Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “micro”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Scalable method for micro-CT analysis enables large scale quantitative characterization of brain lesions and implants

Anatomic evaluation is an important aspect of many studies in neuroscience; however, it often lacks information about the three-dimensional structure of the brain. Micro-CT imaging provides an excellent, nondestructive, method for the evaluation of brain structure, but current applications to neurophysiological or lesion studies require removal of the skull as well as hazardous chemicals, dehydration, or embedding, limiting their scalability and utility. Here we present a protocol using eosin in combination with bone decalcification to enhance contrast in the tissue and then employ monochromatic and propagation phase-contrast micro-CT imaging to enable the imaging of brain structure with the preservation of the surrounding skull. Instead of relying on descriptive, time-consuming, or subjective methods, we develop simple quantitative analyses to map the locations of recording electrodes and to characterize the presence and extent of hippocampal brain lesions.

3-D reconstruction↗

Pore-scale observations of natural hydrate-bearing sediments via pressure core sub-coring and micro-CT scanning

Abstract Both intra-pore hydrate morphology and inter-pore hydrate distribution influence the physical properties of hydrate-bearing sediments, yet there has been no pore-scale observations of hydrate habit under pressure in preserved pressure core samples so far. We present for the first time a pore-scale micro-CT study of natural hydrate-bearing cores that were acquired from Green Canyon Block 955 in UT-GOM2-1 Expedition and preserved within hydrate pressure–temperature stability conditions throughout sub-sampling and imaging processes. Measured hydrate saturation in the sub-samples, taken from units expected to have in-situ saturation of 80% or more, ranges from 3 ± 1% to 56 ± 11% as interpreted from micro-CT images. Pore-scale observations of gas hydrate in the sub-samples suggest that hydrate in silty sediments at the Gulf of Mexico is pore-invasive rather than particle displacive, and hydrate particles in these natural water-saturated samples are pore-filling with no evidence of grain-coating. Hydrate can form a connected 3D network and provide mechanical support for the sediments even without cementation. The technical breakthrough to directly visualize particle-level hydrate pore habits in natural sediments reported here sheds light on future investigations of pressure- and temperature-sensitive processes including hydrate-bearing sediments, dissolved gases, and other biochemical processes in the deep-sea environment.

58 GEOSCIENCES↗

Micro-Raman imaging of isomeric segregation in small-molecule organic semiconductors

Abstract Charge transport in organic semiconductors is highly sensitive to film heterogeneity and intermolecular interactions, but probing these properties on the length scales of disorder is often difficult. Here we use micro-Raman spectroscopy to assign vibrational modes of isomerically pure syn and anti 2,8-difluoro-5,11-bis(triethylsilylethynyl)anthradithiophene (diF-TES ADT) by comparing to density functional theory calculations. With polarization-dependent measurements, we determine the orientation of crystallites in pure isomers. In mixed-isomer samples, we observe narrow linewidths and superposition spectra, indicating coexistence of isomerically pure sub-domains on length scales smaller than the probe area. Using the ring breathing modes close to 1300 cm −1 as indicators of the pure isomer crystalline sub-domains, we image their spatial distribution with 200-nm resolution. These results demonstrate the power of micro-Raman spectroscopy for investigating spatial heterogeneities and clarifying the origin of the reduced charge carrier mobility displayed in mixed-isomer diF-TES ADT.

Huang, Chiung-Wei (ORCID:0000000307361362)↗

Encapsulating micro-nano Si/SiO x into conjugated nitrogen-doped carbon as binder-free monolithic anodes for advanced lithium ion batteries

Silicon monoxide, a promising silicon-based anode candidate for lithium-ion batteries, has recently attracted much attention for its high theoretical capacity, good cycle stability, low cost, and environmental benignity. Currently, the most critical challenge is to improve its low initial coulombic efficiency and significant volume changes during the charge–discharge processes. Herein, we report a binder-free monolithic electrode structure based on directly encapsulating micro-nano Si/SiOx particles into conjugated nitrogen-doped carbon frameworks to form monolithic, multi-core, cross-linking composite matrices. We utilize micro-nano Si/SiOx reduced by high-energy ball-milling SiO as active materials, and conjugated nitrogen-doped carbon formed by the pyrolysis of polyacrylonitrile both as binders and conductive agents. Owing to the high electrochemical activity of Si/SiOx and the good mechanical resiliency of conjugated nitrogen-doped carbon backbones, this specific composite structure enhances the utilization efficiency of SiO and accommodates its large volume expansion, as well as its good ionic and electronic conductivity. The annealed Si/SiOx/polyacrylonitrile composite electrode exhibits excellent electrochemical properties, including a high initial reversible capacity (2734 mA h g-1 with 75% coulombic efficiency), stable cycle performance (988 mA h g-1 after 100 cycles), and good rate capability (800 mA h g-1 at 1 A g-1 rate). Because the composite is naturally abundant and shows such excellent electrochemical performance, it is a promising anode candidate material for lithium-ion batteries. The binder-free monolithic architectural design also provides an effective way to prepare other monolithic electrode materials for advanced lithium-ion batteries.

25 ENERGY STORAGE↗

Development and testing of a novel micro-Raman probe and application of calibration transfer method for the quantitative analysis of microfluidic nitric acid streams

To simplify and improve the safety of reprocessing used nuclear fuel, an initial assessment was made of Raman microscopy applied to microfluidic volumes with a view toward the on-line spectroscopic measurement of highly radioactive solutions. This study compares a microscopic Raman probe (excitation focal point diameter 70 µm) to a larger, well studied probe (excitation focal point diameter 125 µm) used in prior investigations. This was done by chemometrically modeling and predicting concentrations of HNO3 solutions (0 M to 8 M) as they flowed through microfluidic cells based upon spectra from each probe. Spectra recorded for each probe using the same static HNO3 solution set contained in 2 dram glass vials were used as training sets to produce models for the respective probes. Modeling required baseline, normalization and smoothing preprocessing to compensate for a reduced path length between the static glass vial training set (4 cm) and the reduced path length flow cell (1 cm), wide ranging solution concentrations, and the associated non-linear spectral changes, and abrupt and uneven concentration changes of flowing solutions. The micro-Raman probe is able to produce spectra that may be analyzed chemometrically to accurately predict the concentration of flowing HNO3 solutions down to microliter volumes. Based upon RMSECV and RMSEP modeling statistics concentration predictions of the micro-Raman probe are comparable to those obtained for a macro-Raman on identical samples.

microscopic Raman probe, MicroRaman, nitric acid, ↗

Magnetic characterization of a single superparamagnetic bead by phase-sensitive micro-Hall magnetometry.

Employing phase sensitive micro-Hall magnetometry at room temperature, we map the susceptibility of a single superparamagnetic bead, 1.2 {micro}m in diameter, as a function of magnetic field. We find that the dependence can be explained by modeling the bead as an ensemble of noninteracting superparamagnetic nanoparticles with log-normal distribution of magnetic moments. We also discuss the effect of possible dipolar interactions between the nanoparticles on the obtained results.

36 MATERIALS SCIENCE↗

Micro-Crater Laser Induced Breakdown Spectroscopy--an Analytical approach in metals samples

The laser ablation has been increasing its popularity like as technique of chemical analysis. This is due to its great potentiality in the analysis of solid samples. On the way to contributing to the development of the technique, we in this work studied the laser induced breakdown spectroscopy (LIBS) in conditions of micro ablation for future studies of coverings and micro crates analysis. Craters between 2 and 7 micrometers of diameter were made using an Nd-YAG nanosecond laser in their fundamental emission of 1064 nm. In order to create these craters we use an objective lens of long distance work and 0.45 of numerical aperture. The atomic emission versus the energy of the laser and its effect on the size of craters was study. We found that below 3 micrometers although there was evidence of material removal by the formation of a crater, it was no detectable atomic emission for our instruments. In order to try to understand this, curves of size of crater versus plasma temperature using the Boltzmann distribution graphs taking the Copper emission lines in the visible region were made. In addition calibration curves for Copper and aluminum were made in two different matrices; one of it was a Cu/Zn alloy and the other a Zinc Matrix. The atomic lines Cu I (521.78 nm) and Al I (396.15 nm) was used. From the Calibration curve the analytical limit of detection and other analytical parameters were obtained.

36 MATERIALS SCIENCE↗

FTIR, Micro-Raman and Ellipsometry Studies on Silicon Oxynitride Layers Synthesized by Low Energy Ion Implantation

Single crystal silicon were implanted at room temperature with {sup 16}O{sub 2}{sup +} and {sup 14}N{sub 2}{sup +} 30 keV ions in 1:1 ratio with fluences of 2.5x10{sup 17}, 5x10{sup 17}, 7.5x10{sup 17} and 1x10{sup 18} ions-cm{sup -2} to form silicon oxynitride layers. Rapid thermal annealing (RTA) of these samples was carried out at temperature of 623, 873 and 1173 K in nitrogen ambient for 5 min. Fourier transform infrared (FTIR), Micro-Raman and ellipsometry measurements were performed on RTA samples to investigate the structure and phase. The FTIR studies show that the structures of ion-beam synthesized oxynitride layers are strongly dependent on total ion-fluence and annealing temperature. The Micro-Raman studies on annealing revealed formation of partially amorphous oxygen and nitrogen rich silicon oxynitride structures for lower and higher ion fluences respectively with crystalline silicon beneath it. From the ellipsometry studies, the refractive index of the ion beam synthesized layers were found to be in 1.54-1.96 range.

36 MATERIALS SCIENCE↗

Micro Dynamics of Pulsed Laser Induced Bubbles in Dusty Plasma Liquids

We experimentally study the micro dynamics of the laser induced plasma bubble in a dusty plasma liquid formed by negatively charged dust particles suspended in a low pressure rf Ar glow discharge. The plume from the ablation of the suspended dust particles pushes away dust particle and generates a dust-free plasma bubble. It then travels downward. The spatio-temporal evolution of the dust density fluctuation surrounding the bubble is monitored by directly tracking dust motion through optical video microscopy. The micro dynamics of the bubble associated dust acoustic type solitary oscillation in the wake field is investigated and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental and Computational Investigation of a RF Plasma Micro-Thruster

A prototype RF plasma micro-thruster has been investigated numerically and experimentally. The experimental results were obtained on a thrust stand capable of micro-Newton resolution. Thrust and mass flow (hence specific impulse) were measured for an argon propellant at mass flows ranging from 0.4 to 5.5 mg/s. An increase over the cold gas thrust of up to 20% was observed for a discharge frequency of 100 MHz and an input power of 77 W. Propulsive efficiency was seen to increase both experimentally and numerically for increasing mass flow and decreasing discharge frequency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Micro differential thermal analysis detection of adsorbed explosive molecules using microfabricated bridges

Although micromechanical sensors enable chemical vapor sensing with unprecedented sensitivity using variations in mass and stress, obtaining chemical selectivity using the micromechanical response still remains as a crucial challenge. Chemoselectivity in vapor detection using immobilized selective layers that rely on weak chemical interactions provides only partial selectivity. Here we show that the very low thermal mass of micromechanical sensors can be used to produce unique responses that can be used for achieving chemical selectivity without losing sensitivity or reversibility. We demonstrate that this method is capable of differentiating explosive vapors from nonexplosives and is additionally capable of differentiating individual explosive vapors such as trinitrotoluene, pentaerythritol tetranitrate, and cyclotrimethylenetrinitromine. This method, based on a microfabricated bridge with a programmable heating rate, produces unique and reproducible thermal response patterns within 50 ms that are characteristic to classes of adsorbed explosive molecules. We demonstrate that this micro-differential thermal analysis technique can selectively detect explosives, providing a method for fast direct detection with a limit of detection of 600 x 10{sup -12} g.

Senesac, Larry R↗

Micro-CT Imaging of Rat Bone and Lumber Vertebra using Synchrotron Radiation

Micro-tomographic imaging with a spatial resolution on the micrometer scale offers owes a high potential to perform certain types of measurements that were not feasible with other techniques or conventional laboratory methods. The synchrotron X-ray source gives substantial advantages because of its high brilliance and continuous X-ray spectrum. Based on this, visualized the microstructure of rat bone and lumber vertebra was visualized using 20, 25 and 30 keV synchrotron X-rays. We utilized the data which was acquired at different energies for multi-model imaging and to estimate the Ca/P ratio. Up to now there has been no research carried out using these images for the estimation of the calcium content, with synchrotron X-rays. The results are based on the analysis of images and gray values obtained at different energies. We introduce this new method in order to measure the calcium content by means of high resolution synchrotron micro-CT.

60 APPLIED LIFE SCIENCES↗

Influence of gas pressure and applied voltage on Xe excimer radiation from a micro dielectric barrier discharge for plasma display panel

We present the influence of gas pressure and applied voltage on Xe excimer radiation from a microdielectric barrier discharge (micro-DBD) in Ne/Xe gas mixture for plasma display panel. Measurements show that the excimer radiation with the 172 nm band lines is strongly observed in the afterglow, and drastically increases with an increase in gas pressure and applied voltage. It is also found that for high gas pressure and low voltage, excimer molecule (Xe{sub 2}{sup *}) is efficiently produced because of less infrared emission from Xe excited atom. The reaction processes of Xe metastable atom (Xe{sub 1s5}{sup *}), which is a precursor for Xe{sub 2}{sup *}, are theoretically analyzed using a one-dimensional fluid model. Increasing gas pressure results in large excimer radiation due to the enhancement of the following three processes, i.e., the conversion process from Xe{sub 1s5}{sup *} to Xe{sub 2}{sup *}, the direct electron impact excitation from ground state to Xe{sub 1s5}{sup *}, and the collisional de-excitation process from upper level (Xe{sup **}) to Xe{sub 1s5}{sup *}. The simulation analytical result shows that for lower voltage, Xe{sub 1s5}{sup *} is efficiently produced due to the increase in the ratio of direct excitation to Xe{sub 1s5}{sup *} from ground state and the suppression of the stepwise ionization from Xe{sub 1s5}{sup *} by electron collisions. While for high voltage operation of micro-DBD, the recombination process with Xe molecular ion (Xe{sub 2}{sup +}) and electron contributes to the total excimer radiation, which can be responsible for the large excimer radiation observed in experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Micro-focused Small Angle Neutron Scattering and Imaging for Science and Engineering Using RTP--A Preliminary Study

Malaysian Nuclear Agency's (Nuclear Malaysia) Small Angle Neutron Scattering (SANS) facility--(MYSANS)--is utilizing low flux of thermal neutron at the agency's 1 MW TRIGA reactor. As the design nature of the 8 m SANS facility can allow object resolution in the range between 5 and 80 nm to be obtained. It can be used to study alloys, ceramics and polymers in certain area of problems that relate to samples containing strong scatterers or contrast. The current SANS system at Malaysian Nuclear Agency is only capable to measure Q in limited range with a PSD (128x128) fixed at 4 m from the sample. The existing reactor hall that incorporate this MYSANS facility has a layout that prohibits the rebuilding of MYSANS therefore the position between the wavelength selector (HOPG) and sample and the PSD cannot be increased for wider Q range. The flux of the neutron at current sample holder is very low which around 10{sup 3} n/cm{sup 2}/sec. Thus it is important to rebuild the MYSANS to maximize the utilization of neutron. Over the years, the facility has undergone maintenance and some changes have been made. Modification on secondary shutter and control has been carried out to improve the safety level of the instrument. A compact micro-focus SANS method can suit this objective together with an improve cryostat system. This paper will explain some design concept and approaches in achieving higher flux and the modification needs to establish the micro-focused SANS.

36 MATERIALS SCIENCE↗

Nuclear waste repository research at the micro- to nanoscale

Micro- and nano-focused synchrotron radiation techniques to investigate determinant processes in contaminant transport in geological media are becoming especially an increasingly used tool in nuclear waste disposal research. There are a number of reasons for this but primarily they are driven by the need to characterize actinide speciation localized in components of heterogeneous natural systems. We summarize some of the recent research conducted by researchers of the Institute of Nuclear Waste Disposal (INE) at the Karlsruhe Institute of Technology using micro- and nano-focused X-ray beams for characterization of colloids and their interaction with minerals and of elemental and phase distributions in potential repository host rocks and actinide speciation in a repository natural analogues sample. Such investigations are prerequisite to ensuring reliable assessment of the long term radiological safety for proposed nuclear waste disposal sites.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

THE ADIABATIC DEMAGNETIZATION REFRIGERATOR FOR THE MICRO-X SOUNDING ROCKET TELESCOPE

The Micro-X Imaging X-ray Spectrometer is a sounding rocket payload slated for launch in 2011. An array of Transition Edge Sensors, which is operated at a bath temperature of 50 mK, will be used to obtain a high resolution spectrum of the Puppis-A supernova remnant. An Adiabatic Demagnetization Refrigerator (ADR) with a 75 gram Ferric Ammonium Alum (FAA) salt pill in the bore of a 4 T superconducting magnet provides a stable heat sink for the detector array only a few seconds after burnout of the rocket motors. This requires a cold stage design with very short thermal time constants. A suspension made from Kevlar strings holds the 255 gram cold stage in place. It is capable of withstanding loads in excess of 200 g. Stable operation of the TES array in proximity to the ADR magnet is ensured by a three-stage magnetic shielding system which consists of a superconducting can, a high-permeability shield and a bucking coil. The development and testing of the Micro-X payload is well underway.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of fast (sub-minute) micro-tomography

An x-ray fast micro-tomography system was developed at medical and imaging beamline BL20B2 in SPring-8. We attempted a 'continuous rotation method' whereby the sample keeps rotating in the beam during the measurement. The image acquisitions are synchronized with the trigger pulses branched from the stepper motor controller. An electron multiplier (EM)-CCD camera (C9100-02, 1000x1000 pixels, 30 fps, 8 {mu}m/pixel, Hamamatsu Photonics) and beam-monitor AA40P (Hamamatsu Photonics) were used as an image detector. The effective pixel size of the detector was 4.9 {mu}m/pixel and the spatial resolution was about 15 {mu}m. The total measurement time for 900 projections has been reduced to 36 s. The reconstruction time was also reduced using GPGPU and SSD system. Using these techniques, preliminary experiment for 4-D (time resolved 3-D) micro-imaging has also been performed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Femtosecond Laser Micro-structuring Of Transparent Materials And Its Ophthalmologic Applications

We have successfully fabricated in vitro femtosecond laser micro-incisions inside cornea and--for the first time--inside sclera mildly pre-cleared by a biocompatible and clinically safe (non-toxic) natural agent (replacive refractive index-matching 40%-glucose solution in water), with the tissues taken as fresh cool cuts of human cadaver eyes, and reported on basic operational conditions of the micro-surgical procedures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗