Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microfluidics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Novel in-capsule synthesis of metal–organic framework for innovative carbon dioxide capture system

Metal-Organic Frameworks (MOFs) have been developed as solid sorbents for CO2 capture applications and their properties can be controlled by tuning the chemical blocks of their crystalline units. A number of MOFs (e.g., HKUST-1) have been developed but the question remains how to deploy them for gas–solid contact. Unfortunately, the direct use of MOFs as nanocrystals would lead to serious problems and risks. Here, for the first time, we report a novel MOF-based hybrid sorbent that is produced via an innovative in-situ microencapsulated synthesis. Using a custom-made double capillary microfluidic assembly, double emulsions of the MOF precursor solutions and UV-curable silicone shell fluid are produced. Subsequently, HKUST-1 MOF is successfully synthesized within the droplets enclosed in the gas permeable microcapsules. The developed MOF-bearing microcapsules uniquely allow the deployment of functional nanocrystals without the challenge of handling ultrafine particles, and further, can selectively reject undesired compounds to protect encapsulated MOFs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An engineered lactate oxidase based electrochemical sensor for continuous detection of biomarker lactic acid in human sweat and serum

Lactate levels in humans reveal intensity and duration of exertion and provide a critical readout for the severity of life-threatening illnesses such as pediatric sepsis. Using the lactate oxidase enzyme (Lox) from Aerococcus viridians, we demonstrated its functionality for lactate electrochemical sensing in physiological fluids in a lab setting. The structure and dynamics of LOx were validated by crystallography, X-ray scattering, and hydroxyl radical protein footprinting. This provided a validated protein template for understanding and designing an enzyme-based electrochemical sensing elements. Using this template, LOx enzyme variants were generated and compared. Comparison of the variants demonstrates that one exhibits effective lactate sensing at significantly reduced operating voltages. Additionally, we demonstrate that the four hexahistidine-tags on each enzyme tetramer are sufficient for immobilization to create a durable, functional sensor, with no need for a covalent attachment, enabling self-immobilization and eliminating the need for additional immobilization steps. The functionality of the LOx enzyme variants was verified at physiological lactate concentrations in both human serum (0–4 mM) and artificial sweat (0–100 mM) using 3-electrode setups for analysis of the three variants in parallel. Accuracy of measurement in both artificial sweat and human serum were high. Employing a microfluidic flow cell, we successfully monitored varying lactate levels in physiological fluids continuously over a 2h period. Overall, this optimized LOx enzyme, which self-immobilizes onto gold sensing electrodes, facilitates efficient and reliable lactate detection and continuous monitoring at reduced operating voltages suitable for further development towards commercial use.

60 APPLIED LIFE SCIENCES↗

A microreactor array for spatially resolved measurement of catalytic activity for high-throughput catalysis science

We describe a 100 channel microreactor array capable of spatially resolved measurement of catalytic activity across the surface of a flat substrate. When used in conjunction with a composition spread alloy film (CSAF, e.g. Pd{sub x}Cu{sub y}Au{sub 1-x-y}) across which component concentrations vary smoothly, such measurements permit high-throughput analysis of catalytic activity and selectivity as a function of catalyst composition. In the reported implementation, the system achieves spatial resolution of 1 mm{sup 2} over a 10×10 mm{sup 2} area. During operation, the reactant gases are delivered at constant flow rate to 100 points of differing composition on the CSAF surface by means of a 100-channel microfluidic device. After coming into contact with the CSAF catalyst surface, the product gas mixture from each of the 100 points is withdrawn separately through a set of 100 isolated channels for analysis using a mass spectrometer. We demonstrate the operation of the device on a Pd{sub x}Cu{sub y}Au{sub 1-x-y} CSAF catalyzing the H{sub 2}-D{sub 2} exchange reaction at 333 K. In essentially a single experiment, we measured the catalytic activity over a broad swathe of concentrations from the ternary composition space of the Pd{sub x}Cu{sub y}Au{sub 1-x-y} alloy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ionic complexation of endblock-sulfonated thermoplastic elastomers and their physical gels for improved thermomechanical performance

Thermoplastic elastomers (TPEs) composed of nonpolar triblock copolymers constitute a broadly important class of (re)processable network-forming macromolecules employed in ubiquitous commercial applications. Physical gelation of these materials in the presence of a low-volatility oil that is midblock-selective yields tunably soft TPE gels (TPEGs) that are suitable for emergent technologies ranging from electroactive, phase-change and shape-memory responsive media to patternable soft substrates for flexible electronics and microfluidics. Many of the high-volume TPEs used for these purposes possess styrenic endblocks that are inherently limited by a relatively low glass transition temperature. To mitigate this shortcoming, we sulfonate and subsequently complex (and physically crosslink) the endblocks with trivalent Al3+ ions. Doing so reduces the effective hydrophilicity of the sulfonated endblocks, as evidenced by water uptake measurements, while concurrently enhancing the thermomechanical stability of the corresponding TPEGs. Chemical modification results, as well as morphological and property development, are investigated as functions of the degree of sulfonation, complexation and TPEG composition. (C) 2020 Published by Elsevier Inc.

36 MATERIALS SCIENCE↗

Breakdown of electroneutrality in nanopores

Ion transport in extremely narrow nanochannels has gained increasing interest in recent years due to unique physical properties at the nanoscale and the technological advances that allow us to study them. It is tempting to approach this confined regime with the theoretical tools and knowledge developed for membranes and microfluidic devices, and naively apply continuum models, such as the Poisson-Nernst-Planck and Navier-Stokes equations. However, it turns out that some of the most basic principles we take for granted in larger systems, such as the complete screening of surface charge by counter-ions, can break down under extreme confinement. Additionally, we show that in a truly one-dimensional system of ions interacting with three-dimensional electrostatic interactions, the screening length is exponentially large, and can easily exceed the macroscopic length of a nanotube. Without screening, electroneutrality breaks down within the nanotube, with fundamental consequences for ion transport and electrokinetic phenomena. In this work, we build a general theoretical framework for electroneutrality breakdown in nanopores, focusing on the most interesting case of a one-dimensional nanotube, and show how it provides an elegant interpretation for the peculiar scaling observed in experimental measurements of ionic conductance in carbon nanotubes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimum concentration of fly ash nanoparticles to stabilize CO 2 foams for aquifer and soil remediation

Contamination caused by non-aqueous phase liquids (NAPLs) in aquifers and soil is an important challenge that requires effective remediation techniques. One potential approach is through the use of CO 2 foams to displace NAPLs from permeable media. CO 2 foams generated only by surfactants are not stable enough for the efficient removal of NAPLs contamination. This shortcoming may be alleviated via the use of nanoparticles (NPs)-surfactant mixtures as a stabilizing agent. This work focuses on the evaluation of the optimum concentration of fly ash nanoparticles for stabilizing CO 2 foam with the combined action of the surfactant. The performance of this foam is evaluated in remediating a contaminated 41 mm × 36 mm surrogate permeable medium in a microfluidic device. Mixtures of fly ash, a by-product of coal-burning power plants, and alpha-olefin sulfonate (AOS) and lauramidopropyl betaine (LAPB) surfactants are used to generate stable foams. The results show that a 1000 mg/L AOS-LAPB surfactant solution along with 1000 mg/L of fly ash NPs produces the best performance. Formation of deposits in the matrix is observed. These deposits, which are more prominent at higher NP concentrations, appear to adversely affect displacement, displacement efficiency and remediation of the medium. This study demonstrates that using fly ash nanoparticles and optimizing their concentration can effectively stabilize CO 2 foams and improve the displacement efficiency for aquifer and soil remediation.

54 ENVIRONMENTAL SCIENCES↗

Sharp front tracking with geometric interface reconstruction

Here, this paper presents a novel sharp front-tracking method designed to address limitations in classical front-tracking approaches, specifically their reliance on smooth interpolation kernels and extended stencils for coupling the front and fluid mesh. In contrast, the proposed method employs exclusively sharp, localized interpolation and spreading kernels, restricting the coupling to the interfacial fluid cells–those containing the interface/front. This localized coupling is achieved by integrating a divergence-preserving velocity interpolation method with a piecewise parabolic interface calculation (PPIC) and a polyhedron intersection algorithm to compute the indicator function and local interface curvature. Surface tension is computed using the Continuum Surface Force (CSF) method, maintaining consistency with the sharp representation. Additionally, we propose an efficient local roughness smoothing implementation to account for surface mesh undulations, which is easily applicable to any triangulated surface mesh. Building on our previous work, the primary innovation of this study lies in the localization of the coupling for both the indicator function and surface tension calculations. By reducing the interface thickness on the fluid mesh to a single cell, as opposed to the 4–5 cell spans typical in classical methods, the proposed sharp front-tracking method achieves a highly localized and accurate representation of the interface. This sharper representation mitigates parasitic currents and improves force balancing, making it particularly suitable for scenarios where the interface plays a critical role, such as microfluidics, fluid-fluid interactions, and fluid-structure interactions. The proposed method is comprehensively validated and tested on canonical interfacial flow problems, including stationary and translating Laplace equilibria, oscillating droplets, and rising bubbles. The presented results demonstrate that the sharp front-tracking method significantly outperforms the classical approach in terms of accuracy, stability, and computational efficiency. Notably, parasitic currents are reduced by approximately two orders of magnitude and stable results are obtained for parameter ranges where classical front tracking fails to converge.

42 ENGINEERING↗

Fabrication of Ag-Fe{sub 3}O{sub 4}/Fe superhydrophobic surface on galvanic sheet for its application

Highlights: • Ag-Fe{sub 3}O{sub 4}/Fe superhydrophobic surface (SHS) was fabricated on galvanic sheet. • The SHS has water contact angle of 165° and sliding angle of 2°. • The SHS has excellent properties of anti-icing, self-cleaning and catalysis. • This is an easy and cheap method to fabricate SHS on the galvanic sheet. - Abstract: Durable Ag-Fe{sub 3}O{sub 4}/Fe superhydrophobic surface (SHS) with dendritic structures on the galvanic sheet was obtained by chemical etching, deposition and following annealing process. The promising SHS showed fine superhydrophobicity having the water contact angle of 165° and dynamic sliding angle of 2°. Experimental results showed that the obtained SHS sample has excellent properties of anti-corrosion, catalysis, anti-icing, rolling-off and self-cleaning. The conditions of etching, chemical immersion, and annealing to obtain SHS were investigated. Chemical stability and durability of SHS were investigated via storage in air for ten months. The SHS as a catalyst showed long-term stability, catalytic activity, and reusability, as compared to the substrate of the un-annealed surface. It is an effortless and cheap method to fabricate SHS on the galvanic sheet for industrial applications. The SHS has a potential utilization in a diverse range of bio-medicines, chemistry, microfluidics fields, and electronics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Research of sensing characteristic and dynamic measurement of graphene oxides modified flexible arrayed RuO2 chlorine ion sensor

Highlights: • Sensitivity of the flexible arrayed RuO2/GO chlorine ion sensor was improved with optimal GO concentration, which could increase the reaction area between the chlorine ion and chlorine sensing membrane. • The electrochemical impedance spectroscopy (EIS) and atomic force microscope (AFM) were utilized to explain the relationships among the electron transfer resistance, GO modified amount and sensitivity. • The 30 μL/min flow rate of dynamic measurement for flexible arrayed RuO2/0.010 wt% GO chlorine ion sensor was obtained the best sensitivity and linearity 66.673 mV/pCl and 0.998, respectively. - Abstract: In this study, we used the graphene oxide (GO) solution, in which the concentration was from 0.005 wt% to 0.500 wt%, to modify the flexible arrayed ruthenium dioxide (RuO{sub 2}) chlorine ion sensor. It is found that the flexible arrayed RuO{sub 2}/0.010 wt% GO chlorine ion sensor had the best sensitivity (44.445 mV/pCl) and the linearity was 0.971. The electrochemical impedance spectroscopy (EIS) and atomic force microscope (AFM) were utilized to explain the relationships among the electron transfer resistance, GO modified amount and sensitivity. After that, we used the flexible arrayed RuO{sub 2}/0.010 wt% GO chlorine ion sensor and the microfluidic measurement system to investigate the dynamic sensing characteristics with different flow rates from 5 μL/min to 40 μL/min. According to the experimental results, the best sensitivity and linearity of flexible arrayed RuO{sub 2}/0.010 wt% GO chlorine ion sensor were 66.673 mV/pCl and 0.992 at 30 μL/min.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Proteomic Profiling of Intra-Islet Features Reveals Substructure-Specific Protein Signatures

Despite their diminutive size, islets of Langerhans play a large role in maintaining systemic energy balance in the body. New technologies have enabled us to go from studying the whole pancreas, to isolated whole islets, to partial islet sections, and now to islet substructures isolated from within the islet. Using a microfluidic nanodroplet-based proteomics platform coupled with laser capture microdissection (LCM), we present an in-depth investigation of protein profiles specific to regions within the islet. These regions studied include the vascular tissue containing interface boundary, micro-vascular tissue internal to the islet, isolated endocrine cells, islet sections with vasculature intact, and finally acinar tissue from around the islet. Unique protein signatures observed in the inner vasculature potentially indicate increased innervation and intra-islet neuron-like crosstalk compared to external vasculature. We also demonstrate the utility of these data for isolating localized structure-specific drug-target interactions using existing protein/drug binding databases.

59 BASIC BIOLOGICAL SCIENCES↗

Journal Pre-proof3D printed polylactic acid and acrylonitrile butadiene styrene fluidicstructures for biological applications: tailoring bio-material interfaceviasurface modification

Three-dimensional (3D) printing is a rapidly growing technology that best fits for cell culture and other biological applications due to its potential to build immensely complex structures from customized designs. However, use of 3D printed structures for cell adhesion, proliferation, and activation requires tailoring of surface characteristics. In this context, this work investigates the use of two biocompatible 3D printable polymer materials, Poly-L-lactic Acid (PLA) and Acrylonitrile Butadiene Styrene (ABS) for bio applications, and the effect of their post-printing surface modification processes to achieve desired bio functionality. Three post-printing surface modification techniques, alkaline hydrolysis, ultraviolet ozone plasma irradiation and gold thin film deposition are performed with the objective of introducing useful levels of surface functionalities. Poly-L-lysine (PLL) labelled with FITC chromophore is immobilized on the surface modified samples following standard protocols. The effect of surface roughness and porosity of the 3D printed structures on the polypeptide immobilization is compared on as-printed versus mechanically polished surfaces. Different characterization methods, viz., Fluorescence microscopy, Raman Spectroscopy and UV–vis spectroscopy, are used to study the efficacy of the surface modification and PLL immobilization techniques. Our results demonstrated denser PLL attachment on polished hydrolyzed PLA and ABS surfaces which enables the use of these printable polymers for a range of applications such as tissue scaffolds and microfluidics.

3D Printing, PLA, ABS, Biodegradable Polymer, Surf↗

Advances and challenges in CO2 foam technologies for enhanced oil recovery in carbonate reservoirs

Utilization of surfactants for generating foam has the potential for fluid-mobility control during CO2 flooding processes, leading to improved oil recovery. This manuscript is a review of the most important aspects for the design of CO2-foams with mobility control in carbonate reservoirs, including recent advances in novel surfactants and analytical techniques for analysis of surfactant adsorption on carbonate minerals and their thermal stability. Several key parameters and properties regarding foam transport in porous media are reviewed such as, the minimum pressure gradient required for foam generation, the effects of the partition coefficient of a CO2-soluble surfactant on foam transport in rock cores, visualization of foam flow by either microfluidic or PET/CT imaging processes in heterogeneous or fractured systems and the effect of oil on foam transport under reservoir conditions. Also are discussed the most recent advances of two major foam modeling methods, including the semi-empirical STARS foam model and the population balance model, as well as CO2 foam pilot tests and the factors governing their successes.

Jian, Guoqing↗

MicroRaman measurements for nuclear fuel reprocessing applications

Treatment and reuse of used nuclear fuel is a key component in closing the nuclear fuel cycle. Solvent extraction reprocessing methods that have been developed contain various steps tailored to the separation of specific radionuclides, which are highly dependent upon solution properties. The instrumentation used to monitor these processes must be robust, require little or no maintenance, and be able to withstand harsh environments such as high radiation fields and aggressive chemical matrices. Our group has been investigating the use of optical spectroscopy for the on-line monitoring of actinides, lanthanides, and acid strength within fuel reprocessing streams. This paper will focus on the development and application of a new MicroRaman probe for on-line real-time monitoring of the U(VI)/nitrate ion/nitric acid in solutions relevant to used nuclear fuel reprocessing. Previous research has successfully demonstrated the applicability on the macroscopic scale, using sample probes requiring larger solution volumes. In an effort to minimize waste and reduce dose to personnel, we have modified this technique to allow measurement at the microfluidic scale using a Raman microprobe. Under the current sampling environment, Raman samples typically require upwards of 10 mL and larger. Using the new sampling system, we can sample volumes at 10 μL or less, which is a scale reduction of over 1,000 fold in sample size. Finally, this paper will summarize our current work in this area including: comparisons between the macroscopic and microscopic probes for detection limits, optimized channel focusing, and application in a flow cell with varying levels of HNO 3 , and UO 2 (NO 3 ) 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A novel polyimide based micro heater with high temperature uniformity

MEMS based micro heaters are a key component in micro bio-calorimetry, nondispersive infrared gas sensors, semiconductor gas sensors and microfluidic actuators. A micro heater with a uniform temperature distribution in the heating area and short response time is desirable in ultrasensitive temperature-dependent measurements. In this study, we propose a novel micro heater design to reach a uniform temperature in a large heating area by optimizing the heating power density distribution in the heating area. A polyimide membrane is utilized as the substrate to reduce the thermal mass and heat loss which allows for fast thermal response as well as a simplified fabrication process. A gold and titanium heating element is fabricated on the flexible polyimide substrate using the standard MEMS technique. The temperature distribution in the heating area for a certain power input is measured by an IR camera, and is consistent with FEA simulation results. Finally, this design can achieve fast response and uniform temperature distribution, which is quite suitable for the programmable heating such as impulse and step driving.

42 ENGINEERING↗

An air-spaced terahertz metamaterial perfect absorber

Metamaterial absorbers are typically comprised of a layer of split-ring resonators and a ground plane with a dielectric spacer layer that provides structural support and in which absorbed energy is deposited. For this work, we address the question “What happens to the absorption if the spacer layer is removed?” through the design, fabrication, and characterization of a terahertz metamaterial absorber with air as the spacer layer. Reflection based terahertz time-domain spectroscopy was employed to measure the absorption and interference theory was used to interpret the results. The surface current in the gold ground plane and split-ring resonator layer is solely responsible for the absorption in the form of joule heating. In comparison to dielectric spacer layer absorbers, the quality factor is increased by a factor of ~3. The electric field is highly concentrated in the volume between split-ring resonator layer and the ground plane offering the potential for novel sensing application if materials can be incorporated into this region (e.g. with microfluidics). In the spirit of this possibility, simulations of the absorption have been performed. The variation of the real part of the permittivity of the spacer material results in an absorption peak frequency shift, while a change in the imaginary part affects the quality factor and amplitude. Ultimately, the high quality factor and the absence of the spacer material provide the air-spacer metamaterial absorber with unique advantages for sensing applications.

42 ENGINEERING↗

Contributions of biofilm-induced flow heterogeneities to solute retention and anomalous transport features in porous media

We report that microbial biofilms are ubiquitous within porous media and the dynamics of their growth influence surface and subsurface flow patterns which impacts the physical properties of porous media and large-scale transport of solutes. Here, a two-dimensional pore-scale numerical model was used to evaluate the impact of biofilm-induced flow heterogeneities on conservative transport. Our study integrates experimental biofilm images of Paenibacillus 300A strain in a microfluidic device packed with cylindrical grains in a hexagonal distribution, with mathematical modeling. Biofilm is represented as a synthetic porous structure with locally varying physical properties that honors the impact of biofilm on the porous medium. We find that biofilm plays a major role in shaping the observed conservative transport dynamics by enhancing anomalous characteristics. More specifically, when biofilm is present, the pore structure in our geometry becomes more spatially correlated. We observe intermittent behavior in the Lagrangian velocities that switches between fast transport periods and long trapping events. Our results suggest that intermittency enhances solute spreading in breakthrough curves which exhibit extreme anomalous slope at intermediate times and very marked late solute arrival due to solute retention. The efficiency of solute retention by the biofilm is controlled by a transport regime which can extend the tailing in the concentration breakthrough curves. These results indicate that solute retention by the biofilm exerts a strong control on conservative solute transport at pore-scale, a role that to date has not received enough attention.

54 ENVIRONMENTAL SCIENCES↗

Lab-on-a-chip platforms for quantification of multicellular interactions in bone remodeling

Highlights: • Microchips are developed for stimulating bone cells and quantifying activity. • A chip permits osteocyte loading and soluble signal analysis. • A chip enables quantification of bone resorption and formation. • This model may remove spatial and temporal limitations of existing systems. • This microfluidic approach shows promise for future discovery in the bone field. Researchers have been using lab-on-a-chip systems to isolate factors for study, simulate laboratory analysis and model cellular, tissue and organ level processes. The technology is increasing rapidly, but the bone field has been slow to keep pace. Novel models are needed that have the power and flexibility to investigate the elegant and synchronous multicellular interactions that occur in normal bone turnover and in disease states in which remodeling is implicated. By removing temporal and spatial limitations and enabling quantification of functional outcomes, the platforms should provide unique environments that are more biomimetic than single cell type systems while minimizing complex systemic effects of in vivo models. This manuscript details the development and characterization of lab-on-a-chip platforms for stimulating osteocytes and quantifying bone remodeling. Our platforms provide the foundation for a model that can be used to investigate remodeling interactions as a whole or as a standard mechanotransduction tool by which isolated activity can be quantified as a function of load.

60 APPLIED LIFE SCIENCES↗