Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reference models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This document focuses on a single end-use savings shape measure: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER). This document builds on details established in the single-stage document (Maguire et al. 2025) to detail differences in the approach to modeling this higher efficiency, but more commonly deployed, type of geothermal heat pump. Specific EnergyPlus objects and product specific curves used are highlighted along with showing the results of this measure compared to the baseline and single-speed geothermal heat pumps. Two-speed geothermal heat pumps are able to save even more energy and on utility bills than single-speed products, albeit at the expense of a higher first cost.

15 GEOTHERMAL ENERGY↗

H2@Scale CRADA: CA Research Consort. (Ref. Station, Fueling Perf. Test Device, Station Cap Model)

In support of DOE's H2@Scale initiative, this project leverages with national lab capabilities at SNL, NREL, and ANL with collaboration and funding cost share from California agencies (CEC, South Coast AQMD, and GO-Biz) to enable the build-out of heavy-duty (HD) hydrogen fueling stations with large dispensing capacity and high flow rates by providing tools and information that lead to more efficient design, acceptance, and commissioning. In this presentation, we describe the progress as related to the subtasks of: HD Reference Station Design, HD Station Test Device Design, and the Station Capacity Model.

AMR↗

Machine learning enhanced characterization and optimization of photonic cured MAPbI 3 for efficient perovskite solar cells

Photonic curing (PC) can facilitate high-speed perovskite solar cell (PSC) manufacturing because it uses high-intensity light pulses to crystallize perovskite films in milliseconds. However, optimizing PC conditions is challenging due to its many variables, and using power conversion efficiency (PCE) as the optimization metric is both time-consuming and labor-intensive. This work presents a machine learning (ML) approach to optimize PC conditions for fabricating methylammonium lead iodide (MAPbI 3 ) films by quantitatively comparing their ultraviolet-visible (UV-vis) absorbance spectra to thermal annealed (TA) films using four similarity metrics. We perform Bayesian optimization coupled with Gaussian process regression (BO-GP) to minimize the similarity metrics. Refining PC conditions using active learning based on BO-GP models, we achieve a PC MAPbI3 film with an absorbance spectrum closely matching a TA reference film, which is further verified by its crystalline and morphological properties. Thus, we demonstrate that the UV-vis absorption spectrum can accurately proxy film quality. Additionally, we use an AI-based segmentation model for a more efficient grain size analysis. However, when we use the optimized PC condition to fabricate PSCs, we find that interaction between MAPbI 3 and the hole transport layer (HTL) during PC critically degrades the PSC performance. By adding a buffer layer between the HTL and MAPbI 3 , the optimized PC PSCs produce a champion PCE of 11.8%, comparable to the TA reference of 11.7%. Using UV-vis similarity metrics instead of device PCE as the objective in our BO-GP method accelerates the optimization of PC processing conditions for MAPbI 3 films.

14 SOLAR ENERGY↗

MELCOR Code Change History: Revision 18019 to 21402

This document summarily provides brief descriptions of the MELCOR code enhancement made between code revision number 18019and 21440. Revision 18019 represents the previous official code release; therefore, the modeling features described within this document are provided to assist users that update to the newest official MELCOR code release, 21440. Along with the newly updated MELCOR Users’ Guide [2] and Reference Manual [3], users are aware and able to assess the new capabilities for their modeling and analysis applications.

97 MATHEMATICS AND COMPUTING↗

Integrated energy-water-land nexus planning to guide national policy: an example from Uruguay

Despite broad consensus on the benefits of a nexus approach to multi-sector planning, actual implementation in government and other decision-making institutions is still rare. This study presents an approach to conducting integrated energy-water-land (EWL) planning, using Uruguay as an example. This stakeholder-driven study focuses on assessing the EWL nexus implications of actual planned policies aimed at strengthening three of Uruguay's key exports (beef, soy, and rice), which account for more than 40% of total national export revenue. Five scenarios are analyzed in the study: a reference scenario, a climate impacts scenario, and three policy scenarios. The three policy scenarios include measures such as increasing the intensity of beef production while simultaneously decreasing emissions, increasing irrigated soybean production, and improving rice yields. This study supplements previous sector-specific planning efforts in Uruguay by conducting the first stakeholder-driven integrated multi-sector assessment of planned policies in Uruguay using a suite of integrated modeling tools. Key insights from the study are: as compared to a reference scenario, improving beef productivity could lead to cropland expansion (+30%) and significant indirect increases in water requirements (+20%); improving rice yields could lead to increases in total emissions (+3%), which may partially offset emissions reductions from other policies; expanding irrigated soy could have the least EWL impacts amongst the policies studied; and climate-driven changes could have significantly less impact on EWL systems as compared to human actions. The generalizable insights derived from this analysis are readily applicable to other countries facing similar multi-sector planning challenges. In particular, the study's results reinforce the fact that policies often have multi-sector consequences, and thus policies can impact one another's efficacy. Thus, policy design and implementation can benefit from coordination across sectors and decision-making institutions.

54 ENVIRONMENTAL SCIENCES↗

Code Validation of SAM Using Forced and Natural Circulation Data from NACIE-UP Benchmark

Heavy liquid metals (HLMs) are promising candidates as coolants of Generation IV fast reactors due to their thermophysical properties. In the last decade, experimental work has been proposed as part of research and development efforts to develop such systems. In this context, researchers from the Brasimone Research Center have conducted many experiments using the Natural Circulation Experiment Upgrade (NACIE-UP) facility to study the thermofluid dynamic behavior of HLMs in rod bundle configurations with or without wire wrappers. This facility consists of a rectangular loop operated with lead-bismuth eutectic. Sensors across the loop monitor relevant parameters, i.e. temperatures, heat transfer, and flow conditions. Here, in the present work, we carefully select published data from NACIE-UP to validate the System Analysis Module (SAM), a modern system analysis code developed at Argonne National Laboratory. We developed one SAM model using specifications of the facility geometry and materials existing in relevant papers and reports. On top of that, these references provided the boundary conditions for simulating natural circulation and forced convection experiments in either steady or transient conditions. The SAM model simulates five test cases with diverse operating conditions. Ultimately, the code is proven to predict temperatures and mass flow rates that closely match the experiments. The discrepancies between numerical predictions and diverse transients are limited to a few degrees Celsius, showcasing that SAM is well suited for analyzing nuclear systems relying on HLM coolants.

advanced reactors↗

Validation of the Community Land Model Version 5 over the Contiguous United States (CONUS) using in-situ and remote sensing datasets

The Community Land Model (CLM) is an effective tool to simulate the biophysical and biogeochemical processes and their interactions with the atmosphere. Although CLM Version 5 (CLM5) constitutes various updates in these processes, its performance in simulating energy, water and carbon cycles over the Contiguous United States (CONUS) at scales which land surface changes and hydrometeorological and hydroclimatological applications are more locally relevant is yet to be assessed. In this study, we conducted three simulations at 0.125? during 1979-2018 over the CONUS using different configurations of CLM, namely CLM5-biogeochemistry (CLM5BGC), CLM4.5BGC, and CLM5-satellite phenology (CLM5SP). We validated and compared their simulations against multiple remote-sensed and in-situ datasets. Overall, the parametric and structural updates (e.g., carbon cost for nitrogen uptake, variable soil thickness, dry surface layer) in CLM5 improve its ability in capturing terrestrial biogeochemical dynamics. The low evapotranspiration in CLM5BGC is associated with biases in simulating vegetation phenological characteristics rather than soil water limitations. The mismatch between CLM5BGC-simulated peak leaf area index and reference data can be attributed to CLM5BGC's inability in simulating phenology of trees and grasses. The differences between CLM-simulated irrigation and reference estimates can be attributed to differences between processes represented in models and in reality, and uncertainties in input and validation datasets. Evaluation against observations at small catchments suggest that hydrologic parameters needed to be calibrated to improve simulations of runoff, especially subsurface runoff. Additional efforts are needed to incorporate spatially-distributed plant phenology and physiology parameters and regional-specific agricultural management practices (e.g., planting, harvest).

54 ENVIRONMENTAL SCIENCES↗

Effect of electrode rinse solutions on the electrodialysis of concentrated salts

The data presented indicate that modest attention to the chemistry of the electrode rinse solution can yield as much as 56% improvement in process efficiency. When operating electrodialysis (ED) with salt concentrations greater than 10,000 mg/l (as NaCl) the amperage can be relatively high even at low voltages. To maximize the overall rate of ion transport from diluate to concentrate, there is a need to minimize resistances in the electrode cells since these can represent as much as 30% of the total resistances in the entire process and in this particular ED unit, represented resistance roughly equivalent to that within the membrane stack. This work describes the performance of a 10-cell pair, 200 cm 2 (0.02 m 2 ) per membrane, pilot ED unit operated in batch mode at 5 V potential. The feedstock to the stack was varied from 0.5% to 6% NaCl. Results from Volt-amp profiles (2.0–15 V) were used as the rationale for choosing the preferred electrode rinse solution, 90 g/l (kg/m 3 ) disodium sulfate at pH 12.5. The recommended solution of 30 g/l (kg/m 3 ) disodium sulfate at neutral pH was tested against stronger solutions (60, 90, and 120 g/l (kg/m 3 ) disodium sulfate) at neutral pH and with 1 g/l (kg/m 3 ) sodium hydroxide added to yield solutions at pH 12.5. There were stark differences in the performance of the ED unit between the solutions at pH 7 and those at pH 12.5. The slopes of the Volt-amp profiles improved indicating less resistance to ion flow at pH 12.5. Most of the difference can be attributed to the greater conductivity of sodium hydroxide compared to disodium sulfate, where even a modest addition of 1 g/l (kg/m 3 ) sodium hydroxide increased the conductivity of the solution between 8 and 20% depending on the concentration of disodium sulfate. Most notably, the initiation voltage was 2.39 ± 0.08 V with solutions at pH 7 and 1.99 V ± 0.04 V when the rinse solutions were around pH 12.5, a difference of around 0.42 V. Since the full batch runs were performed at 5.0 V, this 0.42 V differential represented a loss of 8% in process efficiency. A series of tests showed a shift in initiation voltage occurred between pH 11.5 and 12.5. Nernst equations for water electrolysis are coupled with a simple flux model that estimates the concentration of hydroxide and hydronium ions at the electrode surfaces. This model indicates that the potential demanded by the electrodes is directly linked to the current. Furthermore, there is a steep drop in the potential demanded by the anode when there is sufficient hydroxide available to generate oxygen from hydroxide as opposed to generation from water. The voltage demand is minimal at pH 12.5 and reflective of the reference standard voltage (just over 1.23 V predicted at 0.1 amps). However, the flux model predicts that the voltage demanded by the electrodes at pH 7 is 1.61 V at 0.1 amps (the lowest amperage measurable with the power pack). In conclusion, comparing this result to the reference standard (E 0 = -1.23 V) yields a satisfactory explanation for the observed difference below reference standard of 0.42 V.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

End-Use Savings Shapes Measure Documentation: Electric Cooking Equipment

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past three years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. “Measures” refers to energy efficiency variables that can be applied to buildings during modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cluster Expansion Analysis of Atomic Order in Li-Ion Battery Cathode Material LiCo y Ni 1-y O 2

A modified cluster-expansion treatment was developed recently to analyze atomic order in LiCo y Ni 1-y O 2 , a model cathode material for Li-ion batteries. In this treatment, referred to as a “spin-atom” cluster expansion, the occupant of a lattice site is identified by its spin state as well as its atomic species. Further, Effective Cluster Interaction (ECI) coefficients are derived from a large training data set (i.e., the set of atomic arrangements for which DFT calculations are performed) which is filtered by an anomaly detection algorithm to eliminate poorly converged DFT calculations. The cluster expansion incorporates Li-Ni (LN) exchange as well as intralayer Co-Ni (CN) exchange. Monte Carlo simulations based on the cluster expansion were applied to the Ni-rich part of the phase diagram. The simulations predict a miscibility gap between y = 0.05 and y = 0.65.

25 ENERGY STORAGE↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: LED Lighting

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a timeseries profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - LED lighting. The LED lighting measure replaces interior lights with LEDs where applicable. The measure resulted in 1.25 TBtu energy savings across the building stock, with the majority of savings occurring in retail and warehouse buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Economizers

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Electric Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock TM and ComStock TM models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure—boiler replacement by air-source heat pump boiler. This measure replaces space heating natural gas boilers by air-source heat pump boilers when applicable and helps quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 2.9. The total natural gas energy consumption was reduced by 20%, whereas the total electricity consumption was increased by 2.5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Natural Gas Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock (™) and ComStock (™) models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - boiler replacement with air-source heat pump boiler with natural gas boiler backup. This measure replaces natural gas boilers for HVAC application by air-source heat pump boilers when applicable and use natural gas boiler backup when the heat pump boiler could not operate due to outdoor air conditions which are below its cutoff temperature. This measure helps to quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 3. The total natural gas energy consumption was reduced by 41%, whereas the total electricity consumption was increased by 5.3%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NED_Asteroid_Energy_Deposition

In the event of a potentially catastrophic asteroid impact, with sufficient warning time, deploying a nuclear device remains a powerful option for planetary defense if a kinetic impactor proves insufficient. Predicting the effectiveness of a potential nuclear deflection or disruption mission depends on accurate multiphysics simulations of the device's x-ray energy deposition into the asteroid and the resulting material ablation. These simulations span many orders of magnitude, require a variety of different complex physics packages, and are computationally expensive. Having an efficient and accurate way of modeling this system is necessary for exploring a mission's sensitivity to the asteroid's range of physical properties. To expedite future simulations, we present a completed x-ray energy deposition model developed using the radiation-hydrodynamics code Kull which can be used to initiate a nuclear mitigation mission hydrocode. The model spans a wide variety of possible mission initial conditions: four different asteroid-like materials (Silicon Dioxide, Forsterite, Iron, and Ice), two different source spectra (1 and 2 keV blackbodies), and then a broad range of radiation fluences (0.0001 to 1 kt per square meter), source durations (10 to 100 ns), and asteroid porosities (0 to 80 percent). Using blowoff momentum as the primary metric, the modelinitiated simulation results match the full radiation-hydrodynamics results to within 10 percent. Please reference the journal article: Burkey et al., X-Ray Energy Deposition Model for Simulating Asteroid Response to a Nuclear Planetary Defense Mitigation Mission, Planetary Science Journal, (2023) for more information.

Managan, RobertA↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation, New Windows, LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility enduse load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. “Measures” refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Accelerating Ab Initio Simulation via Nested Monte Carlo and Machine Learned Reference Potentials

As a corollary of the rapid advances in computing, ab initio simulation is playing an increasingly important role in modeling materials at the atomic scale. Two strategies are possible, ab initio Monte Carlo (AIMC) and molecular dynamics (AIMD) simulation. The former benefits from exact sampling from the correct thermodynamic distribution, while the latter is typically more efficient with its collective all-atom coordinate updates. In this study, using a relatively simple test model comprised of helium and argon, we show that AIMC can be brought up to, and even above, the performance levels of AIMD via a hybrid nested sampling/machine learning (ML) strategy. Here, ML provides an accurate classical reference potential (up to three-body explicit interactions) that can pilot long collective Monte Carlo moves that are accepted or rejected in toto à la nested Monte Carlo (NMC); this is in contrast to the single move nature of a naive implementation. Our proposed method only requires a small up front expense from evaluating the ab initio energies and forces of (100) random configurations for training. Importantly, our method does not totally rely on the trained, assuredly imperfect, interaction. We show that high performance and exact sampling at the desired level of theory can be realized even when the trained interaction has appreciable differences from the ab initio potential. Remarkably, at the highest levels of performance realized via our approach, a pair of statistically uncorrelated atomic configurations can be generated with (1) ab initio calculations.

74 ATOMIC AND MOLECULAR PHYSICS↗