Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “filter optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

A PCR Based Microbial Monitoring Alternative Method of Detection and Identification of Microbes Aboard ISS

Previous research has shown that microorganisms and potential human pathogens have been detected on the International Space Station (ISS) with additional introduction of new microflora occurring with every exchange of crew or addition of equipment and supplies. These microbes are readily transferred between crew and subsystems (i.e. ECLSS, environmental control and life support systems). As this can be detrimental to astronaut health and optimal performance of ISS systems, monitoring of systems such as ECLSS to include identification of microbial contaminants could prevent adverse effects on human health and life support systems. Current monitoring on ISS is laborious and utilizes culture based methods followed by sample return to Earth for complete analysis. Future, long-distance spaceflight missions will require real-time monitoring capabilities that enable efficient and rapid assessments of the microbial environment allowing for expedited decisions and more targeted response to cope with anomalies. Polymerase chain reaction (PCR), a molecular microbial monitoring method was chosen and numerous PCR instruments investigated for their potential to perform in microgravity conditions. Using ISS as a test bed for PCR verification in microgravity will enable NASA to assess whether molecular based microbiological sensors may be components of reliable, closed-loop life support and habitation systems in spacecraft, enhancing infrastructure capabilities through increased efficiency, reliability, and time savings by enabling sample analysis on orbit. NASA selected the Water Monitoring Suite as one of the rapid spaceflight hardware demonstration activities utilizing a streamlined process to minimize the time required to fly experimental flight hardware. The RAZOR EX (BioFire Defense, Salt Lake City, UT) system was part of the water monitoring suite and is a commercial off-the-shelf (COTS) real-time PCR instrument designed for field work. The RAZOR EX was originally designed for Department of Defense (DoD) under a small business innovative research (SBIR) grant and is ruggedized, compact and provides a rapid, sample to answer in less than an hour. PCR assays using a fluorescent probe were optimized and spiked with known concentrations of DNA (Pseudomonas aeruginosa) ranging from 0.002 to 20 ng. PCR reagents were lyophilized and configured in customized pouches and tested for flight readiness. Three types of water were used to rehydrate the reagents and demonstrate the fidelity of the PCR reaction in microgravity. Molecular grade deionized water served as a control while filtered and unfiltered ISS potable water served to test for chemical or biological inhibitors. All three types were compared to parallel ground test results. Nine tests were run on ISS (3 of each water type) and the critical threshold cycle (Ct) was compared to parallel ground tests completed at Kennedy Space Center, FL and Johnson Space Center, TX. All concentrations of Pseudomonas aeruginosa DNA were detected. A comparison of the Ct produced in real time PCR indicated similarity between flight and ground samples. There appeared to be no significant difference between flight or ground PCR reactions or between any of the three water types. This testing demonstrated the ability to perform molecular testing during spaceflight operations with similar sensitivity. It will allow for future ground development of molecular protocols and minimize the need for spaceflight testing. Future testing will include development of additional targets including environmental and health related organisms.

Christina Khodadad↗

Development of the GeoNEX Level 2G Products: Exploiting the Diurnal Variability of TOA Reflectance in Atmospheric Correction

This study develops a new atmospheric correction algorithm to generate the Level 2G products, in particular the gap-filled Surface Reflectance at 10-minute time steps, for the Geostationary-NASA Earth Exchange (GeoNEX) project. The algorithm is based on the MODIS MAIAC (Multi-Angle Implementation of Atmospheric Correction) framework but with significant modifications to exploit angular/temporal information from the diurnal variability of the GeoNEX L1G TOA (Top-of-Atmosphere) reflectance. The algorithm starts by evaluating the roughness/smoothness of the diurnal time series of the TOA reflectance. Because rapid changes in TOA reflectance are generally caused by passing clouds or shadows, rough segments of the time series are automatically filtered out while the smooth segments are further tested for brightness and temperature to identify clear-sky and snow-free observations. Next the algorithm runs the MAIAC RTM (Radiative Transfer Model) to retrieve the Ross-Thick-Li-Sparse (RTLS) BRDF model parameters and the daily-mean atmospheric optical depth (AOD) that allow the RTM to optimally simulate the observed diurnal variability of clear-sky TOA reflectance. Once the initial RTLS parameters are retrieved after the algorithm’s burn-in period, they are used as the prior information to predict the AOD level for the next days, while the subsequent clear-sky observations are used to make necessary adjustments to the RTLS parameters in an continuous fashion. This “prediction-analysis” cycle is then iterated to process the full time series of the L1G data, skipping only total-cloudy days or when surface snow is detected. We tested the algorithm over a list of selected AERONET sites. The retrieved results (the daily mean AOD and the RTLS parameters) reasonably agree with the ground-based measurements. Importantly, the results indicate that the diurnal cycles of surface reflectance are continuous functions of the illumination-view geometry. Thus we can use the retrieved RTLS model to accurately fill in data gaps on partial cloudy days. Also, our algorithm is totally independent from the traditional approaches based on the use of spectral band ratios between the shortwave infrared (e.g., 2.2µm) and the visible (e.g., 0.47µm and 0.64µm) bands. Our results thus demonstrate that the high-frequent diurnal geostationary observations contain unique information that helps us improve atmospheric correction of remote sensing data.

GeoNEX↗

Estimation in nonlinear systems with transport delay.

The problem of estimation of state in nonlinear dynamical systems containing time delays is studied. The plant is specified by a set of nonlinear differential-difference equations. Observations are a nonlinear function of current and/or delayed states. Both contain additive disturbances. The criterion used for the optimal estimates is the integral of the weighted squared error. Using the theory of the calculus of variations, equations are developed for the estimation. They are first expressed in the form of a split boundary value problem, which is then converted to an initial value problem for on-line estimation. The result yields a sequential estimation scheme in which filtered and smoothed estimates are computed in a sequential manner. The applicability of the procedure is demonstrated by a practical example.

Stoller, R. L.↗

NASA Tech Briefs, April 2013

Topics covered include: Fully Integrated, Miniature, High-Frequency Flow Probe Utilizing MEMS Leadless SOI Technology; Nanoscale Surface Plasmonics Sensor With Nanofluidic Control; Advanced Dispersed Fringe Sensing Algorithm for Coarse Phasing Segmented Mirror Telescopes; Neural Network Back-Propagation Algorithm for Sensing Hypergols; Bulk Moisture and Salinity Sensor; Change-Based Satellite Monitoring Using Broad Coverage and Targetable Sensing; Circularly Polarized Microwave Antenna Element with Very Low Off-Axis Cross-Polarization; Ultra-Low Heat-Leak, High-Temperature Superconducting Current Leads for Space Applications; Flash Cracking Reactor for Waste Plastic Processing; An Automated Safe-to-Mate (ASTM) Tester; Wireless Chalcogenide Nanoionic-Based Radio-Frequency Switch; Compute Element and Interface Box for the Hazard Detection System; DOT Transmit Module; Composite Aerogel Multifoil Protective Shielding; Li-Ion Electrolytes with Improved Safety and Tolerance to High-Voltage Systems; Polymer-Reinforced, Non-Brittle, Lightweight Cryogenic Insulation; Controlled, Site-Specific Functionalization of Carbon Nanotubes with Diazonium Salts; Regenerable Sorbent for CO2 Removal; Sprayable Aerogel Bead Compositions With High Shear Flow Resistance and High Thermal Insulation Value; Lexan Linear Shaped Charge Holder with Magnets and Backing Plate; Robotic Ankle for Omnidirectional Rock Anchors; Wind, Wave, and Tidal Energy Without Power Conditioning; An Active Heater Control Concept to Meet IXO Type Mirror Module Thermal-Structural Distortion Requirement; Waterless Clothes-Cleaning Machine; Integrated Electrical Wire Insulation Repair System; LVGEMS Time-of-Flight Mass Spectrometry on Satellites; Surface Inspection Tool for Optical Detection of Surface Defects; Per-Pixel, Dual-Counter Scheme for Optical Communications; Certification-Based Process Analysis; Surface Navigation Using Optimized Waypoints and Particle Swarm Optimization; Smart-Divert Powered Descent Guidance to Avoid the Backshell Landing Dispersion Ellipse; Estimating Foreign-Object-Debris Density from Photogrammetry Data; Adaptive Sampling of Spatiotemporal Phenomena with Optimization Criteria; Building a 2.5D Digital Elevation Model From 2D Imagery; Eyes on the Earth 3D; Target Trailing With Safe Navigation for Maritime Autonomous Surface Vehicles; Adams-Based Rover Terramechanics and Mobility Simulator - ARTEMIS; ISTP CDF Skeleton Editor; Uplink Summary Generator (ULSGEN) Version 1.0; Robotics On-Board Trainer (ROBoT); Software Engineering Tools for Scientific Models; Automatic Data Filter Customization Using a Genetic Algorithm; Tracker Toolkit; Towards Efficient Scientific Data Management Using Cloud Storage; On a Formal Tool for Reasoning About Flight Software Cost Analysis; A Nanostructured Composites Thermal Switch Controls Internal and External Short Circuit in Lithium Ion Batteries; Spacecraft Crew Cabin Condensation Control; and Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex.

Source record↗

Optimizing environmental conditions for mass application of mechano-dwarfing stimuli to Arabidopsis

Obtaining uniform mechano-dwarfing of Arabidopsis thaliana (L.) Heynh. seedlings within dense plantings is problematic. Alternative forms of mechano-stimulation were applied to seedlings in effort to obtain uniform growth reduction compared with undisturbed controls in both greenhouse and controlled growth environments. Arabidopsis grown under low photosynthetic photon flux (PPF) artificial light grew upright with limited leaf expansion, which enhanced mechano-responsiveness compared to that of rosette-growing plants under filtered sunlight or high PPF artificial light. Hypocotyls of seedlings grown at PPFs > 60 micromoles m-2 s-1 elongated less and had 6% less sensitivity to mechanical stress than seedlings grown at PPFs < 60 micromoles m-2 s-1. Fluorescent lamps alone (F) or fluorescent plus incandescent (F+I) lamps were compared for seedling responses to mechanical stress. Under F lighting, hypocotyl elongation was reduced 25% to 40% by twice-daily brush or plate treatments, and brushed seedlings exhibited more growth reduction than did plate treatments. Seedlings grown under F+I lamps exhibited similar stress-induced growth reduction compared to seedlings grown under F only, but stressed F+I seedlings lodged to a greater extent due to excessive hypocotyl elongation. Temperature-response studies using standardized F-only lighting indicated increased hypocotyl elongation but decreased leaf expansion, and decreased mechano-responsivity to brushing over the temperature range from 20 to 28 degrees C. Daylength studies indicated similar degrees of mechano-inhibition of hypocotyl elongation over the daylength range of 12, 16, 20, and 24 hours, whereas fresh weight of stressed seedling shoots declined compared to controls. A combination of environmental growth parameters that give repeatable, visual mechanical dwarfing of Arabidopsis include low-PPF fluorescent lighting from 55 to 60 micromoles m-2 s-1, ambient temperatures from 22 to 25 degrees C, and twice-daily brush treatments.

NASA Discipline Life Support Systems↗

Post Launch Calibration and Testing of the Geostationary Lightning Mapper on GOES-R Satellite

The Geostationary Operational Environmental Satellite R (GOES-R) series is the planned next generation of operational weather satellites for the United States National Oceanic and Atmospheric Administration (NOAA). The National Aeronautics and Space Administration (NASA) is procuring the GOES-R spacecraft and instruments with the first launch of the GOES-R series planned for October 2016. Included in the GOES-R Instrument suite is the Geostationary Lightning Mapper (GLM). GLM is a single-channel, near-infrared optical detector that can sense extremely brief (800 s) transient changes in the atmosphere, indicating the presence of lightning. GLM will measure total lightning activity continuously over the Americas and adjacent ocean regions with near-uniform spatial resolution of approximately 10 km. Due to its large CCD (1372x1300 pixels), high frame rate, sensitivity and onboard event filtering, GLM will require extensive post launch characterization and calibration. Daytime and nighttime images will be used to characterize both image quality criteria inherent to GLM as a space-based optic system (focus, stray light, crosstalk, solar glint) and programmable image processing criteria (dark offsets, gain, noise, linearity, dynamic range). In addition ground data filtering will be adjusted based on lightning-specific phenomenology (coherence) to isolate real from false transients with their own characteristics. These parameters will be updated, as needed, on orbit in an iterative process guided by pre-launch testing. This paper discusses the planned tests to be performed on GLM over the six-month Post Launch Test period to optimize and demonstrate GLM performance.

validation↗

Post Launch Calibration and Testing of the Geostationary Lightning Mapper on the GOES-R Satellite

The Geostationary Operational Environmental Satellite R (GOES-R) series is the planned next generation of operational weather satellites for the United States National Oceanic and Atmospheric Administration (NOAA). The National Aeronautics and Space Administration (NASA) is procuring the GOES-R spacecraft and instruments with the first launch of the GOES-R series planned for October 2016. Included in the GOES-R Instrument suite is the Geostationary Lightning Mapper (GLM). GLM is a single-channel, near-infrared optical detector that can sense extremely brief (800 microseconds) transient changes in the atmosphere, indicating the presence of lightning. GLM will measure total lightning activity continuously over the Americas and adjacent ocean regions with near-uniform spatial resolution of approximately 10 km. Due to its large CCD (1372x1300 pixels), high frame rate, sensitivity and onboard event filtering, GLM will require extensive post launch characterization and calibration. Daytime and nighttime images will be used to characterize both image quality criteria inherent to GLM as a space-based optic system (focus, stray light, crosstalk, solar glint) and programmable image processing criteria (dark offsets, gain, noise, linearity, dynamic range). In addition ground data filtering will be adjusted based on lightning-specific phenomenology (coherence) to isolate real from false transients with their own characteristics. These parameters will be updated, as needed, on orbit in an iterative process guided by pre-launch testing. This paper discusses the planned tests to be performed on GLM over the six-month Post Launch Test period to optimize and demonstrate GLM performance.

validation↗

Description of real-time Ada software implementation of a power system monitor for the Space Station Freedom PMAD DC testbed

The Ada language software development to perform the electrical system monitoring functions for the NASA Lewis Research Center's Power Management and Distribution (PMAD) DC testbed is described. The results of the effort to implement this monitor are presented. The PMAD DC testbed is a reduced-scale prototype of the electrical power system to be used in the Space Station Freedom. The power is controlled by smart switches known as power control components (or switchgear). The power control components are currently coordinated by five Compaq 382/20e computers connected through an 802.4 local area network. One of these computers is designated as the control node with the other four acting as subsidiary controllers. The subsidiary controllers are connected to the power control components with a Mil-Std-1553 network. An operator interface is supplied by adding a sixth computer. The power system monitor algorithm is comprised of several functions including: periodic data acquisition, data smoothing, system performance analysis, and status reporting. Data is collected from the switchgear sensors every 100 milliseconds, then passed through a 2 Hz digital filter. System performance analysis includes power interruption and overcurrent detection. The reporting mechanism notifies an operator of any abnormalities in the system. Once per second, the system monitor provides data to the control node for further processing, such as state estimation. The system monitor required a hardware time interrupt to activate the data acquisition function. The execution time of the code was optimized using an assembly language routine. The routine allows direct vectoring of the processor to Ada language procedures that perform periodic control activities. A summary of the advantages and side effects of this technique are discussed.

Ludwig, Kimberly↗

Filtering algorithms for processing prefiltered measurements

The filtering algorithm for processing integral measurements is extended to include analog type prefilters with infinite memory, and to include sequential processing of prefiltered data in multi-sensor, multi-sample rate systems. The extension to infinite memory prefilters requires serial decorrelation of the prefilter output prior to state estimation. These algorithms provide a technique for investigation of prefilter parameter sensitivities, and provide optimal compensation for any information loss due to prefiltering.

Warren, A. W.↗

Stratospheric Assimilation of Chemical Tracer Observations Using a Kalman Filter: Chi-Square Validated Results and Analysis of Variance and Correlation Dynamics - Pt. 2

A Kalman filter system designed for the assimilation of limb-sounding observations of stratospheric chemical tracers, which has four tunable covariance parameters, was developed in Part I (Menard et al. 1998) The assimilation results of CH4 observations from the Cryogenic Limb Array Etalon Sounder instrument (CLAES) and the Halogen Observation Experiment instrument (HALOE) on board of the Upper Atmosphere Research Satellite are described in this paper. A robust (chi)(sup 2) criterion, which provides a statistical validation of the forecast and observational error covariances, was used to estimate the tunable variance parameters of the system. In particular, an estimate of the model error variance was obtained. The effect of model error on the forecast error variance became critical after only three days of assimilation of CLAES observations, although it took 14 days of forecast to double the initial error variance. We further found that the model error due to numerical discretization as arising in the standard Kalman filter algorithm, is comparable in size to the physical model error due to wind and transport modeling errors together. Separate assimilations of CLAES and HALOE observations were compared to validate the state estimate away from the observed locations. A wave-breaking event that took place several thousands of kilometers away from the HALOE observation locations was well captured by the Kalman filter due to highly anisotropic forecast error correlations. The forecast error correlation in the assimilation of the CLAES observations was found to have a structure similar to that in pure forecast mode except for smaller length scales. Finally, we have conducted an analysis of the variance and correlation dynamics to determine their relative importance in chemical tracer assimilation problems. Results show that the optimality of a tracer assimilation system depends, for the most part, on having flow-dependent error correlation rather than on evolving the error variance.

Menard, Richard↗

Bilinear modeling and nonlinear estimation

New methods are illustrated for online nonlinear estimation applied to the lateral deflection of an elastic beam on board measurements of angular rates and angular accelerations. The development of the filter equations, together with practical issues of their numerical solution as developed from global linearization by nonlinear output injection are contrasted with the usual method of the extended Kalman filter (EKF). It is shown how nonlinear estimation due to gyroscopic coupling can be implemented as an adaptive covariance filter using off-the-shelf Kalman filter algorithms. The effect of the global linearization by nonlinear output injection is to introduce a change of coordinates in which only the process noise covariance is to be updated in online implementation. This is in contrast to the computational approach which arises in EKF methods arising by local linearization with respect to the current conditional mean. Processing refinements for nonlinear estimation based on optimal, nonlinear interpolation between observations are also highlighted. In these methods the extrapolation of the process dynamics between measurement updates is obtained by replacing a transition matrix with an operator spline that is optimized off-line from responses to selected test inputs.

Dwyer, Thomas A. W., III↗

Data Mining and Optimization Tools for Developing Engine Parameters Tools

This project was awarded for understanding the problem and developing a plan for Data Mining tools for use in designing and implementing an Engine Condition Monitoring System. From the total budget of $5,000, Tricia and I studied the problem domain for developing ail Engine Condition Monitoring system using the sparse and non-standardized datasets to be available through a consortium at NASA Lewis Research Center. We visited NASA three times to discuss additional issues related to dataset which was not made available to us. We discussed and developed a general framework of data mining and optimization tools to extract useful information from sparse and non-standard datasets. These discussions lead to the training of Tricia Erhardt to develop Genetic Algorithm based search programs which were written in C++ and used to demonstrate the capability of GA algorithm in searching an optimal solution in noisy datasets. From the study and discussion with NASA LERC personnel, we then prepared a proposal, which is being submitted to NASA for future work for the development of data mining algorithms for engine conditional monitoring. The proposed set of algorithm uses wavelet processing for creating multi-resolution pyramid of the data for GA based multi-resolution optimal search. Wavelet processing is proposed to create a coarse resolution representation of data providing two advantages in GA based search: 1. We will have less data to begin with to make search sub-spaces. 2. It will have robustness against the noise because at every level of wavelet based decomposition, we will be decomposing the signal into low pass and high pass filters.

Dhawan, Atam P.↗

Circuit for Driving Piezoelectric Transducers

The figure schematically depicts an oscillator circuit for driving a piezoelectric transducer to excite vibrations in a mechanical structure. The circuit was designed and built to satisfy application-specific requirements to drive a selected one of 16 such transducers at a regulated amplitude and frequency chosen to optimize the amount of work performed by the transducer and to compensate for both (1) temporal variations of the resonance frequency and damping time of each transducer and (2) initially unknown differences among the resonance frequencies and damping times of different transducers. In other words, the circuit is designed to adjust itself to optimize the performance of whichever transducer is selected at any given time. The basic design concept may be adaptable to other applications that involve the use of piezoelectric transducers in ultrasonic cleaners and other apparatuses in which high-frequency mechanical drives are utilized. This circuit includes three resistor-capacitor networks that, together with the selected piezoelectric transducer, constitute a band-pass filter having a peak response at a frequency of about 2 kHz, which is approximately the resonance frequency of the piezoelectric transducers. Gain for generating oscillations is provided by a power hybrid operational amplifier (U1). A junction field-effect transistor (Q1) in combination with a resistor (R4) is used as a voltage-variable resistor to control the magnitude of the oscillation. The voltage-variable resistor is part of a feedback control loop: Part of the output of the oscillator is rectified and filtered for use as a slow negative feedback to the gate of Q1 to keep the output amplitude constant. The response of this control loop is much slower than 2 kHz and, therefore, does not introduce significant distortion of the oscillator output, which is a fairly clean sine wave. The positive AC feedback needed to sustain oscillations is derived from sampling the current through the piezoelectric transducer. This positive AC feedback, in combination with the slow feedback to the voltage-variable resistors, causes the overall loop gain to be just large enough to keep the oscillator running. The positive feedback loop includes two 16-channel multiplexers, which are not shown in the figure. One multiplexer is used to select the desired piezoelectric transducer. The other multiplexer, which is provided for use in the event that there are significant differences among the damping times of the 16 piezoelectric transducers, facilitates changing the value of one of the resistors in the positive-feedback loop to accommodate the damping time of the selected transducer.

Randall, David P.↗

Graphene-Based Filtration Media for Spacecraft Potable Water Systems: An Early Investigation

Graphene-based materials have allowed fundamental advances in fields such as energy storage, electronics development, material science, optics, medicine, and water processing due to their unique two-dimensional structure, mechanical robustness, large surface, and high conductivity. However, little to no effort has been devoted to exploiting and studying these materials to develop new water technologies suited for spacecraft applications. One such application is the potential use of graphene-based materials as filtration media for reclaimed water. Therefore, studying the adsorptive performance of these new materials becomes crucial in identifying the opportunity to replace/upgrade state-of-the-art filtration media currently used in space vehicles with water recovery capability; especially if consumable requirements can be lessened as a result of extended filtration capacity. This early Life-Support-Systems investigation pioneers in graphene research by testing a number of graphene-based materials in comparative adsorption and antimicrobial experiments where contaminant removal efficiency, maximum adsorption capacity, and bacterial reduction are probed. This preliminary investigation informs on the practicality of using graphene-based materials as filtration media and provides a discussion on the scaling-up and optimization of this prospective filtration technology for spacecraft potable water systems.

graphene↗

International Conference on Advances in Communication and Control Systems, 1st, Washington, DC, June 18-20, 1987, Proceedings

Theoretical models of communication and control systems are discussed in reviews and reports. Topics addressed include smoothing and identification for random fields, the information and coding capacities of mismatched Gaussian channels, recursive least-squares estimation and Kalman filtering by systolic arrays, Kemp echo digital filters, a periodic test-scheduling scheme for communication and queuing processes, and receivers for direct-sequence systems. Consideration is given to a distributed-parameter model for detecting cracks in rotors, active control of aeroelastic systems governed by functional differential equations, robust multivariable control of large space structures, finite-rank relatively bounded perturbations of semigroup generators, and sensitivity analysis of convex optimal-control problems.

Declaris, Nicholas↗

Interferometers adaptations to lidars

To perform daytime measurements of the density and temperature by Rayleigh lidar, it is necessary to select the wavelength with a very narrow spectral system. This filter is composed by an interference filter and a Fabry Perot etalon. The Fabry Perot etalon is the more performent compound, and it is necessary to build a specific optic around it. The image of the entrance pupil or the field diaphragm is at the infinite and the other diaphragm is on the etalon. The optical quality of the optical system is linked to the spectral resolution of the system to optimize the reduction of the field of view. The resolution is given by the formula: R = 8(xD/Fd)exp 2 where R = lambda/delta(lambda), x = diameter of the field diaphragm, D = diameter of the reception mirror, F = focal length of the telescope, and d = useful diameter of the etalon. In the Doppler Rayleigh lidars, the PF interferometer is the main part of the experiment and the exact spectral adaptation is the most critical problem. In the spectral adaptation of interferometers, the transmittance of the system will be acceptable if the etalon is exactly adjusted to the wavelength of the laser. It is necessary to work with a monomode laser, and adjust the shift to the bandpass of the interferometer. We are working with an interferometer built with molecular optical contact. This interferometer is put in a special pressure closed chamber.

Porteneuve, J.↗

Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex

Functional near infrared spectroscopy (fNIRS) is an emerging optical neuroimaging technology that indirectly measures neuronal activity in the cortex via neurovascular coupling. It quantifies hemoglobin concentration ([Hb]) and thus measures the same hemodynamic response as functional magnetic resonance imaging (fMRI), but is portable, non-confining, relatively inexpensive, and is appropriate for long-duration monitoring and use at the bedside. Like fMRI, it is noninvasive and safe for repeated measurements. Patterns of [Hb] changes are used to classify cognitive state. Thus, fNIRS technology offers much potential for application in operational contexts. For instance, the use of fNIRS to detect the mental state of commercial aircraft operators in near real time could allow intelligent flight decks of the future to optimally support human performance in the interest of safety by responding to hazardous mental states of the operator. However, many opportunities remain for improving robustness and reliability. It is desirable to reduce the impact of motion and poor optical coupling of probes to the skin. Such artifacts degrade signal quality and thus cognitive state classification accuracy. Field application calls for further development of algorithms and filters for the automation of bad channel detection and dynamic artifact removal. This work introduces a novel adaptive filter method for automated real-time fNIRS signal quality detection and improvement. The output signal (after filtering) will have had contributions from motion and poor coupling reduced or removed, thus leaving a signal more indicative of changes due to hemodynamic brain activations of interest. Cognitive state classifications based on these signals reflect brain activity more reliably. The filter has been tested successfully with both synthetic and real human subject data, and requires no auxiliary measurement. This method could be implemented as a real-time filtering option or bad channel rejection feature of software used with frequency domain fNIRS instruments for signal acquisition and processing. Use of this method could improve the reliability of any operational or real-world application of fNIRS in which motion is an inherent part of the functional task of interest. Other optical diagnostic techniques (e.g., for NIR medical diagnosis) also may benefit from the reduction of probe motion artifact during any use in which motion avoidance would be impractical or limit usability.

Harrivel, Angela↗

Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex

Functional near infrared spectroscopy (fNIRS) is an emerging optical neuroimaging technology that indirectly measures neuronal activity in the cortex via neurovascular coupling. It quantifies hemoglobin concentration ([Hb]) and thus measures the same hemodynamic response as functional magnetic resonance imaging (fMRI), but is portable, non-confining, relatively inexpensive, and is appropriate for long-duration monitoring and use at the bedside. Like fMRI, it is noninvasive and safe for repeated measurements. Patterns of [Hb] changes are used to classify cognitive state. Thus, fNIRS technology offers much potential for application in operational contexts. For instance, the use of fNIRS to detect the mental state of commercial aircraft operators in near real time could allow intelligent flight decks of the future to optimally support human performance in the interest of safety by responding to hazardous mental states of the operator. However, many opportunities remain for improving robustness and reliability. It is desirable to reduce the impact of motion and poor optical coupling of probes to the skin. Such artifacts degrade signal quality and thus cognitive state classification accuracy. Field application calls for further development of algorithms and filters for the automation of bad channel detection and dynamic artifact removal. This work introduces a novel adaptive filter method for automated real-time fNIRS signal quality detection and improvement. The output signal (after filtering) will have had contributions from motion and poor coupling reduced or removed, thus leaving a signal more indicative of changes due to hemodynamic brain activations of interest. Cognitive state classifications based on these signals reflect brain activity more reliably. The filter has been tested successfully with both synthetic and real human subject data, and requires no auxiliary measurement. This method could be implemented as a real-time filtering option or bad channel rejection feature of software used with frequency domain fNIRS instruments for signal acquisition and processing. Use of this method could improve the reliability of any operational or real-world application of fNIRS in which motion is an inherent part of the functional task of interest. Other optical diagnostic techniques (e.g., for NIR medical diagnosis) also may benefit from the reduction of probe motion artifact during any use in which motion avoidance would be impractical or limit usability.

Harrivel, Angela↗