Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error localization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Uncertainty Analyses for Localized Tallies in Monte Carlo Eigenvalue Calculations

It is well known that statistical estimates obtained from Monte Carlo criticality simulations can be adversely affected by cycle-to-cycle correlations in the fission source. In addition, there are several other more fundamental issues that may lead to errors in Monte Carlo results. These factors can have a significant impact on the calculated eigenvalue, localized tally means and their associated standard deviations. In fact, modern Monte Carlo computational tools may generate standard deviation estimates that are a factor of five or more lower than the true standard deviation for a particular tally due to the inter-cycle correlations in the fission source. The magnitude of this under-prediction can climb as high as one hundred when combined with an ill-converged fission source or poor sampling techniques. Since Monte Carlo methods are widely used in reactor analysis (as a benchmarking tool) and criticality safety applications, an in-depth understanding of the effects of these issues must be developed in order to support the practical use of Monte Carlo software packages. A rigorous statistical analysis of localized tally results in eigenvalue calculations is presented using the SCALE/KENO-VI and MCNP Monte Carlo codes. The purpose of this analysis is to investigate the under-prediction in the uncertainty and its sensitivity to problem characteristics and calculational parameters, and to provide a comparative study between the two codes with respect to this under-prediction. It is shown herein that adequate source convergence along with proper specification of Monte Carlo parameters can reduce the magnitude of under-prediction in the uncertainty to reasonable levels; below a factor of 2 when inter-cycle correlations in the fission source are not a significant factor. In addition, through the use of a modified sampling procedure, the effects of inter-cycle correlations on both the mean value and standard deviation estimates can be isolated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-202: Comparison of 4D-Measurement-Guided Dose Reconstructions (MGDR) with COMPASS and OCTAVIUS 4D System

Purpose: To cross-validate the MGDR of COMPASS (IBA dosimetry, GmbH, Germany) and OCTAVIUS 4D system (PTW, Freiburg, Germany). Methods: Volumetric-modulated arc plans (5 head-and-neck and 3 prostate) collapsed to 40° gantry on the OCTAVIUS 4D phantom in QA mode on Monaco v5.0 (Elekta, CMS, Maryland Heights, MO) were delivered on a Elekta Agility linac. This study was divided into two parts: (1) error-free measurements by gantry-mounted EvolutionXX 2D array were reconstructed in COMPASS (IBA dosimetry, GmbH, Germany), and by OCTAVIUS 1500 array in Versoft v6.1 (PTW, Freiburg, Germany) to obtain the 3D doses (COM4D and OCTA4D). COM4D and OCTA4D were compared to the raw measurement (OCTA3D) at the same detector plane for which OCTAVIUS 1500 was perpendicular to 0° gantry axis while the plans were delivered at gantry 40°; (2) beam steering errors of energy (Hump=-2%) and symmetry (2T=+2%) were introduced during the delivery of 5 plans to compare the MGDR doses COM4D-Hump (COM4D-2T), OCTA4D-Hump (OCTA4D-2T), with raw doses OCTA3D-Hump (OCTA3D-2T) and with OCTA3D to assess the error reconstruction and detection ability of MGDR tools. All comparisons used Υ-criteria of 2%(local dose)/2mm and 3%/3mm. Results: Averaged Υ passing rates were 85% and 96% for COM4D,and 94% and 99% for OCTA4D at 2%/2mm and 3%/3mm criteria respectively. For error reconstruction, COM4D-Hump (COM4D-2T) showed 81% (93%) at 2%/2mm and 94% (98%) at 3%/3mm, while OCTA4D-Hump (OCTA4D-2T) showed 96% (96%) at 2%/2mm and 99% (99%) at 3%/3mm. For error detection, OCTA3D doses were compared to COM4D-Hump (COM4D-2T) showing Υ passing rates of 93% (93%) at 2%/2mm and 98% (98%), and to OCTA4D-Hump (OCTA4D -2T) showing 94% (99%) at 2%/2mm and 81% (96%) at 3%/3mm, respectively. Conclusion: OCTAVIUS MGDR showed better agreement to raw measurements in both error- and error-free comparisons. COMPASS MGDR deviated from the raw measurements possibly owing to beam modeling uncertainty.

60 APPLIED LIFE SCIENCES↗

Quadratic pseudospectrum for identifying localized states

Here we examine the utility of the quadratic pseudospectrum for understanding and detecting states that are somewhat localized in position and energy, in particular, in the context of condensed matter physics. Specifically, the quadratic pseudospectrum represents a method for approaching systems with incompatible observables {A j |1 ≤ j ≤ d} as it minimizes collectively the errors $\parallel$A j v - λ j v$\parallel$ while defining a joint approximate spectrum of incompatible observables. Moreover, we derive an important estimate relating the Clifford and quadratic pseudospectra. Finally, we prove that the quadratic pseudospectrum is local and derive the bounds on the errors that are incurred by truncating the system in the vicinity of where the pseudospectrum is being calculated.

97 MATHEMATICS AND COMPUTING↗

Fuel Cycle Research & Development Technical Monthly – May 2012

Management and Integration LANL - Initial coordination meetings with NE and NA-20 were held the first week of May. Additional meetings, to include NA-82 and the new Proliferation and Terrorism Risk Assessment task are scheduled for June. Work package planning as part of the NTD transition is ongoing. Microcalorimetry LANL - Some parts to attempt repair of a malfunctioning water chiller that has been holding up work on the current detector array have arrived. We will attempt to begin running the compressor/cryostat next week to resume work on commissioning the detector array. We have also been working on a backup plan to temporarily move our system to a different lab space. Completed data analysis and prepared a paper summarizing Pu measurements for peer-review journal. Two members of our team presented work at the SORMA West 2012 conference. Completed data analysis and prepared a milestone report summarizing the development of Monte Carlo tools to study systematic errors. Electrochemical Sensor INL - The second sensor test was stopped short due to the work stand-down. Some activities related to this work have resumed, but not all. The sensor used during the second test was removed from the furnace and it showed cracks and later crumbled when being rinsed for sample preparation. The sensor material will be submitted to SEM analysis once work is resumed in the facilities where analysis is performed. A third sensor test has started. Tests with different arrangements will continue and will be oriented based on post-test analysis of the first three sensor tests. Materials with different annealing temperatures will also be prepared for analysis. Lead slowing down spectrometer LANL - Continued work on perturbation method for LSDS analysis. We are running simulations to delineate issues and are checking additional data libraries to see whether there are differences in simulation results. Electrochemical sensor INL - The second sensor test was stopped short due to the work stand-down. Some activities related to this work have resumed, but not all. The sensor used during the second test was removed from the furnace and it showed cracks and later crumbled when being rinsed for sample preparation. The sensor material will be submitted to SEM analysis once work is resumed in the facilities where analysis is performed. A third sensor test has started. Tests with different arrangements will continue and will be oriented based on post-test analysis of the first three sensor tests. Materials with different annealing temperatures will also be prepared for analysis. Fast Neutron Multiplicity analysis INL - The University of Michigan team continues its work on the post-experiment analysis of the validation data from JRC ISPRA, as well as scoping studies using the simulation tool MCNPX-PoliMi. At INL, our new staff member working on this project is now working to model performance capabilities for the fast-neutrons scintillator design concepts. At INL our primary analysis approach is focused on the Feynman mean-to-variance approach. At the University of Michigan, the primary analysis approach is multiplicity coincidence analysis. Fast Neutron Imaging to Quantify Nuclear Materials ORNL - Completed additional measurements of the two 'trainer' configurations as well as calibration measurements with sources on an x-y stage. The imager was shipped to Pantex for an NA-22 obligation at the end of May. Lead Slowing Down Spectrometer LANL - Continued to look into He4 detector. A Swiss company was located that makes He4 detectors and associated electronics. Had a teleconference with them to assess the possible help we can get from them. We are also looking in to constructing one locally. Ongoing perturbation calculations are providing information on the fundamental systematic error limits of LSDS. In order to achieve separating the contribution of Pu and 235U to the signal, there will need to be tight controls on systematic errors. Multi-isotope Process Monitor PNNL - Attended a training call in advanced multivariate classification and analysis methods. These methods were applied to the multivariate analysis of fuel characteristics based on simulated gamma. Work continued on a computational framework to quantify the impact of gamma-ray counting statistical precision on principal component regression (PCR) analysis of a multi-component (i.e. multi-isotope) gammaray spectrum. Tests of the simulation framework are anticipated to begin in early June. Development of a proposal to instrument H-Canyon is being prepared in conjunction with SRNL and the NNSA's NGSI program is ongoing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermographic process monitoring in powderbed based additive manufacturing

Selective Laser Melting is utilized to build metallic parts directly from CAD-Data by solidification of thin powder layers through application of a fast scanning laser beam. In this study layerwise monitoring of the temperature distribution is used to gather information about the process stability and the resulting part quality. The heat distribution varies with different kinds of parameters including scan vector length, laser power, layer thickness and inter-part distance in the job layout which in turn influence the resulting part quality. By integration of an off-axis mounted uncooled thermal detector the solidification as well as the layer deposition are monitored and evaluated. Errors in the generation of new powder layers usually result in a locally varying layer thickness that may cause poor part quality. For effect quantification, the locally applied layer thickness is determined by evaluating the heat-up of the newly deposited powder. During the solidification process space and time-resolved data is used to characterize the zone of elevated temperatures and to derive locally varying heat dissipation properties. Potential quality indicators are evaluated and correlated to the resulting part quality: Thermal diffusivity is derived from a simplified heat dissipation model and evaluated for every pixel and cool-down phase of a layer. This allows the quantification of expected material homogeneity properties. Maximum temperature and time above certain temperatures are measured in order to detect hot spots or delamination issues that may cause a process breakdown. Furthermore, a method for quantification of sputter activity is presented. Since high sputter activity indicates unstable melt dynamics this can be used to identify parameter drifts, improper atmospheric conditions or material binding errors. The resulting surface structure after solidification complicates temperature determination on the one hand but enables the detection of potential surface defects on the other hand. These issues and proper key figures for thermographic monitoring of the Selective Laser Melting process are discussed in the paper. Even though microbolometric temperature measurement is limited to repetition rates in the Hz-regime and sub megapixel resolution, current results show the feasibility of process surveillance by thermography for a limited section of the building platform in a commercial system.

42 ENGINEERING↗

Real-time catheter tracking for high-dose-rate prostate brachytherapy using an electromagnetic 3D-guidance device: A preliminary performance study

Purpose: In order to increase the accuracy and speed of catheter reconstruction in a high-dose-rate (HDR) prostate implant procedure, an automatic tracking system has been developed using an electromagnetic (EM) device (trakSTAR, Ascension Technology, VT). The performance of the system, including the accuracy and noise level with various tracking parameters and conditions, were investigated. Methods: A direct current (dc) EM transmitter (midrange model) and a sensor with diameter of 1.3 mm (Model 130) were used in the trakSTAR system for tracking catheter position during HDR prostate brachytherapy. Localization accuracy was assessed under both static and dynamic analyses conditions. For the static analysis, a calibration phantom was used to investigate error dependency on operating room (OR) table height (bottom vs midposition vs top), sensor position (distal tip of catheter vs connector end of catheter), direction [left-right (LR) vs anterior-posterior (AP) vs superior-inferior (SI)], sampling frequency (40 vs 80 vs 120 Hz), and interference from OR equipment (present vs absent). The mean and standard deviation of the localization offset in each direction and the corresponding error vectors were calculated. For dynamic analysis, the paths of five straight catheters were tracked to study the effects of directions, sampling frequency, and interference of EM field. Statistical analysis was conducted to compare the results in different configurations. Results: When interference was present in the static analysis, the error vectors were significantly higher at the top table position (3.3 {+-} 1.3 vs 1.8 {+-} 0.9 mm at bottom and 1.7 {+-} 1.0 mm at middle, p < 0.001), at catheter end position (3.1 {+-} 1.1 vs 1.4 {+-} 0.7 mm at the tip position, p < 0.001), and at 40 Hz sampling frequency (2.6 {+-} 1.1 vs 2.4 {+-} 1.5 mm at 80 Hz and 1.8 {+-} 1.1 at 160 Hz, p < 0.001). So did the mean offset errors in the LR direction (-1.7 {+-} 1.4 vs 0.4 {+-} 0.5 mm in AP and 0.8 {+-} 0.8 mm in SI directions, p < 0.001). The error vectors were significantly higher with surrounding interference (2.2 {+-} 1.3 mm) vs without interference (1.0 {+-} 0.7 mm, p < 0.001). An accuracy of 1.6 {+-} 0.2 mm can be reached when using optimum configuration (160 Hz at middle table position). When interference was present in the dynamic tracking, the mean tracking errors in LR direction (1.4 {+-} 0.5 mm) was significantly higher than that in AP direction (0.3 {+-} 0.2 mm, p < 0.001). So did the mean vector errors at 40 Hz (2.1 {+-} 0.2 mm vs 1.3 {+-} 0.2 mm at 80 Hz and 0.9 {+-} 0.2 mm at 160 Hz, p < 0.05). However, when interference was absent, they were comparable in the both directions and at all sampling frequencies. An accuracy of 0.9 {+-} 0.2 mm was obtained for the dynamic tracking when using optimum configuration. Conclusions: The performance of an EM tracking system depends highly on the system configuration and surrounding environment. The accuracy of EM tracking for catheter reconstruction in a prostate HDR brachytherapy procedure can be improved by reducing interference from surrounding equipment, decreasing distance from transmitter to tracking area, and choosing appropriated sampling frequency. A calibration scheme is needed to further reduce the tracking error when the interference is high.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Breast-Conserving Therapy: Radiotherapy Margins for Breast Tumor Bed Boost

Purpose: To quantify the interfraction position variability of the excision cavity (EC) and to compare the rib and breast surface as surrogates for the cavity. Additionally, we sought to determine the required margin for on-line, off-line and no correction protocols in external beam radiotherapy. Methods and Materials: A total of 20 patients were studied who had been treated in the supine position for 28 daily fractions. Cone-beam computed tomography scans were regularly acquired according to a shrinking action level setup correction protocol based on bony anatomy registration of the ribs and sternum. The position of the excision area was retrospectively analyzed by gray value cone-beam computed tomography-to-computed tomography registration. Subsequently, three setup correction strategies (on-line, off-line, and no corrections) were applied, according to the rib and breast surface registrations, to estimate the residual setup errors (systematic [{sigma}] and random [{sigma}]) of the excision area. The required margins were calculated using a margin recipe. Results: The image quality of the cone-beam computed tomography scans was sufficient for localization of the EC. The margins required for the investigated setup correction protocols and the setup errors for the left-right, craniocaudal and anteroposterior directions were 8.3 mm ({sigma} = 3.0, {sigma} = 2.6), 10.6 mm ({sigma} = 3.8, {sigma} = 3.2), and 7.7 mm ({sigma} = 2.7, {sigma} = 2.9) for the no correction strategy; 5.6 mm ({sigma} = 2.0, {sigma} = 1.8), 6.5 mm ({sigma} = 2.3, {sigma} = 2.3), and 4.5 mm ({sigma} = 1.5, {sigma} = 1.9) for the on-line rib strategy; and 5.1 mm ({sigma} = 1.8, {sigma} = 1.7), 4.8 mm ({sigma} = 1.7, {sigma} = 1.6), and 3.3 mm ({sigma} = 1.1, {sigma} = 1.6) for the on-line surface strategy, respectively. Conclusion: Considerable geometric uncertainties in the position of the EC relative to the bony anatomy and breast surface have been observed. By using registration of the breast surface, instead of the rib, the uncertainties in the position of the EC area were reduced.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bit error rate measurement above and below bit rate tracking threshold

Bit error rate is measured by sending a pseudo-random noise (PRN) code test signal simulating digital data through digital equipment to be tested. An incoming signal representing the response of the equipment being tested, together with any added noise, is received and tracked by being compared with a locally generated PRN code. Once the locally generated PRN code matches the incoming signal a tracking lock is obtained. The incoming signal is then integrated and compared bit-by-bit against the locally generated PRN code and differences between bits being compared are counted as bit errors.

Kobayaski, H. S.↗

WE-H-BRC-09: Simulated Errors in Mock Radiotherapy Plans to Quantify the Effectiveness of the Physics Plan Review

Purpose: A standard tool for ensuring the quality of radiation therapy treatments is the initial physics plan review. However, little is known about its performance in practice. The goal of this study is to measure the effectiveness of physics plan review by introducing simulated errors into “mock” treatment plans and measuring the performance of plan review by physicists. Methods: We generated six mock treatment plans containing multiple errors. These errors were based on incident learning system data both within the department and internationally (SAFRON). These errors were scored for severity and frequency. Those with the highest scores were included in the simulations (13 errors total). Observer bias was minimized using a multiple co-correlated distractor approach. Eight physicists reviewed these plans for errors, with each physicist reviewing, on average, 3/6 plans. The confidence interval for the proportion of errors detected was computed using the Wilson score interval. Results: Simulated errors were detected in 65% of reviews [51–75%] (95% confidence interval [CI] in brackets). The following error scenarios had the highest detection rates: incorrect isocenter in DRRs/CBCT (91% [73–98%]) and a planned dose different from the prescribed dose (100% [61–100%]). Errors with low detection rates involved incorrect field parameters in record and verify system (38%, [18–61%]) and incorrect isocenter localization in planning system (29% [8–64%]). Though pre-treatment QA failure was reliably identified (100%), less than 20% of participants reported the error that caused the failure. Conclusion: This is one of the first quantitative studies of error detection. Although physics plan review is a key safety measure and can identify some errors with high fidelity, others errors are more challenging to detect. This data will guide future work on standardization and automation. Creating new checks or improving existing ones (i.e., via automation) will help in detecting those errors with low detection rates.

60 APPLIED LIFE SCIENCES↗

An algorithm for using a laser anemometer to determine mean streamline patterns in a turbulent flow

The technique of tracing out a mean flow streamline with a three dimensional laser Doppler anemometer (LDA) is discussed with respect to cumulative, systematic errors that are inherent when the motion of the LDA test point is in the direction of the local measured velocity. Using simple potential flows that have variable curvature and inflection points to simulate an LDA experiment, a streamline tracing algorithm is developed that minimizes these errors. Also, the test point path remains close to the correct streamline even when simulated statistical measurement variations are included.

Orloff, K. L.↗

Extensibility in local sensor based planning for hyper-redundant manipulators (robot snakes)

Partial Shape Modification (PSM) is a local sensor feedback method used for hyper-redundant robot manipulators, in which the redundancy is very large or infinite such as that of a robot snake. This aspect of redundancy enables local obstacle avoidance and end-effector placement in real time. Due to the large number of joints or actuators in a hyper-redundant manipulator, small displacement errors of such easily accumulate to large errors in the position of the tip relative to the base. The accuracy could be improved by a local sensor based planning method in which sensors are distributed along the length of the hyper-redundant robot. This paper extends the local sensor based planning strategy beyond the limitations of the fixed length of such a manipulator when its joint limits are met. This is achieved with an algorithm where the length of the deforming part of the robot is variable. Thus , the robot's local avoidance of obstacles is improved through the enhancement of its extensibility.

Choset, Howie↗

Quantifying predictability variations in a low-order ocean-atmosphere model - A dynamical systems approach

The predictability of the weather and climatic states of a low-order moist general circulation model is quantified using a dynamic systems approach, and the effect of incorporating a simple oceanic circulation on predictability is evaluated. The predictability and the structure of the model attractors are compared using Liapunov exponents, local divergence rates, and the correlation and Liapunov dimensions. It was found that the activation of oceanic circulation increases the average error doubling time of the atmosphere and the coupled ocean-atmosphere system by 10 percent and decreases the variance of the largest local divergence rate by 20 percent. When an oceanic circulation develops, the average predictability of annually averaged states is improved by 25 percent and the variance of the largest local divergence rate decreases by 25 percent.

Nese, Jon M.↗

Lightning Reporting at 45th Weather Squadron: Recent Improvements

The 45th Weather Squadron (45 WS) provides daily lightning reports to space launch customers at CCAFS/KSC. These reports are provided to assess the need to inspect the electronics of satellite payloads, space launch vehicles, and ground support equipment for induced current damage from nearby lightning strokes. The 45 WS has made several improvements to the lightning reports during 2008-2009. The 4DLSS, implemented in April 2008, provides all lightning strokes as opposed to just one stroke per flash as done by the previous system. The 45 WS discovered that the peak current was being truncated to the nearest kilo amp in the database used to generate the daily lightning reports, which led to an up to 4% underestimate in the peak current for average lightning. This error was corrected and led to elimination of this underestimate. The 45 WS and their mission partners developed lightning location error ellipses for 99% and 95% location accuracies tailored to each individual stroke and began providing them in the spring of 2009. The new procedure provides the distance from the point of interest to the best location of the stroke (the center of the error ellipse) and the distance to the closest edge of the ellipse. This information is now included in the lightning reports, along with the peak current of the stroke. The initial method of calculating the error ellipses could only be used during normal duty hours, i.e. not during nights, weekends, or holidays. This method was improved later to provide lightning reports in near real-time, 24/7. The calculation of the distance to the closest point on the ellipse was also significantly improved later. Other improvements were also implemented. A new method to calculate the probability of any nearby lightning stroke. being within any radius of any point of interest was developed and is being implemented. This may supersede the use of location error ellipses. The 45 WS is pursuing adding data from nine NLDN sensors into 4DLSS in real-time. This will overcome the problem of 4DLSS missing some of the strong local strokes. This will also improve the location accuracy, reduce the size and eccentricity of the location error ellipses, and reduce the probability of nearby strokes being inside the areas of interest when few of the 4DLSS sensors are used in the stroke solution. This will not reduce 4DLSS performance when most of the 4DLSS sensors are used in the stroke solution. Finally, several possible future improvements were discussed, especially for improving the peak current estimate and the error estimate for peak current, and upgrading the 4DLSS. Some possible approaches for both of these goals were discussed.

Finn, Frank C.↗

Formaldehyde Distribution over North America: Implications for Satellite Retrievals of Formaldehyde Columns and Isoprene Emission

Formaldehyde (HCHO) columns measured from space provide constraints on emissions of volatile organic compounds (VOCs). Quantitative interpretation requires characterization of errors in HCHO column retrievals and relating these columns to VOC emissions. Retrieval error is mainly in the air mass factor (AMF) which relates fitted backscattered radiances to vertical columns and requires external information on HCHO, aerosols, and clouds. Here we use aircraft data collected over North America and the Atlantic to determine the local relationships between HCHO columns and VOC emissions, calculate AMFs for HCHO retrievals, assess the errors in deriving AMFs with a chemical transport model (GEOS-Chem), and draw conclusions regarding space-based mapping of VOC emissions. We show that isoprene drives observed HCHO column variability over North America; HCHO column data from space can thus be used effectively as a proxy for isoprene emission. From observed HCHO and isoprene profiles we find an HCHO molar yield from isoprene oxidation of 1.6 +/- 0.5, consistent with current chemical mechanisms. Clouds are the primary error source in the AMF calculation; errors in the HCHO vertical profile and aerosols have comparatively little effect. The mean bias and 1Q uncertainty in the GEOS-Chem AMF calculation increase from <1% and 15% for clear skies to 17% and 24% for half-cloudy scenes. With fitting errors, this gives an overall 1 Q error in HCHO satellite measurements of 25-31%. Retrieval errors, combined with uncertainties in the HCHO yield from isoprene oxidation, result in a 40% (1sigma) error in inferring isoprene emissions from HCHO satellite measurements.

Millet, Dylan B.↗

Efficient Bayesian inference with latent Hamiltonian neural networks in No-U-Turn Sampling

When sampling for Bayesian inference, one popular approach in the computational field is to use Hamiltonian Monte Carlo (HMC) and specifically the No-U-Turn Sampler (NUTS), which automatically decides the end time of the Hamiltonian trajectory. However, HMC and NUTS can require numerous numerical gradients of the target density and can prove slow in practice when relying on computationally expensive forward models. We propose Latent Hamiltonian neural networks (L-HNNs) with HMC and NUTS for solving Bayesian inference problems. Once trained, L-HNNs do not require numerical gradients of the target density during sampling, and hence numerous evaluations of the forward computational model. Moreover, L-HNNs satisfy important properties such as perfect time reversibility and Hamiltonian conservation, making them well-suited for use within HMC and NUTS because stationarity can be shown. We also propose the integration of L-HNNs in an online error monitoring scheme, in which numerical gradients of the target density are used for a few samples whenever the L-HNNs prediction errors are large. This online error monitor scheme prevents sample degeneracy in regions of low probability density and ensures robust uncertainty quantification. We demonstrate L-HNNs in NUTS with online error monitoring on several analytical examples involving complex, heavy-tailed, and high-local-curvature probability densities. We then demonstrate the applicability of L-HNNs in NUTS to two computational case studies, namely the Allen-Cahn stochastic partial differential equation and an elliptic partial differential equation with 25 and 50 inference parameters, respectively. Overall, the L-HNNs in NUTS with online error monitoring satisfactorily inferred these probability densities. In conclusion, compared to traditional NUTS, L-HNNs in NUTS with online error monitoring required 1–2 orders of magnitude fewer numerical gradients of the target density and improved the effective sample size (ESS) per gradient (which is a measure of both the sampling quality and the computational expense) by an order of magnitude.

97 MATHEMATICS AND COMPUTING↗

Generation of localized reactor point kinetics parameters using coupled neutronic and thermal fluid models for pebble-bed reactor transient analysis

The systems analysis of anticipated operating occurrences and design basis accidents for pebble-bed reactor systems requires knowledge of neutron point kinetics equations (PKE) parameters. Typically, the generation of PKE parameters is performed in a global manner using standalone neutronics calculations, without the inclusion of thermal fluid distributions. We utilize Griffin and Pronghorn for generating global and local PKE parameters which includes the use of thermal fluid distributions to account for localized effects. This work establishes a methodology for calculating PKE parameters for a pebble bed reactor with a coupled neutronics/thermal fluids analysis. PKE parameters generated on a global and local basis are compared against a diffusion solve for a typical load-following transient. Locally-generated neutron kinetic parameters are able to reduce the maximum error in the transient power level from 5% to below 1.5%; along with this, bulk temperature errors were reduced from 12 K to 4 K.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An Anisotropic Scale-Invariant Unstructured Mesh Generator Auitable for Volumetric Imaging Data

Mesh generation algorithms must consider the computational physics schemes to be adopted insomuch as tessellation should attempt to minimize discretization error metrics a priori, while placing elements judiciously yet economically. Basing local element size and shape on local geometric feature size is a promising approach, as the underlying physics may either be scale-invariant or may vary with scale in a predictable way. We present a boundary-fitted scale-invariant unstructured tetrahedral mesh generation algorithm that enables registration of element size to local geometric scale, given a triangulated mesh surface. The resulting tetrahedra are well-shaped and nearly orthogonal to the boundary. Unlike previous feature-based approaches, our algorithm does not require a background mesh, nor does it rely on the medial-axis. In contrast, as a first step, our algorithm produces a gradientlimited feature-size field over the input surface based on efficient ray casting. We illustrate how this field can be used to produce quality grids for computational fluid dynamics based simulations of challenging, topologically complex surfaces derived from magnetic resonance images. The algorithm is implemented in the Pacific Northwest National Laboratory (PNNL) version of the Los Alamos grid toolbox LaGriT[6].

36 MATERIALS SCIENCE↗

14C and U-series disequilibria age constraints from recent eruptions at Sete Cidades volcano, Azores

Accurate dating of young (<10 ka) volcanic rocks poses numerous challenges, yet determining eruption ages is critical to understanding magmatic evolution and hazards associated with active volcanic centers. 14C dating is the preferred technique for dating young geologic materials, but a few studies have suggested that volcanic degassing can result in erroneously old 14C dates (e.g. Pasquier-Cardin et al., 1999). Finding an isotopic system with which to accurately constrain eruptive recurrence intervals at recently active volcanic centers is critical to assessing future volcanic hazards. In this study, we have obtained 14C data from modern terrestrial gastropods on Sa~o Miguel island, Azores to assess the current impact of volcanic degassing on 14C ages near active and extinct volcanic centers, and for one active volcanic center, we have compared 14C of paleosols with 226Ra-230Th maximum eruptive ages for pumices immediately overlying the respective paleosols. 14C ages of the modern terrestrial gastropod Cornu aspersum demonstrate the effects of dilution from a range of current outgassing levels at three active trachytic stratovolcanoes on Sa~o Miguel island: Sete Cidades, Fogo, Furnas, as well as the extinct Povoac¸a~o volcano. A modern gastropod sampled at Furnas, where there is evidence of extensive present-day degassing, has a 14C age of 394 ±97 y cal BP. At Fogo volcano, also a location with active degassing, the 14C age of a modern gastropod is 1324 ±60 y cal BP. Both of these ages clearly show effects of dilution of atmospheric 14C due to volcanic degassing. In contrast, there is currently no apparent outgassing occurring at Sete Cidades or Povoac¸a~o, and modern gastropod ages from these volcanoes are post-bomb. We also obtained 14C data from paleosols and 226Ra-230Th ages associated pumices from the youngest eruptive sequence of Sete Cidades volcano, the Pepom P1-P17 deposits, the ages of which are poorly constrained but thought to be <5,000 y (Queiroz, 1997). 226Ra-230Th disequilibrium in a P1 glass separate indicates a maximum eruptive age of 4440 ±195 y. 14C ages of paleosols below P1 and P3 are older than those derived from 226Ra-230Th dating, at 7293 ±141 y cal BP and 7698 ± 172 y cal BP, respectively. We interpret the 14C ages as being erroneously old due to abundant volcanic degassing at the time of eruption. Similarly, but to a lesser extent, the 226Ra-230Th maximum eruptive age of glass separated from the P8 eruption is 2659 ±55 y, whereas the age of the paleosol sampled directly beneathP8 is older (3054 ±194 y BP). In contrast, paleosols sampled at multiple field localities from below the most recent eruptive deposit (P17) are within error of each other (476 ±56 cal y BP and 585 ±68 cal y BP), while 226Ra-230Th maximum eruptive ages in glass separates from two different P17 sampling sites are 762 ±14 y and 730 y ±15 y. This is consistent with the observation that Sete Cidades volcano is experiencing limited hydrothermal activity at the present time and likely had similar low levels of degassing just prior to the last eruption. The average eruptive recurrence interval for the P1-P17 deposits, based on 226Ra-230Th maximum eruptive ages from P1 and P8 and 14C ages from P17, is ~220 years. This recurrence interval is similar to the ~200 y eruptive recurrence interval at Furnas volcano and much shorter than the ~1200 y eruptive interval at Fogo volcano. This has important implications with respect to volcanic hazards and should be considered in any future volcanic hazard planning.

U-series disequilibria, Carbon-14, Cornu aspersum,↗