Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “function unit testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

780 records · Page 44

Towards Energy Scale Calibration and Drift Correction of TES Detectors for Athena X-IFU

The Athena X-Ray Integral Field Unit (X-IFU) comprises a 2376-pixel array of transition edge sensors (TES) read out with time-division multiplexing (TDM). X-IFU will provide spatially resolved, high-resolution spectroscopy (2.5 eV full-width-half-maximum up to 7 keV) over the energy range 0.2 to 12 keV, with an absolute energy scale accuracy of 0.4 eV. The energy scale function maps the optimally filtered pulse height, in arbitrary engineering units, to real calibrated energy. Uncertainties in the calibration can result from imperfect fitting of the energy scale between the known calibration points. Furthermore, temporal changes in the TES operating environment, such as heat-sink temperature, magnetic field and bias voltage, can cause significant variations in the detector gain function over time. If not properly corrected, this can result in degradation of the energy resolution, and systematic errors in the absolute energy scale. The non-linear nature of TES detectors, coupled with the possibility of multiple simultaneously occurring sources of drift, can make effective corrections over the full bandpass of the instrument extremely challenging. Athena X-IFU will employ an on-board calibration source that provides known reference x-ray lines. This provides real-time monitoring of the gain stability of the detector system and information that can be used to correct for gain drifts. For X-IFU the baseline approach is to measure a series of calibration curves under different environmental conditions, which bound the expected drifts the instrument is predicted to see over the course of the mission. Using the information from the in-flight calibration source, these energy scale functions can be interpolated to generate a new corrected energy scale as a function of time. In this paper we discuss progress towards demonstrating that the X-IFU energy scale requirements can be met. We present measurements on ~ 200 pixels in a prototype X-IFU array read out with 8-column x 32-row TDM. We use a rotating target source containing 12 fluorescent targets to generate x-ray lines covering the energy range 4 keV (Sc-Kα) to 12 keV (Br-Kα). We present measurements of the non-linear energy scale function and show how variations in heat-sink temperature, TES bias voltage and magnetic field affect the shape of TES energy scale differently and introduce different residual gain errors over the bandpass. We explore different drift correction algorithms that use either a single or multiple referential lines to track and correct the gain from these various sources of drift. In addition to the pulse-height, the DC ‘baseline’ level of the TES can contain information about its bias conditions. Thus, we test a multi-parameter gain correction algorithm that attempts to incorporate both the pulse height and the additional baseline information into the algorithm.

Stephen J Smith↗

Extending ISS Life Beyond 2030

The United States On-orbit Segment (USOS) of the International Space Station (ISS) was designed to meet a 15-year on-orbit life. Since the first hardware was launched in late 1998, the ISS would have reached its end of life in 2013. With the realization that the ISS would be needed well into the next decade, and beyond, a multi-disciplinary effort was undertaken to extend the ISS’ life through 2028 and to show that further extension to 2040 and beyond is not only feasible but achievable. Currently, NASA and the ISS international partners have agreed to extend its operations through 2030. This collaborative effort ensures that the ISS will continue to serve as a hub for scientific research, international cooperation, and educational endeavors for the next decade. Maintaining a continuous human presence in Low Earth Orbit (LEO) is desirable for testing new LEO, lunar, and deep-space technologies; conducting scientific research in micro-gravity for the benefit of life on Earth; and enabling a seamless transition of capabilities to one or more commercially owned and operated destinations. This paper provides an overview of the ISS life extension project with a particular focus on the analytical approach used to assess the primary structure. This analytical approach includes future operations planning, critical location screening, on-orbit dynamic load simulation, on-orbit optical property degradation studies, on-orbit thermal analyses, spectra generation, crack model idealization, fracture analyses, and post processing. Structural life results and identification of the most critical on-orbit events are presented. Also addressed are life extension approaches for other affected sub-systems, including: 1. Secondary Structure. 2. Materials. Evaluations consider environmental exposure to atomic oxygen, ionizing and gamma radiation, fluids, etc. Life limited materials, wear, and usage effects are also considered. 3. Environmental Control and Life Support Systems, including oxygen supply and generation, water recovery and management, and regenerative hardware. Evaluations are performed to determine which hardware can be run to failure and which are assessed for life extension. 4. Electrical power system. ISS is powered by eight channels of solar arrays and an electrical energy storage system providing 357 kWh power. Power generation and balance analyses are performed considering hardware degradation and increasing power demand. 5. Logistics and maintenance. Analyses are performed to determine critical spares required to maintain functionality. Consideration is given to supply chain health, obsolescence issues, onboard stowage availability, and up-mass capability. The successful life extension results have built confidence to safely operate, maintain and enhance the ISS well beyond the current decade. Extending the operational life of the ISS maintains an international presence in LEO and serves to avoid a gap in capability necessary to fulfill the exploration and research needs of NASA, international partners, and industry without interruption until a commercial space station is operational.

design life↗

An Interoperability Concept for Detect and Avoid and Collision Avoidance Systems: Results from a Human-In-The-Loop Simulation

The integration of Unmanned Aircraft Systems (UAS) into the National Airspace System (NAS) poses a variety of technical challenges to UAS developers and aviation regulators. In response to growing demand for access to civil airspace in the United States, the Federal Aviation Administration (FAA) has produced a roadmap identifying key areas requiring further research and development. One such technical challenge is the development of a "detect and avoid" system (DAA) capable of providing a means of compliance with the "see and avoid" requirement in manned aviation. The purpose of the DAA system is to support the pilot, situated at a ground control station (GCS), in maintaining "DAA well clear" of nearby aircraft through the use of GCS displays and alerts. In addition to its primary function of aiding the pilot in maintaining DAA well clear, the DAA system must also safely interoperate with existing NAS systems and operations, such as the airspace management procedures of air traffic controllers (ATC) and Collision Avoidance (CA) systems currently in use by manned aircraft, namely the Traffic Alert and Collision Avoidance System (TCAS II). It is anticipated that many UAS architectures will integrate both a DAA system and a TCAS II. It is therefore necessary to explicitly study the integration of DAA and TCAS II alerting structures and maneuver guidance formats to ensure that pilots understand the appropriate type and urgency of their response to the various alerts. This paper presents a concept of interoperability for the two systems. The concept was developed with the goal of avoiding any negative impact on the performance level of TCAS II while retaining a DAA system that still effectively enables pilots to maintain DAA well clear. The interoperability concept described in the paper focuses primarily on facilitating the transition from a late-stage DAA encounter (where a loss of DAA well clear is imminent) to a TCAS II Corrective Resolution Advisory (RA), which requires pilot compliance within five seconds of its issuance. The interoperability concept was presented to 10 participants (6 active UAS pilots and 4 active commercial pilots) in a medium-fidelity, human-in-the-loop simulation designed to stress different aspects of the DAA and TCAS II systems. Pilots' ability to maintain separation, their rate of compliance and response times using the interoperability concept are reported. Results indicated that pilots exhibited comprehension of, and appropriate prioritization within, the DAA-TCAS II combined alert structure. Pilots demonstrated a high rate of compliance with TCAS II RAs and were also seen to respond to corrective RAs within the five second requirement established for manned aircraft. The DAA system presented under test was also shown to be effective in supporting pilots' ability to maintain DAA well clear in the overwhelming majority of cases in which pilots had sufficient time to respond.

Rorie, R. Conrad↗

Prototype development and test results of a continuous ambient air monitoring system for hydrazine at the 10 ppb level

A Hydrazine Vapor Area Monitor (HVAM) system is currently being field tested as a detector for the presence of hydrazine in ambient air. The MDA/Polymetron Hydrazine Analyzer has been incorporated within the HVAM system as the core detector. This analyzer is a three-electrode liquid analyzer typically used in boiler feed water applications. The HVAM system incorporates a dual-phase sample collection/transport method which simultaneously pulls ambient air samples containing hydrazine and a very dilute sulfuric acid solution (0.0001 M) down a length of 1/4 inch outside diameter (OD) tubing from a remote site to the analyzer. The hydrazine-laden dilute acid stream is separated from the air and the pH is adjusted by addition of a dilute caustic solution to a pH greater than 10.2 prior to analysis. Both the dilute acid and caustic used by the HVAM are continuously generated during system operation on an "as needed" basis by mixing a metered amount of concentrated acid/base with dilution water. All of the waste water generated by the analyzer is purified for reuse by Barnstead ion-exchange cartridges so that the entire system minimizes the generation of waste materials. The pumping of all liquid streams and mixing of the caustic solution and dilution water with the incoming sample are done by a single pump motor fitted with the appropriate mix of peristaltic pump heads. The signal to noise (S/N) ratio of the analyzer has been enhanced by adding a stirrer in the MDA liquid cell to provide mixing normally generated by the high liquid flow rate designed by the manufacturer. An onboard microprocessor continuously monitors liquid levels, sample vacuum, and liquid leak sensors, as well as handles communications and other system functions (such as shut down should system malfunctions or errors occur). The overall system response of the HVAM can be automatically checked at regular intervals by measuring the analyzer response to a metered amount of calibration standard injected into the dilute acid stream. The HVAM system provides two measurement ranges (threshold limit value (TLV): 10 to 1000 parts per billion (ppb)/LEAK: 100 ppb to 10 parts per million (ppm)). The LEAK range is created by dilution of the sulfuric acid/hydrazine liquid sample with pure water. This dual range capability permits the analyzer to quantify ambient air samples whose hydrazine concentrations range from 10 ppb to as high as 10 ppm. The laboratory and field prototypes have demonstrated total system response times on the order of 10 to 12 minutes for samples ranging from 10 to 900 ppb in the lLV mode and is greater than 2 minutes for samples ranging from 100 to 1300 ppb in the LEAK mode. Service intervals of over 3 months have been demonstrated for continuous 24 hour/day, 7 day/week usage. The HVAM is made up of a purged cabinet that contains power supplies, RS422 signal transmission capabilities, a UPS, an on-site warning system, and a Line Replaceable Unit (LRU). The LRU includes all of the liquid flow system, the analyzer, the control/data system microprocessor and assorted flow and liquid-level sensors. The LRU is mounted on a track slide system so it can be serviced inplace or totally removed and quickly exchanged with another calibrated unit, thus minimizing analyzer downtime. Once an LRU is removed from an analyzer enclosure, it can be brought to a laboratory facility for complete calibration and periodic maintenance.

Meneghelli, Barry↗

Stirling Engine Controller

Stirling technology is being developed to replace RTG s (Radioisotope Thermoelectric Generators), more specifically a stirling convertor, which is a stirling engine coupled to a linear alternator. Over the past three decades, the stirling engine has been designed to perform different functions. Stirling convertors have been designed to decrease fuel consumption in automobiles. They have also been designed for terrestrial and space applications. Currently NASA Glenn is using the convertor for space based applications. A stiring converter is a better means of power for deep space mission and "dusty" mission, like the Mars Rovers, than solar panels because it is not affected by dust. Spirit and Opportunity, two Mars rovers currently navigating the planet, are losing their ability to generate electricity because dust is collecting on their solar panels. Opportunity is losing more energy because its robotic arm has a heater with a switch that can not be turned off. The heater is not needed at night, but yet still runs. This generates a greater loss of electricity and in turn diminishes the performance of the rover. The stirling cycle has the potential to provide very efficient conversion of heat energy to electric a1 energy, more so than RTG's. The stirling engine converts the thermal energy produced by the decaying radioisotope to mechanical energy; the linear alternator converts this into electricity. convertor. Since the early 1990's tests have been performed to maximize the efficiency of the stirling converter. Many months, even years, are dedicated to preparing and performing tests. Currently, two stirling convertors #'s 13 and 14, which were developed by Stirling Technology Company, are on an extended operation test. As of June 7th, the two convertors reached 7,500 hours each of operation. Before the convertors could run unattended, many safety precautions had to be examined. So, special instrumentation and circuits were developed to detect off nominal conditions and also safely shutdown the engines. The test will last for a period of 8000 to 9000 hours. Other types of tests that have been performed are: performance mapping, controller development, launch environment, and vibration emissions testing. Currently, the thermo-mechanical system branch is housing a RG-350, a stirling convertor. The convertor was used in previous tests such as a Hall Thruster test, world s first integrated test of a dynamic power system with electric propulsion. Another test performed was to conclude if free piston stirling convertors can be synchronized for vibration balancing, with no thermodynamic or electrical connections and not cause both to shutdown if one failed. The ability to reduce vibration by synchronizing convertor operation but still be able to operate when one partner fails is pertinent in space and terrestrial applications. The convertor is now being brought back into operation and a controller is in the process of being developed. This convertor will be used as a testbed for new controllers. I worked with Mary Ellen Roth on the electric engineering aspects of the RG-350. My main goal was to enhance the data collection process. I worked on different aspects of the RG-350, with a main focus on the engine controller. I drew a schematic of the wire connections in the engine controller, using PCB Express, so that a plan could be devised to connect the power meter properly between the output of the engine and the engine controller. I measured the power using two different instruments: Valhalla Scientific power meter and Ohio Semitronics power measurement device. The convertor is connected to an Agilent 34970A Data Acquisition/Switch Unit, which allows the user to measure, record, and monitor voltage, current, frequency, and temperature. I assisted in preparing the Data Acquisition for general operation. I also helped test a panel of transducers, which will be placed in the rack that powers and monitors the convertor.

Blaze, Gina M.↗

Sensorimotor adaptations to microgravity in humans

Motor function is altered by microgravity, but little detail is available as to what these changes are and how changes in the individual components of the sensorimotor system affect the control of movement. Further, there is little information on whether the changes in motor performance reflect immediate or chronic adaptations to changing gravitational environments. To determine the effects of microgravity on the neural control properties of selected motor pools, four male astronauts from the NASA STS-78 mission performed motor tasks requiring the maintenance of either ankle dorsiflexor or plantarflexor torque. Torques of 10 or 50% of a maximal voluntary contraction (MVC) were requested of the subjects during 10 degrees peak-to-peak sinusoidal movements at 0.5 Hz. When 10% MVC of the plantarflexors was requested, the actual torques generated in-flight were similar to pre-flight values. Post-flight torques were higher than pre- and in-flight torques. The actual torques when 50% MVC was requested were higher in- and post-flight than pre-flight. Soleus (Sol) electromyographic (EMG) amplitudes during plantarflexion were higher in-flight than pre- or post-flight for both the 10 and 50% MVC tasks. No differences in medial gastrocnemius (MG) EMG amplitudes were observed for either the 10 or 50% MVC tasks. The EMG amplitudes of the tibialis anterior (TA), an antagonist to plantarflexion, were higher in- and post-flight than pre-flight for the 50% MVC task. During the dorsiflexion tasks, the torques generated in both the 10 and 50% MVC tasks did not differ pre-, in- and post-flight. TA EMG amplitudes were significantly higher in- than pre-flight for both the 10 or 50% MVC tasks, and remained elevated post-flight for the 50% MVC test. Both the Sol and MG EMG amplitudes were significantly higher in-flight than either pre- or post-flight for both the 10 and 50% MVC tests. These data suggest that the most consistent response to space flight was an elevation in the level of contractions of agonists and antagonists when attempting to maintain constant torques at a given level of MVC. Also, the chronic levels of EMG activity in selected ankle flexor and extensor muscles during space flight and during routine activities on Earth were recorded. Compared with pre- and post-flight values, there was a marked increase in the total EMG activity of the TA and the Sol and no change in the MG EMG activity in-flight. These data indicate that space flight, as occurs on shuttle missions, is a model of elevated activation of both flexor and extensor muscles, probably reflecting the effects of programmed work schedules in flight rather than a direct effect of microgravity.

NASA Experiment Number 284036↗