Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat engine”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Amplitude of Supersonic Diffuser Flow Pulsations

A theoretical method for evaluating the stability characteristics and the amplitude and the frequency of pulsation of ram-jet engines without heat addition is presented herein. Experimental verification of the theoretical results are included where data were available. Theory and experiment show that the pulsation amplitude of a high mass-flow-ratio diffuser having no cone surface flow separation increases with decreasing mass flow. The theoretical trends for changes in amplitude, frequency, and mean-pressure recovery with changes in plenum-chamber volume were experimentally confirmed. For perforated convergent-divergent-type diffusers, a stability hysteresis loop was predicted on the pressure-recovery mass-flow-ratio curve. At a given mean mass-flow ratio, the higher.value of mean pressure recovery corresponded to oscillatory flow in the diffuser while the lower branch was stable. This hysteresis has been observed experimentally. The theory indicates that for a ram-jet engine of given diameter, the amplitude of pulsation of a supersonic diffuser is increased by decreasing the relative size of the plenum chamber with respect to the diffuser volume down to a critical value at which oscillations cease. In the region of these critical values, the stable mass-flow range of the diffuser may be increased either by decreasing the combustion chamber volume or by increasing the length of the diffuser.

Sterbentz, William H.↗

Methods of forming thermal management systems and thermal management methods

A thermal management system for a vehicle includes a heat exchanger having a thermal energy storage material provided therein, a first coolant loop thermally coupled to an electrochemical storage device located within the first coolant loop and to the heat exchanger, and a second coolant loop thermally coupled to the heat exchanger. The first and second coolant loops are configured to carry distinct thermal energy transfer media. The thermal management system also includes an interface configured to facilitate transfer of heat generated by an internal combustion engine to the heat exchanger via the second coolant loop in order to selectively deliver the heat to the electrochemical storage device. Thermal management methods are also provided.

25 ENERGY STORAGE↗

Thermochemical reduction modeling in a high-temperature moving-bed reactor for energy storage: 1D model

The design of robust and efficient high-temperature thermochemical reactors and determination of operating conditions are critical steps toward enabling high-efficiency long-duration solar energy storage. This work presents a computational model for the thermal reduction of a metal oxide material (Mg-Mn-O) up to 1450 °C and the coupled complex transport phenomena in a novel tubular thermal reactor design that features the capability for a high extent-of-reduction (high energy storage density) and inherent heat recuperation. A one-dimensional model coupling counter-current gas–solid flow, two-phase heat transfer, thermochemical redox reactions, and species transport in a moving-bed reactor is developed. Simplified versions of the model are validated with published results in the literature for packed beds with both inert and reactive particles; the fully coupled model is also validated with experimental measurements of a moving-bed reactor in terms of local temperatures and oxygen release at the exit. Detailed comparisons on the effects of different boundary conditions in the reaction zone (prescribed wall temperature vs. heat flux conditions) and formulations based on a simple uniform flow assumption vs. plug flow using Ergun equation for gas flow are investigated. The results are compared with experimental measurements, and for all cases, the energy flow components in the reactor system and the thermal to chemical conversion efficiency and overall system efficiency are computed. Finally, the predicted high thermal-to-chemical efficiency ~95% and system efficiency ~30% agree with experimental measurements.

25 ENERGY STORAGE↗

Thermal-hydraulic performance of metal foam heat exchangers under dry operating conditions

High porosity metal foams with novel thermal, mechanical, electrical, and acoustic properties are being more widely adopted for application. Due to their large surface-area-to-volume ratio and complex structure which induces better fluid mixing, boundary layer restarting and wake destruction, they hold promise for heat transfer applications. In this study, the thermal-hydraulic performance of open-cell aluminum metal foam heat exchanger has been evaluated. The impact of flow conditions and metal foam geometry on the heat transfer coefficient and gradient have been investigated. Metal foam heat exchanger with same geometry (face area, flow depth and fin dimensions) consisting of four different type of metal foams have been built for the study. Experiments are conducted in a closed-loop wind tunnel at different flow rate under dry operating condition. Metal foams with a smaller pore size (40 PPI) have a larger heat transfer coefficient compared to foams with a larger pore size (5 PPI). However, foams with larger pores result in relatively smaller pressure gradients. Current thermal-hydraulic modeling practices have been reviewed and potential issues have been identified. Permeability and inertia coefficients are determined and compared to data reported in open literature. Finally, on the basis of the new experimental results, correlations are developed relating the foam characteristics and flow conditions through the friction factor f and the Colburn j factor.

36 MATERIALS SCIENCE↗

Development of Numerical Model of Metal Foam with PCM for the Estimation of Effective Thermal Conductivity

Global warming due to climate change is a threat to humankind. Nuclear energy is one of the promising solutions to reduce fossil fuel usage. Nuclear energy can handle the base load, compensating for the volatility of renewable energy. If nuclear energy could achieve load following capability, the combination with renewable energy would be more suitable. Thermal energy storage (TES) is one of the options for enabling load following of nuclear reactors. The TES makes it possible to store surplus nuclear thermal energy and release it later as needed. In Idaho National Laboratory (INL), a new concept of latent heat TES integrated with high-temperature heat pipe has been proposed and is under development, which is called Heat pipe-Integrated Thermal Battery (HITB). HITB exchanges thermal energy between the reactor system and TES via heat pipe. The heat transferred to TES medium, made of phase change material (PCM), stores energy as sensible heat and/or latent heat. As PCM typically has poor thermal conductivity, however, various heat transfer enhancement techniques are required to achieve a rapid charging cycle. There are many techniques to enhance the heat transfer ability of TES medium such as disk, fin, and metal foam. Among them, metal foam is an appropriate option to enhance the heat transfer because it maximizes the heat transfer area through metal wicks. Metal foam is a lightweight metal structure that has a high porosity of over 0.9. The typical materials for metal foam are Aluminum, Copper, Nickel, and Silicon Carbide (SiC). Metal foam not only enhances heat transfer via conduction but also increases contact surface area. In the HITB design , the metal foam is being considered as one of the options to enhance the heat transfer of TES medium (PCM) [1]. To predict the enhanced thermal performance of TES, one should properly estimate the effective thermal conductivity of metal foam combined with PCM material or calculate heat transfer in distributed model. There are many experimental works that provides effective thermal conductivity of metal foam with various PCM [2,3]. Also, many theoretical models were developed based on the unit cell model of metal foam [4,5]. With a distributed model, on the other hand, detail heat transfer characteristics between metal foam and PCM material can be analyzed considering the geometry or buoyancy effect. However, due to the complex geometry of metal foam pores, the computational cost for three-dimensional modeling highly increases. Therefore, if metal foam structure can be modeled in simple and repetitive design, the computational cost would decrease Among the various metal foam models [2], lattice model is one of the simple and extendable design. The porosity and pores per inch (PPI) can be characterized by the size and spatial distance of lattice structure. If the three-dimensional metal foam model consists of lattice structure could properly estimate the heat transfer, which is characterized by effective thermal conductivity, it would be a good option to assess the thermal performance of metal foam with PCM. In this study, a three-dimensional numerical model was developed to simulate conductive heat transfer between metal foam and PCM. The three-dimensional lattice structure of square pillars was selected as a basic structure of the metal foam. The calculation result was characterized by the effective thermal conductivity of the whole domain. A sensitivity study was conducted for mesh size, domain size, and PPI to check whether the calculation result gives a converged result or not. Lastly, the effective thermal conductivity from the lattice model was compared with existing experimental data to validate the model result

25 ENERGY STORAGE↗

Quantum thermodynamic devices: From theoretical proposals to experimental reality

Thermodynamics originated in the need to understand novel technologies developed by the Industrial Revolution. However, over the centuries, the description of engines, refrigerators, thermal accelerators, and heaters has become so abstract that a direct application of the universal statements to real-life devices is everything but straight forward. Furthermore, the recent, rapid development of quantum thermodynamics has taken a similar trajectory, and, e.g., “quantum engines” have become a widely studied concept in theoretical research. However, if the newly unveiled laws of nature are to be useful, we need to write the dictionary that allows us to translate abstract statements of theoretical quantum thermodynamics to physical platforms and working mediums of experimentally realistic scenarios. To assist in this endeavor, this review is dedicated to provide an overview over the proposed and realized quantum thermodynamic devices and to highlight the commonalities and differences of the various physical situations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of the Convective Heat-Exchange Coefficient in Inner Channels of Light-Absorbing Heat-Exchange Panels of Flat-Plate Solar Water-Heating Collectors Based on the Results of Their Short-Term Thermal Testing in Full-Scale Conditions

The results of investigations to determine the convective heat-exchange coefficient in the inner heat-exchange channels (HECs) of the light-absorbing heat-exchange panels (LAHPs) of flat-plate solar water-heating collectors (FPSWHCs) are given based on the results of their short-term heat testing in fullscale quasi-stationary conditions. The research method is based on determining the value of the required parameter from the heat-balance equation formed for the inner surfaces of the LAHP HEC walls. The structures of the flow LAHPs with a sheet-piped and thin parallelepiped form are selected as the test objects. The thermal tests of the FPSWHC are carried out during the near-midday hours of the light day to ensure the quasi-stationary mode condition. The reliability of the proposed method and results of the investigations is proved by comparing the values of the thermal-efficiency coefficients of the FPSWHC LAHPs obtained using two independent approaches.

14 SOLAR ENERGY↗

Motorette Thermal Performance Testing and Modeling for an Electric Motor with Additively Manufactured Hollow Conductors with Integrated Heat Pipes

This paper discusses the design, build and test of a motorette to characterize the thermal performance of an additively manufactured coil integrated with heat pipes. The motorette is powered using a variable frequency AC power supply and cooled through two independent cooling systems. The first cooling system cools the stator core using forced convection of air flowing over a finned heat sink mounted on the stator outer diameter. The second cooling system cools the heat pipes using forced convection of 50-50 water ethylene glycol (WEG) mixture flowing through condenser chambers. A 3D thermal FEA model of the setup is built and heat transfer coefficients (HTC) of convective boundaries are computed using coolant flow rates from test data and empirical equations. Temperature at locations on the coil and heat sink are recorded and compared to thermal model predicted values. A maximum temperature error of 22.7% occurs at 180ARMS and 800 Hz operating point for the AM dual coil. The thermal model provides higher temperatures compared to test results and hence it is on the conservative side but in general, there is good correlation between test and model results. Lastly, opportunities for improvement to both test data measurement and 3D thermal FEA modeling are discussed.

additive manufacturing↗

Numerical thermal analyses of heat exchangers for the stirling engine application

The Regenerator, Cooler and Heater for the NASA Space Power Research Engine (SPRE) have been analyzed in detail for laminar, incompressible and oscillatory flow conditions. Each component has been analyzed independently and in detail with the regenerator being modeled as two-parallel-plates channel with a solid wall. The ends of the channel are exposed to two reservoir maintained at different temperature thus providing an axial temperature gradient along the channel. The cooler and heater components have been modeled as circular pipes with isothermal walls. Two different types of thermal boundary conditions have been investigated for the cooler and heater, namely, symmetric and asymmetric temperature inflow. In symmetric temperature inflow the flow enters the channel with the same temperature in throughout the velocity cycle whereas, in asymmetric temperature inflow the flow enters with a different temperature in each half cycle. The study was conducted over a wide range of Maximum Reynolds number (RE(max) varying from 75 to 60000, Valensi number (Va) from 2.5 to 800, and relative amplitude of fluid displacement (A(sub r) from 0.357 to 1.34. A two dimensional Finite volume method based on the SIMPLE algorithm was used to solve the governing partial differential equations. Post processing programs were developed to effectively describe the heat transfer mechanism under oscillatory flows. The computer code was validated by comparing with existing analytical solutions for oscillating flows. The thermal field have been studied with the help of temperature contour and three dimensional plots. The instantaneous friction factor, wall heat flux and heat transfer coefficient have been examined. It has been concluded that in general, the frictional factor and heat transfer coefficient are higher under oscillatory flow conditions when the Valensi number is high. Also, the thermal efficiency decreases for lower A(r) values. Further, the usual steady state definition for the heat transfer coefficient does not seem to be valid.

Kannapareddy, Mohan Raj↗

Performance Investigation of High-temperature Latent Heat Storage for Integration with Advanced Nuclear Reactors

Integrating thermal energy storage (TES) with advanced nuclear reactors enhances the flexible use of nuclear energy, facilitating its expansion beyond conventional electricity generation. High-temperature TES, capable of storing heat above 400 degree C, emerges as a vital carbon-free energy solution for decarbonizing industrial sector, especially when combined with low-emission energy sources like advanced nuclear reactors. Idaho National Laboratory (INL) has recently developed a novel design for high-temperature latent heat storage system, called Heat pipe Integrated Thermal Battery (HITB), and efforts are underway to experimentally demonstrate the concept. HITB employs liquid-metal heat pipes to establish thermal linkage between TES and nuclear systems without direct fluid exchange, minimizing the potential risk of the integrated systems such as cross-contamination. HITB is designed to achieve high charging and discharging efficiency as well as high energy storage density by employing metal alloys as Phase Change Material (PCM). Initial proof-of-concept experiments are being undertaken using an aluminum alloy (Al59%-Mg35%-Zn6%). This paper discusses current progress of the HITB project at INL, seeking to develop high-temperature TES for versatile integration with advanced nuclear reactors, and shares insights from the performance evaluations via numerical modeling and analysis.

25 ENERGY STORAGE↗

Flexible cryogenic air separation unit—An application for low-carbon fossil-fuel plants

In this study, the rapid integration of intermittent renewable sources into the electricity grid is driving the need for a flexible cryogenic air separation unit (ASU) coupled with a low-carbon fossil-fuel plant. However, the state-of-the-art ASU process is highly integrated and nonlinear, which can significantly restrict its ramping rate. In this work, we study the fundamental dynamics of a state-of-the-art double-column ASU, focusing on the dynamic characteristics of the highly integrated and nonlinear heat and mass transfers, and we propose basic control methods for achieving high process ramping rates. We found that the vapor–liquid countercurrent flows in the low-pressure column are critical to the cryogenic rectification of air, which governs the ramp rate of the ASU. This countercurrent flow structure is created through a complex heat integration process in the ASU. Here, this process is simplified as a countercurrent heat transfer to reduce the complexity of studying the ASU dynamics. To preserve this flow structure, the heat integration is maintained so that its heat duty follows the ASU load, using several basic controllers on the critical stream flowrates. A flow-driven dynamic ASU model is built in Aspen Plus Dynamics to capture the basic ramping dynamics. This model revealed a fundamental mismatch in the dynamics in the ASU column that causes a significant loss of O 2 product purity when ramping down the ASU and slightly increases the purity when ramping up. Based on these findings, we propose a basic control method for rapidly ramping down/up the ASU while maintaining O 2 product purity. Simulation results show the ASU basic dynamic process successfully ramps at a rate up to 10 %/min (40–100 % load) while maintaining the O 2 product purity at 95.2–95.6 mol%.

42 ENGINEERING↗

Pilot scale testing of an advanced solvent in a 0.7 MWe post-combustion CO 2 capture unit

An advanced Amine Promoted Buffer Solution (APBS), APBS-CDRMax® (CDRMax), developed by Carbon Clean Solutions Limited (CCSL), was tested at the 0.7 MWe CO 2 capture facility at Kentucky Utilities E.W. Brown Generation Station using a heat-integrated two-staged stripping CO 2 capture process. The performance of the solvent was evaluated to determine operating conditions that maximized the cyclic capacity of the solvent and results in energy savings. The regeneration energy ranged from 2.9 to 3.3 GJ/ton CO 2 with 14 vol % (dry) CO 2 inlet and approximately 90 % capture. The difference in the reboiler specific heat duty at stripper pressures of 1.7 and 2.1 bar was minimal as similar amounts of water vapor were observed in the CO 2 product stream at stripper outlet. Recycling of product CO 2 increased the inlet CO 2 concentration to the absorber from 14 to 16 vol% which enhanced mass transfer from the gas to the solvent resulting in about 5 % reduction in the energy of regeneration at the lower stripper pressure. The solvent circulation rate was reduced by about 30 % relative to previous 30 wt% MEA campaign for the CO 2 target capture of 90 %. Finally, the reduced solvent make-up rate of CDRMax shows promise for capital and operating cost savings for post-combustion CO 2 capture.

42 ENGINEERING↗

Characterization of multi-regime reaction zones in a piloted inhomogeneous jet flame with local extinction

In this study, gradient free regime identification (GFRI) is applied to 1D Raman/Rayleigh/LIF measurements of temperature and major species from the intermediate velocity case of the Sydney piloted inhomogeneous jet flame series to better understand the structure of reaction zones and the downstream evolution of multi-regime characteristics. The GFRI approach allows local reaction zones to be detected and characterized as premixed, dominantly premixed, multi-regime, dominantly non-premixed, or non-premixed flame structures, based on flame markers (mixture fraction, chemical mode, and heat release rate) derived from the experimental data. The statistics of chemical mode zero-crossings, which mark premixed reaction zones, and the relative populations of flame structures are shown to be sensitive to the state of mixing in the near field of the flame and to the level of local extinction farther downstream. Multi-regime structures, where premixed and non-premixed reaction zones occur in close proximity and both contribute to overall heat release, account for nearly half the total population at streamwise locations within the first several jet diameters. There is a rapid transition within the near field whereby the relative population of non-premixed and dominantly non-premixed structures grows from 0.05 to nearly 0.5, and the population of premixed and dominantly premixed structures decreases correspondingly as fluid entering the reaction zone becomes progressively fuel-rich. Local extinction and re-ignition bring a resurgence in premixed-type structures, many of which occur at fuel-lean conditions. There are also modest populations of multi-regime structures, having chemical mode zero-crossings at lean conditions, which would not exist in a fully burning jet flame.

42 ENGINEERING↗

An in situ cell to study phase transitions in individual aerosol particles on a substrate using scanning transmission x-ray microspectroscopy

A new in situ cell to study phase transitions and chemical processes on individual aerosol particles in the x-ray transmission microscope at the PolLux beamline of the Swiss light source has been built. The cell is machined from stainless steel and aluminum components and is designed to be used in the standard mount of the microscope without need of complicated rearrangements of the microscope. The cell consists of two parts, a back part which contains connections for the gas supply, heating, cooling devices, and temperature measurement. The second part is a removable clip, which hosts the sample. This clip can be easily exchanged and brought into a sampling unit for aerosol particles. Currently, the cell can be operated at temperatures ranging from -40 to +50 deg. C. The function of the cell is demonstrated using two systems of submicron size: inorganic sodium bromide aerosols and soot originating from a diesel passenger car. For the sodium bromide we demonstrate how phase transitions can be studied in these systems and that O1s spectra from aqueous sodium bromide solution can be taken from submicron sized particles. For the case of soot, we demonstrate that the uptake of water onto individual soot particles can be studied.

36 MATERIALS SCIENCE↗

Mixed convection heat transfer in a differentially heated cavity with two rotating cylinders

Mixed convection heat transfer in a differentially heated cavity with two rotating cylinders was studied numerically for various pertinent parameters such as Richardson number, Reynolds number, non-dimensional rotation speed of the cylinder, and the location of the cylinders. The results from these simulations were validated using an open-source spectral element code, Nek5000. The results of this study were presented in terms of streamlines, isotherms, local and average Nusselt number, and temperature profiles. The results illustrated that the average Nusselt number depends strongly on the rotation speed of the cylinder, Reynolds number, and Richardson number. However, the average Nusselt number was found to be independent of the rotation speed at high Richardson number (Ri = 10). In addition, the direction of the rotation speed of the cylinders has a profound effect on the average Nusselt. Finally, the study illustrated that the magnitude and direction of the rotation speed of the cylinders have a significant effect on the flow pattern and isotherms.

42 ENGINEERING↗

Optimization of R290 variable geometry heat exchangers

Air-to-refrigerant heat exchangers (HX) are vital components in Heating, Ventilating and Air Conditioning and Refrigeration (HVAC&R) equipment. Recent literature has proposed utilizing shape-optimized, non-round tubes to reduce component size and refrigerant charge, thus enabling the adoption of low-GWP natural refrigerants like R290. However, most designs are restricted to fixed tube configurations, limiting the overall performance potential. In this work, multi-objective optimization is used in a staged approach to develop variable geometry multi-pass air-to-R290 HXs with minimal volume and airside pressure drop. Non-round tubes are used throughout the domain and each pass may have different tube arrangements to maximize HX performance. Compared to conventional fin-tube HXs, the optimized designs demonstrate more than 60% reductions in envelope volume, 30% reductions in face area, and up to 24% reduction in airside pressure drop. Additionally, the refrigerant charge reduction was up to 64%, thus enabling safe use of flammable and mildly-flammable refrigerants.

42 ENGINEERING↗

Effect of heat treatment on microstructural evolution and hardness homogeneity in laser powder bed fusion of alloy 718

The thermal history developed in laser powder bed fusion (LPBF) processes has been shown to be complex resulting in equally complex microstructures and mechanical properties. Microscopic observations and Vickers micro-hardness mapping measurements were carried out on diff ;erent section planes of LPBF alloy 718 cuboids. Three-dimensional finite element analysis was used to simulate thermal history and to predict the residual stress distribution in the as-built material. Computational thermodynamics was used to predict the micro-segregation and nucleation driving force of various phases in the bulk and in segregated regions. Varied heat-treatments such as simulated hot isostatic pressing, and double aging were applied. Their influence on the microstructure, microsegregation, precipitate formation, and micro-hardness variations of LPBF alloy 718 were investigated. Hardness map results showed heterogeneous micro-hardness on the xy- and xz-planes of the as-built parts where the bottom plane and center regions had larger hardness of ~315 HV 0.5 while the top plane and contours showed hardness of ~300 HV 0.5 . It was found that the aging treatment increased the overall hardness of the as-built condition from ~310 HV 0.5 to 470 HV 0.5 but also increased the hardness gradient throughout the coupon. After simulated hot isostatic pressing process (i.e., without applied pressure) at 1020 °C for 4 h followed by water quench (HIPWQ), the hardness gradient and hardness was minimized (~210 HV 0.5 ) as the microstructure transitioned from heterogeneous columnar grains in the as-built condition to more uniform recrystallized grains. A double aging treatment was applied to enhance hardness from ~210 HV 0.5 to ~440 HV 0.5 . Finally, HIPWQ followed by double aging produced a homogeneous microstructure and more uniform hardness map with enhanced mechanical properties in LPBF alloy 718 coupons.

36 MATERIALS SCIENCE↗

Experimental study of a thermal energy storage-integrated heat pump system for load shifting in space cooling and heating

This study experimentally investigates an all-season thermal energy storage-integrated heat pump (TES-HP) system developed to enhance building energy efficiency and support grid-interactive operation through load shifting in both cooling and heating. A 4-ton commercial rooftop air-source heat pump was modified by integrating a hydronic thermal energy storage (TES) unit containing a phase change material (PCM) with a melting temperature of 22.0 °C. The system employs two reversing valves and three electronic expansion valves to enable six operating modes, including normal, TES charging, and TES discharging in both cooling and heating seasons. A subcooling-controlled electronic expansion valve was implemented to mitigate refrigerant maldistribution caused by unequal internal volumes among the heat exchangers. Compared with a baseline heat pump, the TES-HP reduced power consumption by 30–50% during cooling at an ambient temperature of 40.6 °C, and by up to 60% during heating at −15.0 °C, while maintaining high performance under cold-climate conditions. Additionaly to experimental evaluation, a simplified annualized on-peak analysis was conducted to compare the TES-HP with the baseline system, indicating an on-peak electricity reduction of approximately 876 kWhₑ per unit per year and associated on-peak cost savings under time-of-use pricing. These results demonstrate that the TES-HP effectively decouples HP operation from adverse ambient conditions, improving flexibility, resilience, and energy efficiency. This work advances prior research by experimentally proving the integration of PCM-based TES for a year-round, load-flexible HVAC operation.

42 ENGINEERING↗