Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “point spread functions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Multilevel Bayesian Inference for Cosmic Shear

The software implements a probabilistic hierarchical pipeline for inferring the gravitational lensing shears of galaxy images in the presence of noise, pixelated images, and astrophysical uncertainties. The distinct software components implement forward modeling of CCD images of galaxies and hierarchical inference of properties of the galaxy distribution and telescope Point Spread Functions (PSFs). We also include scripts to make diagnostic plots from the output files of each stage of the pipeline.

Bard, Deborah↗

Sandia Strehl Calculator Version 1.0

The Sandia Strehl Calculator is designed to calculate the Gibson and Lanni point spread function (PSF), Strehl ratio, and ensquared energy, allowing non-design immersion, coverslip, and sample layers. It also uses Abbe number calculations to determine the refractive index at specific wavelengths when given the refractive index at a different wavelength and the dispersion. The primary application of Sandia Strehl Calculator is to determine the theoretical impacts of using an optical microscope beyond its normal design parameters. Examples of non-design microscope usage include: a) using coverslips of non-design material b) coverslips of different thicknesses c) imaging deep into an aqueous sample with an immersion objective d) imaging a sample at 37 degrees. All of these changes can affect the imaging quality, sometimes profoundly, but are at the same time non-design conditions employed not infrequently. Rather than having to experimentally determine whether the changes will result in unacceptable image quality, Sandia Strehl Calculator uses existing optical theory to determine the approximate effect of the change, saving the need to perform experiments.

Anthony, Stephen M↗

Quantifying Uncertainties through Advanced Theoretical Analysis for Image and Signal Reconstruction NLV-02-15, Year 1 of 2

Presentation describes project to (1) adapt accelerated matrix-free linear system solvers for applying new statistical approaches to very large–scale problems, (2) characterize the degree to which new statistical methods are superior to classical methods in respect to the sensitivity to “tuning parameters,” and (3) develop a new mathematical theory and associated numerical methods for computing the point spread function of an x-ray imaging system.

97 MATHEMATICS AND COMPUTING↗

Monte Carlo Control Loops for Cosmic Shear Cosmology with DES Year 1

Weak lensing by large-scale structure is a powerful probe of cosmology and of the dark universe. This cosmic shear technique relies on the accurate measurement of the shapes and redshifts of background galaxies and requires precise control of systematic errors. The Monte Carlo Control Loops (MCCL) is a forward modelling method designed to tackle this problem. It relies on the Ultra Fast Image Generator (UFig) to produce simulated images tuned to match the target data statistically, followed by calibrations and tolerance loops. We present the first end-to-end application of this method, on the Dark Energy Survey (DES) Year 1 wide field imaging data. We simultaneously measure the shear power spectrum $C_{\ell}$ and the redshift distribution $n(z)$ of the background galaxy sample. The method includes maps of the systematic sources, Point Spread Function (PSF), an Approximate Bayesian Computation (ABC) inference of the simulation model parameters, a shear calibration scheme, and the fast estimation of the covariance matrix. We find a close statistical agreement between the simulations and the DES Y1 data using an array of diagnostics. In a non-tomographic setting, we derive a set of $C_\ell$ and $n(z)$ curves that encode the cosmic shear measurement, as well as the systematic uncertainty. Following a blinding scheme, we measure the combination of $\Omega_m$, $\sigma_8$, and intrinsic alignment amplitude $A_{\rm{IA}}$, defined as $S_8D_{\rm{IA}} = \sigma_8(\Omega_m/0.3)^{0.5}D_{\rm{IA}}$, where $D_{\rm{IA}}=1-0.11(A_{\rm{IA}}-1)$. We find $S_8D_{\rm{IA}}=0.895^{+0.054}_{-0.039}$, where systematics are at the level of roughly 60\% of the statistical errors. We discuss these results in the context of earlier cosmic shear analyses of the DES Y1 data. Our findings indicate that this method and its fast runtime offer good prospects for cosmic shear measurements with future wide-field surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Single-Shot Diagnostics of Microbunched Electrons in Laser-Driven Plasma Accelerators and Free-Electron Lasers

aThe need for single-shot diagnostics of the periodic longitudinal density modulation of relativistic electrons at the resonant wavelength (microbunching) in a free-electron laser (FEL) or at broadband visible wavelengths as in a laser-driven plasma accelerator (LPA) has been reaffirmed. In the self-amplified spontaneous emission (SASE) FEL case, statistical fluctuations in the microbunching occur in the startup- from-noise process. In the LPA, the plasma itself is chaotic and varies shot to shot. Fortunately, we have shown that coherent optical transition radiation (COTR) techniques, can assess beam size, divergence, spectral evolution, and z-dependent gain (100,000) of microbunched electrons in a past SASE FEL experiment at 530 nm*. Recently, the application to LPAs has been demonstrated with single-shot near-field (NF) and far-field (FF) COTR imaging done at the exit of an LPA for the first time**. In this case few-micron beam sizes and extensive fringes due to su b-mrad divergences were measured based on point-spread-function effects and an analytical model for COTR interferometry (COTRI), respectively. A new COTR-based diagnostics application to pre-bunched electron beams formed by co-propagating a laser pulse and the electron pulse in a short undulator (modulator) is also described.

43 PARTICLE ACCELERATORS↗

An Approach to Characterizing Spatial Aspects of Image System Blur

In imaging applications, such as X-ray radiography, the experimental system setup and data capture process introduce system blur and distortion. In images taken with thick scintillators, a spatially varying system blur is observed, requiring a nonstandard approach to blur and distortion estimation and removal. We demonstrate an approach to estimation of local point spread functions using checkerboard radiographs collected at the Naval Research Laboratory and extend that into a map defining the kernel over the camera field of view.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of pseudo-random binary arrays for calibration of surface profile metrology tools

Optical Metrology tools, especially for short wavelength (EUV and X-Ray), must cover a wide range of spatial frequencies from the very low, which affects figure, to the important mid-spatial frequencies and the high spatial frequency range, which produces undesirable scattering. A major difficulty in using surface profilometers arises due to the unknown Point-Spread Function (PSF) of the instruments [1] that is responsible for distortion of the measured surface profile. Generally, the distortion due to the PSF is difficult to account because the PSF is a complex function that comes to the measurement via the convolution operation, while the measured profile is described with a real function. Accounting for instrumental PSF becomes significantly simpler if the result of measurement of a profile is presented in a spatial frequency domain as a Power Spectral Density (PSD) distribution [2]. For example, the measured PSD distributions provide a closed set of data necessary for three-dimensional calculations of scattering of light by the optical surfaces [3], [4]. The distortion of the surface PSD distribution due to the PSF can be modeled with the Modulation Transfer Function (MTF), which is defined over the spatial frequency bandwidth of the instrument [1], [2]. The measured PSD distribution can be presented as a product of the squared MTF and the ideal PSD distribution inherent for the System Under Test (SUT). Therefore, the instrumental MTF can be evaluated by comparing a measured PSD distribution of a known test surface with the corresponding ideal numerically simulated PSD. The square root of the ratio of the measured and simulated PSD distributions gives the MTF of the instrument. In previous work [5], [6] the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on Binary Pseudo-Random (BPR) gratings. Here, we present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as Global Position System, and wireless communication protocols. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the Uniformly Redundant Array prescription [7] initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat PSD. Three different size BPR array patterns were fabricated by electron beam lithography and ICP etching of silicon. The basic size unit was 200 nm, 400 nm, and 600 nm. Two different etch processes were used, CF{sub 4}/Ar and HBr, which resulted in undercut and vertical sidewall profiles, respectively. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope using all available objectives. The HBr etched two-dimensional BPR arrays have proven to be a very effective calibration standard making possible direct calibration corrections without the need of additional calculation considerations, while departures from the ideal vertical sidewall require an additional correction term for the CF{sub 4}/Ar etched samples. [8] Initial surface roughness of low cost 'prime' wafers limits low magnification calibration but should not be a limitation if better polished samples are used.

36 MATERIALS SCIENCE↗

Investigation of Coded Source Neutron Imaging at the North Carolina State University PULSTAR Reactor

A neutron imaging facility is located on beam-tube #5of the 1-MWth PULSTAR reactor at the North Carolina StateUniversity. An investigation has been initiated to explore theapplication of coded imaging techniques at the facility. Codedimaging uses a mosaic of pinholes to encode an aperture, thusgenerating an encoded image of the object at the detector. Toreconstruct the image recorded by the detector, correspondingdecoding patterns are used. The optimized design of coded masksis critical for the performance of this technique and will dependon the characteristics of the imaging beam. In this work, MonteCarlo (MCNP) simulations were utilized to explore the neededmodifications to the PULSTAR thermal neutron beam to supportcoded imaging techniques. In addition, an assessment of codedmask design has been performed. The simulations indicated thata 12 inch single crystal sapphire filter is suited for such anapplication at the PULSTAR beam in terms of maximizing fluxwith good neutron-to-gamma ratio. Computational simulationsdemonstrate the feasibility of correlation reconstruction methodson neutron transmission imaging. A gadolinium aperture withthickness of 500 m was used to construct the mask using a 38 ×34 URA pattern. A test experiment using such a URA design hasbeen conducted and the point spread function of the system hasbeen measured.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation on lateral resolution of surface slope profilers

Here, we investigate and compare the spatial (lateral) resolution, or more generally, the optical/instrumental transfer function (OTF/ITF) of surface slope measuring profilometers of two different types that are commonly used for high accuracy characterization of x-ray optics at the long-spatial-wavelength range. These are an autocollimator based profiler, Optical Surface Measuring System (OSMS), and a long trace profiler, LTP-II, both available at the Advanced Light Source (ALS) X-Ray Optics Lab (XROL). In the OSMS, an ELCOMAT-3000 electronic auto-collimator, vertically mounted to the translation carriage and equipped with an aperture of 2.5 mm diameter, is scanned along the surface under test. The LTP-II OTF has been measured for two different configurations, a classical two-beam pencil-beam-interferometry and a single-Gaussian-beam deflectometry. For the ITF calibration, we apply a recently developed method based on test surfaces with one-dimensional (1D) linear chirped height profiles of constant slope amplitude. Analytical expressions for the OTFs, empirically deduced based on the experimental results, are presented. We also discuss the application of the results of the ITF measurements and modeling to improve the surface slope metrology with state-of-the-art x-ray mirrors.

42 ENGINEERING↗

THE BLANCO COSMOLOGY SURVEY: DATA ACQUISITION, PROCESSING, CALIBRATION, QUALITY DIAGNOSTICS, AND DATA RELEASE

The Blanco Cosmology Survey (BCS) is a 60 night imaging survey of {approx}80 deg{sup 2} of the southern sky located in two fields: ({alpha}, {delta}) = (5 hr, -55 Degree-Sign ) and (23 hr, -55 Degree-Sign ). The survey was carried out between 2005 and 2008 in griz bands with the Mosaic2 imager on the Blanco 4 m telescope. The primary aim of the BCS survey is to provide the data required to optically confirm and measure photometric redshifts for Sunyaev-Zel'dovich effect selected galaxy clusters from the South Pole Telescope and the Atacama Cosmology Telescope. We process and calibrate the BCS data, carrying out point-spread function-corrected model-fitting photometry for all detected objects. The median 10{sigma} galaxy (point-source) depths over the survey in griz are approximately 23.3 (23.9), 23.4 (24.0), 23.0 (23.6), and 21.3 (22.1), respectively. The astrometric accuracy relative to the USNO-B survey is {approx}45 mas. We calibrate our absolute photometry using the stellar locus in grizJ bands, and thus our absolute photometric scale derives from the Two Micron All Sky Survey, which has {approx}2% accuracy. The scatter of stars about the stellar locus indicates a systematic floor in the relative stellar photometric scatter in griz that is {approx}1.9%, {approx}2.2%, {approx}2.7%, and {approx}2.7%, respectively. A simple cut in the AstrOmatic star-galaxy classifier spread{sub m}odel produces a star sample with good spatial uniformity. We use the resulting photometric catalogs to calibrate photometric redshifts for the survey and demonstrate scatter {delta}z/(1 + z) = 0.054 with an outlier fraction {eta} < 5% to z {approx} 1. We highlight some selected science results to date and provide a full description of the released data products.

79 ASTRONOMY AND ASTROPHYSICS↗

A discussion of image sharpness

The image sharpness problem is discussed in terms of a scene which is viewed by a sensor. The sensor has some sort of function which is a nonpoint observing function, and it's a function that gathers energy from some region around a point in the scene. That energy is integrated and is contributed to each point or each sample that is taken of the scene. The samples become the pixels, and the pixels are assembled together into the digital image. Each one has some blurr or some of what is called the point's spread function creating the value of information or data that is seen in each pixel. Then the sensor and electronic part of the system acts on that signal out of the sensor and perhaps adds more blurring, more loss of resolution to the system. Finally, sampling and quantization of the data produce their effects. The signal is sampled at some rate and the digital image is created from that. The sampling or digitizing process puts the continuous voltage into a number of discrete binary levels, and another error is introduced there.

Anuta, P.↗

Maximizing the Radar Generalized Image Quality Equation for Bistatic SAR Using Waveform Frequency Agility

The radar generalized image quality equation (RGIQE) is a metric used to measure both monostatic and bistatic synthetic aperture radar (BSAR) image quality, it is a function of signal-to-noise ratio (SNR) and 2-D bandwidth. The 2-D bandwidth is equal to the area of the transfer function’s (TF) passband region. With the exception of side-looking monostatic geometries, almost all monostatic and bistatic geometries have skewed passband shapes when waveform frequency parameters remain unchanged from pulse to pulse. Most synthetic aperture radar (SAR) applications require a rectangular-shaped passband region, this is achieved by inscribing a rectangular region within the skewed intrinsic passband region. Increasing skewness results in less inscription area reducing 2-D bandwidth, image SNR, and thus RGIQE capacity. In this article, a waveform with frequency agility is used to rectify the skewness that degrades RGIQE capacity. By changing the waveform’s center frequency and instantaneous bandwidth from pulse to pulse in a particular manner, the intrinsic passband region can be de-skewed. The de-skewed shape maximizes the inscription area thus maximizing 2-D bandwidth, image SNR, and RGIQE capacity. Here, three examples are given in this article, one monostatic geometry, and two bistatic geometries. RGIQE capacity is increased by 52.02%, 44.42%, and 79.09% for the three examples.

47 OTHER INSTRUMENTATION↗

The impact of positron range on PET resolution, evaluated with phantoms and PHITS Monte Carlo simulations for conventional and non-conventional radionuclides

The increasing interest and availability of non-standard positron-emitting radionuclides has heightened the relevance of radionuclide choice in the development and optimization of new positron emission tomography (PET) imaging procedures, both in preclinical research and clinical practice. Differences in achievable resolution arising from positron range can largely influence application suitability of each radionuclide, especially in small-ring preclinical PET where system blurring factors due to annihilation photon acollinearity and detector geometry are less significant. Here, some resolution degradation can be mitigated with appropriate range corrections implemented during image reconstruction, the quality of which is contingent on an accurate characterization of positron range.

43 PARTICLE ACCELERATORS↗

M DWARFS IN SLOAN DIGITAL SKY SURVEY STRIPE 82: PHOTOMETRIC LIGHT CURVES AND FLARE RATE ANALYSIS

We present a flare rate analysis of 50,130 M dwarf light curves in Sloan Digital Sky Survey Stripe 82. We identified 271 flares using a customized variability index to search {approx}2.5 million photometric observations for flux increases in the u and g bands. Every image of a flaring observation was examined by eye and with a point-spread function-matching and image subtraction tool to guard against false positives. Flaring is found to be strongly correlated with the appearance of H{alpha} in emission in the quiet spectrum. Of the 99 flare stars that have spectra, we classify eight as relatively inactive. The flaring fraction is found to increase strongly in stars with redder colors during quiescence, which can be attributed to the increasing flare visibility and increasing active fraction for redder stars. The flaring fraction is strongly correlated with |Z| distance such that most stars that flare are within 300 pc of the Galactic plane. We derive flare u-band luminosities and find that the most luminous flares occur on the earlier-type m dwarfs. Our best estimate of the lower limit on the flaring rate (averaged over Stripe 82) for flares with {delta}u {>=} 0.7 mag on stars with u < 22 is 1.3 flares hr{sup -1} deg{sup -2} but can vary significantly with the line of sight.

79 ASTRONOMY AND ASTROPHYSICS↗

Revealing asymmetries in the HD 181327 debris disk: A recent massive collision or interstellar medium warping

New multi-roll coronagraphic images of the HD 181327 debris disk obtained using the Space Telescope Imaging Spectrograph on board the Hubble Space Telescope reveal the debris ring in its entirety at high signal-to-noise ratio and unprecedented spatial resolution. We present and apply a new multi-roll image processing routine to identify and further remove quasi-static point-spread function-subtraction residuals and quantify systematic uncertainties. We also use a new iterative image deprojection technique to constrain the true disk geometry and aggressively remove any surface brightness asymmetries that can be explained without invoking dust density enhancements/deficits. The measured empirical scattering phase function for the disk is more forward scattering than previously thought and is not well-fit by a Henyey-Greenstein function. The empirical scattering phase function varies with stellocentric distance, consistent with the expected radiation pressured-induced size segregation exterior to the belt. Within the belt, the empirical scattering phase function contradicts unperturbed debris ring models, suggesting the presence of an unseen planet. The radial profile of the flux density is degenerate with a radially varying scattering phase function; therefore estimates of the ring's true width and edge slope may be highly uncertain. We detect large scale asymmetries in the disk, consistent with either the recent catastrophic disruption of a body with mass >1% the mass of Pluto, or disk warping due to strong interactions with the interstellar medium.

79 ASTRONOMY AND ASTROPHYSICS↗

Variational Dirichlet Blur Kernel Estimation

Blind image deconvolution involves two key objectives: 1) latent image and 2) blur estimation. For latent image estimation, we propose a fast deconvolution algorithm, which uses an image prior of nondimensional Gaussianity measure to enforce sparsity and an undetermined boundary condition methodology to reduce boundary artifacts. For blur estimation, a linear inverse problem with normalization and nonnegative constraints must be solved. However, the normalization constraint is ignored in many blind image deblurring methods, mainly because it makes the problem less tractable. In this paper, we show that the normalization constraint can be very naturally incorporated into the estimation process by using a Dirichlet distribution to approximate the posterior distribution of the blur. Making use of variational Dirichlet approximation, we provide a blur posterior approximation that considers the uncertainty of the estimate and removes noise in the estimated kernel. Furthermore, experiments with synthetic and real data demonstrate that the proposed method is very competitive to the state-of-the-art blind image restoration methods.

97 MATHEMATICS AND COMPUTING↗

Complex-valued universal linear transformations and image encryption using spatially incoherent diffractive networks

As an optical processor, a diffractive deep neural network (D2NN) utilizes engineered diffractive surfaces designed through machine learning to perform all-optical information processing, completing its tasks at the speed of light propagation through thin optical layers. With sufficient degrees of freedom, D2NNs can perform arbitrary complex-valued linear transformations using spatially coherent light. Similarly, D2NNs can also perform arbitrary linear intensity transformations with spatially incoherent illumination; however, under spatially incoherent light, these transformations are nonnegative, acting on diffraction-limited optical intensity patterns at the input field of view. Here, we expand the use of spatially incoherent D2NNs to complex-valued information processing for executing arbitrary complex-valued linear transformations using spatially incoherent light. Through simulations, we show that as the number of optimized diffractive features increases beyond a threshold dictated by the multiplication of the input and output space-bandwidth products, a spatially incoherent diffractive visual processor can approximate any complex-valued linear transformation and be used for all-optical image encryption using incoherent illumination. The findings are important for the all-optical processing of information under natural light using various forms of diffractive surface-based optical processors.

36 MATERIALS SCIENCE↗