Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “kW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

A Novel Low-Profile High-Efficiency Three-Phase Matrix Transformer

High step-down isolated DC-DC conversion from an 800 V DC bus to low-voltage, high-current outputs is required in automotive auxiliary converters and data center power supplies. In such applications, conventional transformer-based converters require large turns ratios, which increase winding resistance, leakage inductance, and magnetic height. This paper proposes a novel low-profile three-phase matrix transformer that realizes a large effective voltage ratio through flux division among multiple secondary legs, without increasing the physical turns count of each winding. As a result, the proposed structure reduces copper usage and transformer height while preserving the voltage conversion capability of a conventional three-phase transformer. Finite element analysis shows that the proposed design reduces magnetic height by 27%, ferrite volume by 34%, and copper volume by 28%. Circuit-level simulations of an 800 V/12 V,3 kW CLLLC dual-active-bridge converter further show that the lower winding resistance reduces total system loss by 91% and increases DC-DC efficiency from 82.6% to 97.6% at 3 kW output.

Inoue, Shuntaro [ORNL] (ORCID:0000000262637627)↗

Design Optimization of Medium-Frequency Transformer for DAB Converters With DC Bias Capacity

Medium-frequency transformer (MFT) dc bias is critical for the safe operation of dual-active-bridge (DAB) converters. To analyze the dc bias, expressions of dc bias are derived for SiC MOSFET DAB converters. It shows that the dc bias is a current source in steady state; thus, a dc bias current capacity is defined and used as a design constraint in the optimization of MFT. The dc bias current capacity is related to core materials, geometric parameters, and flux density, which is analyzed with analytical expression. Optimization equations with geometric variables are derived, which can be solved theoretically or numerically for both interleaved winding (IW) and separated winding (SW) MFT without and/or with leakage inductance design. Based on the optimization equations, different MFT designs for a 150-kW SiC MOSFET DAB converter are compared on the aspects of core materials, winding structures, and without/with leakage inductance design. The combination of IW structure MFT with auxiliary phase shift inductors is chosen, and the assembled prototype is tested with the 150-kW DAB converter. Here, the designed dc bias capacity, temperature rise, and efficiency are verified.

42 ENGINEERING↗

System-Level Efficiency Study of Modular DC/DC and Fuel Cell Stack Series–Parallel Configurations

This paper presents a system-level efficiency study of modular DC/DC converter and fuel cell stack configurations under series, parallel, and series–parallel connections. The investigation considers selected DC/DC converter topologies, including isolated and non-isolated architectures, boost, non-inverting buck-boost, and resonant converters, integrated with commercially available fuel cell stacks, including the Accelera FCE150, Ballard FCgen-HPS, and Toyota TFCM2. DC/DC converter modules are evaluated in modular configurations rated at 60 kW and 90 kW and two distinct output voltage ranges, specifically 580–730V and 780–930V, examining how different interconnection schemes impact overall system efficiency. The converters are evaluated under full load (100%), partial load (66%), and light load (33%) conditions, providing a comprehensive assessment of efficiency and operational characteristics across varying power demands. Approximately two-thousand efficiency data points are obtained from laboratory prototype–level component measurements and validated design evaluations across multiple converter topologies, modular configurations, voltage ranges, and load conditions, providing a robust dataset for comparative system-level efficiency analysis. The results highlight the effects of modularity and topology selection on system-level efficiency, offering a “playbook” framework for designers to select appropriate DC/DC converter arrangements and fuel cell stack connections for series, parallel, or hybrid configurations based on efficiency considerations.

DC/DC↗

Advanced Design for the WIQ Magnet With Steering Corrector Function

The Facility for Rare Isotopes Beams (FRIB) delivers heavy-ion primary beams at energies of up to 300 MeV/u at 10 kW of beam power to generate rare isotope beams for experiments and will eventually operate at beam power of 400 kW. The preseprator of the Advanced Rare Isotope Separator (ARIS) is equipped with six warm-iron quadrupole (WIQ) singlets and two dipoles integrated right after the production target. They have a compact structure and operate in a high radiation vacuum environment within a hot cell having remote handling capabilities for installation and maintenance. Due to asymmetry with respect to the quadrupole poles, nested sextupole excitations in WIQs induce vertical dipoles that offset the centroid trajectory; Magnet misalignments also result in trajectory offsets. Such offsets degrade separator performance but can be minimized by changing the current distribution on sextupole and octupole coils. In this work, we show how modifications to the WIQ coil design can allow superimposed dipole fields to be included to the octupole and sextupole windings, as well as addition of dipole components by splitting coil currents over groups with separator power supplies. Adjusting the group currents can cancel the sextupole-induced vertical dipole component which can be as high as 0.012 Tm. Octupole coil changes may superimpose a horizontal dipole integrated strength as high as 0.0332 Tm. Unwanted higher harmonics induced as a side effect of the new design are kept to a minimum such that separator performance is preserved as much as possible.

Accelerator magnets↗

Solar PV and BESS Plant-Level Voltage Control and Interactions: Experiments and Analysis

In real world operation, low-frequency oscillations associated with plant-level voltage control of inverter-based resources (IBRs) have been a concern of grid operators. Here, this research aims to demonstrate and analyze the effect of plant-level voltage control on system stability and potential interactions among IBRs. The experiment results of a 13.2-kV system interconnected with two IBRs—a 1-MW battery energy storage system (BESS) and a 430-kW solar photovoltaic (PV) plant—are presented. Both 0.5-Hz and 3-Hz oscillations become visible at certain conditions. The phenomenon is further explained by use of a feedback system consisting of the plant-level droop control and the effect of reactive power or var injection on voltage. The main components of the block diagram are obtained via frequency scan measurements. The analysis offers an understanding of the main contributors and other influencing factors of the 3-Hz and 0.5-Hz modes. It also reveals the role of the volt-var droop gain, the low-pass filter time constant, and the system impedance in stability.

14 SOLAR ENERGY↗

Factors and Considerations for Modeling Loss of a GaN-based Inverter

The article investigates the impacts of four often-neglected factors on the loss model of a GaN-based full-bridge inverter: parasitic capacitance of the devices, dynamics of junction temperature (Tj) under time-varying power dissipation (Ploss), case temperature estimation, and detailed considerations of the passive components. Procedures to calculate the converter loss considering the above factors are proposed and implemented. A 4.5-kW hard-switching inverter prototype using gallium nitrite (GaN) high-electron-mobility transistors is used to experimentally demonstrate the impact of each factor on the converter loss model. Furthermore, it is found that the accuracy of a converter loss model is mainly affected by the passive components at the light load condition, whereas the thermal and loss models of the active components become the major factors as the output power increases. The results show that after considering the above factors, the converter loss discrepancy between calculation and measurement can be reduced from 30.6 W (28%) to 2.5 W (less than 3%) at heavy load (Po = 4.5 kW), while at the light load condition (Po = 500 W), it is reduced from 3.9 W (28%) to 2.6 W (16%). Furthermore, the difference between simulated and measured case temperature of the GaN devices is within 6 °C.

42 ENGINEERING↗

MPEX High Heat Flux Plasma Dump Design, Manufacture, and Articles Test

Here, the Material Plasma Exposure eXperiment (MPEX) device is a steady-state linear plasma device currently in the final design phase at the Oak Ridge National Laboratory. This device will reach ion fluences up to 10 31 m -2 and will be used to expose neutron-irradiated materials to divertor-relevant plasmas and to study the effects of plasma-material interactions. These studies will elucidate the complex effects of plasmas with divertor candidate materials capable of withstanding high heat flux and high fluences for next-generation fusion devices. Bidirectional plasma will be generated using a high-power (200 kW) helicon source. Plasma will be confined by superconducting magnets. The last plasma-facing component on the upstream side of the MPEX device is the dump, which has been designed to intercept plasma and energetic particles. The dump will have a total heat load of 9.2 kW. A copper alloy (Glidcop AL-15) was selected for use in the water-cooled flange design because of its high thermal conductivity, its retaining strength at elevated temperatures, and its ability to be used in the high-temperature braze joints used in this application. Titanium-zirconium-molybdenum (TZM) tiles are brazed to the Glidcop AL-15 flange using high-temperature braze alloy. External water-cooling channels are used on the dump flange to prevent water leakage inside the vacuum space. This article discusses the details of the high heat flux dump design, including the computational fluid dynamics (CFD) and structural analyses performed to validate the design to meet the operational requirements of the MPEX device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AMAROK: A Radio Frequency Development Platform for High-Power, Full-Scale Positive Ion Sources for DIII-D Neutral Beam Injectors

Next-generation neutral beam injection (NBI) systems demand RF ion sources capable of efficiently coupling >120 kW at 2–4-MHz frequencies, yet existing designs face voltage standoff and impedance-matching challenges. To address this, the advanced multicoil antenna for RF operations at kilowatts (AMAROK) was developed as a high-power RF inductively coupled plasma (ICP) source delivering up to 200 kW in the 2–4-MHz range via four phase-controlled generators for flexible power sharing. Two antenna designs—a single-strap multiturn (MT) and a multistrap single-turn (ST) design—were evaluated to optimize resonance, impedance matching, and power coupling across plasma loads. Here, a semi-analytical self-resonant frequency (SRF) model, validated experimentally, predicts resonance trends for arbitrary turn counts and tubing diameters, enabling rapid antenna optimization. Strap-to-strap mutual inductance in the ST configuration showed strong spatial dependence, guiding generator operation and total load inductance. These insights informed a custom π -topology matching network, achieving stable impedance matching over a wide range of plasma-driven loads. Collectively, these results position AMAROK as a versatile testbed for advancing high-power RF source technology in fusion NBI applications.

DIII-D↗

Diesel Generator Model Parameterization for Microgrid Simulation Using Hybrid Box-Constrained Levenberg-Marquardt Algorithm

Existing generator parameterization methods, typically developed for large turbine generator units, are difficult to apply to small kW-level diesel generators in microgrid applications. Here, this article presents a model parameterization method that estimates a complete set of kW-level diesel generator parameters simultaneously using only load-step-change tests with limited measurement points. This method provides a more cost-efficient and robust approach to achieve high-fidelity modeling of diesel generators for microgrid dynamic simulation. A two-stage hybrid box-constrained Levenberg-Marquardt (H-BCLM) algorithm is developed to search the optimal parameter set given the parameter bounds. A heuristic algorithm, namely Generalized Opposition-based Learning Genetic Algorithm (GOL-GA), is applied to identify proper initial estimates at the first stage, followed by a modified Levenberg-Marquardt algorithm designed to fine tune the solution based on the first-stage result. The proposed method is validated against dynamic simulation of a diesel generator model and field measurements from a 16kW diesel generator unit.

42 ENGINEERING↗

Self-Resonant Coil Design for High-frequency High-Power Inductive Wireless Power Transfer

In this paper, the design methodology of a high-frequency, high-power, long-distance inductive wireless power transfer (WPT) is presented. The airgap (d) of a traditional high-power (>1 kW) WPT is limited to a few hundred millimeters, which is almost 1/4th of the coil diameter, D; d ≤ D/4. In this paper, the power transfer distance is significantly increased (d ≥ 1.5D) by adopting a high-frequency magnetic design and GaN-based power electronics. The material and design of the coil and shield are investigated using FEA and tested experimentally. A high frequency 6.78 MHz wireless charging system was built to transfer 1 kW power over 3 m airgap.

Mohammad, Mostak↗

Interoperability between Three-Phase and Single-Phase WPT Systems

This paper presents an analysis and optimal position alignments of the transmitting and receiving couplers for achieving interoperability between a three-phase and a single-phase inductive wireless power transfer (WPT) system. In addition, single-phase operation modes for the six-switch three-phase inverter are identified for maximal power transfer from the three-phase transmitter pad to the single-phase receiver pad. Simulation results are included to show the power transfer capability between a 50 kW three-phase and an 11 kW double-D or circular single-phase WPT system at various alignment positions of the couplers.

Su, Gui-Jia↗

Design of a Combined Proportional Integral Derivative Controller to Regulate the Temperature Inside a High-Temperature Tubular Solar Reactor

Solar fuels are proven to be promising candidates for thermochemical energy storage. However, the transient nature of solar radiation is an obstacle to maintaining a stable operational temperature inside a solar reactor. To overcome this challenge, the temperature of a solar reactor can be regulated by controlling the incoming solar radiation or the feedstock flowrate inside the reactor. In this work, a combined proportional integral derivative (PID) controller is implemented to regulate the temperature inside a high-temperature tubular solar reactor with counter-current flowing gas/particles. The control model incorporates two control systems to regulate incoming solar radiation and gas flow simultaneously. The design of the controller is based on a reduced-order numerical model of a high-temperature tubular solar reactor that is vertically oriented with an upward gas flow and downward particle flow. The reactor receives heat circumferentially through its wall over a finite segment of its length. Formulation of the heat transfer model is presented by applying the energy balance for the reactor tube and considering heat and mass transfer inside. A set of governing differential equations are solved numerically by using the finite volume method to obtain reactor wall, particles, and gas temperatures along the reactor length with various boundary conditions. Simulation results are used to tune the PID controller parameters by utilizing the Ziegler–Nichols tuning method. Both the simulation results and the controller performance are visualized on the LABVIEW platform. The controller is challenged to track different temperature setpoints with different scenarios of transient solar radiation. Here, the performance of the PID controller was compared to experimental results obtained from an industrial PID controller embedded in a 7 kW electric furnace. Results show that the combined PID controller is successful in maintaining a stable temperature inside the reactor by regulating the incoming solar radiation and the flowrate via small steady-state error and reasonable settling time and overshoot.

14 SOLAR ENERGY↗

Enhancing Thermal Transport in Polymeric Composites Via Engineered Noncovalent Filler–Polymer Interactions

Understanding thermal transport mechanisms in polymeric composites allows us to expand the boundaries of thermal conductivity in them, either increasing it for more efficient heat dissipation or decreasing it for better thermal insulation. But, these mechanisms are not fully understood. Systematic experimental investigations remain limited. Practical strategies to tune the interfacial thermal resistance (ITR) between fillers and polymers and the thermal conductivity of composites remain elusive. Here, we studied the thermal transport in representative polymer composites, using polyethylene (PE) or polyaniline (PANI) as matrices and graphite as fillers. PANI, with aromatic rings in its backbone, interacts with graphite through strong noncovalent π–π stacking interactions, whereas PE lacks such interactions. We can then quantify how π–π stacking interactions between graphite and polymers enhance thermal transport in composites. PE/graphite and PANI/graphite composites with the same 1.5% filler volume fractions show a ∼22.82% and ∼34.85% enhancement in thermal conductivity compared to pure polymers, respectively. Calculated ITRs in PE/graphite and PANI/graphite are ~6 x 10 -8 m 2 KW -1 and ~1 x 10 -8 m 2 KW -1 , respectively, highlighting how π–π stacking interactions reduce ITR. Molecular dynamics (MD) simulations suggest that π–π stacking interactions between PANI chains and graphite surfaces enhance alignment of PANI's aromatic rings with graphite surfaces. This allows more carbon atoms from PANI chains to interact with graphite surfaces at a shorter distance compared to PE chains. Finally, our work indicates that tuning the π–π stacking interactions between polymers and fillers is an effective approach to reduce the ITR and enhance the thermal conductivity of composites.

atoms↗

Achieving 5,000-h and 8,000-h Low-PGM Electrode Durability on Automotive Drive Cycles

Whereas total Pt loading in anode and cathode catalysts below 0.125 mg cm −2 is required to meet the stringent cost target for automotive fuel cell systems (FCS) for light duty vehicles, low-loaded cathode catalysts are susceptible to unacceptable aging-related performance losses at high current densities. A framework model, validated by accelerated stress test data, has identified cell voltage, relative humidity (RH) and temperature as the key operating variables that affect degradation of a high-activity d-PtCo/C cathode catalyst with 0.1 mg cm −2 Pt loading. Drive cycle simulations indicate that these can be controlled by properly selecting the minimum FCS power, compressor-expander module (CEM) turndown, and stack coolant temperature. The optimum system parameters are 4-kW e minimum power for an 80-kW e FCS, CEM turndown of 12.5, and 66 °C average coolant exit temperature that combine to limit the maximum cell voltage to 850 mV and outlet RH to 90%–100%. Depending on Pt loading, the mismatch between actual and allowable degradation for 10% power loss over 5,000-h lifetime requires the stack to be oversized by 2.4%–5%, resulting in 8.4%–41% lower Pt utilization and 7.1%–20.5% penalty in stack cost. The corresponding results for 8,000-h lifetime are 10.3%-14% stack oversizing, 23%–51.8% lower Pt utilization, and 24.1%–35.4% stack cost penalty.

08 HYDROGEN↗

1.1 J Yb:YAG picosecond laser at 1 kHz repetition rate

We demonstrate the generation of 1.1 J pulses of picosecond duration at 1 kHz repetition rate (1.1 kW average power) from a diode-pumped chirped pulse amplification Yb:YAG laser. The laser employs cryogenically cooled amplifiers to generate λ <#comment/> = 1030 n m pulses with average power of up to 1.26 kW prior to compression with excellent beam quality. Pulses are compressed to 4.5 ps duration with 90% efficiency. This compact picosecond laser will enable a variety of applications that require high energy ultrashort pulses at kilohertz repetition rates.

Wang, Yong↗

TEAMER: FOSWEC Mooring Modeling and Analysis, Post Access Report and Data

Floating oscillating surge wave energy converters (FOSWECs) offer several advantages over bottom-hinged oscillating surge wave energy converters, including large wave potential at deep-water sites with fewer permitting and environmental concerns outside territorial waters. As a team, Stevens Institute of Technology, Virginia Tech and Resolute Marine Energy are designing a 100 kW FOSWEC with DOE support (2020-2021) for the PacWave test site "PacWave". The proposed FOSWEC consists of a floating platform, two pivoting flaps, and an innovative power-take-off (PTO). The distance between the two flaps is around half the typical wavelength, resulting in out-of-phase motion and a reduction in motion of the frame and mooring loads. The overall goal of the project is to design, build, deploy and analyze a 1:2 scale (100-kW annual averaged electrical power output) device with reduced levelized cost of energy (LCOE) and peak-to-average power ratio, through the co-design and control of the PTO, WEC, and floating platform. This submission includes a Post Access Report and data for the project of Mooring Modeling and Analysis for Floating Oscillating Surge Wave Energy Converter that Powers Marine Aquaculture of RFTS2 (request for technical support). The data are used to generate all figures in the Post Access Report. Project was a collaboration between Virginia Tech and the National Renewable Energy Lab, with funding from TEAMER.

16 TIDAL AND WAVE POWER↗

Files and scripts to support manuscript Shuman et al 2023 FATES-SPITFIRE ecosystem assembly across tropics

The dataset includes the parameter and domain files, relevant output files, and scripts to generate simulations and perform analysis with Jupyter notebooks that support the manuscript Shuman, JK et al 2023 “Dynamic ecosystem assembly and escaping the “fire-trap” in the tropics: Insights from FATES_15.0.0”. We have adapted the fire-behavior and effects module, SPITFIRE, for use with the Functionally Assembled Terrestrial Ecosystem Simulator (FATES), a size-structured vegetation demographic model. We test how climate, fire regime and fire-tolerance plant traits interact to determine the biogeography of tropical forests and grasslands. We assign different fire-tolerance strategies based on crown, leaf and bark characteristics, which are key observed fire-tolerance traits across woody plants. For these simulations, three types of vegetation compete for resources: a fire-vulnerable tree with thin bark, a vulnerable deep crown and fire-intolerant foliage; a fire-tolerant tree with thick bark, a thin crown and fire-tolerant foliage; and a fire-promoting C4 grass. We explore the model sensitivity to a critical parameter governing fuel moisture, and show that drier fuels promote increased burning, an expansion of area for grass and fire-tolerant trees and a reduction of area for fire-vulnerable trees. This conversion to lower biomass or grass areas with increased fuel drying results in increased fire burned area and its effects, which could fee back to local climate variables. Simulated size-based fire mortality for trees less than 20 cm in diameter and those with fire-vulnerable traits is higher than that for larger and/or fire-tolerant trees, in agreement with observations. Fire-disturbed forests demonstrate reasonable productivity and capture observed patterns of aboveground biomass in areas dominated by natural vegetation for the recent historical period, but have a large bias in less disturbed areas. Though the model predicts a greater extent of burned fraction than observed in areas with grass dominance, the resulting biogeography of fire-tolerant, thick-bark trees and fire-vulnerable, thin-bark trees corresponds to observations across the tropics. In areas with more than 2500 mm of precipitation, simulated fire frequency and burned area are low, with fire intensities below 150 kW m-1, consistent with observed understory fire behavior across the Amazon. Areas drier than this demonstrate fire intensities consistent with those measured in savannas and grasslands, with high values up to 4000 kW m-1. The results support a positive grass-fire feedback across the region, and suggest that forests which have existed without frequent burning may be vulnerable at higher fire intensities, which is of greater concern under intensifying climate and land use pressures. The ability of FATES to capture the connection between fire disturbance and plant fire-tolerance strategies in determining biogeography provides a useful tool for assessing the vulnerability and resilience of these critical carbon storage areas under changing conditions across the tropics.

54 ENVIRONMENTAL SCIENCES↗

Proton beam power limits for stationary water-cooled tungsten target with different cladding materials

The proton beam power limit for a solid-tungsten spallation target is largely determined by beam induced thermomechanical structural loads and decay heat power deposition, while its lifetime is limited by radiation damage and fatigue life of the target materials. In this paper, we studied the power limits of a stationary water-cooled solid tungsten target concept. Tantalum clad tungsten was considered as a reference case. Being a low activation material, zircaloy 2 cladding option was studied and its decay heat driven power limit was compared with the reference case. Zirconium alloys have proven operations records in spallation target and nuclear fission environments, supported by materials data obtained from post irradiation examinations. Recent study also demonstrated feasibility of diffusion bonding zirconium to tungsten using vanadium foil inter layer. Particle transport simulations code FLUKA was used to calculate energy deposition and decay heat power deposition in the target, based on the beam parameters technically feasible at the Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory. The energy deposition data were used for flow, thermal, and structural analyses to determine the beam intensity limit on the target concept studied. The decay heat deposition data were used to calculate the transient temperature evolution in the tungsten volumes in a loss of coolant accident (LOCA) scenario to determine its beam power limit. For a 1.3 GeV proton beam, the power limit on a stationary target was 400 kW for a tantalum clad target model and 800 kW for a zircaloy 2 clad target model.

Lee, Yong Joong↗