Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

An Imaging Interferometer for Terrestrial Remote Sensing

A prototype imaging interferometer called DASI (digital array scanned interferometer) is under development at our laboratories. Our objective is to design an instrument for remote sensing of Earth's atmosphere and surface. This paper describes the unusual characteristics of DASIs which make them promising candidates for ground and aircraft-based terrestrial measurements. These characteristics include superior signal-to-noise, design simplicity and compactness, relative to dispersion based imaging spectrometers. Perhaps one of the most notable features of DASIs is their ability to acquire an entire interferogram simultaneously without any moving optical elements. We also describe selected laboratory and ground based field measurements using the prototype DASI. A CCD detector array was placed at the DASI detector plane for wavelength coverage from 0.4 to 1.0 micron. A NICMOS MCT detector was used for coverage from 1.1 to 2.2 micron. The DASI was configured to have a spectral resolution of about 300 1/cm, a spatial field of view of 5 degrees, and a constant number of transverse spatial elements (detector dependent) for each exposure frame. Frame exposure rates were up to 0.6 Hz with the potential to achieve 5 Hz. Image cube measurements of laboratory targets and terrestrial scenes were obtained by multiple frame scanning over the field of view. These data sets reveal the potential science yields from obtaining simultaneous high resolution spatial and spectral information.

Hammer, Philip D.↗

The Design of Optical Sensor for the Pinhole/Occulter Facility

Three optical sight sensor systems were designed, built and tested. Two optical lines of sight sensor system are capable of measuring the absolute pointing angle to the sun. The system is for use with the Pinhole/Occulter Facility (P/OF), a solar hard x ray experiment to be flown from Space Shuttle or Space Station. The sensor consists of a pinhole camera with two pairs of perpendicularly mounted linear photodiode arrays to detect the intensity distribution of the solar image produced by the pinhole, track and hold circuitry for data reduction, an analog to digital converter, and a microcomputer. The deflection of the image center is calculated from these data using an approximation for the solar image. A second system consists of a pinhole camera with a pair of perpendicularly mounted linear photodiode arrays, amplification circuitry, threshold detection circuitry, and a microcomputer board. The deflection of the image is calculated by knowing the position of each pixel of the photodiode array and merely counting the pixel numbers until threshold is surpassed. A third optical sensor system is capable of measuring the internal vibration of the P/OF between the mask and base. The system consists of a white light source, a mirror and a pair of perpendicularly mounted linear photodiode arrays to detect the intensity distribution of the solar image produced by the mirror, amplification circuitry, threshold detection circuitry, and a microcomputer board. The deflection of the image and hence the vibration of the structure is calculated by knowing the position of each pixel of the photodiode array and merely counting the pixel numbers until threshold is surpassed.

Greene, Michael E.↗

Airborne imaging spectrometer - A new tool for remote sensing

The first of a new class of remote sensing instruments is described. The Airborne Imaging Spectrometer represents the first use of two-dimensional integrated infrared area arrays in a scientific application. The instrument images 32 cross-track pixels simultaneously, each in 128 spectral bands in the 1.2- to 2.4-micron region. The IFOV of the instrument is 1.9 mrad/pixel and the spectral sampling interval is 9.6 nm. Plans include upgrading the detector from the current 32 x 32 element HgCdTe CCD array to a 64 x 64 element array in 1985. Science and engineering data are currently being actively gathered with the instrument.

Vane, G.↗

X-Ray Detector for 1 to 30 keV

Array of silicon X-ray detecting diodes measures photon energy and provides image of X-ray pattern. Regardless of thickness of new X-ray detector, depletion region extends through it. Impinging X-rays generate electrons in quantities proportional to X-ray energy. X-ray detector is mated to chargecoupled-device array for image generation and processing. Useful in industrial part inspection, pulsed-plasma research and medical application.

Alcorn, G.↗

Systems, computer-implemented methods, and tangible computer-readable storage media for wide-field interferometry

Disclosed herein are systems, computer-implemented methods, and tangible computer-readable storage media for wide field imaging interferometry. The method includes for each point in a two dimensional detector array over a field of view of an image: gathering a first interferogram from a first detector and a second interferogram from a second detector, modulating a path-length for a signal from an image associated with the first interferogram in the first detector, overlaying first data from the modulated first detector and second data from the second detector, and tracking the modulating at every point in a two dimensional detector array comprising the first detector and the second detector over a field of view for the image. The method then generates a wide-field data cube based on the overlaid first data and second data for each point. The method can generate an image from the wide-field data cube.

Lyon, Richard G.↗

Imaging spectrometer/camera having convex grating

An imaging spectrometer has fore-optics coupled to a spectral resolving system with an entrance slit extending in a first direction at an imaging location of the fore-optics for receiving the image, a convex diffraction grating for separating the image into a plurality of spectra of predetermined wavelength ranges; a spectrometer array for detecting the spectra; and at least one concave sperical mirror concentric with the diffraction grating for relaying the image from the entrance slit to the diffraction grating and from the diffraction grating to the spectrometer array. In one embodiment, the spectrometer is configured in a lateral mode in which the entrance slit and the spectrometer array are displaced laterally on opposite sides of the diffraction grating in a second direction substantially perpendicular to the first direction. In another embodiment, the spectrometer is combined with a polychromatic imaging camera array disposed adjacent said entrance slit for recording said image.

Reininger, Francis M.↗

The Southern Hemisphere VLBI experiment

Six radio telescopes were operated as the first Southern Hemisphere VLBI array in April and May 1982. Observations were made at 2.3 and 8.4 GHz. This array provided VLBI modeling and hybrid imaging of celestial radio sources in the Southern Hemisphere, high-accuracy VLBI geodesy between Southern Hemisphere sites, and subarcsecond radio astrometry of celestial sources south of declination -45 deg. The goals and implementation of the array are discussed, the methods of modeling and hybrid image production are explained, and the VLBI structure of the sources that were observed is summarized.

Preston, Robert A.↗

Continued Development of a Planetary Imaging Fourier Transform Spectrometer (PIFTS)

This report describes continued efforts to evaluate a breadboard of a Planetary Imaging Fourier Transform Spectrometer (PIFTS). The PIFTS breadboard was developed under prior PIDDP funding. That effort is described in the final report for NASA Grant NAG5-6248 and in two conference papers (Sromovsky et al. 2000; Revercomb et al. 2000). The PIFTS breadboard was designed for near-IR (1-5.2 micrometer imaging of planetary targets with spectral resolving powers of several hundred to several thousand, using an InSb detector array providing at least 64x64 pixels imaging detail. The major focus of the development effort was to combine existing technologies to produce a small and low power design compatible with a very low mass flyable instrument. The objective of this grant (NAG5-10729) was further characterization of the breadboard performance, including intercomparisons with the highly accurate non-imaging Advanced Emitted Radiance Interferometer (AERI) (Revercomb et al. 1994; Best et al. 1997).

Sromovsky, L. A.↗

Submillimeter and Far Infrared Experiment for SOFIA (SAFIRE): Progress and Prospects

SAFIRE/SOFIA is a versatile imaging Fabry-Perot spectrograph covering 100 less than lambda less than 655 microns, with spectral resolving power of approx. l0(exp 3). Selected as a "PI" instrument for the airborne Stratospheric Observatory for Infrared Astronomy (SOFIA), SAFIRE will apply two dimensional pop-up bolometer arrays to provide background limited imaging spectrometry. We describe the instrument design, its application to a range of astro- physical investigations, and current progress and results in the innovative detector and instrument design. SAFIRE/SOFIA is on track for availability in 2006.

Shafer, R. A.↗

Chip-integrated metasurface full-Stokes polarimetric imaging sensor

Abstract Polarimetric imaging has a wide range of applications for uncovering features invisible to human eyes and conventional imaging sensors. Chip-integrated, fast, cost-effective, and accurate full-Stokes polarimetric imaging sensors are highly desirable in many applications, which, however, remain elusive due to fundamental material limitations. Here we present a chip-integrated Meta surface-based Full-Stokes Polar imetric Im aging sensor (MetaPolarIm) realized by integrating an ultrathin (~600 nm) metasurface polarization filter array (MPFA) onto a visible imaging sensor with CMOS compatible fabrication processes. The MPFA is featured with broadband dielectric-metal hybrid chiral metasurfaces and double-layer nanograting polarizers. This chip-integrated polarimetric imaging sensor enables single-shot full-Stokes imaging (speed limited by the CMOS imager) with the most compact form factor, records high measurement accuracy, dual-color operation (green and red) and a field of view up to 40 degrees. MetaPolarIm holds great promise to enable transformative applications in autonomous vision, industry inspection, space exploration, medical imaging and diagnosis.

47 OTHER INSTRUMENTATION↗

Imaging by time-tagging photons with the multi-anode microchannel array detector system

The capability and initial use of the Multi-Anode Microchannel Array (MAMA) detector in the time-tag mode is reported. The detector hardware currently in use consists of a visible-light detector tube with a semitransparent photocathode proximity-focused to a high-gain curved-channel microchannel plate MCP. The photoevents are detected by a (256 x 1024)-pixel coincidence-anode array with pixel dimensions of 25 x 25 microns connected to charge-sensitive amplifiers and event-detection circuitry. In the time-lag mode, the detector delivers the pixel address and the time of arrival for each detected photon to an accuracy of 10 microns. The maximum count rate is limited by the speed of data-acquisition hardware. The MAMA detector in the time-lag mode is currently being evaluated in programs of astrometry and speckle imaging.

Timothy, J. G.↗

670-GHz Schottky Diode-Based Subharmonic Mixer with CPW Circuits and 70-GHz IF

GaAs-based, sub-harmonically pumped Schottky diode mixers offer a number of advantages for array implementation in a heterodyne receiver system. Since the radio frequency (RF) and local oscillator (LO) signals are far apart, system design becomes much simpler. A proprietary planar GaAs Schottky diode process was developed that results in very low parasitic anodes that have cutoff frequencies in the tens of terahertz. This technology enables robust implementation of monolithic mixer and frequency multiplier circuits well into the terahertz frequency range. Using optical and e-beam lithography, and conventional epitaxial layer design with innovative usage of GaAs membranes and metal beam leads, high-performance terahertz circuits can be designed with high fidelity. All of these mixers use metal waveguide structures for housing. Metal machined structures for RF and LO coupling hamper these mixers to be integrated in multi-pixel heterodyne array receivers for spectroscopic and imaging applications. Moreover, the recent developments of terahertz transistors on InP substrate provide an opportunity, for the first time, to have integrated amplifiers followed by Schottky diode mixers in a heterodyne receiver at these frequencies. Since the amplifiers are developed on a planar architecture to facilitate multi-pixel array implementation, it is quite important to find alternative architecture to waveguide-based mixers.

Chattopadhyay, Goutam↗

Mapping Pixel Windows To Vectors For Parallel Processing

Mapping performed by matrices of transistor switches. Arrays of transistor switches devised for use in forming simultaneous connections from square subarray (window) of n x n pixels within electronic imaging device containing np x np array of pixels to linear array of n(sup2) input terminals of electronic neural network or other parallel-processing circuit. Method helps to realize potential for rapidity in parallel processing for such applications as enhancement of images and recognition of patterns. In providing simultaneous connections, overcomes timing bottleneck or older multiplexing, serial-switching, and sample-and-hold methods.

Duong, Tuan A.↗

The imaging of extra-galactic low-energy gamma-ray sources prospects, techniques, and instrumentation

Improved understanding of the nature of active galaxies will require detailed observations of 10 to 20 sources, while understanding of their gamma ray luminosity function and its evolution will require the detection of approximately 100 sources. Instruments capable of detecting 100 active galaxies at low-energy, gamma ray energies are achievable. The angular resolution of an instrument, as well as its sensitivity, can limit the number of sources it can observe. An investigation of the angular resolution requirements for future low-energy gamma ray instruments is presented. It was found that the strictest requirements arise not from the need to resolve detectable sources, but from the need to control the level of direction-to-direction fluctuations in the diffuse background level. It was concluded that gamma-ray instruments capable of detecting 100 active galaxies must have sub-degree angular resolution. The use of the coded aperture imaging technique is proposed as a method of achieving accurate control of systematic errors and fine angular resolution without unduly increasing the time needed to conduct full sky surveys. An analysis of coded aperture imaging is presented for instruments that employ masks based on hexagonal uniformly redundant arrays. An instrument, the gamma-ray imaging payload, was built that employs these imaging techniques. The design and testing of the instrument is described in detail. Preliminary results from a balloon flight of the instruments are shown, demonstrating its imaging performance.

Finger, Mark Harold↗

A High Energy 2-microns Laser for Multiple Lidar Applications

Solid-state 2-microns laser has been receiving considerable interest because of its eye-safe property and efficient diode pump operation, It has potential for multiple lidar applications to detect water vapor. carbon dioxide and winds. In this paper, we describe a 2-microns double pulsed Ho:Tm:YLF laser and end-pumped amplifier system. A comprehensive theoretical model has been developed to aid the design and optimization of the laser performance. In a single Q-switched pulse operation the residual energy stored in the Tm atoms will be wasted. However, in a double pulses operation mode, the residual energy stored in the Tm atoms will repopulate the Ho atoms that were depleted by the extraction of the first Q-switched pulse. Thus. the Tin sensitized Ho:YLF laser provides a unique advantage in applications that require double pulse operation, such as Differential Absorption Lidar (DIAL). A total output energy of 146 mJ per pulse pair under Q-switch operation is achieved with as high as 4.8% optical to optical efficiency. Compared to a single pulse laser, 70% higher laser efficiency is realized. To obtain high energy while maintaining the high beam quality, a master-oscillator-power-amplifier 2-microns system is designed. We developed an end-pumped Ho:Tm:YLF disk amplifier. This amplifier uses two diode arrays as pump source. A non-imaging lens duct is used to couple the radiation from the laser diode arrays to the laser disk. Preliminary result shows that the efficiency of this laser can be as high as 3%, a factor of three increases over side-pump configuration. This high energy, highly efficient and high beam quality laser is a promising candidate for use in an efficient, multiple lidar applications.

Yu, Jirong↗

An Interferometry Imaging Beauty Contest

We present a formal comparison of the performance of algorithms used for synthesis imaging with optical/infrared long-baseline interferometers. Six different algorithms are evaluated based on their performance with simulated test data. Each set of test data is formated in the interferometry Data Exchange Standard and is designed to simulate a specific problem relevant to long-baseline imaging. The data are calibrated power spectra and bispectra measured with a ctitious array, intended to be typical of existing imaging interferometers. The strengths and limitations of each algorithm are discussed.

aperture synthesis↗

Flight Results from the HST SM4 Relative Navigation Sensor System

On May 11, 2009, Space Shuttle Atlantis roared off of Launch Pad 39A enroute to the Hubble Space Telescope (HST) to undertake its final servicing of HST, Servicing Mission 4. Onboard Atlantis was a small payload called the Relative Navigation Sensor experiment, which included three cameras of varying focal ranges, avionics to record images and estimate, in real time, the relative position and attitude (aka "pose") of the telescope during rendezvous and deploy. The avionics package, known as SpaceCube and developed at the Goddard Space Flight Center, performed image processing using field programmable gate arrays to accelerate this process, and in addition executed two different pose algorithms in parallel, the Goddard Natural Feature Image Recognition and the ULTOR Passive Pose and Position Engine (P3E) algorithms

Naasz, Bo↗

Digital and optical shape representation and pattern recognition; Proceedings of the Meeting, Orlando, FL, Apr. 4-6, 1988

The present conference discusses topics in pattern-recognition correlator architectures, digital stereo systems, geometric image transformations and their applications, topics in pattern recognition, filter algorithms, object detection and classification, shape representation techniques, and model-based object recognition methods. Attention is given to edge-enhancement preprocessing using liquid crystal TVs, massively-parallel optical data base management, three-dimensional sensing with polar exponential sensor arrays, the optical processing of imaging spectrometer data, hybrid associative memories and metric data models, the representation of shape primitives in neural networks, and the Monte Carlo estimation of moment invariants for pattern recognition.

Juday, Richard D.↗