Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “matching”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Load Matching Potential of Urban Renewables during Extreme Heat in New York City

Integration of renewable resources to meet growing energy demand is becoming a global priority under decarbonization mandates. This study contributes to ongoing efforts on the matter by assessing the feasibility of using offshore wind and rooftop photovoltaic systems to meet electricity demand during a period of thermal stress in New York City—August 2019. A unified modelling framework, based on the Urbanized Weather Research and Forecasting model, is used to simulate climate, renewable resources and energy demand variables. Findings show significant energy load miss-match, ranging from 3 to 5 GW, between the demand and the composite renewable generation outcome. This study provides a transferable framework for evaluating renewable integration in dense urban regions and highlights the need for additional strategies to support grid resilience during extreme heat events, while clarifying the role of local resources in fully managing NYC’s load.

54 ENVIRONMENTAL SCIENCES↗

Energy Conversion Properties of ZnSiP2, a Lattice-Matched Material for Silicon-Based Tandem Photovoltaics

ZnSiP2 demonstrates promising potential as an optically active material on silicon. There has been a longstanding need for wide band gap materials that can be integrated with Si for tandem photovoltaics and other optoelectronic applications. ZnSiP2 is an inexpensive, earth abundant, wide band gap material that is stable and lattice matched with silicon. This conference proceeding summarizes our PV-relevant work on bulk single crystal ZnSiP2, highlighting the key findings and laying the ground work for integration into Si-based tandem devices.

14 SOLAR ENERGY↗

Automatic Detection and Evaluation of Solar Cell Micro-Cracks in Electroluminescence Images Using Matched Filters

A method for detecting micro-cracks in solar cells using two dimensional matched filters was developed, derived from the electroluminescence intensity profile of typical micro-cracks. We describe the image processing steps to obtain a binary map with the location of the micro-cracks. Finally, we show how to automatically estimate the total length of each micro-crack from these maps, and propose a method to identify severe types of micro-cracks, such as parallel, dendritic, and cracks with multiple orientations. With an optimized threshold parameter, the technique detects over 90 % of cracks larger than 3 cm in length. The method shows great potential for quantifying micro-crack damage after manufacturing or module transportation for the determination of a module quality criterion for cell cracking in photovoltaic modules.

14 SOLAR ENERGY↗

The Power of Exclusion using Automated Osteometric Sorting: Pair‐Matching,

Abstract This study compares the original pair‐matching osteometric sorting model ( J Forensic Sci 2003 ;48:717) against two new models providing validation and performance testing across three samples. The samples include the Forensic Data Bank, USS Oklahoma , and the osteometric sorting reference used within the Defense POW / MIA Accounting Agency. A computer science solution to generating dynamic statistical models across a commingled assemblage is presented. The issue of normality is investigated showing the relative robustness against non‐normality and a data transformation to control for normality. A case study is provided showing the relative exclusion power of all three models from an active commingled case within the Defense POW / MIA Accounting Agency. In total, 14,357,220 osteometric t ‐tests were conducted. The results indicate that osteometric sorting performs as expected despite reference samples deviating from normality. The two new models outperform the original, and one of those is recommended to supersede the original for future osteometric sorting work.

Lynch, Jeffrey James↗

An Automated Two‐dimensional Pairwise form Registration Method for Pair‐matching of Fragmented Skeletal Remains

Abstract This study introduces an automated pairwise method for osteological pair‐matching of fragmented skeletal remains using two‐dimensional fragmented outlines extracted from photographs. The form data are used in pairwise iterative closest point registrations with rigid transformations. A modified version of the average Hausdorff distance is calculated to remove any coordinate correspondences with outline fracture margins, which allow the distance analysis of fragmented outlines. A dilation modification to the Hausdorff distance is proposed creating a greater separation between true‐ and false‐pairs. The sample consists of 122 calcanei (61 pairs) from the UI ‐Stanford collection. Performance statistics are provided for simulated fragmented and complete assemblages. Results indicate up to 98% accuracy for fragmented and complete assemblages. The dilated Hausdorff distance performed similarly across assemblages, but showed a slight decrease in performance for the complete assemblage. This approach provides a useful short listing tool to reduce the number of visual comparisons required in large commingled assemblages.

Lynch, Jeffrey James↗

Sealing glass-ceramics with near-linear thermal strain, part III: Stress modeling of strain and strain rate matched glass-ceramic to metal seals

Thermal mechanical stresses of glass-ceramic to stainless steel (GCtSS) seals are analyzed using finite element modeling over a temperature cycle from a set temperature (T set ) 500°C to -55°C, and then back to 600°C. There are two glass-ceramics that have an identical coefficient of thermal expansion (CTE) at ~16 ppm/°C but have very different linearity of thermal strains, designated as near-linear NL16 and step-like SL16, and were formed from the same parent glass using different crystallization processes. Stress modeling reveals much higher plastic strain in the stainless steel using SL16 glass-ceramic when the GCtSS seal cools from T set . Upon heating tensile stresses start to develop at the GC-SS interface before the temperature reaches T set . On the other hand, the much lower plastic deformation in stainless steel accumulated during cooling using NL16 glass-ceramic allows for radially compressive stress at the GC-SS interface to remain present when the seal is heated back to T set . Finally, the qualitative stress comparison suggests that with a better match of thermal strain rate to that of stainless steel, the NL16 glass-ceramic not only improves the hermeticity of the GCtSS seals, but would also improve the reliability of the seals exposed to high-temperature and/or high-pressure abnormal environments.

36 MATERIALS SCIENCE↗

Localizing intracavitary brachytherapy applicators from cone-beam CT x-ray projections via a novel iterative forward projection matching algorithm

Purpose: To present a novel method for reconstructing the 3D pose (position and orientation) of radio-opaque applicators of known but arbitrary shape from a small set of 2D x-ray projections in support of intraoperative brachytherapy planning. Methods: The generalized iterative forward projection matching (gIFPM) algorithm finds the six degree-of-freedom pose of an arbitrary rigid object by minimizing the sum-of-squared-intensity differences (SSQD) between the computed and experimentally acquired autosegmented projection of the objects. Starting with an initial estimate of the object's pose, gIFPM iteratively refines the pose parameters (3D position and three Euler angles) until the SSQD converges. The object, here specialized to a Fletcher-Weeks intracavitary brachytherapy (ICB) applicator, is represented by a fine mesh of discrete points derived from complex combinatorial geometric models of the actual applicators. Three pairs of computed and measured projection images with known imaging geometry are used. Projection images of an intrauterine tandem and colpostats were acquired from an ACUITY cone-beam CT digital simulator. An image postprocessing step was performed to create blurred binary applicators only images. To quantify gIFPM accuracy, the reconstructed 3D pose of the applicator model was forward projected and overlaid with the measured images and empirically calculated the nearest-neighbor applicator positional difference for each image pair. Results: In the numerical simulations, the tandem and colpostats positions (x,y,z) and orientations ({alpha},{beta},{gamma}) were estimated with accuracies of 0.6 mm and 2 deg., respectively. For experimentally acquired images of actual applicators, the residual 2D registration error was less than 1.8 mm for each image pair, corresponding to about 1 mm positioning accuracy at isocenter, with a total computation time of less than 1.5 min on a 1 GHz processor. Conclusions: This work describes a novel, accurate, fast, and completely automatic method to localize radio-opaque applicators of arbitrary shape from measured 2D x-ray projections. The results demonstrate {approx}1 mm accuracy while compared against the measured applicator projections. No lateral film is needed. By localizing the applicator internal structure as well as radioactive sources, the effect of intra-applicator and interapplicator attenuation can be included in the resultant dose calculations. Further validation tests using clinically acquired tandem and colpostats images will be performed for the accurate and robust applicator/sources localization in ICB patients.

60 APPLIED LIFE SCIENCES↗

SU-E-E-11: Novel Matching Module for Respiration-Gated Motion Tumor of Cone-Beam Computed Tomography (CBCT) to 4DCT

Purpose: Four dimensional computed tomography (4DCT) scans reliably record whole respiratory phase and generate internal target volumes (ITV) for radiotherapy planning. However, image guiding with cone-beam computed tomography (CBCT) cannot acquire all or specific respiratory phases. This study was designed to investigate the correlation between average CT and Maximum Intensity Projection (MIP) from 4DCT and CBCT. Methods: Retrospective respiratory gating were performed by GE Discovery CT590 RT. 4DCT and CBCT data from CRIS Dynamic Thorax Phantom with simulated breathing mode were analyzed. The lung tissue equivalent material encompassed 3 cm sphere tissue equivalent material. Simulated breathing cycle period was set as 4 seconds, 5 seconds and 6 seconds for representing variation of patient breathing cycle time, and the sphere material moved toward inferior and superior direction with 1 cm amplitude simulating lung tumor motion during respiration. Results: Under lung window, the volume ratio of CBCT scans to ITVs derived from 10 phases average scans was 1.00 ± 0.02, and 1.03 ± 0.03 for ratio of CBCT scans to MIP scans. Under abdomen window, the ratio of CBCT scans to ITVs derived from 10 phases average scans was 0.39 ± 0.06, and 0.06 ± 0.00 for ratio of CBCT scans to MIP scans. There was a significant difference between lung window Result and abdomen window Result. For reducing image guiding uncertainty, CBCT window was set with width 500 and level-250. The ratio of CBCT scans to ITVs derived from 4 phases average scans with abdomen window was 1.19 ± 0.02, and 1.06 ± 0.01 for ratio of CBCT to MIP scans. Conclusion: CBCT images with suitable window width and level can efficiently reduce image guiding uncertainty for patient with mobile tumor. By our setting, we can match motion tumor to gating tumor location on planning CT more accurately neglecting other motion artifacts during CBCT scans.

60 APPLIED LIFE SCIENCES↗

Experimental verification of the technique for calculating a plasma opening switch and its matching to the load

A technique for calculating a plasma opening switch in an external magnetic field and its matching to a load the impedance of which increases with time was verified experimentally. The experiments were performed in the RS-20 facility both in the absence of a load and with various inductive loads. The amplitude of the voltage pulse at the input of the plasma opening switch was 0.36-0.84 MV, the current amplitude was 280-320 kA, and the pulse duration was {approx}2 {mu}s, whereas the corresponding parameters of the output pulse were 0.8-3.2 MV, 0-240 kA, and {approx}100 ns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the Fabrication and Study of Lattice-Matched Heterostructures for Quantum Cascade Lasers

The fabrication and study of the characteristics of a lattice-matched quantum cascade laser structure on an indium-phosphide substrate, designed for a wavelength of ~4.8 μm corresponding to one of the atmospheric windows are described. The heterostructure grown by molecular-beam epitaxy consisted of thirty cascades. Lasing was experimentally observed at temperatures up to 200 K at a wavelength coinciding with the calculated one, which confirms the high heterointerface quality and high precision of the layer thicknesses and active-region doping levels.

36 MATERIALS SCIENCE↗

Matrix element corrections in the PYTHIA8 parton shower in the context of matched simulations at next-to-leading order

We discuss the role of matrix element corrections (MEC) to parton showers in the context of MC@NLO-type matchings for processes that feature unstable resonances, where MEC are liable to result in double-counting issues, and are thus generally not employed. By working with PYTHIA8 , we show that disabling all MEC is actually unnecessary in computations based on the narrow-width approximation, and we propose alternative MEC settings which, while still avoiding double counting, allow one to include hard-recoil effects in the simulations of resonance decays. We illustrate our findings by considering $t\overline{t}$ production at the LHC, and by comparing MadGraph5-aMC@NLO predictions with those of POWHEG-BOX and standalone PYTHIA8 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Parallel Maximum Cardinality Matchings via Tree-Grafting

This software implements a new algorithm and its shared-memory parallelization for computing maximum cardinality matchings in bipartite graphs. The algorithm searches for augmenting paths via specialized breadth-first searches (BFS) from multiple source vertices, hence creating more parallelism than single source algorithms.

Buluc, Aydin↗

Smart Spectral Matching (SSM)

Smart Spectral Matching (SSM) catalogs spectroscopic data and, within the platform, investigates subtle attributes of spectral signatures from Raman and infrared spectroscopic data and enables statistical identification of connections between underlying structural units and spectroscopic information, particularly in fuel cycle materials that are amorphous or a mixture of several phases. Catalogs spectroscopic data, provides UIs for machine learning training either via JupyterHub for notebooks or domain scientist-specific views, machine learning and catalog REST API Python client libraries, and ability to identify features in files uploaded using pre-trained machine learning models. This is a "service-based" architecture with multiple applications represented by each repository in the group https://github.com/smart-spectral-matching

McDonnell, Marshall [Oak Ridge National Lab. (ORNL↗

Grid Event Signature Library's Signature Matching Tool

The Signature Matching Tool (SMT) is a tool that assists users in labeling any unlabeled signatures, according to the hierarchical, event tags taxonomy developed for the Department of Energy's (DOE) Grid Event Signature Library (GESL).

Joo, Jhi Young [Lawrence Livermore National Labora↗

Optimal damping profile ratios for stabilization of perfectly matched layers in general anisotropic media

Conventional perfectly matched layers (PML) can be unstable for certain kinds of anisotropic media. Multi-axial PML removes such instability using nonzero damping coe cients in the directions tangential with the PML interface. While using non-zero damping pro le ratios can stabilize PML, it is important to obtain the smallest possible damping pro le ratios to minimize arti cial re ections caused by these non-zero ratios, particularly for 3D general anisotropic media. Using the eigenvectors of the PML system matrix, we develop a straightforward and e cient numerical algorithm to determine the optimal damping pro le ratios to stabilize PML in 2D and 3D general anisotropic media. Numerical examples show that our algorithm provides optimal damping pro le ratios to ensure the stability of PML and complex-frequency-shifted PML for elastic-wave modeling in 2D and 3D general anisotropic media.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Survival Impact of Locoregional Treatment of the Primary Tumor in De Novo Metastatic Breast Cancers in a Large Multicentric Cohort Study: A Propensity Score-Matched Analysis

Introduction: Improvement in overall survival (OS) by locoregional treatment (LRT) of the primary tumor in de novo metastatic breast cancer (MBC) patients remains controversial. Objective: The aim of our study was to evaluate the impact of LRT on OS in a large retrospective cohort of de novo MBC patients, with regard to immunohistochemical characteristics and pattern of metastatic dissemination. Methods: We conducted a multicentric retrospective study of patients diagnosed with de novo MBC selected from the French Epidemiological Strategy and Medical Economics MBC database (NCT03275311) between 2008 and 2014. Overall, 4276 women were included in the study. LRT comprised either radiotherapy, surgery, or both. Results: LRT was used in 40% of patients. Compared with no LRT, patients who received LRT were younger (p < 0.0001) and were more likely to have only one metastatic site (p < 0.0001) or bone-only metastases (p < 0.0001). LRT was associated with a significantly better OS based on landmark multivariate analysis at 1-year (hazard ratio 0.65, 95% confidence interval 0.55–0.76, p < 0.001). Similar results were observed in all sensitivity analyses, including propensity score matching. In subgroup analysis, LRT was associated with better OS in patients with hormone receptor-positive/human epidermal growth factor receptor 2 (HER2)-negative (61.6 vs. 45.9 months, p < 0.001) and HER2-positive tumors (77.2 vs. 52.6 months, p = 0.008), but not in triple-negative tumors (19 vs. 18.6 months, p = 0.54), and was also associated with a reduction in the risk of death in visceral metastatic patients (p < 0.001). Conclusions: LRT was associated with a significantly better OS in de novo MBC patients, including patients with visceral involvement at diagnosis; however, LRT did not impact OS in triple-negative MBC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interferometric technique for faceted microstructure metrology using an index matching liquid

Microstructured optical products are becoming more widespread due to advances in manufacturing. Many of these structures contain faceted surfaces with steep slopes. Adequate metrology for such surfaces is lacking. We describe an interferometric technique that combines plane wave illumination with an index matching liquid to achieve high quality, high speed measurements of such faceted microstructures. We account for refraction at the interfaces, rather than consider only optical path length changes due to the index liquid, and this significantly improves the facet angle measurement. We demonstrate the technique with the measurement of an array of micropyramids and show that our results are in good agreement with measurements taken on a contact profilometer. We also extend the technique to measure opaque microcorner cubes by implementing an intermediate replication step.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single-shot cross-correlation of counter-propagating, short optical pulses using random quasi-phase-matching

The single-shot cross-correlation of the short optical pulses generated by two laser facilities is acquired using random quasi-phase-matching of the counter-propagating beams in a disordered ferroelectric crystal. Transverse sum–frequency generation of the two counter-propagating pulses at different central wavelengths yields their time-dependent background-free cross-correlation after spectral filtering. Their relative delay is directly determined on every shot from the measured cross-correlation, making it a simple diagnostic for jitter studies and temporal characterization.

47 OTHER INSTRUMENTATION↗