Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fan efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Reinforcement learning for bluff body active flow control in experiments and simulations

Significance Reinforcement learning (RL) has been applied effectively in games and robotic manipulation. We demonstrate the effectiveness of RL in experimental fluid mechanics by applying it to reduce the drag of circular cylinders in turbulent flow, a canonical fluid–structure interaction problem. Although physics agnostic, RL managed to reduce the drag by 30 % or reach another specified optimum point very quickly. Following this discovery, we used high-fidelity simulations to probe the underlying physical mechanisms so that the discovered control techniques can be generalized to other similar flow problems. More broadly, RL-guided active control can lead to efficient exploration of additional flow-control strategies in experimental fluid mechanics, potentially paving the way for accelerating scientific discovery and different designs in flow-related engineering problems.

42 ENGINEERING↗

Optimizing the Internal Cell Structure of the Radon Monitor Based on Electrostatic Collection Method

Abstract As Rn-222 decays, an alpha particle is emitted and the residual polonium nucleus recoils in the opposite direction. At the end of the recoil path, 88% of the polonium atoms have a positive charge and 12% are neutral. The electric potential distribution in the 60 ml hemispherical internal cell of the radon monitor based on electrostatic collection is studied for reducing the combined probability of the positively charged Po-218 and the OH− produced by the ionization of water vapour in the air. The COMSOL software is used to simulate the electric potential distribution in the internal cell of the radon monitor based on the electrostatic collection method at 27°C, a pressure of 0.1 Mpa. For improving the collection efficiency of Po-218 ions, the average collection time along vertical and oblique lines is calculated when the upper surface of the internal cell is plastic, uncharged metal and charged metal, respectively. Assuming that the gas in the internal cell is uniformly distributed, the results show that if the upper surface of the hemispherical internal cell is plastic or uncharged metal, the electric potential formed in the internal cell is more uniform, and it is beneficial to reduce the total collection time of the positively charged Po-218 ions, thereby improving collection efficiency. The simulation results can be used as an effective reference for optimizing the design of the internal cell structure of the radon monitor based on electrostatic collection method.

Fan, Zhongkai (ORCID:0000000181247459)↗

MAESTROeX: A Massively Parallel Low Mach Number Astrophysical Solver

MAESTROeX is a massively parallel, finite-volume C++/F90 solver for low Mach number astrophysical flows. Our code utilizes a low Mach number equation set allowing for more efficient, long-time integration of highly subsonic flows compared to compressible approaches. The recommended range of applicability is for flows where the Mach number does not exceed ~0.1.

79 ASTRONOMY AND ASTROPHYSICS↗

Energy Demands and Efficiency Strategies in Data Center Buildings

Information technology (IT) is becoming increasingly pervasive throughout society as more data is digitally processed, stored, and transferred. The infrastructure that supports IT activity is growing accordingly, and data center energy demands haveincreased by nearly a factor of four over the past decade. Data centers house IT equipment and require significantly more energy to operate per unit floor area thanconventional buildings. The economic and environmental ramifications of continued data center growth motivate the need to explore energy-efficient methods to operate these buildings. A substantial portion of data center energy use is dedicated to removing the heat that is generated by the IT equipment. Using economizers to introduce large airflow rates of outside air during favorable weather could substantially reduce the energy consumption of data center cooling. Cooling buildings with economizers is an established energy saving measure, but in data centers this strategy is not widely used, partly owing to concerns that the large airflow rates would lead to increased indoor levels of airborne particles, which could damage IT equipment. The environmental conditions typical of data centers and the associated potential for equipment failure, however, are not well characterized. This barrier to economizer implementation illustrates the general relationship between energy use and indoor air quality in building design and operation. This dissertation investigates how building design and operation influence energy use and indoor air quality in data centers and provides strategies to improve both design goals simultaneously.As an initial step toward understanding data center air quality, measurements of particle concentrations were made at multiple operating northern California data centers. Ratios of measured particle concentrations in conventional data centers to the corresponding outside concentrations were significantly lower than those reported in the literature for office or residential buildings. Estimates using a material-balance model match well with empirical results, indicating that the dominant particle sources and losses -- ventilation and filtration -- have been characterized. Measurements taken at a data center using economizers show nearly an order of magnitude increase in particle concentration during economizer activity. However, even with the increase, themeasured particle concentrations are still below concentration limits recommended in most industry standards. The research proceeds by exploring the feasibility of using economizers in data centers while simultaneously controlling particle concentrations with high-quality air filtration. Physical and chemical properties of indoor and outdoor particles were analyzed at a data center using economizers and varying levels of air filtration efficiency. Results show that when improved filtration is used in combination with an economizer, the indoor/outdoor concentration ratios for most measured particle types were similar to the measurements when using conventional filtration without economizers. An energy analysis of the data center reveals that, even during the summer months, chiller savings from economizer use greatly outweigh the increase in fan power associated with improved filtration. These findings indicate that economizer use combined with improved filtration couldsignificantly reduce data center energy demand while providing a level of protection from particles of outdoor origin similar to that observed with conventional design. The emphasis of the dissertation then shifts to evaluate the energy benefits of economizer use in data centers under different design strategies. Economizer use with high ventilation rates is compared against an alternative, water-side economizer design that does not affect indoor particle concentrations. Building energy models are employed to estimate energy savings of both economizer designs for data centers in

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advanced Rooftop Control (ARC) Retrofit: Field-Test Results

The multi-year research study was initiated to find solutions to improve packaged equipment operating efficiency in the field. Pacific Northwest National Laboratory (PNNL), with funding from the U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) and Bonneville Power Administration (BPA) conducted this research, development and demonstration (RD&D) study. Packaged equipment with constant speed supply fans is designed to provide ventilation at the design rate at all times when the fan is operating as required by building code. Although there are a number of hours during the day when a building may not be fully occupied or the need for ventilation is lower than designed, the ventilation rate cannot be adjusted easily with a constant speed fan. Therefore, modulating the supply fan in conjunction with demand controlled ventilation (DCV) will not only reduce the coil energy but also reduce the fan energy. The objective of this multi-year research, development and demonstration project was to determine the magnitude of energy savings achievable by retrofitting existing packaged rooftop air conditioners with advanced control strategies not ordinarily used for packaged units. First, through detailed simulation analysis, it was shown that significant energy (between 24% and 35%) and cost savings (38%) from fan, cooling and heating energy consumption could be realized when packaged air conditioning units with gas furnaces are retrofitted with advanced control packages (combining multi-speed fan control, integrated economizer controls and DCV). The simulation analysis also showed significant savings for heat pumps (between 20% and 60%). The simulation analysis was followed by an extensive field test of a retrofittable advanced rooftop unit (RTU) controller.

Katipamula, Srinivas↗

ComStock Measure Documentation: Fan Static Pressure Reset for Multizone Variable Air Volume Systems

This report assesses the potential for nationwide adoption of a duct static pressure reset in MZ VAV systems in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario—Fan Static Pressure Reset for Multizone Variable Air Volume (VAV) Systems—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Defect‐Tailoring Mediated Electron–Hole Separation in Single‐Unit‐Cell Bi 3 O 4 Br Nanosheets for Boosting Photocatalytic Hydrogen Evolution and Nitrogen Fixation

Abstract Solar photocatalysis is a potential solution to satisfying energy demand and its resulting environmental impact. However, the low electron–hole separation efficiency in semiconductors has slowed the development of this technology. The effect of defects on electron–hole separation is not always clear. A model atomically thin structure of single‐unit‐cell Bi 3 O 4 Br nanosheets with surface defects is proposed to boost photocatalytic efficiency by simultaneously promoting bulk‐ and surface‐charge separation. Defect‐rich single‐unit‐cell Bi 3 O 4 Br displays 4.9 and 30.9 times enhanced photocatalytic hydrogen evolution and nitrogen fixation activity, respectively, than bulk Bi 3 O 4 Br. After the preparation of single‐unit‐cell structure, the bismuth defects are controlled to tune the oxygen defects. Benefiting from the unique single‐unit‐cell architecture and defects, the local atomic arrangement and electronic structure are tuned so as to greatly increase the charge separation efficiency and subsequently boost photocatalytic activity. This strategy provides an accessible pathway for next‐generation photocatalysts.

Di, Jun↗

A diffusive information preservation method for small Knudsen number flows

The direct simulation Monte Carlo (DSMC) method is a powerful particle-based method for modeling gas flows. It works well for relatively large Knudsen (Kn) numbers, typically larger than 0.01, but quickly becomes computationally intensive as Kn decreases due to its time step and cell size limitations. An alternative approach was proposed to relax or remove these limitations, based on replacing pairwise collisions with a stochastic model corresponding to the Fokker–Planck equation [J. Comput. Phys., 229, 1077 (2010); J. Fluid Mech., 680, 574 (2011)]. Similar to the DSMC method, the downside of that approach suffers from computationally statistical noise. To solve the problem, a diffusion-based information preservation (D-IP) method has been developed. The main idea is to track the motion of a simulated molecule from the diffusive standpoint, and obtain the flow velocity and temperature through sampling and averaging the IP quantities. To validate the idea and the corresponding model, several benchmark problems with Kn ∼ 10{sup −3}–10{sup −4} have been investigated. It is shown that the IP calculations are not only accurate, but also efficient because they make possible using a time step and cell size over an order of magnitude larger than the mean collision time and mean free path, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interfacial Engineering for High Efficiency Nanorod Array Structured Perovskite Solar Cells

TiO 2 nanorod (NR) array for perovskite solar cells (PSCs) has attached great importance due to superb power conversion efficiency (PCE) compared to traditional mesoporous TiO 2 film. A TiO 2 compact layer for the growth of TiO 2 NR array via spin-coating cannot meet the requirements for efficient NR based PSCs. Herein we have developed and demonstrated inserting an bifunctional extra-thin TiO 2 interlayer (5 nm) by atomic layer deposition (ALD) at the interface of FTO/TiO 2 compact layer to achieve an alleviated electron exchange and a reduced energetic barrier. Thus, an accelerated extraction of electrons from TiO 2 NR arrays via the compact layer to FTO substrate is ready for improving the PSC efficiency. The thickness of the spin-coated TiO 2 compact layer on the ALD-deposited TiO 2 layer is spontaneously optimized. Finally, an outstanding efficiency of 20.28% has been achieved from a champion PSC with negligible hysteresis and high reliability. To the best of our knowledge, this is the first time to demonstrate the superiority of TiO 2 -NR based PSCs withstanding in dry heat and thermal cycling tests. The results are of great importance for the preparation of efficient and durable PSCs for our real-world applications.

25 ENERGY STORAGE↗

Facile and Scalable Synthesis of Metal- and Nitrogen-Doped Carbon Nanotubes for Efficient Electrochemical CO 2 Reduction

Metal- and nitrogen-doped carbon (M–N–C) is a promising material to catalyze electrochemical CO 2 reduction reaction (CO 2 RR). However, most M–N–C catalysts in the literature require complicated synthesis procedures and produce small quantities per batch, limiting the commercialization potential. In this work, we developed a simple and scalable synthesis method to convert metal-impurity-containing commercial carbon nanotubes (CNTs) and nitrogen-containing organic precursors into M–N–C via one-step moderate-temperature (650 °C) pyrolysis without any other treatment nor the need to add metal precursors. Batches of catalysts in varied mass up to 10 g (150 mL in volume) per batch were synthesized, and repeatable catalytic performances were demonstrated. To the best of our knowledge, the 10 g batch is one of the largest batches of CO2RR catalysts synthesized in the literature while requiring minimal synthesis steps. The catalyst possessed single-atomic iron–nitrogen (Fe–N) sites, enabling a high performance of >95% CO product selectivity at a high current density of 400 mA/cm 2 and high stability for 45 h at 100 mA/cm 2 in a flow cell testing. The catalyst outperformed a benchmark noble-metal nanoparticle catalyst and achieved longer stability than many other reported M–N–C catalysts in the literature. The scalable and cost-effective synthesis developed in this work paves a pathway toward practical CO 2 RR applications. The direct utilization of metal impurities from raw CNTs for efficient catalyst synthesis with minimal treatment is a green and sustainable engineering approach.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tailoring Interfaces for Enhanced Methanol Production from Photoelectrochemical CO 2 Reduction

Efficient and stable photoelectrochemical reduction of CO 2 into highly reduced liquid fuels remains a formidable challenge, which requires an innovative semiconductor/catalyst interface to tackle. In this study, we introduce a strategy involving the fabrication of a silicon micropillar array structure coated with a superhydrophobic fluorinated carbon layer for the photoelectrochemical conversion of CO 2 into methanol. The pillars increase the electrode surface area, improve catalyst loading and adhesion without compromising light absorption, and help confine gaseous intermediates near the catalyst surface. The superhydrophobic coating passivates parasitic side reactions and further enhances local accumulation of reaction intermediates. Upon one-electron reduction of the molecular catalyst, the semiconductor–catalyst interface changes from adaptive to buried junctions, providing a sufficient thermodynamic driving force for CO 2 reduction. These structures together create a unique microenvironment for effective reduction of CO 2 to methanol, leading to a remarkable Faradaic efficiency reaching 20% together with a partial current density of 3.4 mA cm –2 , surpassing the previous record based on planar silicon photoelectrodes by a notable factor of 17. Furthermore, this work demonstrates a new pathway for enhancing photoelectrocatalytic CO 2 reduction through meticulous interface and microenvironment tailoring and sets a benchmark for both Faradaic efficiency and current density in solar liquid fuel production.

14 SOLAR ENERGY↗

Bidirectional interconversion of microwave and light with thin-film lithium niobate

Abstract Superconducting cavity electro-optics presents a promising route to coherently convert microwave and optical photons and distribute quantum entanglement between superconducting circuits over long-distance. Strong Pockels nonlinearity and high-performance optical cavity are the prerequisites for high conversion efficiency. Thin-film lithium niobate (TFLN) offers these desired characteristics. Despite significant recent progresses, only unidirectional conversion with efficiencies on the order of 10 −5 has been realized. In this article, we demonstrate the bidirectional electro-optic conversion in TFLN-superconductor hybrid system, with conversion efficiency improved by more than three orders of magnitude. Our air-clad device architecture boosts the sustainable intracavity pump power at cryogenic temperatures by suppressing the prominent photorefractive effect that limits cryogenic performance of TFLN, and reaches an efficiency of 1.02% (internal efficiency of 15.2%). This work firmly establishes the TFLN-superconductor hybrid EO system as a highly competitive transduction platform for future quantum network applications.

42 ENGINEERING↗

All-temperature batteries enabled by fluorinated electrolytes with non-polar solvents

We report carbonate electrolytes are commonly used in commercial non-aqueous Li-ion batteries. However, the high affinity between the solvents and the ions and high flammability of the carbonate electrolytes limits the battery operation temperature window from -20 to +50 °C and voltage window from 0.0 to 4.3 V. Here we tamed the affinity between solvents and Li ions of the nonflammable electrolytes by dissolving the fluorinated electrolytes into highly fluorinated non-polar solvents. The tamed non-flammable electrolytes have a wide voltage window of 0.0 to 5.6 V, wide liquid range from -125 to +70 °C, high Li-ion transference number of 0.7, and low Li-ion desolvation energy. In a wide temperature from -95 to +70 °C, the electrolytes enable both commercial graphite anodes and LiNi0.8Mn0.1Co0.1O2 cathodes to achieve a high Coulombic efficiencies of >99.9%, and the most aggressive Li2 anodes and 5.4 V LiCoMnO4 to achieve a Coulombic efficiencies of >99.4% and 99%, respectively. Even at -85 °C, the LiNi 0.8 Co 0.15 Al 0.05 O 2 ||Li battery can still deliver ~50% of room-temperature capacity

25 ENERGY STORAGE↗

Design and experiment of a cross-shaped mode converter for high-power microwave applications

A compact mode converter, which is capable of converting a TM{sub 01} mode into a circularly polarized TE{sub 11} mode, was developed and experimentally studied with high-power microwaves. The converter, consisting of two turnstile junctions, is very short along the wave propagation direction, and therefore is suitable for designing compact and axially aligned high-power microwave radiation systems. In this paper, the principle of a converter working at 1.75 GHz is demonstrated, as well as the experimental results. The experimental and simulation results are in good agreement. At the center frequency, the conversion efficiency is more than 95%, the measured axial ratio is about 0.4 dB, and the power-handing capacity is excess of 1.9 GW.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rapid Temperature Swing Adsorption using Polymeric/Supported Amine Hollow Fibers

This project is a bench-scale, post-combustion capture project carried out at Georgia Tech (GT) with support and collaboration with GE, Algenol Biofuels, Southern Company and subcontract to Trimeric Corporation. The focus of the project is to develop a process based on composite amine-functionalized oxide / polymer hollow fibers for use as contactors in a rapid temperature swing adsorption post-combustion carbon dioxide capture process. The hollow fiber morphology allows coupling of efficient heat transfer with effective gas contacting, potentially giving lower parasitic loads on the power plant compared to traditional contacting strategies using solid sorbents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation-aided characterization of a versatile water-based condensation particle counter for atmospheric airborne research

Capturing the vertical profiles and horizontal variations of atmospheric aerosols often requires accurate airborne measurements. With the advantage of avoiding health and safety concerns related to the use of butanol or other chemicals, water-based condensation particle counters have emerged to provide measurements under various environments. However, airborne deployments are relatively rare due to the lack of instrument characterization under reduced pressure at flight altitudes. This study investigates the performance of a commercial “versatile” water-based condensation particle counter (vWCPC, model 3789, TSI, Shoreview, MN, USA) under various ambient pressure conditions (500–920 hPa) with a wide range of particle total number concentrations (1500–70 000 cm -3 ). The effect of conditioner temperature on vWCPC 3789 performance at low pressure is examined through numerical simulation and laboratory experiments. We show that the default instrument temperature setting of 30 °C for the conditioner is not suitable for airborne measurement and that the optimal conditioner temperature for low-pressure operation is 27°. Under the optimal conditioner temperature (27°), the 7 nm cut-off size is also maintained. Additionally, we show that insufficient droplet growth becomes more significant under the low-pressure operation. The counting efficiency of the vWCPC 3789 can vary up to 20 % for particles of different chemical compositions (e.g., ammonium sulfate and sucrose particles). However, such variation is independent of pressure.

54 ENVIRONMENTAL SCIENCES↗

Highly loaded multi-stage fan drive turbine: Performance of final three configurations

Results for a three-stage highly loaded fan drive turbine follow-on test program are presented. The effects of combinations of tandem and leaned bladerows on three-stage turbine performance were tested. The three-stage turbine with a tandem stator in stage two exhibited a total-to-total efficiency of approximately 0.887 as compared to 0.886 for the plain blade turbine base case.

Cherry, D. G.↗

Efficient AlGaAs shallow-homojunction solar cells

Shallow-homojunction n+/p/p+ solar cells with one-sun, AM1 conversion efficiencies as high as 12.9 percent have been fabricated in Al0.2Ga0.8As epitaxial layers grown by organometallic chemical vapor deposition on single-crystal GaAs substrates. For these cells, which have n+ layers thinned by anodic oxidation to about 500 A, the quantum efficiencies in the short-wavelength portion of the spectrum are as high as the best reported for AlGaAs cells with high band-gap window layers.

Gale, R. P.↗