Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “large grids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

CHARACTERIZATION AND DEVELOPMENT OF THE ALL–AQUEOUS COPPER THERMALLY REGENERATIVE AMMONIA BATTERY

Low temperature thermal energy is an abundant and untapped energy source for large scale electrical power and energy production around the world. Many different stationary sources such as industrial and thermal power plants produce significant amounts of low temperature heat that goes unused. The primary reason for the energy loss is because the temperature of the heat is often too low for traditional systems to economically generate power from this waste heat. Many different technologies are being researched to produce grid–scale power from low temperature heat to increase grid efficiency, advance decarbonization efforts, and progress electrical power production to a more distributed system. A thermally regenerative battery (TRB) is one promising technology in this space, as it has large power and energy densities relative to competitive technologies and therefore has the potential to disrupt the current power generation mix. TRBs combine two unit operations (a redox flow battery and a distillation column) which are easily scalable and mature, meaning that if a viable TRB chemistry can be identified, its development to pilot and commercial scale can be streamlined. The all–aqueous, copper thermally regenerative ammonia battery (Cuaq–TRAB) was the first TRB that did not use an electrodeposition/dissolution reaction by stabilizing Cu(I) and Cu(II) in the electrolyte, allowing all electroactive species to be stable in an aqueous phase. Through these electrolyte modifications, coulombic efficiency, open circuit potential, and copper solubility all increased, resulting in large gains to power density, energy density, and energy efficiency.

Cross, Nicholas↗

Ensemble‐Based Spatially Distributed CLM5 Hydrological Parameter Estimation for the Continental United States

Abstract One of the major challenges in large‐domain hydrological modeling efforts lies in the estimation of spatially distributed hydrological parameters while simultaneously accounting for their associated uncertainties. Addressing this challenge is particularly difficult in ungauged locations. With growing societal demands for large‐scale streamflow projections to inform water resource management and long‐term planning, evaluating and constraining hydrological parameter uncertainty is increasingly vital. This study introduces a hybrid regionalization approach to enhance hydrological predictions of the Community Land Model version 5 (CLM5) across the Continental United States (CONUS), with a total of 50,629 1/8° grid cells. This hybrid method combines the strengths of two existing techniques: parameter regionalization and streamflow signature regionalization. It identifies ensemble behavioral parameters for each 1/8° grid cell across the CONUS domain, tailored to three distinct streamflow signatures focused on low flows, high flows, and annual water balance. Evaluating this hybrid method for 464 CAMELS (Catchment Attributes and Meteorology for Large‐sample Studies) basins demonstrates a significant improvement in CLM5 hydrological predictions, even in challenging arid regions. In CONUS applications, the derived spatially distributed parameter sets capture both spatial continuity and variation of parameters, highlighting their heterogeneous nature within specific regions. Overall, this hybrid regionalization approach offers a promising solution to the complex task of improving hydrological modeling over large domains for important hydrological applications.

CLM5↗

The impact of development priorities on power system expansion planning in sub-Saharan Africa

Sub-Saharan Africa faces unique barriers to electricity development due to the large proportion of the population that is un-electrified and the prevalence of rural populations. Typically, power system expansion planning models assume all potential consumers can be immediately electrified. This assumption is unrealistic in sub-Saharan Africa, where electrification will likely be a gradual process over a number of years. Furthermore, since a large proportion of the population in sub-Saharan Africa is located in rural regions, the prioritization of these regions may impact how the grid develops. In this research, we develop a multi-period optimization model for power generation and transmission system expansion planning in sub-Saharan Africa. In contrast to existing models, which assume full electrification, we consider a variety of electrification policies and analyze the impact of varying the electrification rate and policy on the cost and resources selected for power system expansion. We test our model on a case study of Rwanda. We find that varying the year in which full electrification is reached has a larger impact on cost and generation capacity than varying the electrification policy does, although, when urban and rural regions are considered equitably, more rooftop solar is built. Varying the electrification policies has a larger impact on transmission expansion than on generation expansion and this impact is amplified when starting from zero initial system capacity rather than the original Rwanda system. Additionally, a sensitivity analysis shows that tightening the bounds on CO 2eq emissions has a large impact on the generation portfolio and cost.

97 MATHEMATICS AND COMPUTING↗

Role of On-Site Generation in Carbon Emissions and Utility Bill Savings under Different Electric Grid Scenarios

Energy-efficient and sustainable technologies are necessary to lower energy and carbon footprints. Many technologies are being pursued to meet the increasing energy demand in buildings. An attractive option is efficient utilization of available energy resources, including renewables, to support current and future building energy needs while targeting grid resiliency, energy, and environmental security at an affordable cost via on-site cogeneration-based approaches. This must include energy-efficient technologies with lower greenhouse gas emissions and optimized cost, performance, and reliability. This paper presents the economic and environmental benefits associated with power technologies such as thermionics and solid oxide fuel cells. Hybrid configurations consisting of heat pumps, power systems, and renewable photovoltaics in cogeneration and trigeneration modes of operation are presented. The role of such technologies in lowering CO2 emissions while improving energy resiliency and serving the needs of underprivileged communities is discussed. The key barriers of affordability and potential solutions for large-scale implementation of these promising technologies are reviewed. Case studies demonstrating the influence of power rating, electrical efficiency, design configuration, carbon dioxide intensity of the grid, and fuel on annual greenhouse gas emissions are presented for residential and commercial buildings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On the Role of Macrophysics and Microphysics in Km-Scale Simulations of Mixed-Phase Clouds During Cold Air Outbreaks

Regional atmospheric models struggle to maintain supercooled liquid in mixed-phase clouds during polar cold-air outbreaks (CAOs). Previous studies focused on the parameterization of aerosol, microphysics and turbulence to understand the origin of this widespread model bias. This study investigates the role of sub-grid cloud fraction parameterizations (CFP) in the simulation of mixed-phase cloud. Km-scale simulations are performed for a large number of CAO cases over Norway, for which continuous ground observations were collected at one site over 6 months. We use a novel analysis that attributes the cloud-radiative errors to deficiencies in specific cloud regimes. We show that the CFP matters for cloud-radiative effects in CAOs, but that it is probably not the primary cause of the lack of liquid water in simulated mixed-phase clouds. Of all the CFP sensitivities explored in this study, the prognostic representation of both liquid and ice shows most promise in increasing the liquid water path. A newly proposed hybrid CFP with prognostic frozen and diagnostic liquid cloud fraction reproduces some of the benefits of the prognostic scheme at reduced cost and complexity. All simulations appear to produce too large precipitation particles. As a result, reducing the snow deposition rate increases the liquid water path and improves the precipitation size distributions, while simulations are less sensitive to reduced riming rates.

54 ENVIRONMENTAL SCIENCES↗

Electricity and natural gas tariffs at United States wastewater treatment plants

Abstract Wastewater treatment plants (WWTPs) are large electricity and natural gas consumers with untapped potential to recover carbon-neutral biogas and provide energy services for the grid. Techno-economic analysis of emerging energy recovery and management technologies is critical to understanding their commercial viability, but quantifying their energy cost savings potential is stymied by a lack of well curated, nationally representative electricity and natural gas tariff data. We present a dataset of electricity tariffs for the 100 largest WWTPs in the Clean Watershed Needs Survey (CWNS) and natural gas tariffs for the 54 of 100 WWTPs with on-site cogeneration. We manually collected tariffs from each utility’s website and implemented data checks to ensure their validity. The dataset includes facility metadata, electricity tariffs, and natural gas tariffs (where cogeneration is present). Tariffs are current as of November 2021. We provide code for technical validation along with a sample simulation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Sustainable layered cathode with suppressed phase transition for long-life sodium-ion batteries

Sodium-ion batteries are among the most promising alternatives to lithium-based technologies for grid and other energy storage applications due to their cost benefits and sustainable resource supply. For the cathode—the component that largely determines the energy density of a sodium-ion battery cell—one major category of materials is P2-type layered oxides. Unfortunately, at high state-of-charge, such materials tend to undergo a phase transition with a very large volume change and consequent structural degradation during long-term cycling. Here we address this issue by introducing vacancies into the transition metal layer of P2-Na$_{0.7}$Fe$_{0.1}$Mn$_{0.75\square}$$_{0.15}$O2 (‘$_{\square}$’ represents a vacancy). The transition metal vacancy serves to suppress migration of neighbouring Na ions and therefore maintain structural and thermal stability in Na-depleted states. Moreover, the specific Na-O-$_{\square}$ configuration triggers a reversible anionic redox reaction and boosts the energy density. As a result, the cathode design here enables pouch cells with energy densities of 170 Wh kg -1 and 120 Wh kg -1 that can operate for over 600 and 1,000 cycles, respectively. In conclusion, our work not only suggests a feasible strategy for cathode design but also confirms the possibility of developing a battery chemistry that features a reduced need for critical raw materials.

25 ENERGY STORAGE↗

Regression Analysis with the Directed Infusion of Data

Integrating artificial intelligence and machine learning tools into industry necessitates large-scale collaborative efforts that ensure the robust and accurate execution of downstream analytics such as time series prediction, uncertainty quantification, grid optimization, and condition monitoring. However, concerns related to data privacy pervade the nuclear industry due to the proprietary nature of its data and the possibility of data leakage. Legacy techniques such as encryption often require the explicit transmission of data to trustworthy parties, thereby inviting data leakage concerns. The ideal collaboration scenario avoids the explicit dissemination of data/code while maintaining experimental fidelity, which is currently accomplished using various techniques such as trusted execution environments, homomorphic encryption, differential privacy, and multimatrix masking. These techniques, however, often necessitate a trade-off between trust, efficiency, and utility. This article extends a previously proposed technique called the directed infusion of data (DIOD) that ensures data privacy, allows for scalable obfuscation, and combats the risk of data leakage without compromising utility. The experiments discussed in this article examine a regression-type scenario using DIOD with the goal of preserving the inferential link between two variables. Using the point-kinetics equations, regression experiments compare the performance of a model trained using the original data to that of a model trained using the obfuscated data, which produced identical results. Our claim is further strengthened by an information theoretic proof and experiment, which showed that the inferential content between variables remains the same after obfuscation, thereby avoiding the required communication of the proprietary data.

47 - OTHER INSTRUMENTATION↗

Simulation of runaway electron production with CQL3D coupled to NIMROD

Abstract A coupling between two distinctly different codes—one magnetohydrodynamic (MHD) and another kinetic—is achieved and applied for simulation of runaway electron (RE) production. The 3D initial value MHD code NIMROD simulates a DIII-D pure neon shattered pellet injection plasma quench including the propagation and ablation of the fragments, ionization and recombination of the impurities, and the radiated and transported energies. The field data from NIMROD is then used by the bounce-averaged Fokker–Planck Collisional QuasiLinear 3D (CQL3D) kinetic code to simulate the production of REs and their radial transport. The coupling procedure involves mapping of data between different grids and adjustment of the NIMROD toroidal electric field when REs appear. It is shown that without the radial transport, a large RE current is generated, up to 30% of the pre-pellet ohmic current. However, when the radial transport is included in CQL3D, the RE current is reduced to undetectable level, consistent with experiment. Various forms of the radial diffusion are surveyed to determine conditions when the fast electrons would not have time to be accelerated to relativistic energies before they are lost to chamber wall.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Practical Start-Up Process of Multiple Grid-Tied Voltage-Sourced Inverters in Laboratory

Starting up inverter-based resources (IBRs) and integrating them into a grid are important in real-world engineering and there are many challenges to be tackled. Using a laboratory-scale hardware test bed (50 Watt and 20 V), this paper demonstrates the challenges and provides a practical start-up process that can smoothly energize two grid-tied voltage-sourced inverters (VSI) and synchronize the VSIs into a 60-Hz grid. The hardware test bed consists of two SiC VSIs and a 45-kW Chroma grid simulator to act as the grid. The inverter controls are implemented in OPAL-RT OP5600, which has the measurements sensed, control algorithms processed, and gate signals generated and sent to the VSI switches. This research focuses on examining how to energize VSIs and how to synchronize the VSIs into the grid. The best energizing approach is summarized based on comparison and analysis of the experiment results. The presented approach can prevent large transients during the start-up process.

Wang, Zhengyu↗

On the Use of Smart Meter Data to Estimate the Voltage Magnitude on the Primary Side of Distribution Service Transformers

This paper develops a novel method to estimate the voltage magnitude on the primary side of distribution service transformers. The proposed method relies exclusively on smart meters, and therefore it is fully data-driven. This is an important feature because electric utilities have detailed models of only the primary network - that is, the network between the distribution substation and the primary side of service transformers that are installed closer to end-customer sites. The network that connects the secondary side of service transformers to end-customer sites, referred to as the secondary network, is simply represented by a lumped load. For each secondary network, the proposed method uses data acquired from only 2 smart meters: the closest and the farthest-in the sense of electrical distance - from the service transformer. As a reference to this feature, the proposed method is named SM2Vp. To our knowledge, this is the first time a method is shown to provide actionable information for realtime operation and control of power distribution grids using only two smart meters per secondary network. This is important because utilities have experienced barriers in managing and using large data sets for real-time operation and control. SM2Vp is primarily intended to provide pseudo-measurements for distribution system state estimation, but it can also be used directly for voltage control schemes. The performance of SM2Vp is demonstrated by numerical simulations carried out on three secondary network synthetic models and by using field data provided by a utility partner serving customers in southwestern California. A maximum relative error of approximately 3.9% or less is observed for the primary voltage magnitude estimates in all numerical experiments.

distribution service transformer↗

Electrification Options for Multi-Family Water Heating in Cold Climates - Final Report

In multi-family buildings, large water storage tanks in centralized domestic hot water (DHW) systems can serve as thermal energy storage (TES) batteries to mitigate grid impact. These systems offer demand shift and efficiency benefits, significantly reducing peak power consumption, particularly in cold climates. This study evaluates the load-shifting benefits of a centralized heat pump water heater (HPWH) system equipped with a CO2 heat pump in multi-family buildings through simulation. The heat pump system and water storage tank are sized using design-day sizing. A finite-element-based stratified tank model and CO2 heat pump performance map from a commercial DHW product are used. Annual simulations are conducted to assess the benefits of the centralized DHW system for energy efficiency improvements, load shifting, and emission reductions. These simulations incorporate utility tariffs and marginal grid emission data from Los Angeles and Chicago. In Los Angeles, using a water tank as a thermal battery achieves 7.4% utility cost savings and 10.2% emission reduction. In Chicago, compared to HPWH conventional operation without preheating, TES-enabled central HPWH provides 15% utility cost savings and 13% emission reduction. The case study demonstrates that the demand reduction potential of central CO2 HPWHs is significant in cold climate regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scalability of Real-time Distribution Models

This work will focus on developing the capabilities and validating the models for a sub transmission network with multiple feeders and microgrids. To achieve this scale of Hardware-in-the-loop (HitL) simulation, it is necessary to federate and collaborate. The work aims to design the large-scale feeder models to allow federation with complementary testbeds in the future. The feeder would be designed to be reconfigurable to put the system into a variety of modes. Aggregators models will be included in each distribution network’s federate to take control actions and interact with the management systems. Lastly, the feeder model will support large scale resilience studies involving complex Distributed Energy Resources (DER) controls, microgrid studies and emulation of complex data flows in future grid architectures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reduced Models for Chemical Kinetics derived from Parallel Ensemble Simulations of Stirred Reactors

Detailed chemical kinetic models are essential to improve the predictive capability of computational fluid dynamics (CFD) simulations and to impact the development of next generation combustion technologies. However, such detailed kinetic models are beyond the reach of CFD codes due to the computational cost of transporting additional chemical degrees of freedom. Reduced order models for combustion kinetics exploit the presence of lower dimensional manifolds in the state space and require far fewer number of scalars to be transported as part of CFD simulations. In this paper, we describe the software infrastructure developed to allow large ensembles of stirred reactor configurations with detailed chemical kinetics. The canonical reactor simulations are incorporated in a workflow with sparse grid and data reduction methodologies aimed at development of reduced order models. We present results from analyzing the results of the stirred reactor calculations for syngas mixture using principal component analysis (PCA) and neural network methodologies. The results show that nonlinear autoencoder model can surpass PCA in representing the original dataset with far fewer degrees of freedom.

Zhang, Pei↗

On the Use of Smart Meter Data to Estimate the Voltage Magnitude on the Primary Side of Distribution Service Transformers: Preprint

This paper develops a novel method to estimate the voltage magnitude on the primary side of distribution service transformers. The proposed method relies exclusively on smart meters, and therefore it is fully data-driven. This is an important feature because electric utilities have detailed models of only the primary network--that is, the network between the distribution substation and the primary side of service transformers that are installed closer to end-customer sites. The network that connects the secondary side of service transformers to end-customer sites, referred to as the secondary network, is simply represented by a lumped load. For each secondary network, the proposed method uses data acquired from only 2 smart meters: the closest and the farthest--in the sense of electrical distance--from the service transformer. As a reference to this feature, the proposed method is named SM2Vp. To our knowledge, this is the first time a method is shown to provide actionable information for real-time operation and control of power distribution grids using only two smart meters per secondary network. This is important because utilities have experienced barriers in managing and using large data sets for real-time operation and control. SM2Vp is primarily intended to provide pseudo-measurements for distribution system state estimation, but it can also be used directly for voltage control schemes. The performance of SM2Vp is demonstrated by numerical simulations carried out on three secondary network synthetic models and by using field data provided by a utility partner serving customers in southwestern California. A maximum relative error of approximately 3.9% or less is observed for the primary voltage magnitude estimates in all numerical experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Model-Based Detection of Coordinated Attacks (DCA) in Distribution Systems

The fast-paced growth in digitization of smart grid components enhances system observability and remote-control capabilities through efficient communication. However, enhanced connectivity results in heightened system vulnerability towards cybersecurity risks in the cyber-physical power system. Coordinated cyber-attacks (CCA), when undetected, lead to system-wide impact in terms of large disturbances or widespread outages. Detecting CCA in the cyber layer is critical to thwart cyber-attacks in real-time before the attack impacts the physical system. The challenge of locating CCA stems from the complex grid dynamics, making it difficult to distinguish between normal operational variations and cyber-attack impact. CCA often employs multiple attack vectors targeting geographically distributed components, further complicating CCA identification. Existing research in intrusion detection is primarily focused on the transmission network and limited to detecting individual attacks. In this paper, a novel proactive DCA strategy is proposed for early detection of CCA by establishing correlations among distinct attack events through model-based reinforcement learning that utilizes abductive reasoning to conclude the attacker goal. The solution includes understanding the system model, learning the system dynamics, and correlating individual cyber-attacks to extract the attacker’s objective. The developed learning algorithm identifies the most probable attack path to reach the attacker’s objective by predicting the next attack steps. A DNP3-based cyber-physical co-simulation testbed is developed to test the proposed algorithm using the IEEE 13-node test feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A protocol and analysis of year-long simulations of global storm-resolving models and beyond

We propose a protocol to evaluate and analyze year-long simulations of global storm-resolving models (GSRMs). The proposed protocol complements an earlier 40-day simulation protocol under the DYAMOND (DYnamics of the Atmospheric general circulation Modeled On Non-hydrostatic Domains) project to allow the analysis of the seasonal cycle and associated climatic relevant phenomena. This intercomparison aims to reveal how GSRMs, which can simulate mesoscale convective systems (MCSs) in the global domain, reproduce atmospheric large-scale structures related to convection beyond month-long simulations. The intercomparison for one-year simulations is conducted by either atmosphere-only models or atmosphere–ocean coupled models with atmospheric horizontal mesh sizes less than 5 km. We recommend the continuous four seasons from March 2020 to February 2021 as a target period for the intercomparison but with options for many groups to join more flexibly. The output variables are collected at 0.25° resolution, and archives of a small set of native grid variables are encouraged to analyze tropical cyclones and MCSs. Through the proposed global storm-resolving simulation, we will evaluate the climatological distributions of the atmospheric large-scale circulations, such as the Intertropical Convergence Zone (ITCZ), monsoon, midlatitude jets, their time evolution, and the upscale impacts on them. We present sample analyses from a one-year simulation using the 3.5 km mesh Nonhydrostatic Icosahedral Atmospheric Model (NICAM), revealing the realistic zonal contrast of tropical precipitation, no double ITCZ structure, the reasonable midlatitude jet position and intensity but a weak bias of storm track activities, and a warm bias over the Eurasia during boreal winter. We also clarify the cross-scale interaction, such as the effects of cold pools on mean precipitation over the Maritime Continent through the precipitation diurnal cycle and the effects of resolved gravity waves on midlatitude mean flows. The proposed one-year simulation protocol is referred to as the “Sendai Protocol.” This protocol is not unique or definite for evaluating GSRMs; we prospect a hierarchical set of experiments from short-term to multi-year simulations as GSRM intercomparisons.

54 ENVIRONMENTAL SCIENCES↗

Commercial building HVAC demand flexibility with model predictive control: Field demonstration and literature insights

Model Predictive Control (MPC) for building Heating Ventilation and Air Conditioning (HVAC) systems is beginning to gain traction in the market, with a few controls companies incorporating it into their product offerings. However, it remains difficult to assess whether the energy cost savings are enough to justify the cost of MPC implementation for a particular building, given the limited number of reported demonstrations. For small commercial and residential buildings with relatively uniform systems, standardized approaches can help lower implementation costs. In contrast, for large buildings or district systems, the potential magnitude of cost savings could justify more customized solutions. Estimating the cost-effectiveness of MPC becomes more challenging for medium and large commercial buildings, where a one-size-fits-all solution may not be suitable, and the potential energy cost savings may be insufficient to justify a customized solution. To make MPC technology more appealing, incorporating additional value streams beyond energy efficiency alone can significantly increase its attractiveness. One such revenue stream is demand flexibility, in response to dynamic electricity prices, where MPC can leverage the thermal mass of the building to shift the load and support the grid. Building on an extensive literature review of MPC field studies focused on cost savings and demand flexibility, this paper presents the results of implementing MPC control in a large office building HVAC system in Berkeley, CA. Four different dynamic electricity price profiles were integrated into the MPC objective function to shift building demand while maintaining comfort, and field testing was performed with each price profile across four seasons. The results show potential for 40–65 % demand decrease percentage and up to 61 % annual cost savings compared to the existing rule-based control strategy, under the tested dynamic price scenarios. This paper also presents a sensitivity analysis on the cost savings with respect to the price profile variability, discusses the implementation effort for the price-responsive MPC, and compares the cost savings found in this study to those found in literature on the basis of dynamic price variability, or so-called Electricity Price Relative Standard Deviation.

Zanetti, Ettore↗