Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Testing a Model of IR Radiative Losses: Preprint

Thermopile pyranometers exhibit IR radiative losses that affect global and diffuse shortwave measurements made with first class thermopile based instruments. Pyrgeometers can be used to measure the sky temperature and are used to calculate the pyranometer?s IR radiative losses.

14 SOLAR ENERGY↗

A comparison of depth dependence of dose and linear energy transfer spectra in aluminum and polyethylene

A set of four tissue-equivalent proportional counters (TEPCs), with their detector heads at the centers of 0 (bare), 3, 7 and 9-inch-diameter aluminum spheres, were flown on Shuttle flight STS-89. Five such detectors at the centers of polyethylene spheres were flown 1 year earlier on STS-81. The results of dose-depth dependence for the two materials convincingly show the merits of using material rich in hydrogen to decrease the radiation exposure to the crew. A comparison of the calculated galactic cosmic radiation (GCR) absorbed dose and dose-equivalent rates using the radiation transport code HZETRN with nuclear fragmentation model NUCFRG2 and the measured GCR absorbed dose rates and dose-equivalent rates shows that they agree within root mean square (rms) error of 12.5 and 8.2%, respectively. However, there are significant depth-dependent differences in the linear energy transfer (LET) spectra. A comparison for trapped protons using the proton transport code BRYNTRN and the AP-8 MIN trapped-proton model shows a systematic bias, with the model underpredicting dose and dose-equivalent rates. These results show the need for improvements in the radiation transport and/or fragmentation models.

manned↗

Radiation Dose Reduction in CT Fluoroscopy-Guided Cervical Transforaminal Epidural Steroid Injection by Modifying Scout and Planning Steps

Background and PurposeIn CT fluoroscopy (CTF)-guided cervical transforaminal epidural steroid injection (TFESI), the majority of radiation dose is contributed by the planning CT scan rather than the CTF procedure itself. We replaced the planning helical CT with a spot CTF and accordingly changed the patient posture during scout and planning scans. The aim of this study was to test whether radiation dose reduction would be achieved by this protocol modification while still maintaining technical performance.MethodsOverall, 338 consecutive procedures before (control group: n = 163) and after (study group: n = 175) instituting the above-mentioned protocol modification were analyzed retrospectively, comparing patient characteristics (age, sex, neck diameter, and level injected) and technical performance [technical success rate, dose-length product (DLP), inadvertent contrast flow incidence, number of CTF acquisitions, and procedural time] between the two groups.ResultsAll injections were technically successful at every level from C3–C4 to C7–T1 without serious complications in both groups. The median DLP of the study group (7.92 mGy·cm) was significantly reduced compared to that of the control group (39.05 mGy·cm, P < 0.001). There were no significant differences between the two groups regarding the incidence of inadvertent contrast flow (20.6 vs. 17.2 %, P = 0.426), number of CTF acquisitions (median 5 vs. 4, P = 0.123), and the procedural time (median 6.62 vs. 6.90 min, P = 0.100).ConclusionsWhen conducting CTF-guided cervical TFESIs, a significant radiation dose reduction (median 79.7 % in DLP) can be achieved by modifying scout and planning steps, without compromising the technical performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The equivalence of three techniques for estimating ground reflectance from LANDSAT digital count data

The equivalence of three separate investigations that related LANDSAT digital count (DC) to ground measured reflectance (R) was demonstrated. One investigator related DC data to the cosZ, where Z is the solar zenith angle, for surfaces of constant R. The second investigator corrected the DC data to the solar zenith angle of 39 degrees before relating to surface R. Both of these investigators used LANDSAT 1 and 2 data from overpass dates 1972 through 1977. A third investigator calculated the relation between DC and R based on atmospheric radiative transfer theory. The equation coefficients obtained from these three investigators for all four LANDSAT MSS bands were shown to be equivalent although differences in ground reflectance measurement procedures have created coefficient variations among the three investigations. These relations should be useful for testing atmospheric radiative transfer theory.

Richardson, A. J.↗

Preparing for Mars: The Evolvable Mars Campaign 'Proving Ground' Approach

As the National Aeronautics and Space Administration (NASA) prepares to extend human presence beyond Low Earth Orbit, we are in the early stages of planning missions within the framework of an Evolvable Mars Campaign. Initial missions would be conducted in near-Earth cis-lunar space and would eventually culminate in extended duration crewed missions on the surface of Mars. To enable such exploration missions, critical technologies and capabilities must be identified, developed, and tested. NASA has followed a principled approach to identify critical capabilities and a "Proving Ground" approach is emerging to address testing needs. The Proving Ground is a period subsequent to current International Space Station activities wherein exploration-enabling capabilities and technologies are developed and the foundation is laid for sustained human presence in space. The Proving Ground domain essentially includes missions beyond Low Earth Orbit that will provide increasing mission capability while reducing technical risks. Proving Ground missions also provide valuable experience with deep space operations and support the transition from "Earth-dependence" to "Earth-independence" required for sustainable space exploration. A Technology Development Assessment Team identified a suite of critical technologies needed to support the cadence of exploration missions. Discussions among mission planners, vehicle developers, subject-matter-experts, and technologists were used to identify a minimum but sufficient set of required technologies and capabilities. Within System Maturation Teams, known challenges were identified and expressed as specific performance gaps in critical capabilities, which were then refined and activities required to close these critical gaps were identified. Analysis was performed to identify test and demonstration opportunities for critical technical capabilities across the Proving Ground spectrum of missions. This suite of critical capabilities is expected to provide the foundation required to enable a variety of possible destinations and missions consistent with the Evolvable Mars Campaign.. The International Space Station will be used to the greatest extent possible for exploration capability and technology development. Beyond this, NASA is evaluating a number of options for Proving Ground missions. An "Asteroid Redirect Mission" will demonstrate needed capabilities (e.g., Solar Electric Propulsion) and transportation systems for the crew (i.e., Space Launch System and Orion) and for cargo (i.e., Asteroid Redirect Vehicle). The Mars 2020 mission and follow-on robotic precursor missions will gather Mars surface environment information and will mature technologies. NASA is considering emplacing a small pressurized module in cis-lunar space to support crewed operations of increasing duration and to serve as a platform for critical exploration capabilities testing (e.g., radiation mitigation; extended duration deep space habitation). In addition, "opportunistic mission operations" could demonstrate capabilities not on the Mars critical path that may, nonetheless, enhance exploration operations (e.g., teleoperations, crew assisted Mars sample return). The Proving Ground may also include "pathfinder" missions to test and demonstrate specific capabilities at Mars (e.g., entry, descent, and landing). This paper describes the (1) process used to conduct an architecture-driven technology development assessment, (2) exploration mission critical and supporting capabilities, and (3) approach for addressing test and demonstration opportunities encompassing the spectrum of flight elements and destinations consistent with the Evolvable Mars Campaign.

Bobskill, Marianne R.↗

ASGRAD FY07 Annual Report

This is the annual project report for the ASGRAD project - Amorphous Semiconductors for Gamma Radiation Detection. We describe progress in the development of new materials for portable, room temperature, gammaradiation detection at Pacific Northwest National Laboratory. High Z, high resistivity, amorphous semiconductors are being designed for use as solid-state detectors at near ambient temperatures; their principles of operation are analogous to single-crystal semiconducting detectors. Compared to single crystals, amorphous semiconductors have the advantages of rapid, cost-effective, bulk-fabrication; nearnet-shape fabrication of complicated geometries; compositional flexibility; and greater electronic property control. The main disadvantage is reduced-charge carrier mobility. The focus of this project is to develop optimized amorphous semiconductor materials for gamma detection applications that leverage their material advantages while mitigating their limitations. During the second year of this project, several important milestones were accomplished. Major accomplishments were: (1) Significant processing - property and composition - property correlations were determined for Cd-Ge-As glasses; (2) Radiation response testing was successfully demonstrated on three different amorphous semiconductor materials (Cd-Ge-As, As-Se, and As-Se-Te systems) at ambient and near ambient temperatures; (3) Advanced, enabling Schottky contacts were developed for Cd-Ge-As compounds, this will allow these materials to perform at ambient temperatures; and (4) The collaborative working relationship developed with Prof. Angus Rockett at the University of Illinois at Urbana-Champaign (UIUC) has continued to grow, and they are credited with several of the materials characterization and contact development successes achieved this year. The development of Schottky barrier contacts in amorphous semiconductors by simply using different types of metal contacts is very significant. This is because these structures allow us to fabricate functional diodes using the Schottky barrier as the 'blocking' contact, similar to the familiar silicon surface barrier detector. In device terms, lower resistivity materials with better charge carrier mobility properties can be used and operated under reverse bias to create a low-noise, high-resistivity condition that can be switched to a low-resistivity, high conductivity condition under exposure to radiation events, and then off again. In the future, lithographic techniques could be used to create an array of FET's, and thereby build pixilated detectors that would have 2D position-sensitive radiation detection capability. Thus, the third year of the project will be dedicated to building diode-based devices from these amorphous semiconductors. The major challenges to date with the Schottky contacts have been a large variation in device behavior from contact to contact, and the relative fragility of the contacts. We are developing strategies to solve these issues. Additionally, particular emphasis will be directed towards characterizing device performance in response to ionizing radiation, which is key to demonstrating the viability of amorphous semiconductor-based detectors.

36 MATERIALS SCIENCE↗

Low velocity impact testing and nondestructive evaluation of transparent materials

Advanced transparent materials are used in protective systems for enhancing the survivability of ground vehicles, air vehicles, and personnel in applications such as face shields, riot gear, and vehicle windows. Low velocity impact damage can limit visibility and compromise the structural integrity of a transparent system, increasing the likelihood of further damage or penetration from a high velocity impact strike. For this reason, it is critical to determine damage tolerance levels of transparent systems to indicate whether or not a component should be replaced. In this study, transparent laminate systems will be tested by comparing baseline conditions to experimentally controlled damage states. Destructive testing including air gun and sphere impact testing will be used to replicate low velocity impacts in the field. Characterization of the damaged state will include basic visual inspection as well as nondestructive techniques including cross-polarization, x-ray, and ultrasound. The combination of destructive testing and characterization of the resulting damage can help to establish a damage acceptance criterion for materials used in protective systems.

42 ENGINEERING↗

SCEPTRE v. 2.0 (Sandia Computational Engine for Particle Transport for Radiat

SCEPTRE solves the linear Boltzmann transport equation for general one-, two- and three-dimensional unstructured-mesh Cartesian geometries. SCEPTRE can handle any particle type for which multigroup-Legendre cross sections are available. However, the code is designed primarily to model the transport of photons, electrons, and positrons through matter. SCEPTRE 2.0 includes several auxiliary packages for pre- and post-processing, regression testing, stochastic radiation transport, thermal radiation transport, and charged-particle transport in the presence of electromagnetic fields. SCEPTRE 2.0 includes sophisticated transport-synthetic acceleration and ray-effects mitigation capabilities.

Pautz, Shawn↗

Design and preliminary testing of a Brayton space radiator concept

A low-temperature radiator has been designed to reject 17.62 kW of thermal power from an isotope Brayton power system. This power system has an electrical output of 7.1 kW. The total radiator consists of two radiators connected in series. Both radiators have a redundant coolant loop, shared fins, and are close to flight configuration. A silicone oil is used as the working fluid. Low flow rates and moderate pressure drop in the radiator required a small hydraulic diameter with large heat transfer area and large flow area. To obtain these characteristics and meet schedule limitations, an expanded tube configuration (with an approximately trapezoidal cross section) was selected. Because of the low flow rates and unconventional tube shape, small scale tests were performed to evaluate the validity of existing heat transfer and pressure drop correlations to this case. The results of these tests were in good agreement with predictions.

Miller, T. J.↗

General Relativistic Implicit Monte Carlo Radiation-hydrodynamics

Abstract We report on a new capability added to our general relativistic radiation-magnetohydrodynamics code, Cosmos++ : an implicit Monte Carlo (IMC) treatment for radiation transport. The method is based on a Fleck-type implicit discretization of the radiation-hydrodynamics equations, but generalized for both Newtonian and relativistic regimes. A multiple reference frame approach is used to geodesically transport photon packets (and solve the hydrodynamics equations) in the coordinate frame, while radiation–matter interactions are handled either in the fluid or electron frames then communicated via Lorentz boosts and orthonormal tetrad bases attached to the fluid. We describe a method for constructing estimators of radiation moments using path-weighting that generalizes to arbitrary coordinate systems in flat or curved spacetime. Absorption, emission, scattering, and relativistic Comptonization are among the matter interactions considered in this report. We discuss our formulations and numerical methods, and validate our models against a suite of radiation and coupled radiation-hydrodynamics test problems in both flat and curved spacetimes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recent progress on the superconducting ion source VENUS

The 28 GHz Ion Source VENUS (versatile ECR for nuclear science) is back in operation after the superconducting sextupole leads were repaired and a fourth cryocooler was added. VENUS serves as an R and D device to explore the limits of electron cyclotron resonance source performance at 28 GHz with its 10 kW gryotron and optimum magnetic fields and as an ion source to increase the capabilities of the 88-Inch Cyclotron both for nuclear physics research and applications. The development and testing of ovens and sputtering techniques cover a wide range of applications. Recent experiments on bismuth demonstrated stable operation at 300 e{mu}A of Bi{sup 31+}, which is in the intensity range of interest for high performance heavy-ion drivers such as FRIB (Facility for Rare Isotope Beams). In addition, the space radiation effects testing program at the cyclotron relies on the production of a cocktail beam with many species produced simultaneously in the ion source and this can be done with a combination of gases, sputter probes, and an oven. These capabilities are being developed with VENUS by adding a low temperature oven, sputter probes, as well as studying the RF coupling into the source.

43 PARTICLE ACCELERATORS↗

Peculiar velocity field: Constraining the tilt of the Universe

A large bulk flow, which is in tension with the Lambda cold dark matter ({Lambda}CDM) cosmological model, has been observed. In this paper, we provide a physically plausible explanation of this bulk flow, based on the assumption that some fraction of the observed dipole in the cosmic microwave background is due to an intrinsic fluctuation, so that the subtraction of the observed dipole leads to a mismatch between the cosmic microwave background defined rest frame and the matter rest frame. We investigate a model that takes into account the relative velocity (hereafter the tilted velocity) between the two frames, and develop a Bayesian statistic to explore the likelihood of this tilted velocity. By studying various independent peculiar velocity catalogs, we find that (1) the magnitude of the tilted velocity u is around 400 km/s, and its direction is close to what is found from previous bulk flow analyses; for most catalogs analyzed, u=0 is excluded at about the 2.5{sigma} level; (2) constraints on the magnitude of the tilted velocity can result in constraints on the duration of inflation, due to the fact that inflation can neither be too long (no dipole effect) nor too short (very large dipole effect); (3) under the assumption of a superhorizon isocurvature fluctuation, the constraints on the tilted velocity require that inflation lasts at least 6 e-folds longer (at the 95% confidence interval) than that required to solve the horizon problem. This opens a new window for testing inflation and models of the early universe from observations of large scale structure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monte Carlo Radiation Transport for Astrophysical Transients Powered by Circumstellar Interaction

In this paper, we introduce SuperLite, an open-source Monte Carlo radiation transport code designed to produce synthetic spectra for astrophysical transient phenomena affected by circumstellar interaction. SuperLite utilizes Monte Carlo methods for semi-implicit, semirelativistic radiation transport in high-velocity shocked outflows, employing multigroup structured opacity calculations. The code enables rapid post-processing of hydrodynamic profiles to generate high-quality spectra that can be compared with observations of transient events, including superluminous supernovae, pulsational pair-instability supernovae, and other peculiar transients. We present the methods employed in SuperLite and compare the code's performance to that of other radiative transport codes, such as SuperNu and CMFGEN. We show that SuperLite has successfully passed standard Monte Carlo radiation transport tests and can reproduce spectra of typical supernovae of Type Ia, Type IIP, and Type IIn.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and Operation of a Calorimeter for Advanced Multilayer Insulation Testing

A calorimeter has been constructed to accurately measure insulation performance with a nominal 90K cold outer boundary and a 20K inner boundary. Unique features of this design include use of mechanical cryocoolers instead cryogens and measurement of the heat load with a calibrated rod to serve as a conduction path. The calorimeter is operational and has completed its first test series. The initial test series was designed to look for differences in performance between a single layer of aluminum foil and a sheet of double aluminized mylar (DAM). Although it has been speculated that the aluminum foil would perform better, since the mylar coating might not thick enough to stop the transmission of long wave length infrared radiation, our testing showed a higher heat load for the aluminum foil than the DAM. The aluminum foil showed a heat load of 132 mW at an 87 K outer temperature and 152 mW at a 107K outer temperature. Whereas the DAM showed a heat load of 66 mW at an 88 K outer temperature and 81 mW at 108 K.

Cryogenics↗

A simple method to quantify the coincidence between portal image graticules and radiation field centers or radiation isocenter

Purpose: The aim of this study was to develop a computerized method to quantify the coincidence between portal image graticules and radiation field centers or radiation isocenter. Three types of graticules were included in this study: Megavoltage (MV) mechanical graticule, MV electronic portal imaging device digital graticule, and kilovoltage (kV) on-board imaging digital graticule. Methods: A metal ball bearing (BB) was imaged with MV and kV x-ray beams in a procedure similar to a Winston-Lutz test. The radiation fields, graticules, and BB were localized in eight portal images using Hough transform-based computer algorithms. The center of the BB served as a static reference point in the 3D space so that the distances between the graticule centers and the radiation field centers were calculated. The radiation isocenter was determined from the radiation field centers at different gantry angles. Results: Misalignments of MV and kV portal imaging graticules varied with the gantry or x-ray source angle as a result of mechanical imperfections of the linear accelerator and its imaging system. While the three graticules in this study were aligned to the radiation field centers and the radiation isocenter within 2.0 mm, misalignments of 1.5-2.0 mm were found at certain gantry angles. These misalignments were highly reproducible with the gantry rotation. Conclusions: A simple method was developed to quantify the alignments of portal image graticules directly against the radiation field centers or the radiation isocenter. The advantage of this method is that it does not require the BB to be placed exactly at the radiation isocenter through a precalibrated surrogating device such as room lasers or light field crosshairs. The present method is useful for radiation therapy modalities that require high-precision portal imaging such as image-guided stereotactic radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗