Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Refinement of Treatment Setup and Target Localization Accuracy Using Three-Dimensional Cone-Beam Computed Tomography for Stereotactic Body Radiotherapy

Purposes: To quantitatively compare two-dimensional (2D) orthogonal kV with three-dimensional (3D) cone-beam CT (CBCT) for target localization; and to assess intrafraction motion with kV images in patients undergoing stereotactic body radiotherapy (SBRT). Methods and Materials: A total of 50 patients with 58 lesions received 178 fractions of SBRT. After clinical setup using in-room lasers and skin/cradle marks placed at simulation, patients were imaged and repositioned according to orthogonal kV/MV registration of bony landmarks to digitally reconstructed radiographs from the planning CT. A subsequent CBCT was registered to the planning CT using soft tissue information, and the resultant 'residual error' was measured and corrected before treatment. Posttreatment 2D kV and/or 3D CBCT images were compared with pretreatment images to determine any intrafractional position changes. Absolute averages, statistical means, standard deviations, and root mean square (RMS) values of observed setup error were calculated. Results: After initial setup to external marks with laser guidance, 2D kV images revealed vector mean setup deviations of 0.67 cm (RMS). Cone-beam CT detected residual setup deviations of 0.41 cm (RMS). Posttreatment imaging demonstrated intrafractional variations of 0.15 cm (RMS). The individual shifts in three standard orthogonal planes showed no obvious directional biases. Conclusions: After localization based on superficial markings in patients undergoing SBRT, orthogonal kV imaging detects setup variations of approximately 3 to 4 mm in each direction. Cone-beam CT detects residual setup variations of approximately 2 to 3 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Four dimensional magnetic resonance imaging with retrospective k-space reordering: A feasibility study

Purpose: Current four dimensional magnetic resonance imaging (4D-MRI) techniques lack sufficient temporal/spatial resolution and consistent tumor contrast. To overcome these limitations, this study presents the development and initial evaluation of a new strategy for 4D-MRI which is based on retrospective k-space reordering. Methods: We simulated a k-space reordered 4D-MRI on a 4D digital extended cardiac-torso (XCAT) human phantom. A 2D echo planar imaging MRI sequence [frame rate (F) = 0.448 Hz; image resolution (R) = 256 × 256; number of k-space segments (N{sub KS}) = 4] with sequential image acquisition mode was assumed for the simulation. Image quality of the simulated “4D-MRI” acquired from the XCAT phantom was qualitatively evaluated, and tumor motion trajectories were compared to input signals. In particular, mean absolute amplitude differences (D) and cross correlation coefficients (CC) were calculated. Furthermore, to evaluate the data sufficient condition for the new 4D-MRI technique, a comprehensive simulation study was performed using 30 cancer patients’ respiratory profiles to study the relationships between data completeness (C{sub p}) and a number of impacting factors: the number of repeated scans (N{sub R}), number of slices (N{sub S}), number of respiratory phase bins (N{sub P}), N{sub KS}, F, R, and initial respiratory phase at image acquisition (P{sub 0}). As a proof-of-concept, we implemented the proposed k-space reordering 4D-MRI technique on a T2-weighted fast spin echo MR sequence and tested it on a healthy volunteer. Results: The simulated 4D-MRI acquired from the XCAT phantom matched closely to the original XCAT images. Tumor motion trajectories measured from the simulated 4D-MRI matched well with input signals (D = 0.83 and 0.83 mm, and CC = 0.998 and 0.992 in superior–inferior and anterior–posterior directions, respectively). The relationship between C{sub p} and N{sub R} was found best represented by an exponential function (C{sub P}=100(1−e{sup −0.18N{sub R}}), when N{sub S} = 30, N{sub P} = 6). At a C{sub P} value of 95%, the relative error in tumor volume was 0.66%, indicating that N{sub R} at a C{sub P} value of 95% (N{sub R,95%}) is sufficient. It was found that N{sub R,95%} is approximately linearly proportional to N{sub P} (r = 0.99), and nearly independent of all other factors. The 4D-MRI images of the healthy volunteer clearly demonstrated respiratory motion in the diaphragm region with minimal motion induced noise or aliasing. Conclusions: It is feasible to generate respiratory correlated 4D-MRI by retrospectively reordering k-space based on respiratory phase. This new technology may lead to the next generation 4D-MRI with high spatiotemporal resolution and optimal tumor contrast, holding great promises to improve the motion management in radiotherapy of mobile cancers.

60 APPLIED LIFE SCIENCES↗

WE-G-207-06: 3D Fluoroscopic Image Generation From Patient-Specific 4DCBCT-Based Motion Models Derived From Physical Phantom and Clinical Patient Images

Purpose: Respiratory-correlated cone-beam CT (4DCBCT) images acquired immediately prior to treatment have the potential to represent patient motion patterns and anatomy during treatment, including both intra- and inter-fractional changes. We develop a method to generate patient-specific motion models based on 4DCBCT images acquired with existing clinical equipment and used to generate time varying volumetric images (3D fluoroscopic images) representing motion during treatment delivery. Methods: Motion models are derived by deformably registering each 4DCBCT phase to a reference phase, and performing principal component analysis (PCA) on the resulting displacement vector fields. 3D fluoroscopic images are estimated by optimizing the resulting PCA coefficients iteratively through comparison of the cone-beam projections simulating kV treatment imaging and digitally reconstructed radiographs generated from the motion model. Patient and physical phantom datasets are used to evaluate the method in terms of tumor localization error compared to manually defined ground truth positions. Results: 4DCBCT-based motion models were derived and used to generate 3D fluoroscopic images at treatment time. For the patient datasets, the average tumor localization error and the 95th percentile were 1.57 and 3.13 respectively in subsets of four patient datasets. For the physical phantom datasets, the average tumor localization error and the 95th percentile were 1.14 and 2.78 respectively in two datasets. 4DCBCT motion models are shown to perform well in the context of generating 3D fluoroscopic images due to their ability to reproduce anatomical changes at treatment time. Conclusion: This study showed the feasibility of deriving 4DCBCT-based motion models and using them to generate 3D fluoroscopic images at treatment time in real clinical settings. 4DCBCT-based motion models were found to account for the 3D non-rigid motion of the patient anatomy during treatment and have the potential to localize tumor and other patient anatomical structures at treatment time even when inter-fractional changes occur. This project was supported, in part, through a Master Research Agreement with Varian Medical Systems, Inc., Palo Alto, CA. The project was also supported, in part, by Award Number R21CA156068 from the National Cancer Institute.

60 APPLIED LIFE SCIENCES↗

Granular Flow in Novel Octet Shape–Based Lattice Frame Material

Moving packed-bed heat exchangers in concentrated solar power (CSP) plants involves heat transfer between heated falling particles and supercritical carbon dioxide. The overall effective thermal conductivity of the moving packed bed and particle-side channel contact resistances are still the bottlenecks in achieving the desirable thermal transport levels. To this end, a novel moving packed bed heat exchanger consisting of an Octet lattice packed between the walls of the particle-side channel is proposed in this study. Granular flow analysis in Octet lattice moving packed bed heat exchanger (OLHX) was conducted through experiments and discrete element method (DEM)-based numerical simulations. The experimental images clearly demonstrated stagnation regions upstream of lattice fibers, void regions downstream of the fiber junctions, and wavy-type unobstructed flow on the lateral sides of the fibers. DEM simulations were successful in capturing all these critical flow phenomena. Larger flow velocities were observed on the lateral sides of the fibers in the simulations. Also, when the particles in the silo were emptied, the final images showed an accumulation of particles on the inter-fiber as well as fiber–channel wall junctions. Moreover, the fiber connections resulted in some regions devoid of particle contact on the channel endwall, which means that these regions would suffer from poor thermal exchange. Finally, the overall mass flowrate increased with increasing porosity for a fixed particle diameter.

14 SOLAR ENERGY↗

Fabrication of a Point-Like Transmission Target for Reducing Computed Tomography Imaging Artifacts

In this study, we address the challenge of enhancing image quality and spatial resolution in computed tomography (CT) imaging by introducing simulation and fabrication of high aspect ratio, point-like transmission targets. Utilizing advanced electroplating techniques, traditionally employed in the fabrication of Through Substrate Via (TSV) interconnects for CMOS circuitry, we successfully embed copper targets within silicon substrates. This method allows us to create high-aspect-ratio features specifically designed for X-ray transmission targets, resulting in micro targets that exhibit a volume increase compared to conventional evaporated surface targets. Furthermore, we present simulation results of the X-ray spectrum generated by these targets, demonstrating their potential to significantly improve both image quality and spatial resolution in CT applications. Our findings suggest that leveraging advanced fabrication techniques can open new avenues for the development of enhanced imaging technologies in medical diagnostics and beyond.

47 OTHER INSTRUMENTATION↗

SU-E-J-45: The Correlation Between CBCT Flat Panel Misalignment and 3D Image Guidance Accuracy

Purpose To simulate the impact of CBCT flat panel misalignment on the image quality, the calculated correction vectors in 3D image guided proton therapy and to determine if these calibration errors can be caught in our QA process. Methods The X-ray source and detector geometrical calibration (flexmap) file of the CBCT system in the AdaPTinsight software (IBA proton therapy) was edited to induce known changes in the rotational and translational calibrations of the imaging panel. Translations of up to ±10 mm in the x, y and z directions (see supplemental) and rotational errors of up to ±3° were induced. The calibration files were then used to reconstruct the CBCT image of a pancreatic patient and CatPhan phantom. Correction vectors were calculated for the patient using the software’s auto match system and compared to baseline values. The CatPhan CBCT images were used for quantitative evaluation of image quality for each type of induced error. Results Translations of 1 to 3 mm in the x and y calibration resulted in corresponding correction vector errors of equal magnitude. Similar 10mm shifts were seen in the y-direction; however, in the x-direction, the image quality was too degraded for a match. These translational errors can be identified through differences in isocenter from orthogonal kV images taken during routine QA. Errors in the z-direction had no effect on the correction vector and image quality.Rotations of the imaging panel calibration resulted in corresponding correction vector rotations of the patient images. These rotations also resulted in degraded image quality which can be identified through quantitative image quality metrics. Conclusion Misalignment of CBCT geometry can lead to incorrect translational and rotational patient correction vectors. These errors can be identified through QA of the imaging isocenter as compared to orthogonal images combined with monitoring of CBCT image quality.

60 APPLIED LIFE SCIENCES↗

A Scintillation-Fiber Based Cosmic-ray Muon Tomography System for Imaging Dry Storage Cask

Because of the growth of the nuclear power industry in the United States and the policy decision to ban reprocessing of commercial spent nuclear fuel, the spent fuel inventory at commercial reactor sites has been increasing. Spent nuclear fuel presents extra complexity of security and proliferation issues. These fuel assemblies are practically inaccessible for inspection purposes, as reopening a DSC would require special facilities and would be tremendously expensive. Cosmic-ray muon Tomography has been studied in the past for various applications and was demonstrated to be a good non-destructive assay technique for high-Z materials, such as spent nuclear fuel assemblies in dry storage casks (DSC). Compared to conventional imaging techniques, muon imaging has some advantages due to its negligible health risk and high penetrating power. In this paper, we report our simulation study on imaging a DSC using muon Tomography technique. The Point of Closest Approach (POCA) and the Maximum-Likelihood Expectation- Maximization (ML-EM) algorithms are implemented and evaluated. A scaled-down prototype muon tomography system is proposed and studied. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-J-204: Carbon Digitally Reconstructed Radiography (CDRR): A GPU Based Tool for Fast and Versatile Carbonimaging Simulation

Purpose: Research in carbon imaging has been growing over the past years, as a way to increase treatment accuracy and patient positioning in carbon therapy. The purpose of this tool is to allow a fast and flexible way to generate CDRR data without the need to use Monte Carlo (MC) simulations. It can also be used to predict future clinically measured data. Methods: A python interface has been developed, which uses information from CT or 4DCT and thetreatment calibration curve to compute the Water Equivalent Path Length (WEPL) of carbon ions. A GPU based ray tracing algorithm computes the WEPL of each individual carbon traveling through the CT voxels. A multiple peak detection method to estimate high contrast margin positioning has been implemented (described elsewhere). MC simulations have been used to simulate carbons depth dose curves in order to simulate the response of a range detector. Results: The tool allows the upload of CT or 4DCT images. The user has the possibility to selectphase/slice of interested as well as position, angle…). The WEPL is represented as a range detector which can be used to assess range dilution and multiple peak detection effects. The tool also provides knowledge of the minimum energy that should be considered for imaging purposes. The multiple peak detection method has been used in a lung tumor case, showing an accuracy of 1mm in determine the exact interface position. Conclusion: The tool offers an easy and fast way to simulate carbon imaging data. It can be used for educational and for clinical purposes, allowing the user to test beam energies and angles before real acquisition. An analysis add-on is being developed, where the used will have the opportunity to select different reconstruction methods and detector types (range or energy). Fundacao para a Ciencia e a Tecnologia (FCT), PhD Grant number SFRH/BD/85749/2012.

60 APPLIED LIFE SCIENCES↗

Imaging Performance Analysis of Simbol-X with Simulations

Simbol-X is an X-Ray telescope operating in formation flight. It means that its optical performances will strongly depend on the drift of the two spacecrafts and its ability to measure these drifts for image reconstruction. We built a dynamical ray tracing code to study the impact of these parameters on the optical performance of Simbol-X (see Chauvin et al., these proceedings). Using the simulation tool we have developed, we have conducted detailed analyses of the impact of different parameters on the imaging performance of the Simbol-X telescope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Population-level Dark Energy Constraints from Strong Gravitational Lensing using Simulation-Based Inference

In this work, we present a scalable approach for inferring the dark energy equation-of-state parameter ($w$) from a population of strong gravitational lens images using Simulation-Based Inference (SBI). Strong gravitational lensing offers crucial insights into cosmology, but traditional Monte Carlo methods for cosmological inference are computationally prohibitive and inadequate for processing the thousands of lenses anticipated from future cosmic surveys. New tools for inference, such as SBI using Neural Ratio Estimation (NRE), address this challenge effectively. By training a machine learning model on simulated data of strong lenses, we can learn the likelihood-to-evidence ratio for robust inference. Our scalable approach enables more constrained population-level inference of $w$ compared to individual lens analysis, constraining $w$ to within $1\sigma$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Population-level Dark Energy Constraints from Strong Gravitational Lensing using Simulation-Based Inference

In this work, we present a scalable approach for inferring the dark energy equation-of-state parameter ($w$) from a population of strong gravitational lens images using Simulation-Based Inference (SBI). Strong gravitational lensing offers crucial insights into cosmology, but traditional Monte Carlo methods for cosmological inference are computationally prohibitive and inadequate for processing the thousands of lenses anticipated from future cosmic surveys. New tools for inference, such as SBI using Neural Ratio Estimation (NRE), address this challenge effectively. By training a machine learning model on simulated data of strong lenses, we can learn the likelihood-to-evidence ratio for robust inference. Our scalable approach enables more constrained population-level inference of $w$ compared to individual lens analysis, constraining $w$ to within $1\sigma$. Our model can be used to provide cosmological constraints from forthcoming strong lens surveys, such as the 4MOST Strong Lensing Spectroscopic Legacy Survey (4SLSLS), which is expected to observe 10,000 strong lenses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Population-level Dark Energy Constraints from Strong Gravitational Lensing using Simulation-Based Inference

In this work, we present a scalable approach for inferring the dark energy equation-of-state parameter ($w$) from a population of strong gravitational lens images using Simulation-Based Inference (SBI). Strong gravitational lensing offers crucial insights into cosmology, but traditional Monte Carlo methods for cosmological inference are computationally prohibitive and inadequate for processing the thousands of lenses anticipated from future cosmic surveys. New tools for inference, such as SBI using Neural Ratio Estimation (NRE), address this challenge effectively. By training a machine learning model on simulated data of strong lenses, we can learn the likelihood-to-evidence ratio for robust inference. Our scalable approach enables more constrained population-level inference of $w$ compared to individual lens analysis, constraining $w$ to within 1$\sigma$. Our model can be used to provide cosmological constraints from forthcoming strong lens surveys, such as the 4MOST Strong Lensing Spectroscopic Legacy Survey (4SLSLS), which is expected to observe 10,000 strong lenses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Resolution recovery for Compton camera using origin ensemble algorithm

Purpose: Compton cameras (CCs) use electronic collimation to reconstruct the images of activity distribution. Although this approach can greatly improve imaging efficiency, due to complex geometry of the CC principle, image reconstruction with the standard iterative algorithms, such as ordered subset expectation maximization (OSEM), can be very time-consuming, even more so if resolution recovery (RR) is implemented. We have previously shown that the origin ensemble (OE) algorithm can be used for the reconstruction of the CC data. Here we propose a method of extending our OE algorithm to include RR. Methods: To validate the proposed algorithm we used Monte Carlo simulations of a CC composed of multiple layers of pixelated CZT detectors and designed for imaging small animals. A series of CC acquisitions of small hot spheres and the Derenzo phantom placed in air were simulated. Images obtained from (a) the exact data, (b) blurred data but reconstructed without resolution recovery, and (c) blurred and reconstructed with resolution recovery were compared. Furthermore, the reconstructed contrast-to-background ratios were investigated using the phantom with nine spheres placed in a hot background. Results: Our simulations demonstrate that the proposed method allows for the recovery of the resolution loss that is due to imperfect accuracy of event detection. Additionally, tests of camera sensitivity corresponding to different detector configurations demonstrate that the proposed CC design has sensitivity comparable to PET. When the same number of events were considered, the computation time per iteration increased only by a factor of 2 when OE reconstruction with the resolution recovery correction was performed relative to the original OE algorithm. We estimate that the addition of resolution recovery to the OSEM would increase reconstruction times by 2–3 orders of magnitude per iteration. Conclusions: The results of our tests demonstrate the improvement of image resolution provided by the OE reconstructions with resolution recovery. The quality of images and their contrast are similar to those obtained from the OE reconstructions from scans simulated with perfect energy and spatial resolutions.

60 APPLIED LIFE SCIENCES↗

MO-G-17A-02: Computer Simulation Studies for On-Board Functional and Molecular Imaging of the Prostate Using a Robotic Multi-Pinhole SPECT System

Purpose: To investigate prostate imaging onboard radiation therapy machines using a novel robotic, 49-pinhole Single Photon Emission Computed Tomography (SPECT) system. Methods: Computer-simulation studies were performed for region-of-interest (ROI) imaging using a 49-pinhole SPECT collimator and for broad cross-section imaging using a parallel-hole SPECT collimator. A male XCAT phantom was computersimulated in supine position with one 12mm-diameter tumor added in the prostate. A treatment couch was added to the phantom. Four-minute detector trajectories for imaging a 7cm-diameter-sphere ROI encompassing the tumor were investigated with different parameters, including pinhole focal length, pinhole diameter and trajectory starting angle. Pseudo-random Poisson noise was included in the simulated projection data, and SPECT images were reconstructed by OSEM with 4 subsets and up to 10 iterations. Images were evaluated by visual inspection, profiles, and Root-Mean- Square-Error (RMSE). Results: The tumor was well visualized above background by the 49-pinhole SPECT system with different pinhole parameters while it was not visible with parallel-hole SPECT imaging. Minimum RMSEs were 0.30 for 49-pinhole imaging and 0.41 for parallelhole imaging. For parallel-hole imaging, the detector trajectory from rightto- left yielded slightly lower RMSEs than that from posterior to anterior. For 49-pinhole imaging, near-minimum RMSEs were maintained over a broader range of OSEM iterations with a 5mm pinhole diameter and 21cm focal length versus a 2mm diameter pinhole and 18cm focal length. The detector with 21cm pinhole focal length had the shortest rotation radius averaged over the trajectory. Conclusion: On-board functional and molecular prostate imaging may be feasible in 4-minute scan times by robotic SPECT. A 49-pinhole SPECT system could improve such imaging as compared to broadcross-section parallel-hole collimated SPECT imaging. Multi-pinhole imaging can be improved by considering pinhole focal length, pinhole diameter, and trajectory starting angle. The project is supported by the NIH grant 5R21-CA156390.

60 APPLIED LIFE SCIENCES↗

Information-Theoretic Exploration of Multivariate Time-Varying Image Databases

Modern scientific simulations produce very large datasets, making interactive exploration of such data computationally prohibitive. An increasingly common data reduction technique is to store visualizations and other data extracts in a database. The Cinema project is one such approach, storing visualizations in an image database for post hoc exploration and interactive image-based analysis. This work focuses on developing efficient algorithms that can quantify various types of multivariate dependencies existing within multi-variable datasets. It applies specific mutual information measures for the quantification of salient regions from multivariate image data. Here, using such information measures, the opacity of the images is modulated so that the salient regions are automatically highlighted and the domain scientists can interactively explore the most relevant regions for scientific discovery.

97 MATHEMATICS AND COMPUTING↗

Three-dimensional model of intracellular and intercellular Ca2+ waves propagation in endothelial cells

Highlights: • Image-based 3D simulation model for intercellular and intracellular Ca{sup 2+} waves. • Metabolic reactions were divided into membrane and cytoplasm domains. • Ca{sup 2+} and IP{sub 3} diffused across the cell and gap junctions. • Ca{sup 2+} waves are propagated from focal stimulated point in numerical simulation. • Ca{sup 2+} wave speed was in agreement with those from cell culture experiments. Intracellular and intercellular Ca{sup 2+} waves play key roles in cellular functions, and focal stimulation triggers Ca{sup 2+} wave propagation from stimulation points to neighboring cells, involving localized metabolism reactions and specific diffusion processes. Among these, inositol 1,4,5-trisphosphate (IP{sub 3}) is produced at membranes and diffuses into the cytoplasm to release Ca{sup 2+} from endoplasmic reticulum (ER). In this study, we developed a three-dimensional (3D) simulation model for intercellular and intracellular Ca{sup 2+} waves in endothelial cells (ECs). 3D model of 2 cells was reconstructed from confocal microscopic images and was connected via gap junctions. Cells have membrane and cytoplasm domains, and metabolic reactions were divided into each domain. Finally, the intracellular and intercellular Ca{sup 2+} wave propagations were induced using microscopic stimulation and were compared between numerical simulations and experiments. The experiments showed that initial sharp increases in intracellular Ca{sup 2+} occurred approximately 0.3 s after application of stimuli. In addition, Ca{sup 2+} wave speeds remained constant in cells, with intracellular and intercellular speeds of approximately 35 and 15 μm/s, respectively. Simulations indicated initial increases in Ca{sup 2+} concentrations at points of stimulation, and these were then propagated across stimulated and neighboring cells. In particular, initial rapid increases in intracellular Ca{sup 2+} were delayed and subsequent intracellular and intercellular Ca{sup 2+} wave speeds were approximately 25 and 12 μm/s, respectively. Simulation results were in agreement with those from cell culture experiments, indicating the utility of our 3D model for investigations of intracellular and intercellular messaging in ECs.

60 APPLIED LIFE SCIENCES↗