Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Study of Different Piezoelectric Material Stroke Displacement at Different Temperatures Using an SRF Cavity

Piezoelectric actuators are used for resonance control in superconducting linacs. The level of frequency compensation depends on the piezoelectric stroke displacement. In this study, the stroke displacement will be measured with a 1.3 GHz SRF cavity by measuring the frequency shift with respect to the voltage applied. The entire system was submerged in liquid helium. This study characterizes the PZT piezoelectric actuator (P-844K093) and a lithium niobate (P-844B0005) piezoelectric actuator. All these actuators were developed at Physik Instrumente (PI). The piezoelectric displacement was measured at different temperatures.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Global Precipitation Measurement Program and the Development of Dual-Frequency Precipitation Radar

The Global Precipitation Measurement (GPM) program is a mission to measure precipitation from space, and is a similar but much expanded mission of the Tropical Rainfall Measuring Mission. Its scope is not limited to scientific research, but includes practical and operational applications such as weather forecasting and water resource management. To meet the requirements of operational use, the GPM uses multiple low-orbiting satellites to increase the sampling frequency and to create three-hourly global rain maps that will be delivered to the world in quasi-real time. A dual-frequency radar (DPR) will be installed on the primary satellite that plays an important role in the whole mission. The DPR will realize measurement of precipitation with high sensitivity, high precision and high resolutions. This paper describes an outline of the GPM program, its issues and the roles and development of the DPR.

Iguchi, Toshio↗

A Brief Summary of Some of the Laboratory Astrophysics Workshop

Our present knowledge of the molecular universe has come primarily from radio observations [ I include here millimeter and submillimeter in this rubric]. There are a number of reasons for this but the primary one is the extremely high spectral resolution. The ease of observing emission from the volume of dense molecular clouds without significant attenuation by scattering from dust has shown this to be the powerful observational tool for molecular astronomy. Finally the relative simplicity of rotational compared to vibrational or electronic spectroscopy allows carrier identification as well as facile evaluation of cloud conditions such as density and temperature. These virtues become tenuous as the astronomical observations are pushed to higher frequencies for enhanced observational sensitivity. Thus precision rest frequencies are mandatory for the search for new species. We may inquire about which new species require particular attention, and which species may be relatively safely predicted on the basis of lower frequency laboratory measurements. For a rigid rotor the three rotational constants are sufficient to completely specify the transition frequencies. The intensities require the three components of the electric dipole moment. For semirigid species, where the centrifugal distortion, may be treated at the quartic level of angular momentum (Bunker et al. 1998), up to five additional constants are required (Watson 1967). There are a number of such species of considerable interest, where laboratory measurements are adequate for astronomical searches.

Klemperer, William↗

Parametric longitudinal coupling between a high-impedance superconducting resonator and a semiconductor quantum dot singlet-triplet spin qubit

Coupling qubits to a superconducting resonator provides a mechanism to enable long-distance entangling operations in a quantum computer based on spins in semiconducting materials. Here, we demonstrate a controllable spin-photon coupling based on a longitudinal interaction between a spin qubit and a resonator. We show that coupling a singlet-triplet qubit to a high-impedance superconducting resonator can produce the desired longitudinal coupling when the qubit is driven near the resonator’s frequency. We measure the energy splitting of the qubit as a function of the drive amplitude and frequency of a microwave signal applied near the resonator antinode, revealing pronounced effects close to the resonator frequency due to longitudinal coupling. By tuning the amplitude of the drive, we reach a regime with longitudinal coupling exceeding 1 MHz. This mechanism for qubit-resonator coupling represents a stepping stone towards producing high-fidelity two-qubit gates mediated by a superconducting resonator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-field/high-frequency electron spin resonances of Fe-doped β − Ga 2 O 3 by terahertz generalized ellipsometry: Monoclinic symmetry effects

We demonstrate detection and measurement of electron paramagnetic spin resonances (EPR) of iron defects in β − Ga 2 O 3 utilizing generalized ellipsometry at frequencies between 110 and 170 GHz. The experiments are performed on an Fe-doped single crystal in a free-beam configuration in reflection at 45 ∘ and magnetic fields between 3 and 7 T. In contrast with low-field, low-frequency EPR measurements, we observe all five transitions of the s = 5 / 2 high-spin state Fe 3 + simultaneously. We confirm that ferric Fe 3 + is predominantly found at octahedrally coordinated Ga sites. We obtain the full set of fourth-order monoclinic zero-field splitting parameters for both octahedrally and tetrahedrally coordinated sites by employing measurements at multiple sample azimuth rotations. The capability of high-field EPR allows us to demonstrate that simplified second-order orthorhombic spin Hamiltonians are insufficient, and fourth-order terms as well as consideration of the monoclinic symmetry are needed. These findings are supported by computational approaches based on density-functional theory for second-order and on ligand-field theory for fourth-order parameters of the spin Hamiltonian. Terahertz ellipsometry is a way to measure spin resonances in a cavity-free setup. Its possibility of varying the probe frequency arbitrarily without otherwise changing the experimental setup offers unique means of truly disentangling different components of highly anisotropic spin Hamiltonians. Published by the American Physical Society 2024

Materials Science↗

Performance and Stability Characteristics of a Uni-Element Swirl Injector for Oxygen-Rich Stage Combustion Cycles

A uni-element liquid propellant combustion performance and instability study for liquid RP-1 and hot oxygen-rich pre-burner products was conducted, at a chamber pressure of about 1000 psi. using flush and recessed swirl injectors. High-frequency pressure transducer measurements were analyzed to yield the characteristic frequencies which were compared to expected frequencies of the chamber. Modes, which were discovered to be present within the main chamber included, the first longitudinal, detected at approximately 1950 Hz, and the second longitudinal mode at approximately 3800 Hz. An additional first longitudinal quarter wave mode was measured at a frequency of approximately 23000 Hz for the recessed swirl injector configuration. The characteristic instabilities resulting from these experiments were relatively weak averaging 0.2% to 0.3% of the chamber pressure.

Pal, S.↗

An improved method to determine vibration damping of materials and structural components

The present, improved frequency-domain technique for vibration-damping estimation involves the fitting of a 'best curve' for the measured frequency-response data near a resonance by means of a least-squares error criterion. The damping ratio and the undamped natural frequency are then computed using the coefficients of the rational fraction polynomial that had been determined on the basis of the curve-fitting technique. Attention is given to the results of this method's application to damping measurements for graphite-reinforced epoxy composites. The results obtained are superior to those of the 'half-power points' method.

Rao, Mohan D.↗

nu-2 band of H2 O-16 - Line strengths and transition frequencies

High-resolution spectra of H2 O-16 were recorded with a Fourier-transform spectrometer covering transitions in the (010)-(000) band from 1066 to 2582/cm. The measured line frequencies were used along with additional data taken from studies at microwave and far-infrared frequencies in an analysis to obtain rotational energies of levels in the (000) and (010) states. Measurements of the line strengths were fitted by least squares to a model in which the dipole moment matrix elements were represented by as many as 19 expansion coefficients. The results produced computed line strength values that are in excellent agreement, on the average, with the 874 experimental transitions included in the analysis. These results provide a more accurate representation of the line positions and strengths for the (010)-(000) band than are currently available on the HITRAN absorption line parameter compilation.

Toth, Robert A.↗

Comparison of rainfall profiles retrieved from dual-frequency radar and from combined radar and passive microwave radiometric measurements

Precipitation profiles retrieved from a dual frequency X- and Ka-band radar and from an X-band radiometer are analyzed. Profiles from combined radar and microwave radiometer measurements are compared to those from dual frequency radar measurements to study the performance of the combined radar-radiometer retrievals. A method for the retrieval of rainfall rate profiles from attenuated radar returns and passive radiometric data is presented. The results suggest that the operation of a single frequency radar with multifrequency passive radiometers may provide cost-effective spaceborne measurements of global tropical rainfall distributions. The possible use of this methodology for the Tropical Rainfall Measuring Mission is considered.

Weinman, J. A.↗

Rotordynamic forces in labyrinth seals: Theory and experiment

A theoretical and experimental investigation of the aerodynamic forces generated by a single gland labyrinth seal executing a simultaneous spinning/whirling motion has been conducted. A lumped parameter model for a single gland seal with coupling to an upstream cavity with leakage is developed along with an appropriate solution technique. From this theory, it is shown that the presence of the upstream cavity can, in some cases, augment the cross-stiffness and direct damping by a factor of four. The parameters that govern the coupling are presented along with predictions on their influence. A simple uncoupled model is used to identify the mechanisms responsible for cross force generation. This reduced system is nondimensionalized and the physical significance of the reduced parameters is discussed. Closed form algebraic formulas are given for some simple limiting cases. It is also shown that the total cross-force predicted by the uncoupled model can be represented as the sum of an ideal component due to an inviscid flow with entry swirl and a viscous part due to the change in swirl created by friction inside the gland. The frequency dependent ideal part is solely responsible for the rotordynamic direct damping. The facility designed and built to measure these frequency dependent forces is described. Experimental data confirm the validity and usefulness of this ideal/viscous decomposition. A method for calculating the damping coefficients based on the force decomposition using only the static measurements is presented. Experimental results supporting the predicted cross force augmentation due to the effect of upstream coupling are presented.

Millsaps, Knox T.↗

Swept Frequency Laser Metrology System

A swept frequency laser ranging system having sub-micron accuracy that employs multiple common-path heterodyne interferometers, one coupled to a calibrated delay-line for use as an absolute reference for the ranging system. An exemplary embodiment uses two laser heterodyne interferometers to create two laser beams at two different frequencies to measure distance and motions of target(s). Heterodyne fringes generated from reflections off a reference fiducial X(sub R) and measurement (or target) fiducial X(sub M) are reflected back and are then detected by photodiodes. The measured phase changes Delta phi(sub R) and Delta phi (sub m) resulting from the laser frequency swept gives target position. The reference delay-line is the only absolute reference needed in the metrology system and this provides an ultra-stable reference and simple/economical system.

Zhao, Feng↗

Low Frequency 1/f Noise on QWIPs, nBn, and Superlattice Focal Plane Array

Noise Equivalent Difference Temperature (NE△T) is a standard performance metric for most infrared focal plane array (FPA) systems. The frequency bandwidth and range associated with NE△T is at high frequency and it does not describe the long time noise behavior or the very low frequency noise of the FPA. Very low frequency noise measurement requires data capture that takes longer time duration and sampling interval. This study investigates low frequency noise in QWIP, nBn and LWIR n-type Complementary Barrier Infrared Detector (CBIRD) FPAs. The corner frequencies are extracted from the power spectral density (PSD) as function of frequency. The peak wavelength, quantum efficiency of QWIP detector are 6.2 µm and 2 %, respectively. QWIP FPA has a mean NE△T ~ 25 mK at an operating temperature of 65 K and an integration time of 16 msec. The mean QWIP PSD plot shows a corner frequency of < 0.5 mHz. The nBn FPA with 4 µm cut off and quantum efficiency of 67 % has NE△T ~ 15.6 mK at an integration time ~ 7.52 msec and an operating temperature of 120 K. The nBn has corner frequency of > 50 mHz. Lastly the n-type CBIRD FPA with a 50% cutoff at 8.8 µm and quantum efficiency of ~ 50 % has an NE△T ~ 18.6 mK at an integration time of 1.86 msec and operating temperature 120 K. The superlattice FPA has a corner frequency ~ 10 mHz. The investigation of the tail on the NE△T histogram reveals that its origin is not accounted for entirely by the high noise current, but also it needs the inclusion of lower responsivity for some pixels.

Pepper, B.↗

Electric Motor Noise from Small Quadcopters: Source Characteristics - Part II

The increased interest in electric motors for propulsion systems has driven interest in quantifying the contribution of electric motor noise to the overall sound levels and possible human annoyance of the propulsion system. This work presents acoustic measurements of electric motors used for small quadcopters to quantify the sound produced by a number of outrunning motors with different types of controllers. Results are presented for loaded and unloaded motors as installed and uninstalled configurations. Motor resonance frequencies were measured and computed. Current probe measurements showed that the supply current from the controllers contained significant harmonic content for the conventional and sinewave controllers. Acoustic results showed motor noise is typically radiated at frequencies near the mode 2 vibration frequency at roughly 5000 Hz. Electric motor noise was evident in the spectra produced by many of the motor-controller combinations for motors loaded with propellers with levels often greater than those for the motor alone due to increase in the stator magnetic flux density with increased current. An installed configuration produced increases in acoustic radiation over that of the uninstalled motor in a frequency range near the mode 1 vibration frequency near 1200 Hz. A companion paper (Part I - Acoustic Measurements), focuses on source identification using a phased array and directivity characteristics for a baseline configuration.

Motor Resonance Frequencies↗

Sensing depths in frequency domain thermoreflectance

In this work, a method is developed to calculate the length into a sample to which a Frequency Domain Thermoreflectance (FDTR) measurement is sensitive. Sensing depth and sensing radius are defined as limiting cases for the spherically spreading FDTR measurement. A finite element model for FDTR measurements is developed in COMSOL multiphysics and used to calculate sensing depth and sensing radius for silicon and silicon dioxide samples for a variety of frequencies and laser spot sizes. The model is compared to experimental FDTR measurements. Design recommendations for sample thickness are made for experiments where semi-infinite sample depth is desirable. For measurements using a metal transducer layer, the recommended sample thickness is three thermal penetration depths, as calculated from the lowest measurement frequency.

36 MATERIALS SCIENCE↗

Precision timekeeping using a small passive hydrogen maser

The timekeeping ability of a prototype passive hydrogen maser which is a factor of 5 smaller in size, weight, and cost than any previously designed, was compared to UTC (NBS) based on 10 cesium frequency standards including a large primary standard, NBS-4. The frequency of the prototype was monitored as a function of source pressure, cavity temperature, microwave power, modulation width, and magnetic field. Based on these measurements, a frequency stability of better than 6 x 10 to the -15 power was expected, implying a timekeeping ability of order 0.5 ns/day. Measurements vs UTC(NBS) indicate a joint timekeeping a stability of order 1.2 ns/day. Simultaneous measurements made between NBS-4, UTC(6600), and the small passive me maser show peak to peak time variations of the small maser vs UTC(6600) was 10 ns for the full 32 days if the average rate and drift are considered. Frequency stability of the small prototype vs UTC (NBS) was to 1.1 x 10 to the -14th power for tau = 1 to 8 days.

Walls, F. L.↗

High Speed and High Spatial Density Parameter Measurement Using Fiber Optic Sensing Technology

The present invention is an improved fiber optic sensing system (FOSS) having the ability to provide both high spatial resolution and high frequency strain measurements. The inventive hybrid FOSS fiber combines sensors from high acquisition speed and low spatial resolution Wavelength-Division Multiplexing (WDM) systems and from low acquisition speed and high spatial resolution Optical Frequency Domain Reflection (OFDR) systems. Two unique light sources utilizing different wavelengths are coupled with the hybrid FOSS fiber to generate reflected data from both the WDM sensors and OFDR sensors operating on a single fiber optic cable without incurring interference from one another. The two data sets are then de-multiplexed for analysis, optionally with conventionally-available WDM and OFDR system analyzers.

Parker, Allen R. Jr.↗

Quantitative assessment of Distributed Acoustic Sensing at the Source Physics Experiment, Phase II

In this report, we assess the data recorded by a Distributed Acoustic Sensing (DAS) cable deployed during the Source Physics Experiment, Phase II (DAG) in comparison with the data recorded by nearby 4.5-Hz geophones. DAS is a novel recording method with unprecedented spatial resolution, but there are significant concerns around the data fidelity as the technology is ramped up to more common usage. Here we run a series of tests to quantify the similarity between DAS data and more conventional data and investigate cases where the higher spatial resolution of the DAS can provide new insights into the wavefield. These tests include 1D modeling with seismic refraction and bootstrap uncertainties, assessing the amplitude spectra with distance from the source, measuring the frequency dependent inter-station coherency, estimating time-dependent phase velocity with beamforming and semblance, and measuring the cross-correlation between the geophone and the particle velocity inferred from the DAS. In most cases, we find high similarity between the two datasets, but the higher spatial resolution of the DAS provides increased details and methods of estimating uncertainty.

47 OTHER INSTRUMENTATION↗