 K, and their n and k complex refractive indices are ascertained by separating true film absorption from interface reflection on the basis of an analysis of the transmission spectrum ratio for two sample thicknesses. This method significantly simplifies the n and k iteration process. The n and k values determined in the laboratory will in most cases reproduce a given sample thickness' observed transmission to within + or - 5 percent.

Khanna, R. K.↗

Background contamination by coplanar polychlorinated biphenyls (PCBs) in trace level high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) analytical procedures

The addition of the "dioxin-like" polychlorinated biphenyl (PCB) congeners to the assessment of risk associated with the 2,3,7,8-chlorine substituted dioxins and furans has dramatically increased the number of laboratories worldwide that are developing analytical procedures for their detection and quantitation. Most of these procedures are based on established sample preparation and analytical techniques employing high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS), which are used for the analyses of dioxin/furans at low parts-per-trillion (ppt) levels. A significant and widespread problem that arises when using these sample preparation procedures for the analysis of coplanar PCBs is the presence of background levels of these congeners. Industrial processes, urban incineration, leaking electrical transformers, hazardous waste accidents, and improper waste disposal practices have released appreciable quantities of PCBs into the environment. This contamination has resulted in the global distribution of these compounds via the atmosphere and their ubiquitous presence in ambient air. The background presence of these compounds in method blanks must be addressed when determining the exact concentrations of these and other congeners in environmental samples. In this study reliable procedures were developed to accurately define these background levels and assess their variability over the course of the study. The background subtraction procedures developed and employed increase the probability that the values reported accurately represent the concentrations found in the samples and were not biased due to this background contamination.

Polychlorinated Biphenyls/analysis/metabolism↗

Toxicity of pyrolysis products: Influence of experimental conditions - The MSTL/UT and NASA/JSC Procedures

Ten sample materials of various polymeric composition were evaluated for toxicity of pyrolysis products utilizing two significantly different experimental methods, the MSTL/UT and NASA/JSC Procedures. A comparison of the LD(50) values obtained by the two methods for these ten samples did not yield a significant correlation. However, when the samples were ranked in order of increasing toxicity by each method independently, a comparison of their rank order toxicity improved the correlation. Because of interlaboratory variations in pyrolysis/combustion test procedures, it is suggested a series of standard materials be adopted to facilitate interlaboratory comparisons of data on pyrolysis toxicity.

Lawrence, W. H.↗

Comparison of z-known GRBs with the Main Groups of Bright BATSE Events

The small reference sample of six BATSE gamma-ray bursts with known redshifts from optical afterglows is compared with a comparison group of the 218 brightest BATSE bursts. These two groups are shown to be consistent both with respect to the distributions of the spectral peak parameter in the observer's frame and also with respect to the distributions of the frame-independent cosmological invariant parameter (CIP). Using the known values of the redshifts z for the reference sample, the rest-frame distribution of spectral parameters is built. The de-redshifted distribution of the spectral parameters of the reference sample is compared with distribution of these parameters for the comparison group after de-redshifting by the factor 1/(1+z), with z a free parameter. Requiring consistency between these two distributions produces a collective estimation of the best fitting redshifts z for the comparison group, z=1.8--3.6. These values can be considered as the average cosmological redshift of the sources of the brightest BATSE bursts. The most probable value of the peak energy of the spectrum in the rest frame is 920 keV, close to the rest mass of an electron-positron pair.

Mitrofanov, Igor G.↗

Evolution versus pulsation along the horizontal branch of M15

The study combines the horizontal-branch tracks (HBETs) of Lee and Demarque (1990) with the period/mean density law of pulsation theory in order to account for the observed periods and relative luminosities of 62 RR Lyrae stars in the extreme metal-poor globular cluster M15. These tests were performed for a number of assumed values for the mean luminosity of the M15 RR Lyrae sample and for different assumed boundaries for the pulsational instability strip. It was found that no single set of models could account for all the RR Lyrae periods and luminosities while simultaneously reproducing the observed value for the the ratio of blue to variable stars. The hypothesis that an RR Lyrae sample evolved near helium exhaustion along the HBETs cannot explain the relatively large number of variable stars in M15 is confirmed.

Simon, Norman R.↗

Lunar rock types - The role of plagioclase in non-mare and highland rock types

Some nonmare and highland rock types (14310 type KREEP and very high Al2O3 basalts) have the internal chemical variations expected for a plagioclase-liquid system. The observed Eu variations in these rock types suggest a D(Eu) 1/p of 0.6 to 0.7. The Sr variations suggest a D(Sr) 1/p of about 0.6, with values as low as 0.35 suggested for some materials from sample 14063. Common Apollo 14 KREEP and Apollo 15 KREEP do not show internal Sr, Eu, Al2O3 variations consistent with the D(Eu, Sr) 1/p values derived for 14310 type KREEP. Major element and experimental data indicate that olivine or pyroxene is a large, perhaps dominant, controller of chemical variations within common Apollo 14 KREEP. The application of these distribution coefficients to pure anorthosites like 15415 yields the model dependent conclusion that the silicate liquids with which such anorthosites may have been chemically equilibrated have not yet been analyzed and perhaps not directly sampled.

Hubbard, N. J.↗

Application of Scanning-Imaging X-Ray Microscopy to Fluid Inclusion Candidates in Carbonates of Carbonaceous Chondrites

In order to search for such fluid inclusions in carbonaceous chondrites, a nondestructive technique using x-ray micro-absorption tomography combined with FIB sampling was developed and applied to a carbonaceous chondrite. They found fluid inclusion candidates in calcite grains, which were formed by aqueous alteration. However, they could not determine whether they are really aqueous fluids or merely voids. Phase and absorption contrast images can be simultaneously obtained in 3D by using scanning-imaging x-ray microscopy (SIXM). In refractive index, n=1-sigma+i(beta), in the real part, 1-sigma is the refractive index with decrement, sigma, which is nearly proportional to the density, and the imaginary part, beta, is the extinction coefficient, which is related to the liner attenuation coefficient, mu. Many phases, including water and organic materials as well as minerals, can be identified by SIXM, and this technique has potential availability for Hayabusa-2 sample analysis too. In this study, we examined quantitative performance of d and m values and the spatial resolution in SIXM by using standard materials, and applied this technique to carbonaceous chondrite samples. We used POM ([CH2O]n), silicon, quartz, forsterite, corundum, magnetite and nickel as standard materials for examining the sigma and mu values. A fluid inclusion in terrestrial quartz and bi-valve shell (Atrina vexillum), which are composed of calcite and organic layers with different thickness, were also used for examining the spatial resolution. The Ivuna (CI) and Sutter's Mill (CM) meteorites were used as carbonaceous chondrite samples. Rod- or cube-shaped samples 20-30 micron in size were extracted by using FIB from cross-sectional surfaces of the standard materials or polished thin sections of the chondrites, which was previously observed with SEM. Then, the sample was attached to a thin W-needle and imaged by SIXM system at beamline BL47XU, SPring-8, Japan. The slice thickness was 109.3 nm and the pixel size was mostly 100 nm.

Tsuchiyama, Akira↗

Microstructure development and properties of micro-alloyed copper, Cu-0.3Zr-0.15Ag, produced by electron beam additive manufacturing

A micro-alloyed copper powder, Cu-0.3Zr-0.15Ag wt.%, was produced using gas atomization reaction synthesis. Zirconium was added to copper to sequester the oxygen present as copper oxide surface films on the powder particles. The as-received powders, as well as the intentionally oxidized powders were used to fabricate solid test articles by electron beam powder bed fusion additive manufacturing. Dense samples fabricated from as-received powder demonstrated nominal UTS, yield, and elongation values at 260 MPa, 150 MPa, and 34%, respectively. The average electrical conductivity of these samples was measured at 95% of the international annealed copper standard (IACS). Samples fabricated from the oxidized powder exhibited nominal UTS, yield, and elongation of 241 MPa, 146 MPa, and 43%, respectively, with an electrical conductivity of 95 % IACS. During characterization, it was observed that, rather than forming nano-scale dispersoids, the Zirconia (ZrO 2 ) appeared as discontinuous stringers in the metallographic cross-sections that crossed grain and melt pool boundaries. This was rationalized by tracing the presence of the micro-alloying addition of elemental zirconium, which was found to react with surface oxides dissociated in the melt pool to form ZrO 2 , which then solidified on the surface of the melt pool through an allotropic transformation to monoclinic ZrO 2 in discontinuous films and spheroids ranging in size from nanometers to microns. This was confirmed by microscopic analysis of the tops of the melt pools. On subsequent melt passes, these ZrO 2 structures were displaced and redistributed within the melt pool.

36 MATERIALS SCIENCE↗

Calibrating the Ordovician Radiation of marine life: implications for Phanerozoic diversity trends

It has long been suspected that trends in global marine biodiversity calibrated for the Phanerozoic may be affected by sampling problems. However, this possibility has not been evaluated definitively, and raw diversity trends are generally accepted at face value in macroevolutionary investigations. Here, we analyze a global-scale sample of fossil occurrences that allows us to determine directly the effects of sample size on the calibration of what is generally thought to be among the most significant global biodiversity increases in the history of life: the Ordovician Radiation. Utilizing a composite database that includes trilobites, brachiopods, and three classes of molluscs, we conduct rarefaction analyses to demonstrate that the diversification trajectory for the Radiation was considerably different than suggested by raw diversity time-series. Our analyses suggest that a substantial portion of the increase recognized in raw diversity depictions for the last three Ordovician epochs (the Llandeilian, Caradocian, and Ashgillian) is a consequence of increased sample size of the preserved and catalogued fossil record. We also use biometric data for a global sample of Ordovician trilobites, along with methods of measuring morphological diversity that are not biased by sample size, to show that morphological diversification in this major clade had leveled off by the Llanvirnian. The discordance between raw diversity depictions and more robust taxonomic and morphological diversity metrics suggests that sampling effects may strongly influence our perception of biodiversity trends throughout the Phanerozoic.

Non-NASA Center↗

Collective Analysis of Alpha Particle Losses Due to Self-Absorption by Mass Loading on Radioactive Particulate Glass Fiber Filters

In this study, we derived a relationship between filter mass loading and the percent loss during analysis using the mass loading data collected from six previous studies of self-absorption. Components of mass loading include particulate dust, radioactive particulates, and filter material. In a research report published in 1984, Higby calculated a minimum burial depth for an alpha particle to be lost due to absorption (100% loss) of about 3.7 mg/cm 2 based on calculations for the range of 239-Pu alpha particles in glass fiber filters. From there, Higby concluded that a correction factor of 0.85 assumes approximately 15% losses in the count rate of both alpha and beta particles. In 2000, Luetzelschwab et al. recommended assuming a 40% loss at a loading of 3.3 mg/cm 2 and a 28% loss for a loading of 2.3 mg/cm 2 which included the frontal face mass of the filter. More recently, the 100% losses due to absorption were reported to be in the 10 mg/cm 2 range. Presented here is a trinomial relationship method of relating percent loss due to self-absorption to filter mass loading, based on data reported by Higby, Luetzelschwab et al., Huang et al., Barnett et al., Smith et al., and Hogue et al. Under normal operating conditions at the stacks monitored by Effluent Management, the mass loading of sample filters averages 0.09 ± 0.12 (2s) mg/cm 2 (excluding negative values and outliers) and ranges from 0 mg/cm 2 to 0.24 mg/cm 2 . Based on current mass loading results for Effluent Management stack sample filters, the forced-zero trinomial relationship method estimated self-absorption losses of less than 5%. Because American National Standards Institute/Health Physics Society N13.1-2011 guidelines indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the count rate by more than 5%, it is possible continued application of a correction factor to the Effluent Management stack samples is no longer necessary. Nevertheless, continuing to assign a correction factor at the 5% threshold (i.e., 0.95) would be a conservative approach.

36 MATERIALS SCIENCE↗

Depositional history of core section 74001 - Depth profiles of maturity, FeO, and metal

Samples from every 0.5-cm interval of soil in core section 74001 have been studied by ferromagnetic resonance (FMR) and magnetic techniques. The values of the FMR maturity index show that the 74001 samples are very immature (the index ranges from 0.14 to 0.29 units) and have not seen appreciable, if any, surface exposure since their deposition. In fact, the small amount of fine-grained metal in the 74001 samples is probably not acquired as a result of their exposure to the micrometeoroid flux at the lunar surface. Thus, the black-glass soil of 74001 was deposited very rapidly, probably in a single episode or several closely spaced episodes of lunar fire fountaining. The average concentration of FeO and its standard deviation for all the 74001 samples are 22.5 + or - 0.3 wt.%. Since the FeO concentration is so uniform, no large variations in the major-element chemistry of 74001 are expected, with the possible exception of the volatile elements. The concentration of coarse-grained metal, which is measured magnetically, and its standard deviation are 0.15 + or - 0.01 wt.%. The coarse-grained metal probably precipitated contemporaneously with the silicate and oxide phases in the black-glass droplets.

Morris, R. V.↗

Complex permittivity of lanthanum aluminate in the 20 to 300 K temperature range from 26.5 to 40.0 GHz

Dielectric constants of microwave substrates are required in the design of superconducting microwave circuits at various temperatures. In this paper, the results are reported of a study of the complex permittivity of the newly developed lanthanum aluminate (LaAlO3) substrate, in the 20 to 300 K temperature range at frequencies from 26.5 to 40.0 GHz. The value of the complex permittivity was obtained by measuring the sample scattering parameters using a microwave waveguide technique. It is observed that, while the dielectric constant did not change appreciably with frequency, its value decreased by approximately 14 percent from room temperature to 20 K.

Miranda, F. A.↗

Effects of Ambient High Temperature Exposure on Alumina-Titania High Emittance Surfaces for Solar Dynamic Systems

Solar dynamic (SD) space power systems require durable, high emittance surfaces on a number of critical components, such as heat receiver interior surfaces and parasitic load radiator (PLR) elements. To enhance surface characteristics, an alumina-titania coating has been applied to 500 heat receiver thermal energy containment canisters and the PLR of NASA Lewis Research Center's (LeRC) 2 kW SD ground test demonstrator (GTD). The alumina-titania coating was chosen because it had been found to maintain its high emittance under vacuum (less than or equal to 10(exp -6) torr) at high temperatures (1457 F (827 C)) for an extended period (approximately 2,700 hours). However, preflight verification of SD systems components, such as the PLR require operation at ambient pressure and high temperatures. Therefore, the purpose of this research was to evaluate the durability of the alumina-titania coating at high temperature in air. Fifteen of sixteen alumina-titania coated Incoloy samples were exposed to high temperatures (600 F (316 C) to l500 F (816 C)) for various durations (2 to 32 hours). Samples, were characterized prior to and after heat treatment for reflectance, solar absorptance, room temperature emittance and emittance at 1,200 F (649 C). Samples were also examined to detect physical defects and to determine surface chemistry using optical microscopy, scanning electron microscopy operated with an energy dispersive spectroscopy (EDS) system, and x ray photoelectron spectroscopy (XPS). Visual examination of the heat-treated samples showed a whitening of samples exposed to temperatures of 1,000 F (538 C) and above. Correspondingly, the optical properties of these samples had degraded. A sample exposed to 1,500 F (816 C) for 24 hours had whitened and the thermal emittance at 1,200 F (649 C) had decreased from the non-heat treated value of 0.94 to 0.62. The coating on this sample had become embrittled with spalling off the substrate noticeable at several locations. Based on this research it is recommended that preflight testing of SD components with alumina-titania coatings be restricted to temperatures no greater than 600 F (316 C) in air to avoid optical degradation. Moreover, components with the alumina-titania coating are likely to experience optical property degradation with direct atomic oxygen exposure in space.

deGroh, Kim K.↗

Cosmological parameters and evolution of the galaxy luminosity function

The relationship between the observed distribution of discrete sources of a flux limited sample, the luminosity function of these sources, and the cosmological model is discussed. It is stressed that some assumptions about the form and evolution of the luminosity function must be made in order to determine the cosmological parameters from the observed distribution of sources. Presented is a method to test the validity of these assumptions using the observations. It is shown how, using higher moments of the observed distribution, one can determine, independently of the cosmological model, all parameters of the luminosity function except those describing evolution of the density and the luminosity of the luminosity function. These methods are applied to the sample of approximately 1000 galaxies recently used by Loh and Spillar to determine a value of the cosmological density parameter Omega approx = 1. It is shown that the assumptions made by Loh and Spillar about the luminosity function are inconsistent with the data, and that a self-consistent treatment of the data indicates a lower value of Omega approx = 0.2 and a flatter luminosity function. It should be noted, however, that incompleteness in the sample could cause a flattening of the luminosity function and lower the calculated value of Omega and that uncertainty in the values of these parameters due to random fluctuations is large.

Caditz, David↗

Cosmological parameters and evolution of the galaxy luminosity function

The relationship between the observed distribution of discrete sources of a flux limited sample, the luminosity function of these sources, and the cosmological model is discussed. It is stressed that some assumptions about the form and evolution of the luminosity function must be made in order to determine the cosmological parameters from the observed distribution of sources. Presented is a method to test the validity of these assumptions using the observations. It is shown how, using higher moments of the observed distribution, one can determine, independently of the cosmological model, all parameters of the luminosity function except those describing evolution of the density and the luminosity of the luminosity function. These methods are applied to the sample of approximately 1000 galaxies recently used by Loh and Spillar to determine a value of the cosmological density parameter Omega approx = 1. It is shown that the assumptions made by Loh and Spillar about the luminosity function are inconsistent with the data, and that a self-consistent treatment of the data indicates a lower value of Omega approx = 0.2 and a flatter luminosity function. It should be noted, however, that incompleteness in the sample could cause a flattening of the luminosity function and lower the calculated value of Omega and that uncertainty in the values of these parameters due to random fluctuations is large.

Caditz, David↗