Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fringe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Implementation of a Wollaston interferometry diagnostic on OMEGA EP

Here, a Wollaston interferometer is presented for use in measuring the electron density of plasma plumes created in experiments on the OMEGA EP laser system. The diagnostic is installed as an additional arm on the 4ω probe system, a suite of diagnostics that share a 10 ps pulse of 263 nm laser light captured by an imaging system at f /4. The interferometer utilizes a Wollaston prism to create two angularly separated beams from a single input probe beam, split at any angle between 0° and 90°. This configuration is implemented uniquely such that fringe spacing may be altered independently of field of view, magnification, and imaging resolution, from a range of 17 to 76 μm/fringe. The region of overlap between the two beams forms a total field of view of approximately 1.2 × 1.6 mm at the target chamber center with an imaging resolution of 5 μm. Using this configuration, here it is shown that plasma density may be accurately characterized over a range of 3 × 10 18 –1 × 10 20 cm -3 .

47 OTHER INSTRUMENTATION↗

Laser calibration of the DIII-D coherence imaging system

Here, we describe an in situ calibration technique for Coherence Imaging Spectroscopy (CIS) that measures 2-D images of ion flows on DIII-D. A low power CW diode laser that is tuneable in the range 464-468 nm along with a precision wavemeter (10 –5 nm resolution) is used to characterize the interferometer phase as a function of wavelength in the region of C iii (465 nm) and He ii (468 nm). The interferometer is stabilized both mechanically and thermally to minimize drift during the calibration. Optical stirring and an integration sphere are utilized to obtain spatially uniform calibration images. The quality of the calibration data enables a measurement of phase versus wavelength over approximately 10 fringes of the interferometer. These coefficients can also be related to the geometry of the optics and the birefringent crystal of the interferometer. On DIII-D, the integration sphere with the laser light is inserted into the CIS optical system between shots and the laser image and wavelength are automatically recorded, providing a zero velocity reference

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray streaked refraction enhanced radiography for inferring inflight density gradients in ICF capsule implosions

In the quest for reaching ignition of deuterium-tritium (DT) fuel capsule implosions, experiments on the National Ignition Facility (NIF) have shown lower final fuel areal densities than simulated. Possible explanations for reduced compression are higher preheat that can increase the ablator-DT ice density jump and induce mix at that interface or reverberating shocks. We are hence developing x-ray Refraction Enhanced Radiography (RER) to infer the inflight density profiles in layered fuel capsule implosions. We use a 5 μm slit backlit by a Ni 7.8 keV He-α NIF laser driven x-ray source positioned at 20 mm from the capsule to cast refracted images of the inflight capsule onto a streak camera in a high magnification (M ~ 60×) setup. Our first experiments have validated our setup that recorded a streaked x-ray fringe pattern from an undriven high density carbon (HDC) capsule consistent with ray tracing calculations at the required ~6 μm and 25 ps resolution. Streaked RER was then applied to inflight layered HDC capsule implosions using a hydrogen-tritium fuel mix rather than DT to reduce neutron yields and associated backgrounds. The first RER of an imploding capsule revealed strong features associated with the ablation front and ice-ablator interface that are not visible in standard absorption radiographs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A broadband fiber-optic nonlinear interferometer

In this paper, we describe an all-fiber nonlinear interferometer based on four-wave mixing in highly nonlinear fiber. Our configuration realizes phase-sensitive interference with 97% peak visibility and >90% visibility over a broad 554 GHz optical band. By comparing the output noise power to the shot-noise level, we confirm noise cancellation at dark interference fringes, as required for quantum-enhanced sensitivity. Finally, our device extends nonlinear interferometry to the important platform of highly nonlinear optical fiber and could find applications in a variety of fiber-based sensors.

47 OTHER INSTRUMENTATION↗

Dispersion calibration for the National Ignition Facility electron–positron–proton spectrometers for intense laser matter interactions

Electron–positron pairs, produced in intense laser–solid interactions, are diagnosed using magnetic spectrometers with image plates, such as the National Ignition Facility Electron–Positron–Proton Spectrometers (EPPSs). Although modeling can help infer the quantitative value, the accuracy of the models needs to be verified to ensure measurement quality. The dispersion of low-energy electrons and positrons may be affected by fringe magnetic fields near the entrance of the EPPS. We have calibrated the EPPS with six electron beams from a Siemens Oncor linear accelerator (linac) ranging in energy from 2.7 MeV to 15.2 MeV as they enter the spectrometer. A Geant4 Tool for Particle Simulation Monte Carlo simulation was set up to match depth dose curves and lateral profiles measured in water at 100 cm source–surface distance. An accurate relationship was established between the bending magnet current setting and the energy of the electron beam at the exit window. The simulations and measurements were used to determine the energy distributions of the six electron beams at the EPPS slit. Furthermore, analysis of the scanned image plates together with the determined energy distribution arriving in the spectrometer provides improved dispersion curves for the EPPS.

47 OTHER INSTRUMENTATION↗

The inductively driven transmission line: A passively coupled device for diagnostic applications on the Z pulsed power facility

The inductively driven transmission line (IDTL) is a miniature current-carrying device that passively couples to fringe magnetic fields in the final power feed on the Z Pulsed Power Facility. The IDTL redirects a small amount of Z’s magnetic energy along a secondary path to ground, thereby enabling pulsed power diagnostics to be driven in parallel with the primary load for the first time. IDTL experiments and modeling presented here indicate that IDTLs operate non-perturbatively on Z and that they can draw in excess of 150 kA of secondary current, which is enough to drive an X-pinch backlighter. Further experiments show that IDTLs are also capable of making cleaner, higher-fidelity measurements of the current flowing in the final feed.

47 OTHER INSTRUMENTATION↗

Relaxation of a single defect spin by the low-frequency gyrotropic mode of a magnetic vortex

We excite the gyrotropic mode of a magnetic vortex and observe the resulting effect on the spin state of a nearby nitrogen-vacancy (NV) defect in diamond. Thin permalloy disks fabricated on a diamond sample are magnetized in a vortex state in which the magnetization curls around a central core. The magnetization dynamics of this configuration are described by a discrete spectrum of confined magnon modes as well as a low-frequency gyrotropic mode in which the vortex core precesses about its equilibrium position. Despite the spin transition frequencies being far-detuned from the modes of the ferromagnet, we observe enhanced relaxation of the NV spin when driving the gyrotropic mode. Moreover, we map the spatial dependence of the interaction between the vortex and the spin by translating the vortex core within the disk with an applied magnetic field, resulting in steplike motion as the vortex is pinned and de-pinned. Strong spin relaxation is observed when the vortex core is within approximately 250 nm of the NV center defect. We attribute this effect to the higher frequencies in the spectrum of the magnetic fringe field arising from the soliton-like nature of the gyrotropic mode when driven with sufficiently large amplitude.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The physical meaning of the magnetic scalar potential and its use in the design of hermetic electromagnetic coils

The magnetic scalar potential U(r⃗) has an intuitive physical interpretation, representing the electric current I = ΔU, which must be directed between any pair of isocontours along the boundary of a region, differing in potential by ΔU, in order to generate the corresponding magnetic intensity H⃗=−∇⃗U inside the region with no tangential component outside the boundary. This physical significance is exploited to invert the design process of hermetic (fringeless) electromagnetic coils from standard iterative techniques (calculating the magnetic field of refined current distributions) to a procedure for calculating the exact surface currents required to generate a given field configuration. A practical construction algorithm is given to produce the prescribed field in a “Target” region (constrained only by Maxwell’s equations) while confining the fringe field to a specified hermetic “Return” region. Example coils are analyzed along with a discussion of the limits of precision of the constructed field.

Crawford, C. B. (ORCID:0000000219324334)↗

Mitigation of breathing oscillations and focusing of the plume in a segmented electrode wall-less Hall thruster

We report in the absence of the channel walls bounding the plasma, a wall-less Hall thruster is a promising configuration with a potentially longer lifetime and easier scalability than conventional Hall thrusters. Because the ion acceleration takes place in the fringing magnetic field with a strong axial component, the operation of a typical wall-less thruster is characterized by a large beam divergence of the plasma flow, which reduces the thrust. In this work, the addition of a biased segmented electrode to the wall-less thruster is shown to significantly narrow the plasma plume and suppress large amplitude breathing oscillations of the discharge current commonly associated with ionization instability. Both effects result in improvements to the thruster performance. Physical mechanisms responsible for these effects are unclear, but they are apparently associated with the reduction of the electron cross field transport to the anode and a transition in the breathing mode frequency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantitative spatiotemporal density evolution of aluminum heated purely by monochromatic electrons

A spatially resolved air-wedge shearing interferometer and shadowgraph diagnostic provides measurements of electron density with a resolution of ∼40 μm. A ∼100-ns-long, monoenergetic electron bunch at 19.8 MeV and a current of 1.4 kA (8.5×1014 e−) heats 100-μm-thick aluminum (Al) foils in a 1-mm-spot to Te∼1 eV. A 5-ns-long, ∼60 mJ, frequency doubled Nd:YAG laser probes the dense Al plasma. Electron densities up to 1020cm−3 are resolved; the maximum resolvable density is limited by opacity, transmission, and spatial fringe density achievable with the detector. This diagnostic provides measurements of the total phase shift, transmission, and electron density. Several measurements at different time slices provide the ability to determine the velocity of the leading edge of the shadowgraph and compare it to the motion of different density shells. These measurements are also compared to radiation hydrodynamics simulations. A rough quantitative agreement is shown between the hydro simulations and the measurements; there are differences in the exact density distributions.

Coleman, J. E. (ORCID:0000000308873757)↗

Current advances on Talbot–Lau x-ray imaging diagnostics for high energy density experiments (invited)

Talbot–Lau x-ray interferometry is a refraction-based diagnostic that can map electron density gradients through phase-contrast methods. The Talbot–Lau x-ray deflectometry (TXD) diagnostics have been deployed in several high energy density experiments. To improve diagnostic performance, a monochromatic TXD was implemented on the Multi-Tera Watt (MTW) laser using 8 keV multilayer mirrors (Δθ/θ = 4.5%-5.6%). Copper foil and wire targets were irradiated at 10 14 –10 15 W/cm 2 . Laser pulse length (~10 to 80 ps) and backlighter target configurations were explored in the context of Moiré fringe contrast and spatial resolution. Foil and wire targets delivered increased contrast <30%. The best spatial resolution (<6 μm) was measured for foils irradiated 80° from the surface. Further TXD diagnostic capability enhancement was achieved through the development of advanced data postprocessing tools. The Talbot Interferometry Analysis (TIA) code enabled x-ray refraction measurements from the MTW monochromatic TXD. Additionally, phase, attenuation, and dark-field maps of an ablating x-pinch load were retrieved through TXD. The images show a dense wire core of ~60 μm diameter surrounded by low-density material of ~40 μm thickness with an outer diameter ratio of ~2.3. Attenuation at 8 keV was measured at ~20% for the dense core and ~10% for the low-density material. Instrumental and experimental limitations for monochromatic TXD diagnostics are presented. Enhanced postprocessing capabilities enabled by TIA are demonstrated in the context of high-intensity laser and pulsed power experimental data analysis. Significant advances in TXD diagnostic capabilities are presented. Furthermore, these results inform future diagnostic technique upgrades that will improve the accuracy of plasma characterization through TXD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Noise-specific beating in the higher-level Ramsey curves of a transmon qubit

We report: in the higher levels of superconducting transmon devices and more generally charge sensitive devices, T 2 * measurements made in the presence of low-frequency time-correlated 1/f charge noise and quasiparticle-induced parity flips can give an underestimation of the total dephasing time. The charge variations manifest as beating patterns observed in the overlay of several Ramsey fringe curves and are reproduced with a phenomenological Ramsey curve model, which accounts for the charge variations. T 2 * dephasing times, which more accurately represent the total dephasing time, are obtained. The phenomenological model is compared with a Lindblad master equation model. Both models are found to be in agreement with one another and the experimental data. Finally, the phenomenological formulation enables a simple method in which the power spectral density for the low-frequency noise can be inferred from the overlay of several Ramsey curves.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A variational method for the sheath potential of hypersonic leading edges with space-charge limitations

Electron transpiration cooling for the leading edges (LE) of hypersonic aircraft utilizes thermionic emission; however, space-charge effects limit the electron emission rate, potentially diminishing the efficiency of this cooling mechanism. We develop a variational weak form of the Poisson equation that describes the sheath potential and then numerically solve it using the finite element method. This formulation has two main benefits: (1) the space-charge limit condition can be incorporated as a constraint and (2) it allows for the analysis of three-dimensional geometries with complex boundary conditions. We demonstrate that the current emitted from the surface of an LE is generally a small fraction of the Child–Langmuir limit due to space charge. We then propose several methods to enhance the emitted current from the surface and to boost the cooling effect of thermionic emission. These include increasing the plasma density, applying a negative surface potential, and using fringe fields under suitable geometric conditions. For a LaB6 emitting LE, the total emitted current is shown to be minimal and independent of the temperature of a surface with floating potential. However, when a negative potential is applied and the surface is heated, the emitted current follows the Richardson–Dushman relationship up to a critical temperature, beyond which it remains constant. At an applied surface potential of −5 V, the critical temperature is around 1700 K.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Assessment of errors in analytic modeling of permanent magnet electron spectrometers for laser-plasma accelerators

Here, we assess the error in three treatments of a critical electron beam diagnostic for laser-plasma acceleration (LPA) experiments: a permanent magnet electron spectrometer. Since LPA electron spectrometers are often difficult to calibrate due to the scarcity of well-characterized, tunable electron beam sources in the appropriate energy range and the mechanical complexity of electron spectrometers, the standard of calibration is Hall probe measurements. We first compare the electron spectrometer performance between SIMION calculations and the Hall probe measurements. We find up to a 60% (<8%) error in determining the absolute energy for electrons below (above) 80 MeV when using the SIMION-modeled magnetic field vs the measured magnetic field due to SIMION overpredicting fringe field strength. The difference in spectrometer energy resolution is within ∼10% between the modeled and measured fields. We then assess a simple block model, which is commonly used. We find that the simple block model presented here sufficiently captures the predicted as-built spectrometer performance for any application provided that the user can tolerate uncertainties on absolute energy determination up to 5% and errors on energy resolution up to 1%.

Electromagnetic optics↗

Precision ultranarrow-linewidth resonance excitation (PURE) preparation of a molecular beam of nitric oxide molecules for inelastic scattering with argon

We recently reported a novel technique that utilizes narrow-linewidth lasers to selectively excite molecules into a pure quantum state with a well-resolved, tunable distribution of velocities [O. A. Krohn and D. W. Chandler, J. Phys. Chem. Lett. 15(50), 12455–12463 (2024)]. We refer to the preparation of molecules by this technique as precision ultranarrow-linewidth resonant excitation (PURE) preparation. Here, in this study, we pair this PURE preparation methodology with active frequency stabilization of the quantum cascade laser that drives the excitation. In doing so, highly velocity-resolved packets of molecules are possible, with the limitations of this velocity resolution set by the stability of the laser locking and the spectral linewidth of the transition. We show that side-of-fringe locking to a Doppler-broadened absorption spectrum of our target molecule is sufficiently stable for PURE preparation of molecules for long timescales (several hours) with highly resolved velocity spreads (σ < 3 m/s). To demonstrate the scientific utility of this new capability, we present differential cross sections from scattering between a neat molecular beam of argon and a velocity-selected beam of nitric oxide (NO) in a pure quantum state. We observe well-resolved quantum diffraction oscillations in the forward-scattered collisions as well as general trends consistent with prior characterized collisions of NO + Ar.

Krohn, Olivia A. [Sandia National Laboratories (SN↗

Coherent beam combining of pulsed fibre amplifiers with active phase control

Coherent beam combining of pulsed fibre lasers is a promising method for power scaling while simultaneously maintaining good beam quality. We propose and demonstrate a scalable architecture for coherent beam combining of all-fibre pulsed amplifiers with active phase control using the stochastic parallel gradient descent (SPGD) algorithm. A low-pass filter is introduced to eliminate the fluctuation of the metric function caused by pulsed lasers and to extract the exact phase noise signal. Active control is thereby based on the SPGD algorithm, resulting in stable coherent beam combining at the receiving plane even in a turbulent environment. Experimental results show that the fringe visibility of the long exposure pattern increases from 0 to 0.4, and the power encircled in the main-lobe increases by 1.6 times when the system evolves from the open-loop phase-locking scheme to the closed-loop scheme. This architecture can be easily scaled up to a higher power by increasing the number of amplifying channels and the power of a single amplifier.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Resonance enhancement of nonlinear photoluminescence in gallium selenide and related compounds

Maker fringe experiments on the layered chalcogenide semiconductor gallium selenide (GaSe) with weak cw diode lasers are presented. It is demonstrated that nonlinear photoluminescence emitted by this material and by the similar compound GaSe{sub 0.9}S{sub 0.1} under illumination with a 632.8-nm He - Ne laser shows very strong resonance enhancement upon heating when the absorption edge and exciton levels are shifted towards the laser line. The photoluminescence appears to be strongest when the energy level of the direct exciton, which emits it, is resonant with the photon energy of the laser. The previously observed enhancement of the photoluminescence by electric fields is interpreted in this context.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On the possibility of an experiment on 'nonlocality' of electrodynamics

It has been known since the 19th century that a circularly polarised electromagnetic wave carries an angular momentum. A simple experiment (Righi, 1882) apparently indicates that the angular momentum is distributed over the entire cross section of the beam. According to some modern ideas, the angular momentum of the beam with the given polarisation is localised near the beam 'surface' and represents a spin of photons, while the energy in the beam is distributed throughout its cross section, which is inconsistent with the principle of locality. For the experimental determination of the localisation of the angular momentum, we propose a new scheme, in which we study the interference pattern of two coherent circularly polarised beams. Each beam first passes through a half-wave plate, one of the plates being divided into two coaxial parts. With (manual) rotation of one parts of the plate we change the frequency of the light passing through it: the plate absorbs the momentum and, therefore, work is done. This change in frequency should cause a movement of the interference fringes and show the distribution of the angular momentum over the beam cross section. (light polarisation)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗