Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imager”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Electron beam moiré fringes imaging by image converter tube with a magnetic lens

An image converter tube with a magnetic lens was used to obtain static images of moiré fringes formed by electron beam. These moiré fringes are formed due to the interference between the anode mesh and the photocathode containing slits of various spatial frequencies. Moiré fringes are observed at an accelerating voltage of 3.5 kV requiring the magnetic excitation condition of ∼550 ampere-turns. Not only the features of the fringes are analyzed but also the change of fringe spacing as a function of the rotation angle is investigated. The experimental results are found well in agreement with the theoretical analysis. By changing the rotation angle or adjusting the excitation condition of the magnetic lens, we were able to record parallel moiré and secondary moiré fringes too. The secondary moiré fringes can be observed in the rotation angle range of −39.5° to −50.6°. The theoretical analysis indicates that the secondary moiré is formed by the interference between the photocathode slits and the 2-D periodic structure of the anode mesh. Combining our proposed moiré method with the pulse-dilation technique may potentially open the door for future applications, in various fields including, but not limited to, ultrafast electrical pulse diagnostics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photovoltaic Module Imaging for Hail Damage Assessment with Multi-Year Follow Up

Outdoor-aged photovoltaic modules that have experienced golf-ball sized hail are characterized by flash testing and photoluminescence, electroluminescence, thermal, and ultraviolet fluorescence imaging. These measurements were performed immediately after the hailstorm and then again after another two years and four years in the field. The modules originally experienced different ranges of hail damage with some having cracks on approximately half of the cells and some having few to no cracked cells. Flash testing shows that the hail-damaged modules with the most cracked cells have 3 to 4% less power than those with the least damage. After four more years in the outdoor climate of Golden, Colorado since the hailstorm, all of the modules still exhibit similar relative power and amounts of cell cracking, suggesting that the hail damage has only initially reduced power but has not yet increased the degradation rate.

electroluminescence↗

Development of CCD Cameras for Soft X-ray Imaging at the National Ignition Facility

The Static X-Ray Imager (SXI) is a National Ignition Facility (NIF) diagnostic that uses a CCD camera to record time-integrated X-ray images of target features such as the laser entrance hole of hohlraums. SXI has two dedicated positioners on the NIF target chamber for viewing the target from above and below, and the X-ray energies of interest are 870 eV for the “soft” channel and 3 – 5 keV for the “hard” channels. The original cameras utilize a large format back-illuminated 2048 x 2048 CCD sensor with 24 micron pixels. Since the original sensor is no longer available, an effort was recently undertaken to build replacement cameras with suitable new sensors. Three of the new cameras use a commercially available front-illuminated CCD of similar size to the original, which has adequate sensitivity for the hard X-ray channels but not for the soft. For sensitivity below 1 keV, Lawrence Livermore National Laboratory (LLNL) had additional CCDs back-thinned and converted to back-illumination for use in the other two new cameras. In this paper we describe the characteristics of the new cameras and present performance data (quantum efficiency, flat field, and dynamic range) for the front- and back-illuminated cameras, with comparisons to the original cameras.

National Ignition Facility, X-ray diagnostic, X-ra↗

SU-E-P-33: Critical Role of T2-Weighted Imaging Combined with Diffusion-Weighted Imaging of MRI in Diagnosis of Loco-Regional Recurrent Esophageal Cancer After Radical Surgery

Purpose: We perform this study to investigate the diagnostic efficacy of T2-weighted MRI (T2WI) and diffusion-weighted MRI (DWI) in confirming local relapses of esophageal cancer in patients highly suspected of recurrence after eradicating surgery. Methods: Forty-two postoperative esophageal cancer patients with clinical suspicions of cancer recurrence underwent 3.0T MRI applying axial, coronal, sagittal T2WI and axial DWI sequences. Two experienced radiologists (R1 and R2) both used two methods (T2WI, T2WI+DWI) to observe the images, and graded the patients ranging from 1 to 5 to represent severity of the disease based on visual signal intensity (patients equal to or more than grade 3 was confirmed as recurrent disease) Results: 27/42patients were verified of recurrent disease by pathologic findings and/or imaging findings during follow-up. The sensitivity, specificity and accuracy of R1 applying T2WI+DWI are 96%, 87% and 93% versus 81%, 80% and 77% on T2WI, these figures by R2 were 96%, 93% and 95% versus 89%, 93% and 90%. The receiver operating curve (ROC) analyses suggest that both of the two readers can obtain better accuracy when adding DWI to T2WI compared with T2WI alone. Kappa test between R1 and R2 indicates excellent inter-observer agreement on T2WI+DWI. Conclusion: Standard T2WI in combination DWI can achieve better accuracy than T2WI alone in diagnosing local recurrence of esophageal cancer, and improve consistency between different readers.

60 APPLIED LIFE SCIENCES↗

Hyperspectral image reconstruction for x-ray fluorescence tomography

A penalized maximum-likelihood estimation is proposed to perform hyperspectral (spatio-spectral) image reconstruction for X-ray fluorescence tomography. The approach minimizes a Poisson-based negative log-likelihood of the observed photon counts, and uses a penalty term that has the effect of encouraging local continuity of model parameter estimates in both spatial and spectral dimensions simultaneously. The performance of the reconstruction method is demonstrated with experimental data acquired from a seed of arabidopsis thaliana collected at the 13-ID-E microprobe beamline at the Advanced Photon Source. The resulting element distribution estimates with the proposed approach show significantly better reconstruction quality than the conventional analytical inversion approaches, and allows for a high data compression factor which can reduce data acquisition times remarkably. In particular, this technique provides the capability to tomographically reconstruct full energy dispersive spectra without compromising reconstruction artifacts that impact the interpretation of results.

Fluorescence microscopy↗

SEARCHING FOR PLANET NINE WITH COADDED WISE AND NEOWISE-REACTIVATION IMAGES

A distant, as yet unseen ninth planet has been invoked to explain various observations of the outer solar system. While such a “Planet Nine,” if it exists, is most likely to be discovered via reflected light in the optical, it may emit much more strongly at 3−5 μm than simple blackbody predictions would suggest, depending on its atmospheric properties. As a result, Planet Nine may be detectable at 3.4 μm with the Wide-field Infrared Survey Explorer, but single exposures are too shallow except at relatively small distances (d{sub 9}≲430 au). We develop a method to search for Planet Nine far beyond the W1 single-exposure sensitivity, to distances as large as 800 au, using inertial coadds of W1 exposures binned into ∼1 day intervals. We apply our methodology to a ∼2000 square degree testbed sky region which overlaps a southern segment of Planet Nine’s anticipated orbital path. We do not detect a plausible Planet Nine candidate, but are able to derive a detailed completeness curve, ruling out its presence within the parameter space searched at W1 < 16.66 (90% completeness). Our method uses all publicly available W1 imaging, spanning 2010 January to 2015 December, and will become more sensitive with future NEOWISE-Reactivation releases of additional W1 exposures. We anticipate that our method will be applicable to the entire high Galactic latitude sky, and we will extend our search to that full footprint in the near future.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a Microchannel Plate-Based Gated X-ray Imager for Imaging and Spectroscopy Experiments on Z

This poster describes a microchannelplate (MCP)–based, gated x-ray imager developed by National Security Technologies, LLC (NSTec), and Sandia National Laboratories(SNL) over the past several years. The camera consists of a 40 mm × 40 mm MCP, coated with eight 4 mm wide microstrips. The camera is gated by sending subnanosecond high-voltage pulses across the striplines. We have performed an extensive characterization of the camera, the results of which we present here. The camera has an optical gate profile width (time resolution) as narrow as 150 ps and detector uniformity of better than 30% along the length of a strip, far superior than what was achieved in previous designs. The spatial resolution is on the order of 40 microns for imaging applications and a dynamic range of between ~100 and ~1000. We also present results from a Monte Carlo simulation code developed by NSTec over the last several years. Agreement between the simulation results and the experimental measurements is very good.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of near-field jet stability of a single-hole injector based on fast X-ray phase contrast imaging and image feature matching

Fuel spray is very effective in controlling the combustion process to improve engine performance and reduce emissions. Understanding the spray unstability during the injection process is of importance to improve the control of spray characteristics and engine operation. In this study, near-field biodiesel jets were recorded using fast X-ray phase contrast imaging and the flow features inside the jet were extracted using Speeded Up Robust Features (SURF) method. Here, the image similarity by feature matching was successfully used to represent the near-field jet stability. Based on the jet stability, an injection process can be divided into five stages: an unstable stage at needle opening, a partially stable transition stage at needle opening, a stable stage, a stable transition stage at needle closing and an unstable stage at needle closing. The ranges of needle lift for five stages were also determined. The jet unstability is highly related to the cavitation formation and gas purging process during needle opening. The variation of stable jet feature is dependent on the needle lift at needle closing. Higher needle lift for the similar jet feature at needle opening indicates a hydraulic delay compared to needle closing. Finally, the possible reasons of jet feature formation and feature detection used on the multi-hole injector are discussed.

33 ADVANCED PROPULSION SYSTEMS↗

Experimental study on the effect of nozzle hole-to-hole angle on the near-field spray of diesel injector using fast X-ray phase-contrast imaging

Fuel atomization and vaporization process play a critical role in determining the engine combustion and emission. The primary near-nozzle breakup is the vital link between the fuel emerging from the nozzle and the fully atomized spray. In this study, the near-nozzle spray characteristics of diesel injector with different umbrella angle (UA) were investigated using high-speed X-ray phase-contrast imaging and quantitative image processing. A classic ‘dumbbell’ profile of spray width (SW) composed of three stages: opening stage, semisteady stage and closing stage. The SW peak of two-hole injectors was more than twice of that of single-hole injector at the opening and closing stages, corresponding to the hollow-cone spray. This indicated the vortex flow was formed with the increase of the UA. The higher injection pressure had little influence on the SW while led to earlier breakup closer to the nozzle. Significant fuel effect on the SW at higher needle lift was found. However, this effect could be neglect at lower needle lift due to the leading role of internal flow and cavitation on the near-field spray characteristics. In addition, the morphology-based breakup process was observed, which highlighted the important effect of internal flow on the spray development. The possibility of using hollow-cone spray in diesel injector was also discussed.

biodiesel↗

Statistical detection of differentially abundant ions in mass spectrometry-based imaging experiments with complex designs

Mass Spectrometry Imaging (MSI) characterizes changes in chemical composition between regions of biological samples such as tissues. This translates into a statistical goal of class comparison, i.e. determining analytes that change in abundance between conditions more systematically than as expected by random variation. To reach accurate and reproducible conclusions, statistical analysis must appropriately reflect the initial research question, the design of the MSI experiment, and all the associated sources of variation. This manuscript highlights the importance of following these general statistical principles. Using the example of two case studies with complex experimental designs, and with dierent strategies of data acquisition, we demonstrate the extent to which choices made at key points of this workflow impact the results, and provide suggestions for appropriate design and analysis of MSI experiments that aim at detecting dierentially abundant analytes.

NanoDESI, mass spectrometry, MSIQuickView↗

Noninvasive Assessment of Tumor Microenvironment Using Dynamic Contrast-Enhanced Magnetic Resonance Imaging and {sup 18}F-Fluoromisonidazole Positron Emission Tomography Imaging in Neck Nodal Metastases

Purpose: To assess noninvasively the tumor microenvironment of neck nodal metastases in patients with head-and-neck cancer by investigating the relationship between tumor perfusion measured using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and hypoxia measured by {sup 18}F-fluoromisonidazole ({sup 18}F-FMISO) positron emission tomography (PET). Methods and Materials: Thirteen newly diagnosed head-and-neck cancer patients with metastatic neck nodes underwent DCE-MRI and {sup 18}F-FMISO PET imaging before chemotherapy and radiotherapy. The matched regions of interests from both modalities were analyzed. To examine the correlations between DCE-MRI parameters and standard uptake value (SUV) measurements from {sup 18}F-FMISO PET, the nonparametric Spearman correlation coefficient was calculated. Furthermore, DCE-MRI parameters were compared between nodes with {sup 18}F-FMISO uptake and nodes with no {sup 18}F-FMISO uptake using Mann-Whitney U tests. Results: For the 13 patients, a total of 18 nodes were analyzed. The nodal size strongly correlated with the {sup 18}F-FMISO SUV ({rho} = 0.74, p < 0.001). There was a strong negative correlation between the median k{sub ep} (redistribution rate constant) value ({rho} = -0.58, p = 0.042) and the {sup 18}F-FMISO SUV. Hypoxic nodes (moderate to severe {sup 18}F-FMISO uptake) had significantly lower median K{sup trans} (volume transfer constant) (p = 0.049) and median k{sub ep} (p = 0.027) values than did nonhypoxic nodes (no {sup 18}F-FMISO uptake). Conclusion: This initial evaluation of the preliminary results support the hypothesis that in metastatic neck lymph nodes, hypoxic nodes are poorly perfused (i.e., have significantly lower K{sup trans} and k{sub ep} values) compared with nonhypoxic nodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pathologic Validation of a Model Based on Diffusion-Weighted Imaging and Dynamic Contrast-Enhanced Magnetic Resonance Imaging for Tumor Delineation in the Prostate Peripheral Zone

Purpose: For focal boost strategies in the prostate, the robustness of magnetic resonance imaging-based tumor delineations needs to be improved. To this end we developed a statistical model that predicts tumor presence on a voxel level (2.5 Multiplication-Sign 2.5 Multiplication-Sign 2.5 mm3) inside the peripheral zone. Furthermore, we show how this model can be used to derive a valuable input for radiotherapy treatment planning. Methods and Materials: The model was created on 87 radiotherapy patients. For the validation of the voxelwise performance of the model, an independent group of 12 prostatectomy patients was used. After model validation, the model was stratified to create three different risk levels for tumor presence: gross tumor volume (GTV), high-risk clinical target volume (CTV), and low-risk CTV. Results: The model gave an area under the receiver operating characteristic curve of 0.70 for the prediction of tumor presence in the prostatectomy group. When the registration error between magnetic resonance images and pathologic delineation was taken into account, the area under the curve further improved to 0.89. We propose that model outcome values with a high positive predictive value can be used to define the GTV. Model outcome values with a high negative predictive value can be used to define low-risk CTV regions. The intermediate outcome values can be used to define a high-risk CTV. Conclusions: We developed a logistic regression with a high diagnostic performance for voxelwise prediction of tumor presence. The model output can be used to define different risk levels for tumor presence, which in turn could serve as an input for dose planning. In this way the robustness of tumor delineations for focal boost therapy can be greatly improved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Daily Orthogonal Kilovoltage Imaging Using a Gantry-Mounted On-Board Imaging System Results in a Reduction in Radiation Therapy Delivery Errors

Purpose: To determine whether the use of routine image guided radiation therapy (IGRT) using pretreatment on-board imaging (OBI) with orthogonal kilovoltage X-rays reduces treatment delivery errors. Methods and Materials: A retrospective review of documented treatment delivery errors from 2003 to 2009 was performed. Following implementation of IGRT in 2007, patients received daily OBI with orthogonal kV X-rays prior to treatment. The frequency of errors in the pre- and post-IGRT time frames was compared. Treatment errors (TEs) were classified as IGRT-preventable or non-IGRT-preventable. Results: A total of 71,260 treatment fractions were delivered to 2764 patients. A total of 135 (0.19%) TEs occurred in 39 (1.4%) patients (3.2% in 2003, 1.1% in 2004, 2.5% in 2005, 2% in 2006, 0.86% in 2007, 0.24% in 2008, and 0.22% in 2009). In 2007, the TE rate decreased by >50% and has remained low (P = .00007, compared to before 2007). Errors were classified as being potentially preventable with IGRT (e.g., incorrect site, patient, or isocenter) vs. not. No patients had any IGRT-preventable TEs from 2007 to 2009, whereas there were 9 from 2003 to 2006 (1 in 2003, 2 in 2004, 2 in 2005, and 4 in 2006; P = .0058) before the implementation of IGRT. Conclusions: IGRT implementation has a patient safety benefit with a significant reduction in treatment delivery errors. As such, we recommend the use of IGRT in routine practice to complement existing quality assurance measures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterizing the lipid and metabolite changes associated with placental function and pregnancy complications using ion mobility spectrometry-mass spectrometry and mass spectrometry imaging

Successful pregnancy is dependent upon discrete biological events, which include embryo implantation, decidualization, and placentation. Problems associated with each of these events can cause infertility or conditions such as preeclampsia. A greater understanding of the molecular changes associated with these complex processes is necessary to aid in identifying treatments for each condition. Previous nuclear magnetic resonance spectroscopy and mass spectrometry studies have been used to identify metabolites and lipids associated with pregnancy-related complications. However, due to limitations associated with conventional implementations of both techniques, novel technology developments are needed to more fully understand the initiation and development of pregnancy related problems at the molecular level. In this perspective, we describe current analytical techniques for metabolomic and lipidomic characterization of pregnancy complications and discuss the potential for new technologies such as ion mobility spectrometry-mass spectrometry and mass spectrometry imaging to contribute to a better understanding of the molecular changes that affect the placenta and pregnancy outcomes.

Environmental Molecular Sciences Laboratory↗