Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “portability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Portable unit for metabolic analysis

A portable unit for metabolic analysis includes a manifold in fluid communication with a mouth of a test subject. A conduit extends from the manifold and defines a flow channel through which the breaths of the test subject travels. A carbon dioxide sensor is attached to the conduit. The carbon dioxide sensor includes an intermediate support housing enclosing a volume disposed along the flow channel to define a first part of the flow channel, an inner support housing attached to a first side of the intermediate support housing, a plurality of IR LEDs mounted to an interior surface of the inner support housing, an outer support housing attached to a second side of the intermediate support housing, and a photodetector attached to the outer support housing. The photodetector faces the flow channel and receives IR radiation emitted by the plurality of LEDs.

Dietrich, Daniel L.↗

m-CUBES An efficient and portable implementation of multi-dimensional integration for gpus

The task of multi-dimensional numerical integration is frequently encountered in physics and other scientific fields, e.g., in modeling the effects of systematic uncertainties in physical systems and in Bayesian parameter estimation. Multi-dimensional integration is often time-prohibitive on CPUs. Efficient implementation on many-core architectures is challenging as the workload across the integration space cannot be predicted a priori. We propose m-Cubes, a novel implementation of the well-known Vegas algorithm for execution on GPUs. Vegas transforms integration variables followed by calculation of a Monte Carlo integral estimate using adaptive partitioning of the resulting space. m-Cubes improves performance on GPUs by maintaining relatively uniform workload across the processors. As a result, our optimized Cuda implementation for Nvidia GPUs outperforms parallelization approaches proposed in past literature. We further demonstrate the efficiency of m-Cubes by evaluating a six-dimensional integral from a cosmology application, achieving significant speedup and greater precision than the CUBA library's CPU implementation of VEGAS. We also evaluate m-Cubes on a standard integrand test suite. m-Cubes outperforms the serial implementations of the Cuba and GSL libraries by orders of magnitude speedup while maintaining comparable accuracy. Our approach yields a speedup of at least 10 when compared against publicly available Monte Carlo based GPU implementations. In summary, m-Cubes can solve integrals that are prohibitively expensive using standard libraries and custom implementations. A modern C++ interface header-only implementation makes m-Cubes portable, allowing its utilization in complicated pipelines with easy to define stateful integrals. Compatibility with non-Nvidia GPUs is achieved with our initial implementation of m-Cubes using the Kokkos framework.

Sakiotis, Ioannis↗

Studying Performance Portability of LAMMPS across Diverse GPU-based Platforms

The molecular dynamics simulation software, LAMMPS, utilizes the Kokkos acceleration library to port computation to a diverse set of architectures including those based on GPU accelerators. In addition to Kokkos, LAMMPS contains a vast code base that leverages the CUDA application programming interface using library functions such as cuFFT, CUDA’s fast-fourier transform (FFT) library, and, more recently, also support for AMD’s Heterogeneous Interface for Portability (HIP) that is rapidly growing. While preparing LAMMPS tests for the AMD GPU-based test system precursors to Frontier, we investigated several strategies for accelerating LAMMPS on AMD GPUs, using the AMD Instinct MI100 and MI250X. In this work, we integrated the HIP FFT library, hipFFT, into the particle-particle particle-mesh (PPPM) long-range solver, which allowed the porting of PPPM calculations to the GPUs. Kokkos behavior on the MI100 and MI250X was also investigated through the package kokkos command of LAMMPS, targeting com- munication, memory usage, and particle grid decomposition. The Tersoff, Reax, Lennard-Jones (LJ), EAM, Granular, and PPPM potentials were investigated in this effort, and results from these experiments are provided. The selected potentials were run on Spock (AMD Instinct MI100), Crusher (AMD Instinct MI250X), AFW HPC11 (NVIDIA A100) and Summit (NVIDIA V100), for comparison. Operational roofline models were constructed and analyzed for the Tersoff, Reax, and Lennard-Jones potentials on Crusher and Summit.

Hagerty, Nick↗

Development and evaluation of a portable CZT coded aperture gamma-camera

We present the design and the evaluation of a CdZnTe (CZT) based gamma camera using a coded aperture mask. This camera, based on a 8 cm{sup 3} detection module, is small enough to be portable and battery-powered (4 kg weight and 4 W power dissipation). As the detector has spectral capabilities, the gamma camera allows isotope identification and colored imaging, by affecting one color channel to each identified isotope. As all data processing is done at real time, the user can directly observe the outcome of an acquisition and can immediately react to what he sees. We first present the architecture of the system, how the detector works, and its performances. After, we focus on the imaging technique used and its strengths and limitations. Finally, results concerning sensitivity, spatial resolution, field of view and multi-isotope imaging are shown and discussed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FPGA-based prototype of portable environmental radiation monitor

This new portable radiological environmental monitor consists of 2 main components, Gamma ionization chamber and a FPGA-based electronic enclosure linked to convivial software for treatment and analyzing. The HPIC ion chamber is the heart of this radiation measurement system and is running in range from 0 to 100 mR/h, so that the sensitivity at the output is 20 mV/μR/h, with a nearly flat energy response from 0,07 to 10 MEV. This paper presents a contribution for developing a new nuclear measurement data acquisition system based on Cyclone III FPGA Starter Kit ALTERA, and a user-friendly software to run real-time control and data processing. It was developed to substitute the older radiation monitor RSS-112 PIC installed in CNESTEN's Laboratory in order to improve some of its functionalities related to acquisition time and data memory capacity. As for the associated acquisition software, it was conceived under the virtual LabView platform from National Instrument, and offers a variety of system setup for radiation environmental monitoring. It gives choice to display both the statistical data and the dose rate. Statistical data shows a summary of current data, current time/date and dose integrator values, and the dose rate displays the current dose rate in large numbers for viewing from a distance as well as the date and time. The prototype version of this new instrument and its data processing software has been successfully tested and validated for viewing and monitoring the environmental radiation of Moroccan nuclear center. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Portable Quantitative High-Resolution Gamma System for In-Situ Waste, D and D, and Emergency Measurements - 18573

The Canberra ISOCS system has been a highly successful and technologically innovative product since its introduction about 22 years ago. The combination of field-portable HPGe detectors, flexible shield/collimator set, and accurate mathematical efficiency calibration software made in-situ gamma spectroscopy measurements very practical. Good quality in-situ measurements are economically beneficial for items that are either large or complex, in comparison to the cost, time and impracticality of extracting a sample for laboratory measurements or producing representative calibration standards. And where the item is not homogeneous [most of the time for in-situ measurement situations] an assay of a large part of the item has been shown to be more accurate than a few widely dispersed extracted samples [the normal case]. However the size, weight, cost and complexity of the full-size ISOCS system limit its usefulness in some situations. A companion device was recently introduced, and is the subject of this document. The gamma sensor is a 1 cm{sup 3} CZT detector. It is surrounded by an optional tungsten shield/collimator set with a tripod for support. The detector is powered solely by a USB connection from a laptop PC. The full power of the ISOCS efficiency calibration software can be used with this detector. This entire package is less than 15 kg, needs no cooling, and is quite rugged, in comparison to the 120 kg for ISOCS with sensitive HPGe detectors which need Liquid Nitrogen or electro-mechanical cooling. Furthermore this CZT package is about 1/3 the cost. This is a very complementary device for the many current ISOCS users, especially for quick initial evaluations or simple situations where the full energy resolution and sensitivity of the HPGe ISOCS are not needed. Operating nuclear power plants or those in the initial phases of decommissioning are prime examples. Their complex layout often precludes the deployment of the full-sized ISOCS system, whereas the CZT system can be hand-carried there and very quickly setup for a measurement. The small detector size, and therefore low efficiency, is not a disadvantage, and in many cases is an advantage due to the elevated radioactivity of the items. This can be used to assay items in tanks, spills on floors, activity on filters, waste or items in small containers, and waste in drums. In the event of an emergency, it can be quickly deployed to measure gas or liquid effluent streams, air particulate and iodine filters in the field, or even in-vivo thyroid activity. Examples of measurements at nuclear facilities are shown and discussed in further detail, along with estimated detection limits. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrating human factors issues into critical portable detection usage - 121

There are multiple situations where portable detection systems are used to quantify distributed radionuclides. Such applications include holdup measurements in decommissioning activities, other routine usage and safeguards applications. Human factors dominate equipment deployment and operation and have significant impact upon the resulting data collection and its quality. Equipment use includes simultaneous positioning and targeting the object/region being quantified, observation and reporting of incoming data, often in difficult conditions and often while dressed in protective equipment. We examine the human interface with the equipment and other human factors where balance, perception, situational awareness and personnel health level influence the physical control and positioning of the detector. All these aspects impact both the measurement outcome and the Total Measurement Uncertainty (TMU). In this work, we are developing approaches and solutions to: 1. Initiate an inclusive program to assess and evolve human factors aspects of the interface to provide real time feedback tailored to a specific field operator profile. 2. Develop a measurement system human interface on a 'bench top' detection system to allow for both audio and visual I/O for auditory attention and situational (objective and subjective) awareness across varied end user characteristics. 3. Assess and develop an enhanced health assessment plan to identify and monitor pertinent auditory and balance characteristics for operator(s) interface and physical control of the gamma detector. Use the plan to verify personnel ability for effective deployment. We take a multidisciplinary approach to maximize accuracy, efficiency, and safety for the end-user to optimize project and measurement performance. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Performance Portable Non-Equilibrium Plasma Fluid Solver on Adaptive Grids

This presentation will describe the numerical techniques, programming paradigms, verification, and performance of a non-equilibrium plasma fluid solver that can effectively utilize current and upcoming central processing and graphics processing unit (CPU+GPU) architectures. Our plasma fluid model solves the conservation equations for self-consistent electrostatic Poisson, electron and heavy species transport, and electron temperature on adaptive Cartesian grids. Our solver is written using performance portable adaptive mesh management library, AMReX (Zhang et al., JOSS, 4 (37) 1370, 2019), and can be built and run on widely available vendor specific GPU architectures (NVIDIA/AMD/Intel). We utilize a non-subcycled second order semi-implicit time-stepping method where all adaptive mesh refinement (AMR) levels are advanced with the same time step. The composite multi-level multigrid solver from within AMReX is used for each of the governing equations that are cast into a Helmholtz equation form. We have also developed a python based chemical mechanism parser framework that uses a similar format as CANTERA (Goodwin et al., Zenodo, 2018) yaml files as input. Our custom parser reads the yaml file and provides C++ files with transport and production rate functions that can be executed on both host (CPU) and device (GPU). We present verification of our solver using method of manufactured solutions that indicate formal second order accuracy with central diffusion and fifth order weighted-essentially-non-oscillatory (WENO) advection scheme. We also verify our solver with published literature on low-pressure capacitive and high-pressure streamer discharges. Our initial performance studies indicate 10X speed-up using 20 NVIDIA GPUs versus 200 CPUs for an atmospheric streamer discharge problem solved on a 512 x 1024 x 512 grid.

graphics processing units↗

Portable self-contained pressure testing manifold and associated methods

A portable, case-enclosed pressure test manifold, configured to support both pneumatic and hydrostatic pressure testing, and comprising a downstream fluid path (e.g., a system test gauge, a ball valve, a system test port, a system relief valve, and other components/piping) and an upstream fluid path (e.g., a low-pressure gauge, a high-pressure gauge, and other components/piping). A regulator and/or the ball valve selectively operate the downstream fluid path, defining a hydrostatic pressure testing path, to receive a liquid; and the upstream fluid path in combination with the downstream fluid path, defining a pneumatic pressure testing path, to receive a gas. Manifold components are pressure rated based on use and are ASME Code B31.3 compliant. A flexible hose connects with either of the pneumatic pressure testing path and the hydrostatic pressure testing path of the manifold. The case includes parking receptables and a carrying handle configured to stow the hose during transport.

Milholland, Roger A.↗

Portable MRI [Slides]

This project proposes to: (1) provide the power of MRI to situations where it presently isn't available; (2) perform the engineering required to move from lab to a functional prototype; and (3) leverage significant existing infrastructure and capability in ultra-low field MRI. The reasons for doing this: (1) MRI is the most powerful tool for imaging soft-tissue (e.g. brain); (2) Billions don't have access due to cost or safety issues; (3) metal will heat/move in high magnetic fields; (4) Millions of cases of traumatic brain injury in US alone; (5) even more of non-traumatic brain injury; (6) (e.g. stroke, infection, chemical exposure); (7) Need for early diagnostic; (8) 'Signature' wound of recent conflicts; (9) 22% of injuries; (10) Implications for post-traumatic stress disorder; and (11) chronic traumatic encephalopathy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using Field-Metered Data to Quantify Annual Energy Use of Residential Portable Unit Dehumidifiers

The U.S. Energy Information Administration (EIA) reports that space heating and cooling no longer account for the majority of all residential energy consumption (they represented 47.7 percent in 2009). According to EIA, energy consumption for appliances, lighting, and electronics not only represents the majority of residential consumption, but continues to rise. Some of the decline in energy use for space heating and cooling may be attributable to better-insulated structures and population shifts to warmer climates. Those same factors may be contributing to an increased reliance on space-conditioning appliances, specifically dehumidifiers. Additionally, as the world’s climate changes, it is expected that absolute humidity will rise along with temperature. A recent study reports that continued climate warming will place significant limitations on human activity in typically hotter, more humid environments. Increased human discomfort may drive an even greater use of dehumidifiers and a resulting increase in residential energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Towards Portable Laser Desorption Postionization Mass Spectrometry Utilizing Microchip Laser Pulses

A 355 nm, 1.5 ns, up to 1 kHz microchip laser system has been tested to both yield ablation spots and postionize material within a plasma plume. A 30 µJ pulse energy microchip laser successfully ablated all samples: 6601 aluminum, 316 and 304 stainless steel, and Mo metal. While visible ablation craters were observed on all samples mentioned above, the stainless-steel samples displayed visible color changes in the resolidified iron, indicating ionization with the 355 nm pulses during ablation. Additionally, when used to intercept a plasma plume of Cs 2 CO 3 made with a separate laser system, the microchip laser pulses yielded Cs + emission signal otherwise not observed. With these experiments completed, the microchip laser has been successfully verified for readiness to be integrated into the front end of a mass spectrometer system as the ion source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Portable Miniature Cryogenic Environment for In Situ Neutron Diffraction

Neutron diffraction instruments offer a platform for materials science and engineering studies at extended temperature ranges far from ambient. As one of the widely used neutron sample environment types, cryogenic furnaces are usually bulky and complex, and they may need hours of beamtime overhead for installation, configuration, cooling, and sample change, etc. To reduce the overhead time and expedite experiments at the state-of-the-art high-flux neutron source, we developed a low-cost, miniature, and easy-to-use cryogenic environment (77–473 K) for in situ neutron diffraction. A travel-size mug serves for the environment where the samples sit inside. Immediate cooling and an isothermal dwell at 77 K are realized on the sample by direct contact with liquid N 2 in the mug. The designed Al inserts serve as the holder of samples and heating elements, alleviate the thermal gradient, and clear neutron pathways. Both a single-sample continuous measurement and multi-sample high-throughput measurements are demonstrated in this environment. High-quality and refinable in situ neutron diffraction patterns are acquired on model materials. The results quantify the orthorhombic-to-cubic phase transformation process in LiMn 2 O 4 and differentiate the anisotropic lattice thermal expansions and bond length evolutions between rhombohedral perovskite oxides with composition variation.

47 OTHER INSTRUMENTATION↗