Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image charge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Numerical computations and optical diagnostics of unsteady partially premixed methane/air flames

The structures and dynamics of unsteady laminar partially premixed methane/air Bunsen flames are studied by means of numerical simulations, OH and CH PLIF imaging, and high speed chemiluminescence imaging employing a high framing speed intensified charge coupled device camera. The Bunsen burner has a diameter of 22 mm. Rich methane/air mixtures with an equivalence ratio of 1.5 are injected from the burner into atmosphere at different flow speeds ranging from 0.77 to 1.7 m/s, with Reynolds numbers based on the nozzle flow ranging from 1100 to 2500. The numerical simulations are based on a two-scalar flamelet manifold tabulation approach. Detailed chemistry is used to generate the flamelet manifold tabulation which relates the species concentrations, reaction rates, temperature and density to a distance function G and mixture fraction Z. Two distinct reaction zones are identified using CH and OH PLIF imaging and numerical simulations; one inner reaction zone corresponds to premixed flames on the rich side of the mixture and one outer reaction zone corresponds to mixing controlled diffusion flames on the lean side of the mixture. Under normal gravity conditions both the inner premixed flames and the outer diffusion flames are unsteady. The outer diffusion flames oscillate with a flickering frequency of about 15 Hz, which slightly increases with the burner exit velocity. The inner premixed flames are more random with much more small-scale wrinkling structures. Under zero gravity conditions the outer diffusion flames are stable whereas the inner premixed flames are unstable and highly wrinkled. It appears that the outer diffusion flames are governed by the Rayleigh-Taylor instability whereas the inner premixed flames are dictated by Landau-Darrieus instability. The two-scalar flamelet approach is shown to capture the basic structures and dynamics of the investigated unsteady partially premixed flames. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bacterial Immobilization for Imaging by Atomic Force Microscopy

AFM is a high-resolution (nm scale) imaging tool that mechanically probes a surface. It has the ability to image cells and biomolecules, in a liquid environment, without the need to chemically treat the sample. In order to accomplish this goal, the sample must sufficiently adhere to the mounting surface to prevent removal by forces exerted by the scanning AFM cantilever tip. In many instances, successful imaging depends on immobilization of the sample to the mounting surface. Optimally, immobilization should be minimally invasive to the sample such that metabolic processes and functional attributes are not compromised. By coating freshly cleaved mica surfaces with porcine (pig) gelatin, negatively charged bacteria can be immobilized on the surface and imaged in liquid by AFM. Immobilization of bacterial cells on gelatin-coated mica is most likely due to electrostatic interaction between the negatively charged bacteria and the positively charged gelatin. Several factors can interfere with bacterial immobilization, including chemical constituents of the liquid in which the bacteria are suspended, the incubation time of the bacteria on the gelatin coated mica, surface characteristics of the bacterial strain and the medium in which the bacteria are imaged. Overall, the use of gelatin-coated mica is found to be generally applicable for imaging microbial cells.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

CMOS Imager Has Better Cross-Talk and Full-Well Performance

A complementary metal oxide/semiconductor (CMOS) image detector now undergoing development is designed to exhibit less cross-talk and greater full-well capacity than do prior CMOS image detectors of the same type. Imagers of the type in question are designed to operate from low-voltage power supplies and are fabricated by processes that yield device features having dimensions in the deep submicron range. Because of the use of low supply potentials, maximum internal electric fields and depletion widths are correspondingly limited. In turn, these limitations are responsible for increases in cross-talk and decreases in charge-handling capacities. Moreover, for small pixels, lateral depletion cannot be extended. These adverse effects are even more accentuated in a back-illuminated CMOS imager, in which photogenerated charge carriers must travel across the entire thickness of the device. The figure shows a partial cross section of the structure in the device layer of the present developmental CMOS imager. (In a practical imager, the device layer would sit atop either a heavily doped silicon substrate or a thin silicon oxide layer on a silicon substrate, not shown here.) The imager chip is divided into two areas: area C, which contains readout circuits and other electronic circuits; and area I, which contains the imaging (photodetector and photogenerated-charge-collecting) pixel structures. Areas C and I are electrically isolated from each other by means of a trench filled with silicon oxide. The electrical isolation between areas C and I makes it possible to apply different supply potentials to these areas, thereby enabling optimization of the supply potential and associated design features for each area. More specifically, metal oxide semiconductor field-effect transistors (MOSFETs) that are typically included in CMOS imagers now reside in area C and can remain unchanged from established designs and operated at supply potentials prescribed for those designs, while the dopings and the lower supply potentials in area I can be tailored to optimize imager performance. In area I, the device layer includes an n+ -doped silicon layer on which is grown an n-doped silicon layer. A p-doped silicon layer is grown on top of the n -doped layer. The total imaging device thickness is the sum of the thickness of the n+, n, and p layers. A pixel photodiode is formed between a surface n+ implant, a p implant underneath it, the aforementioned p layer, and the n and n+ layers. Adjacent to the diode is a gate for transferring photogenerated charges out of the photodiode and into a floating diffusion formed by an implanted p+ layer on an implanted n-doped region. Metal contact pads are added to the back-side for providing back-side bias.

Pain, Bedabrata↗

PIXEL2020: Tenth International Workshop on Semiconductor Pixel Detectors for Particles and Imaging

This workshop covers various topics related to pixel detector technology. Development and applications will be discussed for charged particle tracking in High Energy Physics, Nuclear Physics, Astrophysics, and X-ray imaging in Astronomy, Biology, Medicine and Material Science. The conference program will also include reports on front and back end electronics, radiation effects, low mass mechanics and construction techniques, and new technologies such as monolithic and 3D integrated detectors.

Sally, Seidel↗

The nanoscale distribution of copper and its influence on charge collection in CdTe solar cells

For decades, Cu has been the primary dopant in CdTe photovoltaic absorbers. Typically, Cu acceptor concentrations in these devices are on the order of 1 1014 cm-3, which has made it notoriously difficult to directly correlate nanoscale Cu distributions to the local charge transport properties of these devices. To measure and correlate these properties, measurement techniques require high sensitivity to elemental concentration, large penetration depth, and operando compatibility. Techniques such as secondary-ion mass spectroscopy and X-ray energy dispersive spectroscopy are widely adopted to measure Cu concentrations, but they are limited by penetration depth, sensitivity, or spatial resolution. Additionally, they lack the operando capabilities required to correlate one-to-one Cu concentrations to electrical performance. In this work, correlative X-ray microscopy is used to investigate the spatial distribution of Cu and its impact on charge collection through the depth and breadth of CdTe photovoltaic devices. Plan-view, nanoscale X-ray fluorescence maps clearly demonstrate the spatial segregation of copper around regions thought to be CdTe grain boundaries. Complementary cross-section imaging unveils the transition of the maximum charge-collection efficiency from the ZnTe-CdTe interface to the CdS-CdTe interface as a function of Cu incorporation. The copper concentration through the depth of the CdTe layer is characterized by slow and fast diffusion components, and cross-section charge-transport modeling shows that the experimentally obtained charge collection can be explained by the modeled acceptor distribution through the depth of the CdTe layer.

14 SOLAR ENERGY↗

Deblending galaxies with variational autoencoders: A joint multiband, multi-instrument approach

ABSTRACT Blending of galaxies has a major contribution in the systematic error budget of weak-lensing studies, affecting photometric and shape measurements, particularly for ground-based, deep, photometric galaxy surveys, such as the Rubin Observatory Legacy Survey of Space and Time (LSST). Existing deblenders mostly rely on analytic modelling of galaxy profiles and suffer from the lack of flexible yet accurate models. We propose to use generative models based on deep neural networks, namely variational autoencoders (VAE), to learn probabilistic models directly from data. We train a VAE on images of centred, isolated galaxies, which we reuse, as a prior, in a second VAE-like neural network in charge of deblending galaxies. We train our networks on simulated images including six LSST bandpass filters and the visible and near-infrared bands of the Euclid satellite, as our method naturally generalizes to multiple bands and can incorporate data from multiple instruments. We obtain median reconstruction errors on ellipticities and r-band magnitude between ±0.01 and ±0.05, respectively, in most cases, and ellipticity multiplicative bias of 1.6 per cent for blended objects in the optimal configuration. We also study the impact of decentring and prove the method to be robust. This method only requires the approximate centre of each target galaxy, but no assumptions about the number of surrounding objects, pointing to an iterative detection/deblending procedure we leave for future work. Finally, we discuss future challenges about training on real data and obtain encouraging results when applying transfer learning.

Arcelin, Bastien↗

UT-NE Radiation Instrumentation Research Group Meeting: An Update on Progress

The purpose of this project is to design a system to image large and/or thick objects with high dynamic ranges using an intensified, charge coupled device (CCD) camera and a fast-pulsed, high energy neutron source; Improve image resolution by reducing scatter; and Design ultra-fast scintillator using nanotechnology to allow for better timing (and thus better scatter rejection).

07 ISOTOPE AND RADIATION SOURCES↗

Fleet Size Requirements for Each GSE Type at Each Airport

This dataset contains the required number of vehicles for each GSE type at each airport under six charging scenarios: (1) charging when the battery state of charge is insufficient for the next service using 40-kW chargers (S1); (2) charging when the battery state of charge is insufficient for the next service using 20-kW chargers (S2); (3) charging starts immediately after each GSE completes a service task using 40-kW chargers (S3); (4) charging starts immediately after each GSE completes a service task using 20-kW chargers (S4); (5) charging during off-peak hours using 40-kW chargers (S5); and (6) charging during off-peak hours using 20-kW chargers (S6). ![image](gse-vehicles-chargers.png) Number of GSE vehicles per GSE type and chargers required for different airport categories under charging scenario 1.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Gravitational lensing of stars orbiting Sgr A* as a probe of the black hole metric in the Galactic center

We show that a possible astrophysical experiment, detection of lensed images of stars orbiting close to Sgr A*, can provide insight into the form of the metric around a black hole. We model Sgr A* as a black hole and add in a {proportional_to}(1/r{sup 2}) term to the Schwarzschild metric near the black hole. We then attempt to determine the effect of this extra term on the properties of the secondary images of the S stars in the Galactic center. When the (1/r{sup 2}) term is positive, this represents a Reissner-Nordstrom metric. We show that there is little observational difference between a Schwarzschild black hole and a Reissner-Nordstrom black hole, leading to the conclusion that secondary images may not be a useful probe of electrical charge in black holes. A negative value for the (1/r{sup 2}) term can enter through modified gravity scenarios. Although physically unlikely to apply in the case of a large black hole, the Randall-Sundrum II braneworld scenario admits a metric of this form, known as the tidal Reissner-Nordstrom metric. We use values of tidal charge (Q in (Q/r{sup 2})) ranging from -6.4M{sup 2} to 1.6M{sup 2}. A negative value of Q enhances the brightness of images at all times and creates an increase in brightness of up to 0.4 magnitudes for the secondary image of the star S2 at periapse. We show that for other stars with brighter secondary images and positions more aligned with the optic axis, using the tidal Reissner-Nordstrom metric with negative Q enhances the images as well. However, the effect is less pronounced. This effect is related to the increase in the size of the photon sphere in this spacetime and, therefore, should be noticeable in other metrics with a similar effect on the photon sphere. With the next generation of instruments and increased knowledge of radiation from Sgr A*, we may be able to use properties of secondary images to place constraints on the size of the (1/r{sup 2}) term. This knowledge will be useful in constraining any modified gravity theory that adds a similar term into the strong field near a black hole.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time-resolved quantitative multiphase interferometric imaging of a highly focused ultrasound pulse

Interferometric imaging is a well-established method to image phase objects by mixing the image wavefront with a reference one on a CCD camera. It has also been applied to fast transient phenomena, mostly through the analysis of single interferograms. It is shown that, for repetitive phenomena, multiphase acquisition brings significant advantages. A 1MHz focused sound field emitted by a hemispherical piezotransducer in water is imaged as an example. Quantitative image analysis provides high resolution sound field profiles. Pressure at focus determined by this method agrees with measurements from a fiber-optic probe hydrophone. This confirms that multiphase interferometric imaging can indeed provide quantitative measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probing the Formation of Cathode-Electrolyte Interphase on Lithium Iron Phosphate Cathodes via Operando Mechanical Measurements

Interfacial instabilities in electrodes control the performance and lifetime of Li-ion batteries. While the formation of solid-electrolyte interface (SEI) on anodes has received much attention, there is still lack of understanding about the formation of cathode-electrolyte interface (CEI) on the cathodes. To fill this gap, we report on dynamic deformations on lithium iron phosphate, LiFePO 4 cathodes during charge / discharge by utilizing in-operando digital image correlation, impedance spectroscopy and Cryo X-ray photoelectron spectroscopy. LiFePO4 cathodes were cycled in either LiPF 6 , LiClO 4 or LiTFSI- containing organic liquid electrolytes. Beyond the first cycle, Li-ion intercalation results in a nearly linear correlation between electrochemical strains and the state of (dis)-charge, regardless of the electrolyte chemistry. However, during the first charge in LiPF 6 - containing electrolyte, there is a distinct irreversible positive strain evolution at the onset of anodic current rise as well as current decay at around 4.0V. Impedance studies show the increase in surface resistance in the same potential window, suggesting the formation of CEI layers on the cathode. The chemistry of the CEI layer was characterized by X-ray photoelectron spectroscopy. LiF is detected in CEI layer starting as early as 3.4 V and Li $x$ PO $y$ F $z$ appeared at voltages higher than 4.0 V during the first charge. In conclusion, our approach offers new insights into the formation mechanism of CEI layers on the cathode electrodes, which is crucial for the development of robust cathode and electrolyte chemistries for higher performance batteries.

25 ENERGY STORAGE↗

Image quality assessment for CT used on small animals

Image acquisition on a CT scanner is nowadays necessary in almost any kind of medical study. Its purpose, to produce anatomical images with the best achievable quality, implies the highest diagnostic radiation exposure to patients. Image quality can be measured quantitatively based on parameters such as noise, uniformity and resolution. This measure allows the determination of optimal parameters of operation for the scanner in order to get the best diagnostic image. A human Phillips CT scanner is the first one minded for veterinary-use exclusively in Colombia. The aim of this study was to measure the CT image quality parameters using an acrylic phantom and then, using the computational tool MATLAB, determine these parameters as a function of current value and window of visualization, in order to reduce dose delivery by keeping the appropriate image quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Miniature CCD X-Ray Imaging Camera Technology Final Report CRADA No. TC-773-94

The goal of the project was to develop a compact, large active area, high spatial resolution, high dynamic range, charge-coupled device (CCD) camera to replace film for digital imaging of visible light, ultraviolet radiation, and soft to penetrating X-rays. The camera head and controller needed to be capable of operation within a vacuum environment and small enough to be fielded within the small vacuum target chambers at LLNL.

42 ENGINEERING↗

A high-resolution coherent transition radiation diagnostic for laser-produced electron transport studies (invited)

High-resolution images of the rear-surface optical emission from high-intensity (I{approx}10{sup 19} W/cm{sup 2}) laser illuminated metal foils have been recorded using coherent transition radiation (CTR). CTR is generated as relativistic electrons, generated in high-intensity laser-plasma interactions, exit the target's rear surface and move into vacuum. A transition radiation diagnostic (TRD) records time-integrated images in a 24 nm bandwidth window around {lambda}=529 nm. The optical transmission at {lambda}=1053 nm, the laser wavelength, is 15 orders of magnitude lower than the transmission at the wavelength of interest, {lambda}=527 nm. The detector is a scientific grade charge-coupled device (CCD) camera that operates with a signal-to-noise ratio of 10{sup 3} and has a dynamic range of 10{sup 4}. The TRD has demonstrated a spatial resolution of 1.4 {mu}m over a 1 mm field of view, limited only by the CCD pixel size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Empirical electro-optical and x-ray performance evaluation of CMOS active pixels sensor for low dose, high resolution x-ray medical imaging

Monolithic complementary metal oxide semiconductor (CMOS) active pixel sensors with high performance have gained attention in the last few years in many scientific and space applications. In order to evaluate the increasing capabilities of this technology, in particular where low dose high resolution x-ray medical imaging is required, critical electro-optical and physical x-ray performance evaluation was determined. The electro-optical performance includes read noise, full well capacity, interacting quantum efficiency, and pixels cross talk. The x-ray performance, including x-ray sensitivity, modulation transfer function, noise power spectrum, and detection quantum efficiency, has been evaluated in the mammographic energy range. The sensor is a 525x525 standard three transistor CMOS active pixel sensor array with more than 75% fill factor and 25x25 {mu}m pixel pitch. Reading at 10 f/s, it is found that the sensor has 114 electrons total additive noise, 10{sup 5} electrons full well capacity with shot noise limited operation, and 34% interacting quantum efficiency at 530 nm. Two different structured CsI:Tl phosphors with thickness 95 and 115 {mu}m, respectively, have been optically coupled via a fiber optic plate to the array resulting in two different system configurations. The sensitivity of the two different system configurations was 43 and 47 electrons per x-ray incident on the sensor. The MTF at 10% of the two different system configurations was 9.5 and 9 cycles/mm with detective quantum efficiency of 0.45 and 0.48, respectively, close to zero frequency at {approx}0.44 {mu}C/kg (1.72 mR) detector entrance exposure. The detector was quantum limited at low spatial frequencies and its performance was comparable with high resolution a:Si and charge coupled device based x-ray imagers. The detector also demonstrates almost an order of magnitude lower noise than active matrix flat panel imagers. The results suggest that CMOS active pixel sensors when coupled to structured CsI:Tl can be used for conventional and advanced digital mammography due to their low noise, high resolution performance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

HII regions in IC 1613: The ISM in a nearby dwarf irregular galaxy

IC 1613, a nearby (725 kpc distant) dwarf irregular galaxy, has always been known to contain large, ring-shaped HII regions in its northeast corner. A new H alpha image has been obtained using the Bell Labs Charge Coupled Device (CCD) camera, an RCA 320 X 512 pixel-thinned, back-illuminated CCD, an H alpha filter of central wavelength 6562 A and width (full width half maximum) of 30 A, and the 42 inch telescope at Lowell Observatory. The low resolution images exhibit many new, faint features.

Price, Jill S.↗

Observation of hydrodynamic plasmons and energy waves in graphene

Thermally excited electrons and holes form a quantum-critical Dirac fluid in ultraclean graphene and their electrodynamic responses are described by a universal hydrodynamic theory. The hydrodynamic Dirac fluid can host intriguing collective excitations distinctively different from those in a Fermi liquid. Here we report the observation of the hydrodynamic plasmon and energy wave in ultraclean graphene. In this study, we use the on-chip terahertz (THz) spectroscopy technique to measure the THz absorption spectra of a graphene microribbon as well as the propagation of the energy wave in graphene close to charge neutrality. We observe a prominent high-frequency hydrodynamic bipolar-plasmon resonance and a weaker low-frequency energy-wave resonance of the Dirac fluid in ultraclean graphene. The hydrodynamic bipolar plasmon is characterized by the antiphase oscillation of massless electrons and holes in graphene. The hydrodynamic energy wave is an electron-hole sound mode with both charge carriers oscillating in phase and moving together. The spatial–temporal imaging technique shows that the energy wave propagates at a characteristic speed of $V_f$ / $ \sqrt2$ near the charge neutrality. Our observations open new opportunities to explore collective hydrodynamic excitations in graphene systems.

36 MATERIALS SCIENCE↗

Micro-Raman imaging of isomeric segregation in small-molecule organic semiconductors

Abstract Charge transport in organic semiconductors is highly sensitive to film heterogeneity and intermolecular interactions, but probing these properties on the length scales of disorder is often difficult. Here we use micro-Raman spectroscopy to assign vibrational modes of isomerically pure syn and anti 2,8-difluoro-5,11-bis(triethylsilylethynyl)anthradithiophene (diF-TES ADT) by comparing to density functional theory calculations. With polarization-dependent measurements, we determine the orientation of crystallites in pure isomers. In mixed-isomer samples, we observe narrow linewidths and superposition spectra, indicating coexistence of isomerically pure sub-domains on length scales smaller than the probe area. Using the ring breathing modes close to 1300 cm −1 as indicators of the pure isomer crystalline sub-domains, we image their spatial distribution with 200-nm resolution. These results demonstrate the power of micro-Raman spectroscopy for investigating spatial heterogeneities and clarifying the origin of the reduced charge carrier mobility displayed in mixed-isomer diF-TES ADT.

Huang, Chiung-Wei (ORCID:0000000307361362)↗