Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Parametric optimization of PCM-enhanced underground thermal energy storage for buildings in moderate cold climates

This study presents a novel underground thermal energy storage (UTES) system designed for space heating in buildings located in moderate cold climates. The proposed UTES features a borehole with a depth of 25 ft. (7.62 m) and a diameter of 3 ft. (0.91 m), containing two helical pipe loops-one for discharge fluid and another for recharge fluid-and a thermally enhanced phase change material (PCM) layer that provides high energy storage capacity. The system requires daily thermal recharging using a low-grade heat source for a few hours and delivers continuous heating at a nearly constant discharge rate without significant performance degradation over a 24-h period. This study demonstrates that the optimized UTES, when recharged with hot fluid at an inlet temperature of 40 degrees C for 6 h daily, can provide a continuous heat discharge rate of approximately 2.9 kW for 24 h or 3.4 kW if operated under a shorter discharge period of 15 h (17:00-08:00). With a round-trip efficiency of 72-97%, the proposed UTES offers an efficient and reliable solution for short- and long-duration thermal energy storage technology, making it a promising technology for cold climates.

15 GEOTHERMAL ENERGY↗

Tracking carrier and exciton dynamics in mixed-cation lead mixed-halide perovskite thin films

Mixed-cation lead mixed-halide perovskites simultaneously possess structural stability and high power conversion efficiency. A thorough study of both carrier and exciton dynamics is needed to understand the photophysical properties that underpin its superior photovoltaic performance. By utilizing a broadband transient absorption spectroscopy, we observe the carrier and exciton dynamics in a FA 0.85 Cs 0.15 Pb(I 0.97 Br 0.03 ) 3 (FCPIB) perovskite by simultaneously resolving the carrier and exciton contribution to the transient change of the absorption spectra, from which the carrier density and exciton oscillator strength can be determined. Our data reveal a quick and significant conversion of the photogenerated carriers to excitons, on top of the usual carrier recombination process. Moreover, the decay of carrier density shows a change of kinetics from a second-order recombination at high pump fluence to a third-order recombination at low pump fluence. Our analysis utilizes band anharmonicity, presents an independent determination of electronic temperature and quasi-Fermi energy, and reveals an interesting interplay among the processes of carrier cooling, exciton formation/decay and carrier recombination, all as a function of time after photoexcitation. Our work demonstrates the use of pump fluence as a knob to tune the relative populations of carriers and excitons in halide perovskite materials.

36 MATERIALS SCIENCE↗

HERO WEC - Bills of Materials: WEC, RO System, and Submersible Pump

This submission includes detailed Bills of Materials for the NREL-designed and -built Hydraulic and Electric Reverse Osmosis Wave Energy Converter (HERO WEC), as well as the reverse osmosis assembly and submersible pump that are used in the HERO WEC. The WEC file is specific to the components and sub-components that are included on the in-water buoy portion of the WEC. The RO file is specific to the components and sub-components that are included on the reverse osmosis module that is used for both the hydraulic and electric configuration. The submersible pumps file is specific to the components and sub-components that are included on the submersible pump module that is used feed the reverse osmosis module when the HERO WEC is in the electric configuration. In addition to this submission, an additional submission available for the WEC model itself, including the power electronics enclosure, and reverse osmosis assembly that is needed to supply water in the electric submission. A link is provided below. More details on this project including data, CAD drawings, etc. can be found in the HERO-WEC main page link below. This data set has been developed by the National Renewable Energy Laboratory, operated by Alliance for Sustainable Energy, LLC, for the U.S. Department of Energy (DOE) under Contract No. DE-AC36-08GO28308. Funding provided U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Water Power Technologies Office.

16 TIDAL AND WAVE POWER↗

Energy Options Analysis Project (Final Report)

This Bear River Band of Rohnerville Rancheria (BRB) Energy Options Analysis Project provides a rigorous and comprehensive near-term renewable energy implementation plan that aligns with the BRB’s long term strategic vision of “zero net annual utility energy consumption.” Final recommendations were arrived at by following four key project phases:A gas and electricity load assessment was conducted for all existing buildings using historic consumption data, and projected loads of new or anticipated buildings using building designs. A renewable energy resource assessment was conducted that estimated the gross generation potential of solar and wind, constrained to areas that could potentially be developed. Other renewable generation technologies were not considered feasible to meet the loads of the BRB. Demand-side efficiency and fuel switching opportunities were identified that can reduce electrical and gas consumption. These opportunities were not integrated into the load assessment in order to provide a conservative implementation plan, but are recommended to be pursued in order to cost-optimize projects during a feasibility assessment. A strategic vision advisory committee was organized and consulted when iterating on the viability of possible projects. These project phases resulted in finalizing the following three solar PV projects for the near term, which also lay the foundation for a future community-scale or multiple-facility microgrid for added resiliency. Additional solar PV on the hillside south of the Tish-Non Community Center. Solar plus battery storage microgrid at the Pump & Play fuel station. Solar PV at the Casino.

14 SOLAR ENERGY↗

A Very High Temperature Lead Cooled Microreactor Concept using Advanced Materials and Thermophotovoltaics Direct Energy Conversion Technology

Recently, significant advances have been made in designing high-temperature capable nuclear fuels. In parallel, important advances have occurred in design of nanophotonic structures (coatings) with ability to shape the frequencies of light being emitted from hot surfaces. In this project, we bring these materials advances together into a design for a new direct conversion nuclear powered system with high thermodynamic efficiency, inherent safety, and unprecedented reduction in size and weight relative to current designs. The concept involves using the heat generated from nuclear fission to raise the temperature of a selective thermal emitter to >800°C. The selective emitter shifts the normal broad brand emissions of light from its hot surface into the correct near- and mid-IR bands that produce electricity with inexpensive photovoltaic cells. We have designed a new annular flow Lead Fast Reactor (LFR) that minimizes overall reactor/power conversion footprint. The results indicate that the overall microreactor/power-system design offers a 2X reduction in size over existing technology that is based on the sCO 2 reverse compression Brayton cycle. Additionally, the only moving part in our design is a circulation pump to cool the PVT panels.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characterization of a modified printed optical particle spectrometer for high-frequency and high-precision laboratory and field measurements

Abstract. The printed optical particle spectrometer (POPS) is a lightweight, low-cost instrument for measurements of aerosol number concentrations and size distributions. This work reports on modifications of the Handix Scientific commercial version of the POPS to facilitate its use in multi-instrument aerosol sampling systems. The flow system is modified by replacing the internal pump with a needle valve and a vacuum pump. The instrument is integrated into closed-flow systems by routing the sheath flow from filtered inlet air. A high-precision multichannel analyzer (MCA) card is added to sample the analog pulse signal. The MCA card is polled at 10 Hz frequency using an external data acquisition system and improves upon the count-rate limitation associated with the POPS internal data acquisition system. The times required to change the concentration between 90 % and 10 % and vice versa for a step change in concentration were measured to be 0.17 and 0.41 s at a flow rate of 5 cm3 s−1. This yields a sampling frequency of ∼ 1–2 Hz, below which the amplitude of measured fluctuations is captured with > 70 % efficiency. The modified POPS was integrated into the dual tandem differential mobility analyzer system to explore the coalescence of dimer particles. Results show that the pulse-height response increases upon dimer coalescence. The magnitude of the increase is broadly consistent with the change in light-scattering amplitude predicted by the T-matrix method. It is anticipated that this modified version of the POPS will extend the utilization of the technique for a range of field and laboratory applications.

54 ENVIRONMENTAL SCIENCES↗

The Levelized Cost of Exergy Framework

Exergy is the amount of energy within a substance or within a transfer of energy that can be used to produce work or some other useful output when interacting with some reference environment. Two different energy systems that produce the same output with the same exergetic efficiency must necessarily have the same amount of exergy input, even if the amount of energy input to the two systems is vastly different. For example, a low-grade heat-driven desalination would require far more energy input than a reverse osmosis (RO) plant producing the same amount of water, but if their exergetic efficiencies were the same, they would require the same amount of exergy input. Thus, comparisons between different energy sources on the basis of energy is not always appropriate. Instead, a comparison on a per unit exergy basis provides more insight on the cost-effectiveness of different energy sources and systems. In this presentation, we describe a framework for analyzing the levelized cost of exergy (LCOEx) for both inputs and outputs of various energy systems. Our framework illustrates how the cost per unit exergy of a system's energy source, as well as the exergetic efficiency of the system, greatly affect the cost of the system output. We use the levelized cost of electricity as a benchmark value for LCOEx, due to electricity's ubiquity as an energy source, and because it is relatively inexpensive on a per unit exergy basis. The LCOEx of various heat sources are then compared to the LCOEx of electricity. Medium- and high-grade industrial heat (> 150 degrees C) produced by natural gas tends to have an LCOEx on par with electricity. This is due to the low cost of natural gas, as well as the high exergy content of heat at higher temperatures. Meanwhile, low-grade heat tends to be an expensive exergy source, owing to the low exergy content of the low-grade heat. We first apply our framework to desalination, where RO has come to dominate, due to the low LCOEx of the energy source (electricity) and relatively high exergetic efficiency of RO compared to thermal desalination systems. We then use this framework to highlight an opportunity for dehumidification systems to experience a similar cost improvement as desalination has. If an electrically-driven, high exergetic efficiency dehumidification system were developed (such as the membrane-based dehumidification systems proposed in literature), it would use a low cost exergy source with a high exergetic efficiency and could potentially lower the cost of dehumidification in the way that RO has done for desalination. Finally, we apply our framework to various fuels (natural gas, hydrogen, gasoline, etc.) and energy systems across different sectors (desalination, dehumidification, vehicles, etc.) to understand the variation in the cost of exergy input and exergetic efficiency of different systems and technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design and Verification of An Open-Circuit Electro-Hydraulic Actuator System with An Integrated Electro-Hydraulic Unit

This paper proposes an electro-hydraulic actuator (EHA) system, and two novel-designed electro-hydraulic units (EHU) consisting of a fixed-displacement hydraulic pump and a variable-speed electric motor. Both the novel EHU designs integrate an electric machine and a hydraulic machine in a single unit, featuring compactness and power density. However, they differ for salient aspects such as power and electric machine cooling system. The EHA system features an open circuit design, where hydraulic hoses connect the EHU with a tank, a valve manifold, and the hydraulic cylinder. In this way, the proposed EHA technology can be used to implement distributed hydraulic actuation in a vehicle without requiring changes to the hydraulic actuators or at the overall layout of the hydraulic components with respect to the original vehicle design. A dedicated test rig is developed to verify the performance of the proposed EHA system. The efficiency of the EHA is measured in a steady state and under a realistic duty cycle of a commercial compact loader. The measured efficiency of the system can reach 54% with up to 20kN load and 6kW power level.

42 ENGINEERING↗

Action at a distance: The remarkable coupling of CO 2 uptake to electron transfer in specialized cyanobacterial NDH-1 complexes

Cyanobacteria achieve highly efficient photosynthesis using a CO 2 -concentrating mechanism relying on specialized Type I (NDH-1) complexes. Among these, NDH-1 3 and NDH-1 4 catalyze redox-coupled hydration of CO 2 to bicarbonate, supporting carbon fixation in carboxysomes. The mechanism of coupling electron transfer to CO 2 -hydration by these variant NDH-1 complexes remains unknown. We engineered a Synechococcus PCC7942 strain that expresses exclusively the high flux/low affinity NDH-14 complex, enabling the observation of the coupling of CO 2 hydration to cyclic electron flow in isolation from the other NDH-1 isoforms normally present in cells. We found that inhibition of the CupB protein by the carbonic anhydrase inhibitor ethoxzolamide (EZ) suppressed CO 2 uptake, slowed photosystem I rereduction, and abolished proton pumping as probed by acridine orange fluorescence. These effects were absent in strains lacking Cup proteins, confirming specificity. The results demonstrate that CO 2 hydration and electron transfer through NDH-14 are tightly coupled via proton translocation across the thylakoid membrane. These findings provide direct evidence for the bidirectional interaction in bioenergetic coupling between the plastoquinone reduction and the CO 2 uptake at the distal Zn-site over a span of ~150 Å and support a proton-removal hypothesis involving the proton transfer pathways from the Zn-site of CO2 hydration to an energetically coupled proton loading site evolutionarily repurposed from the ancestral proton pumping mechanism to enable energetic CO 2 uptake.

59 BASIC BIOLOGICAL SCIENCES↗

Magnetic anisotropy and spin scattering in (La 2/3 Sr 1/3 )MnO 3 /CaRuO 3 bilayers

Complex ferromagnetic oxides have been identified as possible candidate materials for sources of spin currents. Here we study bilayers of ferromagnetic (La 2/3 Sr 1/3 )MnO 3 (LSMO) and metallic CaRuO 3 (CRO) on LSAT substrates as a model system for spin pumping. Ferromagnetic resonance (FMR) measurements of these bilayers show evidence of spin pumping across the interface in the form of an increase in Gilbert damping with the addition of CRO. FMR indicates that the presence of CRO modifies the magnetic anisotropy of the LSMO. By increasing CRO thickness, we find a reduction of the out-of-plane anisotropy and simultaneous rotation of the easy axis within the plane, from the $\langle$110$\rangle$ to $\langle$100$\rangle$ axis. The evolution of magnetic anisotropy determined by FMR disagrees with that measured by bulk SQUID magnetometry and is accompanied by structural distortions in the LSMO layer as measured by x-ray diffraction, thus suggesting a change in magnetic anisotropy attributed to structural distortions imposed on LSMO by CRO. These results suggest that while LSMO and CRO remain promising candidates for efficient pure spin current generation and detection, respectively, epitaxial integration of perovskites will cause additional changes which must be accounted for in spintronics applications.

36 MATERIALS SCIENCE↗

Improvements in the Sample Space for the Backscattering Silicon Spectrometer (BASIS)

The increase in neutron flux at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS), currently operating at 2.0 MW proton beam power, has created new opportunities for higher-throughput neutron scattering experiments while also increasing the importance of minimizing background scattering and optimizing sample-environment operations. To address these challenges on the Backscattering Silicon Spectrometer (BA-SIS), several upgrades were developed and evaluated, including boron carbide (B₄C) masking for flat-plate sample containers, multi-cell sample holders used with a vertically translating sample stick, and an automated helium pump and purge (HPP) system for closed-cycle refrigerators. Neutron diffraction measurements demonstrate that B₄C masks reduce background scattering by 49–67%, outperforming both borated aluminum and boron nitride masks while introducing no additional Bragg reflections within the instrument’s accessible Q-range. Commissioning tests of a double-cell flat-plate sample contain-er showed no measurable crosstalk between adjacent sample compartments and con-firmed stable thermal performance, enabling multiple samples to be measured without re-peated temperature cycling. In addition, the automated HPP system provided reproducible sample-space gas handling with approximately ±1 mbar precision while reducing the need for operator intervention and supporting remote operation. Together, these developments improve signal-to-noise performance, increase experimental throughput, and enhance operational efficiency at BASIS, supporting the instrument’s continued operation under higher neutron flux conditions.

Jalarvo, Niina [ORNL] (ORCID:0000000306446866)↗

Characterization and controllability of radiated power via extrinsic impurity seeding in strongly negative triangularity plasmas in DIII-D

Experiments with extrinsic impurity seeding in strongly negative triangularity shapes in DIII-D achieved radiated power fractions (relative to input power) of up to ≈85% total radiation and ≈55% core radiation in steady-operating conditions. The relationship between core and total radiation was sensitive to impurity species and input power. Attempts to reach higher radiation levels via higher impurity flows resulted in radiative collapse disruptions. Nitrogen, neon, argon, and krypton were tested. Injection was by gas puffing, usually controlled by feeding back real-time estimates for core or total radiating fractions ($P_\textrm{rad} / P_\textrm{input}$). Argon and krypton were controlled by feeding back total radiating fraction, whereas neon was controlled by feeding back the core radiating fraction, due to the lower efficiency of neon as a divertor radiator. Nitrogen flows were pre-programmed. Reasonable total $P_\textrm{rad}$ control target following was achieved with argon or krypton. Control was more challenging with the neon/core radiation configuration, which was more prone to slow response and overshooting of the control target. Poor particle removal contributed to the control challenge: neon particle inventory within the last closed flux surface was roughly constant for up to 1 s (the longest duration tested) after neon injection was halted. However, separate experiments with laser-blow off of non-recycling impurities measured a short impurity confinement time, on the scale of the energy confinement time of ∼100 ms. Modeling with the Aurora impurity transport simulation matched experimental neon density profiles with full recycling (R = 1.0) and weak pumping but predicted rapid decreases in neon inventory if pumping were increased or recycling decreased. This indicates that changes outside the confined plasma (adding a well-placed pump) would improve controllability for all highly recycling species.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Atypical phase-change alloy Ga 2 Te 3 : atomic structure, incipient nanotectonic nuclei, and multilevel writing

Emerging brain-inspired computing, including artificial optical synapses, photonic tensor cores, neuromorphic networks, etc., needs phase-change materials (PCMs) of the next generation with lower energy consumption and a wider temperature range for reliable long-term operation. Gallium tellurides with higher melting and crystallization temperatures appear to be promising candidates and enable achieving the necessary requirements. Here, using high energy X-ray diffraction and Raman spectroscopy supported by first-principles simulations, we show that vitreous g-Ga 2 Te 3 films essentially have a tetrahedral local structure and sp 3 hybridization, similar to those in the stable fcc Ga 2 Te 3 polymorph and in contrast to a vast majority of typical PCMs. Nevertheless, optical pump–probe laser experiments revealed high-contrast, fast and reversible multilevel SET-RESET transitions raising a question related to the phase change mechanism. A recently observed nanotectonic compression in bulk glassy Ga–Te alloys seems to be responsible for the PCM performance. Incipient nanotectonic nuclei, reminiscent of monoclinic high-pressure HP-Te II and rhombohedral HP-Ga 2 Te 3 , are present as minorities (2–4%) in g-Ga 2 Te 3 but are suggested to grow dramatically with increasing temperature while interacting with appropriate laser pulses. This leads to co-crystallization of HP-polymorphs amplified by a high internal local pressure reaching 4–8 GPa. The metallic HP-forms provide an increasing optical and electrical contrast, favorable for reliable PCM operations, and higher energy efficiency.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Physically Realistic Estimates of Electric Water Heater Demand Response Resource

Multiple grid integration studies have examined the value of demand response, including from water heaters, to bulk power systems. Common shortcomings of these studies include physically unrealistic assumptions. For example, studies often assume that all electric water heater load can be shed for up to an hour to provide capacity or contingency service, that all electric water heater load is shiftable, and that round-trip efficiencies for shifting service are 100%. Another issue is that simply summing up estimates of individual water heaters' flexibility bounds, an attractive idea for constructing the MW-scale resources necessary for direct inclusion in grid investment and operational models, can result in significant overestimates of actual resource, because, e.g., a water heater with the ability to reduce load may not be able sustain the reduction for as long as the aggregate model suggests is possible. This presentation demonstrates the impact of estimating the flexibility of electric water heaters with physically realistic models suitable for grid service analysis. Electric water heater flexibility representations are constructed based on ResStock simulations of New England. Specifically, we examine contingency resource (related to capacity, shed, and contingency reserve services) and energy shifting resource from electric resistance and heat pump water heaters. Different estimation methods are compared; and the surrogate models' event responses are validated against events directly simulated in EnergyPlus. We also demonstrate the impact of using electric water heaters for contingency reserves and energy shifting in detailed models of possible future ISO New England power systems.

building energy modeling↗

End-Use Savings Shapes Upgrade Package Documentation: LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Light Emitting Diode (LED) Lighting, Heat Pump Rooftop Unit (RTU) (HP-RTU), and Air-Source Heat Pump (ASHP) Boiler, which we will refer to collectively as the "Interior Lighting and Heat Pump" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimal filtering and generation of entangled photons for quantum applications in the presence of noise

Filtering is commonly used in quantum optics to reject noise photons, and also to enable interference between independent photons. However, filtering the joint spectrum of photon pairs can reduce the inherent coincidence probability or loss-independent heralding efficiency. Here we investigate filtering for multiphoton applications based on entanglement and interference (e.g., quantum teleportation). We multiplex C-band entangled photons and C-band classical communications into the same long-distance fibers, which enables scalable low-loss quantum networking but requires filtering of spontaneous Raman scattering noise from classical light. Using tunable-bandwidth filters, low-jitter detectors, and polarization filters, we distribute wavelength-degenerate time-bin entangled photons in the C band (1536.5 nm) over 25 km/25 km standard fibers (50 km) each carrying 10 Gbit/s C-band classical data signals. Narrow filtering enables milliwatt-level C-band power, which exceeds the power achieved by comparable studies by roughly an order of magnitude and could feasibly support terabit per second classical rates. We evaluate how performance depends on pump and filter bandwidths, multipair emission, filter shapes, loss, phase matching, and how quantum information is measured. We find a trade-off between reducing noise impact and increasing single-mode purity, and discuss mitigation methods toward optimal multiphoton applications. Importantly, these results apply to noise in free space and in quantum devices (sources, frequency converters, switches, detectors, etc.) and provide insight into filter-induced degradation of single-photon purity and rates even in noise-free environments.

Thomas, Jordan M. [Fermilab; Northwestern U.]↗

A Modeling Tool to Analyze the Performance of Industrial Cooling Towers

Energy efficiency and energy savings have become an important factor as industries look for ways to save energy and minimize their energy consumption while reducing their carbon footprint. Cooling towers are utilized significantly in industries for either serving chillers or process cooling. Depending on the size of the cooling tower, it can use a surprising amount of energy and water, which is why it is crucial to make sure that the facility has optimized their cooling tower.A modeling tool has been developed to perform a thorough analysis of a cooling tower and its various operations to ensure that the facility has optimized its cooling tower. This model analyzes an annual base case in comparison with the revised case of a cooling tower operation. This modeling tool simulates 8,760 hourly calculations for fan power for various fan controls, water consumption, and pumping energy consumption and demand based on the user’s location and its corresponding Typical Meteorological Year 3 (TMY3) weather data. This model is capable to simulate up to five cooling tower cells as one large tower utilizing one pump or parallel pumping. The successful validated cooling tower model should assist industry to save energy at their facility through their cooling tower, whether they use it for process cooling or heating, ventilation and air conditioning (HVAC) applications. The entering/leaving water temperatures based on a monthly operating schedule or a wet-bulb temperature schedule will be used as inputs, and the model can calculate savings in energy for various conditions including variable-frequency drive (VFD) on the fan/pump, drift eliminators, number of cycles of concentration, reduced water flow rate, etc.

Hooper, Josh↗

Machine learning modeling and model predictive control of a closed-circuit reverse osmosis system

Closed-circuit reverse osmosis (CCRO) offers a flexible and energy-efficient alternative to conventional reverse osmosis by operating in a semi-batch mode that recycles brine, enabling higher recovery rates and reduced specific energy consumption (SEC). However, developing accurate, system-level dynamic models for CCRO remains challenging due to its nonlinear, multi-phase operation and sensitivity to variable feed water conditions. Traditional modeling approaches, such as NARMAX (nonlinear autoregressive moving average with exogenous inputs), often struggle to generalize across varying inlet feed concentrations, necessitating frequent parameter re-estimation and limiting their utility for real-time control applications. To address these limitations, we developed a long short-term memory (LSTM) neural network model trained on an extensive experimental data set from a CCRO pilot plant. The model accepts three inputs, feed flow rate, recirculation flow rate, and initial feed conductivity, and predicts three key outputs: reject conductivity, feed pump power draw, and recirculation pump power draw. We validated the LSTM model against experimental data, demonstrating its ability to distinguish between different feed conductivities and adapt to variable flow rates. Subsequently, we incorporated the LSTM model within a nonlinear model predictive control (MPC) scheme and conducted closed-loop simulations to optimize the integrated SEC (iSEC). In conclusion, the results project up to a 6% reduction in iSEC by using MPC to optimize performance over the entire experiment duration, without requiring any random excitation for data collection or parameter re-estimation.

Desalination↗