Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Primary Heat Transport System Design Considerations for Xcimer Energy’s Athena Fusion Pilot Plant

Fusion energy promises a reliable, carbon-free source of power; however, significant challenges remain before it can be deployed as an economical energy source. In addition to achieving fusion conditions, power plants must operate under extreme temperatures, radiation, and mechanical loads while maintaining high efficiency and availability. These requirements place strong demands on engineering design and plant operation. This work focuses on the engineering challenges associated with balance of plant analysis for inertial fusion energy systems. In particular, this paper examines the design considerations for primary heat transfer systems in fusion pilot plants employing molten fluoride salt coolants, with particular emphasis on system layout optimization and the balance between competing design objectives using the Xcimer Energy Athena inertial pilot plant design as a case study. Through systematic analysis of candidate system configurations and parametric sensitivity studies, we identify key engineering trade-offs governing salt inventory, pumping power requirements, and operational flexibility. The analysis employs system-level modeling tools to explore the design space and establish relationships between geometric parameters and system performance metrics.

Greenwood, Scott [ORNL] (ORCID:0000000333480736)↗

Efficient and Robust Dynamic Simulation of Power Systems With Holomorphic Embedding

Dynamic simulation is vitally important in power system analysis, but traditional approaches based on numerical integration over small time steps are time-consuming. Also, the Newton-Raphson method suffers from difficulty in convergence when solving nonlinear algebraic equations. In this paper, we propose a novel dynamic simulation approach based on holomorphic embedding. By obtaining a high-order approximation of system dynamics, it achieves a much larger time step and thus enhances the computational efficiency significantly. In addition, the new approach avoids non-convergence issues in solving algebraic equations, which improves robustness. The approach includes flexible modeling of synchronous generators and controllers, and we propose a method for modeling generator coordinate transformations. The approach is tested on the IEEE 39-bus, 10-generator system and a Polish 2383-bus, 327-generator system. The results demonstrate promising computational efficiency and satisfactory numerical robustness for the analysis of large-scale power systems.

42 ENGINEERING↗

Electrification Futures Study: Scenarios of Power System Evolution and Infrastructure Development for the United States

This report is one in a series of Electrification Futures Study (EFS) publications. The EFS is a multiyear research project to explore potential widespread electrification in the future energy system of the United States. Electrification is defined as the substitution of electricity for direct combustion of non-electricity-based fuels used to provide similar services. The EFS is specifically designed to examine electric technology advancement and adoption for end uses in the major economic sectors of the United States, electricity consumption growth and load profiles, future power system infrastructure development and operations, and economic and environmental implications of electrification. Because of the expansive scope and the multiyear duration of the study, research findings and supporting data will be published as a series of reports, with each report being released on its own time frame.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

General Testing Setup for Hyperelastic Transducers-DEEC-Tec & Marine Renewable Energy: Preprint

Distributed embedded energy conversion technologies (DEEC-Tec), an emerging domain for ocean wave energy conversion technology, is showing promise for a range of applications. Research is being conducted at the National Renewable Energy Laboratory that leverages this domain to investigate the potential of ocean wave energy converters (WECs) constructed from hyperelastic forms of distributable and embeddable energy transducers. These transducers are available in forms such as disks, rectangles, or hexagons and can be combined in various ways to form energy-producing metamaterials and flexible WECs. DEEC-Tec, therefore, could open doors that enhance ocean wave energy conversion in ways not previously thought possible by allowing for many WEC topologies and morphologies. However, the same diversity and adaptability pose challenges for the development of these DEEC-Tec-oriented hyperelastic transducers. A commercial tensile testing setup was not found that was adaptable enough to accommodate the varied transducers while providing precise force control, range of motion, and noncontact data collection. Because of this lack, a comprehensive test rig was designed in house to be used with a 3D laser scanning device-providing contactless measurements while also allowing for different geometries and various uniaxial loadings. This paper and presentation will discuss these unique challenges and the processes for overcoming them to provide a robust and general testing setup for hyperelastic transducers, of any form, for the DEEC-Tec marine renewable energy domain.

DEEC-Tec↗

Simulation of 15% and 50% Thermal Power Dispatch to an Industrial Facility Using a Flexible Generic Full-Scope Pressurized Water Reactor Plant Simulator

Nuclear power plants in the United States are increasingly challenged to compete in wholesale electricity markets due to the low electricity costs and increasingly dynamic grid conditions from competing generation sources. An alternative market for nuclear power is industrial facilities that can use the thermal and/or electrical power generated by a nuclear power plant to offset the economic losses incurred by electricity market challenges. A generic pressurized water reactor (PWR) simulator was used to show the results of a basic design for a generic thermal power extraction system and tests were run using a set of procedures to show what happens when a nuclear power plant transitions from full electrical power dispatch to 15% and 50% thermal power dispatch. This type of operation leads to losses in turbine performance efficiency due to the deviation from the design operating point, but because the thermal power is also used by the industry load without conversion losses, the combined thermal efficiency of the PWR increases. For the 15% case, the thermal efficiency increased from 32% to 41.9%, while for the 50% case, the efficiency increased up to 60.1%. In addition, for 50% thermal power dispatch, the power dissipated by the condenser decreased from approximately 2000 to approximately 1300 MW (thermal), indicating a substantially diminished impact on the environment in terms of releasing heat into the cooling water reservoir.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hybridization Assessment of Trybrid Pumped Storage Hydropower System—Part 1: A Case Study of Corral Summit

This report is a part of the deliverables for technical assistance provided to Cat Creek Energy for the Coral Summit Trybrid (Triple Hybrid-Pumped Storage Hydropower, Battery Energy Storage System, and photovoltaic solar energy) energy project. This report explores the operational benefits and challenges of hybridizing an open loop PSH (200MW) located at Mackay, Custer County, Idaho with solar PV (Ground mount 300MW and floating 40MW) and battery (720MWhr). This document reports two activities performed as a part of the hybridization assessment task 1) optimal resource allocation and energy management strategy, and 2) power quality and reliability assessment. From optimal resource allocation and energy management strategy (activity 1), the following key findings can be observed: • Conventional PSH (CPSH) with two reversible pump turbines and separate penstocks can provide required flexibility equivalent to that from two ternary PSH with separate penstock. With single unit CPSH, upper reservoir head cannot be maintained accurately, the variation of water level is rapid and pump mode flexibility is not available. These disadvantages can be overcome by single unit TPSH. However, using two CPSH units with separate penstocks also overcome these disadvantages with the formation of the hydraulic short circuit between two conventional units. • Flooding of the lower reservoir is a severe concern when considering continuous operation for black start. This limits the duration of continuous operation from PSH alone to around 50 hours. Due to the complementary PV and battery action, the duration of continuous operation and smooth power output can be extended. • An optimization problem is framed that maximizes the power output on an hourly basis while minimizing constraint violations and respecting seasonal variations of solar PV and load profiles . Two value streams, arbitrage and baseload generation are served by this profile. It was uncovered that for smooth power output during regular operation, PV curtailment will be required, or the battery capacity needs to be increased above 90MW to accommodate additional PV. From power quality and reliability assessment (activity 2) the following takeaway points can be observed: • The Trybrid, when integrated at the Lost River bus, and limited to 250MW in generation mode and -150MW in the pump mode, causes no violation of voltage or flow.

13 - HYDRO ENERGY↗

Design of a supervisory control system for autonomous operation of advanced reactors

Advanced reactors to be deployed in the coming decades will face deregulated energy markets, and may adopt flexible operation to boost profitability. To aid in the transition from baseload to flexible operation paradigm, autonomous operation is sought. This work focuses on the control aspect of autonomous operation. Specifically, a hierarchical control system is designed to support constraint enforcement during routine operational transients. Within the system, data-driven modeling, physics-based state observation, and classical control algorithms are integrated to provide an adaptable and robust solution. A 320 MW Fluoride-cooled High-temperature Pebble-bed Reactor is the design basis for demonstrating the proposed control system. The hierarchical control system consists of a supervisory layer and low-level layer. The supervisory layer receives requests to change the system's operating conditions (e.g., the current reactor power to meet a load -follow), and accepts or rejects them based on constraints that have been assigned. Constraints are issued to keep the plant within an optimal operating region. The low-level layer interfaces with the actuators of the system to fulfill requested changes, while maintaining tracking and regulation duties. Further, to accept requests at the supervisory layer, the Reference Governor algorithm was adopted. To model the dynamics of the reactor, a system identification algorithm, Dynamic Mode Decomposition, was utilized. To estimate the evolution of process variables that cannot be directly measured (e.g., the propagation of delayed neutron precursors), the Unscented Kalman Filter, incorporating a nonlinear model of nuclear dynamics, was adopted. The composition of these algorithms led to a numerical demonstration of constraint enforcement during a 40% power drop transient (at a rate of 5 %/min). Uncontrolled secondary-side temperatures were successfully constrained. Adaptability of the proposed system was demonstrated by modifying the constraint values, and enforcing them during the transient. Robustness was also demonstrated by enforcing constraints under noisy environments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A reforecasting-based dynamic reserve estimation for variable renewable generation and demand uncertainty

The installed capacity of renewables-based energy sources has been increasing in traditional power systems. In order to accommodate the increased variability and uncertainty associated with the deeper penetration of renewable sources like solar and wind, adjusted amounts of dynamic reserve are needed. Although probabilistic dynamic reserve estimation methods have been previously developed, most of them consider the uncertainty to be represented by parametric density functions that tend to perform poorly under extreme events and, moreover, neglect uncertainty introduced by the forecasting model itself. Toward addressing these limitations, this work presents, for the first time, a dynamic reserve estimation method for flexibility that incorporates nonparametric density estimation and a machine learning based reforecasting to provide a day-ahead prediction of the mean and spread of uncertainty around the base forecast. The prediction is, in turn, used to estimate the up and down reserve relative to the base forecast. Here, the present method takes various endogenous and exogenous features, including the calendar variables, as input to estimate the day-ahead reserve. Using a combination of reforecasting and dynamic reserve estimation techniques, the method is shown to adjust better to the dynamic nature of reserve requirements providing only what is needed to accommodate the expected deviations. Considering California Independent System Operator (CAISO) solar, wind and load data over an 18 month period, up to 67% reduction in the amount of reserve capacity needed for a one day reserve and reserve penalty for solar uncertainty is demonstrated. Additionally, the risk of reserve insufficiency in meeting the net demand is reduced by 20% with the proposed method.

14 SOLAR ENERGY↗

Ultraviolet-Activated Solid-State Nitrene Cross-Linking: A Scalable Pathway to Prolonged Lifespan in Anion Exchange Membranes

Anion exchange membranes (AEMs) offer a cost-effective alternative to proton exchange membranes as alkaline fuel cells and electrolyzers permit the use of non-platinum group electrodes and components. Despite continued progress, the operational lifetime and stability of these membranes limit the widespread adoption of AEM-based electrochemical technologies. This study presents a flexible and easily implemented ultraviolet (UV)-initiated nitrene-based cross-linking method which uses a small, facile organic azide precursor. As a proof of concept, we demonstrate this approach on the well-studied poly(2,6-dimethyl-1,4-phenylene oxide) quaternary ammonium AEM (QPPO) polyelectrolyte. Further, a survey of cross-linker density (2.5–10 mol %) found that the addition of 10 mol % results in a 59% reduction in water uptake, a 58.8% decrease in the swell ratio, and a 31% increase in tensile strength vs the un-cross-linked material. Nitrene cross-linking also enhanced the membrane’s durability, enabling 1000 h of stable performance under electrochemical load. This UV-initiated cross-linking method may be easily integrated into production processes, allowing chemical cross-linking at any stage, including posthydration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cell Free and Immobilization Technologies (CFIT)

Today, several key factors negatively impact the production of fuels and chemicals from renewable sources. Common hindrances in the biological production of biochemicals are: (1) end-product or intermediate toxicity to the microbial biocatalyst, (2) the diversion of carbon to biomass formation, and (3) co-production of undesired byproducts. A particularly attractive alternative is to eliminate the biocatalyst entirely and instead operate the desired metabolic pathways in isolation, thus circumventing the roadblocks of biological toxicity, lower yields, and lack of specificity. However, cell-free enzyme systems still suffer from low productivities owing in part to the effects of free diffusion of intermediates, lack of long term enzyme stability, cofactor cost or inefficient recycling rates, and finally, the cost of enzyme production/purification. This project represents a new effort to propose innovative and cost competitive routes to producing biochemicals from a variety of feedstocks using cell free approaches. These routes will help reduce the current risk and cost associated with classical cell free production. Cell free technologies show promise for application to the production of toxic/inhibitory products or products difficult to separate from microbial growth media and can help reduce the production barriers in multiple areas of biological conversion of feedstocks to biochemicals. More specifically, we are developing new technologies and routes that could be used to produce high value biochemicals such as 2,3 BDO and terpenes (among many others) from biomass derived C5/C6 sugars or lignin but also from waste byproducts such as glycerol. This project will lead to significant innovation and also lead to new concepts and rational design of pathways and enzymes. Within this project, we will develop new metabolic enzyme cascades that will represent natural or artificial combinations of enzymes to produce the desired biochemicals from a variety of feedstocks. We are also developing basic design principals for constructing synthetic metabolons, using fusion proteins and synthetic protein scaffolds, to promote substrate channeling and stability while conserving peak activity. Additionally, our efforts include a techno economic analysis (TEA) of cell free approaches to provide the sensitivities of the process to enzyme loading, activity, pH, reactor volumes, cofactor recycling rates. Finally, we are focusing on further increasing stability, operating lifetime and efficiency of the pathway enzymes by immobilization on support surfaces. We are also focus on immobilizing pathway enzymes or combinations of enzymes on several different conducting polymers and evaluate the effect on stability and operating lifetime. As more combinations become available we will conduct a more systematic study of the means of immobilizing these enzymes. This preliminary work will enable the in-depth study of cofactor recycling at these interfaces using mediators for electron transfer. Taken together, these approaches will enable process intensification, continuous operation, lower capital and separations costs and end-product flexibility, and thus has the potential to contribute significantly to BETO's goals of cost competitive biofuels and bioproducts. To date we have demonstrated 1) the conversion of pyruvate to 2,3 BDO (4 enzymes with cofactor recycling, no additional cofactors needed) at >100g/L (>3g/L/h) using our enzyme tethering approach, 2) Generated mutants of a key redox enzyme with >180- fold improvement in NADH utilization over WT to >85% of NADPH utilization. 3) Produced mevalonate at >10g/L from glucose, limonene at >10g/L from mevalonate and more than >5g/L from glucose with crude enzyme preparations and complete cofactor recycling. 4) successfully generated fully active cross-linked aggregates (CLEAs) of NOX, a cofactor-regenerating water-forming oxidase that is key to our process with increased stability 5) Engineered and identified enzymes able to use the biomimetic cofactor NMN and synthesized new synthetic cofactors.

biocatalysis↗

OpenFAST Modeling of the T-Omega Wind Floating Offshore Wind Turbine System

To reduce the cost of offshore wind energy through a more efficient design of the floating support structure, T-Omega Wind developed a novel lightweight and shallow-draft platform concept that aims to achieve a wave-following behavior without resonance amplification. The rotor and generator are carried by four tower legs with each leg supported by a shallow-draft float at the base. In preparation for a more detailed analysis, a coupled aero-hydro-elastic model of the proposed concept is developed in OpenFAST. The detailed modeling approach is presented, including a novel application of the SubDyn substructure dynamics module of OpenFAST to approximate the loads on the axle tube at the tower top from the rotor hub bearings. Preliminary results obtained with the OpenFAST model by rigidifying the substructure and blades indicate that the original sizing of the design can lead to large hub acceleration in the axial/surge and pitch directions due to platform-pitch motion. The high axial acceleration also potentially leads to large bending moments in the four tower legs. To address these issues, an updated design is developed with, among other changes, increased float spacing at the tower base and improved shear-transmitting geometry of the tower legs. The new design suggests significantly reduced extreme hub accelerations under the same conditions even with structural flexibility and will be further analyzed in the future through full aero-hydro-servo-elastic simulations.

FOWT↗

OpenFAST Modeling of the T-Omega Wind Floating Offshore Wind Turbine System

To reduce the cost of offshore wind energy through a more efficient design of the floating support structure, T-Omega Wind developed a novel lightweight and shallow-draft platform concept that aims to achieve a wave-following behavior without resonance amplification. The rotor and generator are carried by four tower legs with each leg supported by a shallow-draft float at the base. In preparation for a more detailed analysis, a coupled aero-hydro-elastic model of the proposed concept is developed in OpenFAST. The detailed modeling approach is presented, including a novel application of the SubDyn substructure dynamics module of OpenFAST to approximate the loads on the axle tube at the tower top from the rotor hub bearings. Preliminary results obtained with the OpenFAST model by rigidifying the substructure and blades indicate that the original sizing of the design can lead to large hub acceleration in the axial/surge and pitch directions due to platform-pitch motion. The high axial acceleration also potentially leads to large bending moments in the four tower legs. To address these issues, an updated design is developed with, among other changes, increased float spacing at the tower base and improved shear-transmitting geometry of the tower legs. The new design suggests significantly reduced extreme hub accelerations under the same conditions even with structural flexibility and will be further analyzed in the future through full aero-hydro-servo-elastic simulations.

ENGINEERING,WIND ENERGY↗

Utilizing commercial heating, ventilating, and air conditioning systems to provide grid services: A review

The modern power grid faces multiple challenges due to an increase in the adoption of renewable generation, such as dynamically balancing supply and demand at different time scales. Demand side management in buildings plays a vital role in achieving this balance because buildings can provide grid services through a variety of building assets. However, the development of grid-interactive, efficient buildings is still in its infancy, and a systematic and holistic understanding of grid service delivery strategies in terms of energy efficiency, load shifting, load shedding and load modulating is still limited. This paper is a comprehensive review of the development and application of building-level control strategies for utilizing heating, ventilating, and air conditioning systems to provide grid services. These strategies have been investigated through numerical and experimental studies. Control algorithms, such as heuristic rule-based control and model-based control, have been used to enable the automatic control delivery of grid services. The advantages and disadvantages of the strategies are summarized and discussed. Finally, research trends are also identified, which include considering predicted mean vote-based and occupant-based thermal comfort, modeling of occupant behavior, integrating power grid operations with building control, and combining different demand flexibility modes in the control design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal Demand Response Incorporating Distribution LMP with PV Generation Uncertainty

The utilization of aggregated demand-side flexibility via demand response (DR) has become a promising pathway for the integration of renewable energy resources in power systems. Nowadays, there are several management strategies for DR such as the price-based transactive control strategies. However, many of such existing price-based control strategies neglect the physics and operational constraints of the underlying distribution networks when computing the price, raising concerns regarding their theoretical and practical values. This paper studies this issue and investigates optimal DR (ODR) by incorporating the distribution locational marginal price (DLMP). In particular, we discuss DR in connection with DLMPs and propose a multiperiod bilevel optimization problem to find the ODR strategy. Here, the objective is to minimize the peak load, load fluctuation, and payments of load aggregators. In addition, a robust bilevel ODR model is formulated to provide a robust ODR strategy while minimizing operating costs under the worst-case realization of uncertainties; this mitigates the impact of forecasting errors on renewable energy resources. Then, we propose an efficient solution approach by employing the Karush-Kuhn-Tucker conditions and strong duality. Simulation results are presented to illustrate the mutual impacts of the interaction between DR and DLMP and the benefits of the robust ODR strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution Substation Planning Toolkit (dsp-toolkit) v1.0

The Distribution Substation Planning Toolkit (DSP Toolkit) is a software suite designed to streamline the planning and optimization of distribution substations. This toolkit offers a comprehensive set of tools and APIs for data curation, short-term electric load forecasting, and weather-sensitive load adjustment, making it an essential resource for utility companies, engineers, and researchers. Features • Data Preprocessing and Curation: Efficiently manage and preprocess large datasets to ensure high-quality input for analysis. • Short-Term Load Forecasting: Utilize data-driven models to predict short-term electric loads accurately. • Weather-Sensitive Modeling: Automatically adjust load forecasts based on weather data to predict future peak demands more precisely. Uses The DSP Toolkit is ideal for planning and optimizing distribution substations, providing a user-friendly interface and comprehensive documentation. It is suitable for both novice and experienced users, facilitating efficient and accurate planning processes. Advantages • Efficiency: Automates complex planning tasks, reducing manual effort and minimizing errors. • Scalability: Handles large datasets and complex models, making it suitable for large-scale projects. • Community and Support: Open-source with active community contributions, ensuring continuous improvement and support. • Extensibility: Easily extendable with custom modules and plugins, allowing users to tailor the toolkit to their specific needs. The DSP Toolkit stands out by offering a robust, flexible, and user-friendly solution for distribution substation planning. Public Abstract

Li, Han [Lawrence Berkeley National Laboratory (LB↗

Active Sites in the Dealuminated Beta Zeolite-Supported Cobalt Catalyst for Non-Oxidative Ethane Dehydrogenation

Dispersed metal species in siliceous zeolites have been actively studied for non-oxidative dehydrogenation of ethane (NDE). Fundamental insights into the dynamics of metal species in zeolites under reaction conditions have rarely been explored. Herein, we report an atomic level understanding of the dynamics and activity of cobalt (Co) sites in dealuminated Beta zeolite (DeAl-BEA) for NDE during induction and reaction conditions with extensive characterization techniques such as diffuse reflectance UV–vis, solid state nuclear magnetic resonance and X-ray photoelectron, X-ray diffraction along with in situ Fourier transform infrared and X-ray absorption spectroscopy. For a catalyst with 0.5 mass % Co loading, tetrahedral Co 2+ mononuclear sites, di-coordinated to the zeolite framework and with two silanol groups in vicinity (i.e., (≡SiO) 2 Co(HO–Si≡) 2 ), form upon exposure to hydrogen during induction and persist through the NDE reaction. Increasing the Co loading to 3.0 mass % yielded Co sites with similar electronic and coordination structures but slightly elongated Co–O bonds. Upon cooling to room temperature, the Co sites persisted in the same coordination environment, though the disappearance of a feature in the Co K-edge near-edge region revealed changes in the active site’s electronic structure coinciding with modest shifts in bond lengths. The electronic structure and activity of (≡SiO) 2 Co(HO–Si≡) 2 sites were studied comparatively to a few other hypothetical Co 2+ coordination structures, using electronic structure calculations and microkinetic simulations. The simulations showed that NDE is controlled by β-hydride elimination following C–H bond activation and that Co-sites possessing flexibility because of neighboring silanol defects are more active. Interestingly, dinuclear Co–O–Co sites (i.e., (≡SiO)Co(HO–Si≡) 2 –O–(HO–Si≡) 2 Co(≡SiO)) were more active than the mononuclear (≡SiO) 2 Co(HO–Si≡) 2 sites because of favorable hydrogen bonding with the vicinal silanol groups. In conclusion, the present study bridges the gap between the knowledge acquired by ex-situ characterizations and the active sites under the reaction conditions in alkane dehydrogenation chemistry.

36 MATERIALS SCIENCE↗

STOCHASTIC OPTIMAL POWER FLOW FOR REAL-TIME MANAGEMENT OF DISTRIBUTED RENEWABLE GENERATION AND DEMAND RESPONSE (Final Report)

To meet the grand challenge of a sustainable energy future, there has been a surge of interest in renewable energy. Today, the uncertainty associated with renewable resources is handled by using operating reserves. The high penetration of renewable resources, however, introduces difficult-to-control dynamics and challenges for power system operation. Decision support tools are necessary at the bulk system operational level to recognize and efficiently utilize renewable resources and distributed demand response products in concert with traditional grid resources. It is envisaged that responsive load can potentially have very significant cost advantages over either spinning or non-spinning ramping reserve. Critical decisions are made during hour(s)-ahead and real-time power system operation regarding the commitment and dispatch of generators to ensure power delivery is both reliable and economic. These decisions are typically made by a security constrained optimal flow, which determines future generator commitments, dispatches, and ensures adequate reserves are available in the event of a contingency (unexpected outage) or if future system conditions deviate from forecasts. However, security has been always based on a pre-specified subset of contingency constraints whose enforcement does not guarantee security under all possible future possibilities while also giving little or no weight to the likelihood of each contingent event or the severity of its consequences. Existing tools, which are based exclusively on deterministic optimization models, do not yield optimal operational decisions to address these new challenges, in terms of both reliability and cost-effectiveness. This project has focused on developing a stochastic optimal power flow (SOPF) framework, which integrates renewable resource uncertainty, load uncertainty, distributed storage (DS), demand response (DR) products, in a holistic manner to address the uncertainty associated with ever-increasing renewable resources, along with the inclusion of distributed demand response products in future power systems. A proof-of-concept problem was created using the Pennsylvania-Jersey-Maryland (PJM) power system network. Synthetic wind generation was added to the system to simulate 50% wind penetration. A 1-hour test of SOPF operation indicated more than 6% operational cost savings. The project continued by adding the Midwestern Independent System Operator (MISO) as a partner, with focus shifting from SOPF to Stochastic Look-Ahead Unit Commitment (SLAC). Unlike PJM, MISO is faced with significant renewable energy resources within its footprint and is challenged with substantial uncertainty in its operations. The SLAC distinguishes itself from existing tools that operators use. At best, today’s tools solve two to three cases independently, where one or two system parameters, such as forecasted load level (e.g., a low, base, and high forecast), are varied and the resulting scenarios are analyzed independently. The stochastic-based optimization of SLAC leverages statistical information from an ensemble of potential operational scenarios and their respective likelihood. The SLAC output can be translated into valuable information to the operator such as suggested commitments, optimal scheduling and dispatch of resources, reserve requirements at both locational and zonal resolutions, ramping availability and requirements, availability of demand response including operational guidance concerning the near-term and real-time coordination between distributed energy resources, and utilization of distributed storage resources. The developed SOPF/SLAC tool, a stand-alone tool compatible with existing EMSs, will provide system operators with unprecedented visibility, flexibility and predictability to these resources and operational guidance concerning the real-time coordination between DERs and DR/DS products. The game changing and practical impact of this disruptive technology will be dramatic and will usher in a new era in the electric power industry, wherein green energy concepts are fully embraced, and electric power costs are lowered throughout the nation.

42 ENGINEERING↗

Design And Control of Thermal Storage for Ventilative Cooling in Multifamily Buildings (Final Report)

The concept of natural ventilation is to provide a heat sink for cooling the building during the occupancy periods at night and improve indoor thermal comfort during the daytime without or with minimal need for mechanical cooling. Commonly, natural ventilation through the window or mechanical circulation of the air through the ventilation ducts are two key methods used to achieve night ventilation. Due to the increasing electric need for space heating and cooling, renewable energies combined with energy storage systems are receiving attention worldwide nowadays. When designed and controlled properly, this strategy can reduce energy use for cooling, reduce the size of mechanical cooling equipment, reduce peak electrical demand for cooling, and better enable demand flexibility for mechanical cooling equipment. In some cases, ventilative cooling can eliminate the need for mechanical cooling altogether. For these reasons, California’s Building Energy Efficiency Standards have recently added prescriptive requirements that all new single-family residences (in most California climates) must include ventilative cooling systems (aka: “whole house fans”). However, the current standards do not address multifamily buildings because market-available ventilative cooling products are designed for single-family residences and are physically incompatible with many multifamily building archetypes. The results from the study show that the combination of thermal energy storage on building walls along with nighttime ventilation cooling assisted with nighttime ventilation can save total building energy usage by up to 9% and peak load by 16% in moderate climate zones. The controlled nighttime ventilation cooling (activate ventilation only when outdoor conditions are favorable) can also provide total electricity savings of up to 5% and 7% in hot and cold climates, respectively. In the case of moderate climates, kitchen exhaust-assisted nighttime ventilation cooling can eliminate the need for cooling during overnight hours. This can also significantly assist in reducing carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗