Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Future instrumentation and missions for measurements of tropospheric trace species from space: Workshop recommendations

It was recommended that gas filter correlation radiometry and high-resolution interferometry be exploited and expanded for measurements of the distribution of tropospheric trace gases. Instruments and missions were identified and discussed. Several instrument/measurement/mission feasibility studies were recommended, including: a three-layer measurement of carbon monoxide, using a nadir-viewing gas filter correlation radiometer; a lower or middle tropospheric measurement of methane, using a nadir-viewing gas filter correlation radiometer; and a survey of lower, middle, and upper tropospheric trace gases using a nadir-viewing high-resolution interferometer operating in the thermal emission mode. It was also concluded that lidar systems appear to have the potential of obtaining measurments of tropospheric trace gases and aerosols from space. In addition to the specific instrument/mission recommendations, the panels made several general recommendations that may lead to future spaceborne instruments, techniques, and missions for tropospheric research.

Source record↗

Instrumentation and data acquisition systems

A comprehensive and integrated measurement system was identified and a design and development effort initiated to meet the criteria imposed by the National Transonic Facility operating environment. Specific measurement areas receiving concentrated attention include: data acquisition, force measurement, pressure instrumentation, flow visualization techniques, model attitude and model deformation measurement, and temperature measurement. The NTF instrument complex will be centered around four 32-bit, 1-microsecond-cycle-time central processing units connected in a multipoint-distributed network configuration. The principal activities to be supported by these computers are: (1) data base management and processing; (2) research measurement data acquisition and display; (3) tunnel and model control; and (4) process monitoring and communication control. The distributed network approach was chosen to modularize the functional software into definable and implementable parts by the various groups involved in the design and to permit use of similar hardware configurations to improve reliability and maintainability.

Guarino, J. F.↗

Experimental active and passive dosimetry systems for the NASA Skylab program

Active and passive dosimetry instrumentation to measure absorbed dose, charged particle spectra, and linear energy transfer spectra inside the command module and orbital workshop on the Skylab program were developed and tested. The active dosimetry system consists of one integral unit employing both a tissue equivalent ionization chamber and silicon solid state detectors. The instrument measures dose rates from 0.2 millirad/hour to 25 rads/hour, linear energy transfer spectra from 2.8 to 42.4 Kev/micron, and the proton and alpha particle energy spectra from 0.5 to 75 Mev. The active dosimeter is equipped with a portable radiation sensor for use in astronaut on-body and spacecraft shielding surveys during passage of the Skylab through significant space radiations. Data are transmitted in real time or are recorded by onboard spacecraft tape recorder for rapid evaluation of the radiation levels. The passive dosimetry systems consist of twelve (12) hard-mounted assemblies, each containing a variety of passive radiation sensors which are recoverable at the end of the mission for analysis.

Schneider, M. F.↗

Cloud Physics Lidar: Instrument Description and Initial Measurement Results

The Cloud Physics Lidar (CPL) is a new custom-built instrument for the NASA ER-2 high-altitude aircraft. The CPL can provide multiwavelength measurements of cirrus, subvisual cirrus, and aerosols with high temporal and spatial resolution. Its state-of-the-art technology gives it a high repetition rate, and photon-counting detection, and includes a low-pulse-energy laser. The CPL was first deployed at the Southern African Regional Science Initiative's 2000 field campaign during August and September 2000. This paper provides an overview of the instrument and initial data results to illustrate the measurement capability of the CPL.

McGill, Matthew↗

Towards a Preservation Content Standard for Earth Observation Data

Information from Earth observing missions (remote sensing with airborne and spaceborne instruments, and in situ measurements such as those from field campaigns) is proliferating in the world. Many agencies across the globe are generating important datasets by collecting measurements from instruments on board aircraft and spacecraft, globally and constantly. The data resulting from such measurements are a valuable resource that needs to be preserved for the benefit of future generations. These observations are the primary record of the Earths environment and therefore are the key to understanding how conditions in the future will compare to conditions today. Earth science observational data, derived products and models are used to answer key questions of global significance. In the near-term, as long as the missions data are being used actively for scientific research, it continues to be important to provide easy access to the data and services commensurate with current information technology. For the longer term, when the focus of the research community shifts toward new missions and observations, it is essential to preserve the previous mission data and associated information. This will enable a new user in the future to understand how the data were used for deriving information, knowledge and policy recommendations and to repeat the experiment to ascertain the validity and possible limitations of conclusions reached in the past and to provide confidence in long term trends that depended on data from multiple missions. Organizations that collect, process, and utilize Earth observation data today have a responsibility to ensure that the data and associated content continue to be preserved by them or are gathered and handed off to other organizations for preservation for the benefit of future generations. In order to ensure preservation of complete content necessary for understanding and reusing the data and derived digital products from todays missions, it is necessary to develop a specification of such preservation content. While there are existing standards that address archival and preservation in general, there are no existing international standards or specifications today to address what content should be preserved. The purpose of this paper is to outline briefly the existing standards that apply to preservation, describe a recent effort in getting an international standard in place for specifying preservation content for Earth observation data and derived digital data products and the remaining work needed to arrive at a standard.

ISO Standards↗

Nitric acid oxide mixing ratio measurements using a rocket launched chemiluminescent instrument

A total of 18 rocket launched parachute borne nitric oxide instruments were launched from 1977 to 1985. A very precise instrument for the measurement of the nitric oxide mixing ratio was fabricated. No changes were made in the main body of the instruments, i.e., things associated with the reaction volume. Except for the last 4 launches, however, it did not yield the required absolute values that was hoped for. Two major problems were encountered. First, the wrong choice of the background calibration gas, nitrogen, caused the first 10 data sets to be too low in the absolute mixing ratio by nearly the order of 2 to 5 ppbv. The error was realized, and air was substituted for the bias gas measurement. Second, in the desire to extend the measurement to higher altitudes, the problem of contaminating the inlet flow tube with ozone from the reagent gas was encountered. The ozone valve was opened too early in the flight and this caused the pressure in the reaction volume to exceed the pressure at the flow tube entrance, permitting the ozone to migrate backwards. This problem was restricted to an altitude above 45 km.

Horvath, Jack J.↗

Considerations for acoustic emission monitoring of spherical Kevlar/epoxy composite pressure vessels

We are continuing to research the applications of acoustic emission testing for predicting burst pressure of filament-wound Kevlar 49/epoxy pressure vessels. This study has focused on three specific areas. The first area involves development of an experimental technique and the proper instrumentation to measure the energy given off by the acoustic emission transducer per acoustic emission burst. The second area concerns the design of a test fixture in which to mount the composite vessel so that the acoustic emission transducers are held against the outer surface of the composite. Included in this study area is the calibration of the entire test setup including couplant, transducer, electronics, and the instrument measuring the energy per burst. In the third and final area of this study, we consider the number, location, and sensitivity of the acoustic emission transducers used for proof testing composite pressure vessels.

Hamstad, M. A.↗

Use of TEMPO as a Proxy for Hyperspectral Geostationary Ocean Color Measurements from the GeoXO OCX Instrument: Harnessing Machine Learning and Principal Component Techniques for Atmospheric and Glint Correction

Retrievals of ocean color from space are important for better understanding the ocean ecosystem. The launch of atmospheric geostationary hyperspectral sensors such as TEMPO, provides a unique opportunity to examine the diurnal variability in ocean ecology. While TEMPO does not have as high spatial resolution or full spectral coverage as planned coastal ocean sensors such as the Geosynchronous Littoral Imaging and Monitoring Radiometer (GLIMR) or GeoXO Ocean Color instrument (OCX), its hourly measurements provide coverage of regions such as Lake Erie and the Gulf of Mexico at spatial scales of approximately 5 km. These data can be useful for testing new algorithms. We will apply our newly developed machine learning based atmospheric correction approach for ocean color retrievals to TEMPO data. Our approach begins by decomposing measured radiances from hyperspectral sensors into spectral features that describe the scattering and absorption of the atmosphere as well as the underlying surface reflectance. The coefficients of the principal components are then used to train a neural network to predict ocean color properties derived from collocated MODIS/VIIRS physically-based retrievals. This machine learning approach does not rely on radiative transfer modeling, and the use of MODIS/VIIRS data for training accounts for possible calibration b in hyperspectral data. Previously, we applied our approach using blue and UV wavelengths with the Ozone Monitoring Instrument (OMI) and TROPOspheric Monitoring Instrument (TROPOMI) to show that it can estimate ocean color properties in less-than-ideal conditions such as lightly to moderately clouded conditions as well as sun glint and thus improve the spatial coverage of ocean color measurements. TEMPO provides an opportunity to improve on this approach since it will provide collocated measurements at green and red wavelengths that were not available from OMI and TROPOMI and are important particularly for coastal waters. Additionally, our technique can be applied early in the mission and has potential to demonstrate the value of near real time ocean color products that are important for monitoring of harmful algae blooms and other oceanic phenomena.

Zachary Fasnacht↗

Miniaturized GC/MS instrumentation for in situ measurements: micro gas chromatography coupled with miniature quadrupole array and paul ion trap mass spectrometers

Miniaturized chemical instrumentation is needed for in situ measurements in planetary exploration and other spaceflight applications where factors such as reduction in payload requirements and enhanced robustness are important. In response to this need, we are 'continuing to develop miniaturized GC/MS instrumentation which combines chemical separations by gas chromatography (GC) with mass spectrometry (MS) to provide positive identification of chemical compounds in complex mixtures of gases, such as those found in the International Space Station's cabin atmosphere. Our design approach utilizes micro gas chromatography components coupled with either a miniature quadrupole mass spectrometer array (QMSA) or compact, high-resolution Paul ion trap.

GC/MC miniature mass spectrometry MEMS↗

Ares I Scale Model Acoustic Test Instrumentation for Acoustic and Pressure Measurements

Ares I Scale Model Acoustic Test (ASMAT) is a 5% scale model test of the Ares I vehicle, launch pad and support structures conducted at MSFC to verify acoustic and ignition environments and evaluate water suppression systems Test design considerations 5% measurements must be scaled to full scale requiring high frequency measurements Users had different frequencies of interest Acoustics: 200 - 2,000 Hz full scale equals 4,000 - 40,000 Hz model scale Ignition Transient: 0 - 100 Hz full scale equals 0 - 2,000 Hz model scale Environment exposure Weather exposure: heat, humidity, thunderstorms, rain, cold and snow Test environments: Plume impingement heat and pressure, and water deluge impingement Several types of sensors were used to measure the environments Different instrument mounts were used according to the location and exposure to the environment This presentation addresses the observed effects of the selected sensors and mount design on the acoustic and pressure measurements

Vargas, Magda B.↗

Surface finish measurement studies

The performance of stylus instruments for measuring the topography of National Transonic Facility (NTF) model surfaces both for monitoring during fabrication and as an absolute measurement of topography was evaluated. It was found that the shop-grade instruments can damage the surface of models and that their use for monitoring fabrication procedures can lead to surface finishes that are substantially out of range in critical areas of the leading edges. The development of a prototype light-scattering instrument which would allow for rapid assessment of the surface finish of a model is also discussed.

Teague, E. C.↗

Error in Dasibi flight measurements of atmospheric ozone due to instrument wall-loss

Theory suggests that in laminar flow the percent loss of a trace constituent to the walls of a measuring instrument varies as P to the -2/3, where P is the total gas pressure. Preliminary laboratory ozone wall-loss measurements confirm this P to the -2/3 dependence. Accurate assessment of wall-loss is thus of particular importance for those balloon-borne instruments utilizing laminar flow at ambient pressure, since the ambient pressure decreases by a factor of 350 during ascent to 40 km. Measurements and extrapolations made for a Dasibi ozone monitor modified for balloon flight indicate that the wall-loss error at 40 km was between 6 and 30 percent and that the wall-loss error in the derived total ozone column-content for the region from the surface to 40 km altitude was between 2 and 10 percent. At 1000 mb, turbulence caused an order of magnitude increase in the Dasibi wall-loss.

Ainsworth, J. E.↗

Progress in speckle-shift strain measurement

The Instrumentation and Control Technology Division of the Lewis Research Center has been developing an in-house capability to make one dimensional and two dimensional optical strain measurements on high temperature test specimens. The measurements are based on a two-beam speckle-shift technique. The development of composite materials for use in high temperature applications is generating interest in using the speckle-shift technique to measure strains on small diameter fibers and wires of various compositions. The results of preliminary speckle correlation tests on wire and fiber specimens are covered, and the advanced system currently under development is described.

Lant, Christian T.↗

Far-infrared emissivity measurements of reflective surfaces

An instrument developed to measure the emissivity of reflective surfaces by comparing the thermal emission of a test sample to that of a reference surface is reported. The instrument can accurately measure the emissivity of mirrors made from lightweight thermally insulating materials such as glass and metallized carbon fiber reinforced plastics. Far infrared measurements at a wavelength of 165 micrometers are reported. The instrument has an absolute accuracy of Delta epsilon = 9 x 10(exp -4) and can reproducibly measure an emissivity of as small as 2 x 10(exp -4) between flat reflective surfaces. The instrument was used to measure mirror samples for balloon-borne and spaceborne experiments. An emissivity of (6.05 +/- 1.24) x 10(exp -3) was measured for gold evaporated on glass, and (6.75 +/- 1.17) x 10(exp -3) for aluminum evaporated on glass.

Xu, J.↗