Advances in Westinghouse fuel rod design technology (PAD5)
The Westinghouse Performance Analysis and Design (PAD) code for light-water reactors has been recently updated to version PAD5 and submitted to NRC for review. PAD5 incorporates extensive updates in fuel performance and material property models, including fuel thermal conductivity, pellet fragment relocation, fission gas release, fission gas swelling, and cladding creep and growth. Advances in thermal models are mainly in pellet fragment relocation, radial power distribution within the pellet, and the changes in fuel thermal conductivity due to changes in temperature, burnup and fuel porosity. The PAD5 thermal fission gas release model is a phenomenological model based on the irradiation dependence of the gas release from mechanistic processes for the diffusion of the fission gas generated in the fuel grains to the grain boundaries, formation of fission gas bubbles on the grain boundaries and release of the fission gas when these grain boundary bubbles inter-link. The PAD5 cladding creep model is predominantly a combination of the following mechanisms: thermal creep, irradiation induced creep, and irradiation enhanced creep. The fuel performance database used for the development, calibration and testing of the PAD5 code covers a broad range of both commercial irradiation data and test rod data and requires continuously additional data focusing on the latest development of the PAD5 code. Test programs are also included in the database. These data are checked and stored in a hierarchical database structure that supports the automation of model development and calibration. New data, once incorporated into the database, can be quickly evaluated with respect to key fuel and cladding performance models to confirm expected trends or to evaluate potential model improvements. This automated calibration system has been integrated with state-of-the-art optimization packages in DAKOTA Analysis Kit to provide for advanced statistical assessments and model coefficient optimization. Calibration results are automatically tabulated and plotted to provide easy assessment of trends or new behaviors.