At least 793 records · Page 44

First VHF auroral radar interferometer observations

Auroral plasma instabilities were investigated using the radar interferometer technique based on observations obtained with a 49.92 MHz, 20-25 KW peak power pulsed radar located in Ithaca, NY (42.5 degrees N, 76.4 degrees W). Strong auroral echoes obtained during several highly active periods were analyzed. Phase differences between the signals received on the two antennas were utilized to accurately determine the E-W position, within the scattering volume, of localized scattering centers, and changes in this phase were used to determine the corresponding velocity. The radial (essentially N-S) motion was described by the signal Doppler shift. It is found that these data provide detailed information on the turbulent structure of the echoing region and show clearly that different features in the Doppler power spectrum often represent signals coming from different locations. It is concluded that these data can be utilized to determine full horizontal velocity vectors and hence the horizontal electric field, usually with a time resolution of the order of 15-30 s.

Providakes, J. F.↗

Interferometer Measures Broardband Surface Acoustic Waves

Dual differential interferometer uses two pairs of orthogonallypolarized optical beams to measure amplitude and orientation of broadband ultrasonic surface acoustic waves. Instrument modular, and sensitivity limited only by optical detector used.

Claus, R. O.↗

Interferometer for Measuring Acoustic Signals

Optical-fiber interferometer measures wave amplitude without contacting specimen surface. System contains remote detector head. Head includes beam splitter that divides input beam and recombines output beams, while spatial filter filters interference pattern at beam-splitter output; and lens focuses this on detector. Beams focused on specimen surface to record acoustic signals.

Claus, R. O.↗

Three component velocity measurements using Fabry-Perot interferometer

A method for measuring the three components of mean flow velocity using a backscatter optical system based on a confocal Fabry-Perot interferometer is described. An analysis of the expected uncertainties in the velocity component measurements is presented along with experimental data taken in a free jet at two flow velocities (100 and 300 m/s).

Seasholtz, R. G.↗

Image plane detector for the dynamics explorer Fabry-Perot interferometer

A compact twelve-channel photon-counting device based on existing Generation II imaging technology has been developed for use as the image-plane detector of the Dynamics Explorer Fabry-Perot interferometer. The device has an S-20 photocathode, three-microchannel plate electron multiplication stages, and an equal-area concentric-ring segmented anode whose geometry mimics that of the interference ring pattern produced by a plane etalon. The twelve channels sample equal and contiguous intervals in the spectrum. The purpose of the delopment has been to utilize the signal multiplex advantage of a multichannel detector in the measurement of Doppler shifts and line-broadening effects for naturally occurring atmospheric emission features of low intensity. The design, testing, calibration, and flight performance of the novel detector system are presented. In addition, measured emission line profiles at high resolution from the satellite instrument are presented to illustrate the operation of the device.

Killeen, T. L.↗

Doppler line profile analysis for a multichannel Fabry-Perot interferometer

A new method of instrument calibration and data analysis is presented for single-etalon interferometric measurements of winds, temperatures, and emission line intensities. The technique has been developed for the multichannel Fabry-Perot interferometer on the Dynamics Explorer spacecraft. A numerical representation of the instrumental transfer function is used based on a truncated Fourier series with empirically determined coefficients. The numerical form is compared with the conventional analytic form. The Fourier coefficients describing the instrument function are generated at the wavelength of a stable He-Ne laser and are translated to other wavelengths using an interpolation technique for both phase and power. A quasi-linear least-squares fitting process involving matrices provides for a rapid and accurate data reduction.

Killeen, T. L.↗

Two-beam interferometer for optical constants measurements at near-millimeter wavelengths

A simple and versatile instrument for the measurement of optical constants in the near millimeter spectral region is described. Studies of quasi-optical components used in this instrument for effective beam transmission and control are reported. These studies include transmission characteristics of dielectric waveguides and performance of a variable coupler based on frustrated total internal reflection. Operation of this instrument as a two-beam interferometer for determining the index of refraction or as a device to measure transmission for determining the absorption coefficient are described. Values measured with this instrument at 245 GHz, using an optically pumped molecular laser as the source, are reported for several low-loss materials. Appropriate corrections and error estimates are discussed. The potential for improvement and increased accuracies are discussed.

Jones, C. R.↗

Evaluation of a Magneto-optical Filter and a Fabry-perot Interferometer for the Measurement of Solar Velocity Fields from Space

A program was developed to evaluate the performance of three different devices as possible space-borne solar velocity field imagers. Two of these three devices, a magneto-optical filter and a molecular adherence Fabry-Perot interferometer were installed in a newly-constructed observing system located at the 60-foot tower telescope at the Mt. Wilson Observatory. Time series of solar filtergrams and Dopplergrams lasting up to 10 hours per day were obtained with the filter while shorter runs were obtained with the Fabry-Perot. Two-dimensional k (sub h)-omega power spectra which show clearly the well-known p-mode ridges were computed from the time series obtained with the magneto-optical filter. These power spectra were compared with similar power spectra obtained recently with the 13.7-m McMath spectrograph at Kitt Peak.

Rhodes, E. J., Jr.↗

Measurement of ultrasonic fields in transparent media using a scanning differential interferometer

An experimental system for the detection of three dimensional acoustic fields in optically transparent media using a dual beam differential interferometer is described. In this system, two coherent, parallel, focused laser beams are passed through the specimen and the interference fringe pattern which results when these beams are combined shifts linearly by an amount which is related to the optical pathlength difference between the two beams. It is shown that for small signals, the detector output is directly proportional to the amplitude of the acoustic field integrated along the optical beam path through the specimen. A water tank and motorized optical platform were constructed to allow these dual beams to be scanned through an ultrasonic field generated by a piezoelectric transducer at various distances from the transducer. Scan data for the near, Fresnel, and far zones of a uniform, circular transducer are presented and an algorithm for constructing the radial field profile from this integrated optical data, assuming cylindrical symmetry, is described.

Dockery, G. D.↗

Dual differential interferometer

A dual two-beam differential interferometer that measures both the amplitude and orientation of propagating, broadband surface acoustic waves is disclosed. Four beams are focused on a surface. The four reflected beams are separated into two pairs. The two pairs are detected to produce two signals that are used to compute amplitude and orientation.

Claus, R. O.↗

Multiple spacecraft Michelson stellar interferometer

Results of an orbital analysis and performance assessment of SAMSI (Spacecraft Array for Michelson Spatial Interferometry) are presented. The device considered includes two one-meter telescopes in orbits which are identical except for slightly different inclinations; the telescopes achieve separations as large as 10 km and relay starlight to a central station which has a one-meter optical delay line in one interferometer arm. It is shown that a 1000-km altitude, zero mean inclination orbit affords natural scanning of the 10-km baseline with departures from optical pathlength equality which are well within the corrective capacity of the optical delay line. Electric propulsion is completely adequate to provide the required spacecraft motions, principally those needed for repointing. Resolution of 0.00001 arcsec and magnitude limits of 15 to 20 are achievable.

Stachnik, R. V.↗

Plasma irregularities associated with a morning discrete auroral arc - Radar interferometer observations and theory

A description is given of E region auroral plasma irregularities associated with an intense auroral morning arc observed over Fort Churchill by radar. The observations are compared with data from an all-sky camera (ASC) operated at Fort Churchill by the National Research Council of Canada. The particular event described was chosen because of the rapid variation in structure and motion of the arc as it traveled through the radar beam. The horizontal vector electron drift velocity and electric field along the poleward boundary of the morning discrete auroral arc was successfully measured with a radar interferometer. This instrument provided information concerning the temporal and spatial structure of the electrostatic plasma turbulence in the arc. The observations are described.

Providakes, J.↗

SAMSI: An orbiting spatial interferometer for micro-arc second astronomical observations

The concept and performance of (SAMSI) Spacecraft Array for Michelson Spatial Interferometry, an orbiting spatial interferometer comprised of three free-flying spacecraft, two collector telescopes and a central mixing station are described. In the one-dimensional interferometry mode orbits exist which provide natural scanning of the baseline. These orbits place extremely small demands on thrusters and fuel consumption. Resolution of 0.00001 arcsecond and magnitude limits of mv = 15 to 20 are achievable in a single orbit. In the imaging mode, SAMSI could synthesize images equivalent to those produced by equal diameter filled apertures in space, making use of the fuel resupply capability of a space station. Simulations indicate that image reconstruction can be performed with milliarcsecond resolution to a visual magnitude 12 in 12 hr of spiral scanning integration time.

Stachnik, R. V.↗

Nondestructive ultrasonic measurement of bolt preload using the pulsed-phase locked-loop interferometer

Achieving accurate preload in threaded fasteners is an important and often critical problem which is encountered in nearly all sectors of government and industry. Conventional tensioning methods which rely on torque carry with them the disadvantage of requiring constant friction in the fastener in order to accurately correlate torque to preload. Since most of the applied torque typically overcomes friction rather than tensioning the fastener, small variations in friction can cause large variations in preload. An instrument called a pulsed phase locked loop interferometer, which was recently developed at NASA Langley, has found widespread use for measurement of stress as well as material properties. When used to measure bolt preload, this system detects changes in the fastener length and sound velocity which are independent of friction. The system is therefore capable of accurately establishing the correct change in bolt tension. This high resolution instrument has been used for precision measurement of preload in critical fasteners for numerous applications such as the space shuttle landing gear and helicopter main rotors.

Allison, S. G.↗

Improved Skin Friction Interferometer

An improved system for measuring aerodynamic skin friction which uses a dual-laser-beam oil-film interferometer was developed. Improvements in the optical hardware provided equal signal characteristics for each beam and reduced the cost and complexity of the system by replacing polarization rotation by a mirrored prism for separation of the two signals. An automated, objective, data-reduction procedure was implemented to eliminate tedious manual manipulation of the interferometry data records. The present system was intended for use in two-dimensional, incompressible flows over a smooth, level surface without pressure gradient, but the improvements discussed are not limited to this application.

Westphal, R. V.↗

A laser interferometer dilatometer for thermal expansion measurements of composites

A high precision Fizeau type, laser interferometer dilatometer system has been developed for low expansion composite materials. The strain resolution is about 1 microstrain. The system is automated to operate over a large temperature range and record data during the test in real time. A technique has been developed to reduce the fringe data in real time to length changes. The dilatometer system is described and thermal expansion measurements for several fiber-reinforced and particle filled composites are presented.

Tompkins, S. S.↗

Michelson interferometer with separated inputs and outputs, double pass, and compensation

A novel configuration is proposed for a Michelson interferometer spectrometer, which will be insensitive to tilts or displacements, and which employs separated inputs and outputs and double passing for higher resolution. The great advantage of such a compensated design is a relaxation of mechanical tolerances, which is especially beneficial for instruments in hostile environments. The Atmospheric Trace Molecule Spectroscopy project, which must work reliably after being subjected to the vibrations of a Space Shuttle launch, would benefit from the use of such an instrument.

Mather, J. C.↗

Three component velocity measurements using Fabry-Perot interferometer

A method for measuring the three components of mean flow velocity using a backscatter optical system based on a confocal Fabry-Perot interferometer is described. An analysis of the expected uncertainties in the velocity component measurements is presented along with experimental data taken in a free jet at two flow velocities (100 and 300 m/s).

Seasholtz, R. G.↗