Engineering PapersSearch

SEARCH · Engineering Papers

Results for “energy generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Generative AI for Wind-Wave Inflows

Extreme wind-wave conditions can create dangerous or damaging environmental conditions for sea-based structures and watercrafts. However, the model of consistent, coupled wind-wave flow conditions is computational expensive, even for simple flow scenarios. This work examines the use of diffusion-based generative artificial intelligence tools to accelerate the generation of these two-phase flows and to characterize probabilities of various states to help with the generation of extreme patterns.

17 WIND ENERGY

Equity-driven Planning of Distributed Solar PV using Optimal Transport

Typically, distribution system planning processes do not explicitly incorporate energy equity considerations, such as identifying consumers most affected by energy costs and determining how investments in the distribution system can address existing energy burden imbalances. This paper proposes a novel optimal transport (OT)-based method to improve the energy burden distribution of consumers. The approach involves the strategic siting and sizing of solar PV in order to assist customers with high energy burden and improve the overall energy burden distribution of the community. The desired energy burden distribution is defined using the equal distribution equivalent (EDE) concept. The OT-based method is then used to estimate the distributed solar PV capacity to be installed at various locations and the tariffs to be adjusted, all while improving the energy burden distribution and providing valuable insights into distributed generation (DG) planning. The results on IEEE 37 bus test system demonstrate how DG planning, considering EDE and OT, can help reduce the energy burden of low-income consumers. Additionally, the approach also reveals optimal tariff adjustments needed to ensure revenue neutrality for distribution utilities.

Optimal transport, equal distribution equivalent,

A Gigaparsec-scale Hydrodynamic Volume Reconstructed with Deep Learning

The next generation of spectroscopic surveys will map the large-scale structure of the Universe at high redshifts (2 ≤ z ≤ 5) using millions of quasar spectra, enabling major advances in constraining both the standard cosmological model and its extensions. Robust cosmological analyses of these data sets require numerical simulations that both cover gigaparsec volumes and resolve features on ∼10 kpc scales and smaller. However, running such large-volume, high-resolution hydrodynamic simulations is computationally prohibitive. We present a generative deep learning model that enhances a low-resolution, gigaparsec-scale (960 h −1 Mpc) hydrodynamic simulation using a smaller (80 h −1 Mpc) high-resolution input hydrodynamic simulation as training data. The resulting enhanced simulation reproduces the line-of-sight power spectrum to within ∼10% and the three-dimensional power spectrum at the ∼20% level at intermediate to small scales (k ≲ 2 h Mpc −1 ). Our method shows strong promise for producing realistic simulations for cosmological analyses with current surveys such as the Dark Energy Spectroscopic Instrument and upcoming next-generation experiments, but further improvements are needed to accurately recover the large-scale modes. We publicly release the enhanced hydrodynamic simulation, along with a halo catalog from a companion N-body dark matter simulation to support the calibration of data analysis pipelines for these large-scale surveys.

Convolutional neural networks

Conditional distribution estimation of building characteristics with diffusion models for urban energy modeling

Understanding current energy consumption behavior in communities is critical for informing future energy use decisions and enabling efficient energy management. Urban energy models, which are used to simulate these energy use patterns, require large datasets with detailed building characteristics for accurate outcomes. However, such detailed characteristics at the individual building level are often unknown and costly to acquire, or unavailable. Through this work, we propose using a generative modeling approach to generate realistic building attributes to fill in the data gaps and finally provide complete characteristics as inputs to energy models. Our model learns complex, building-level patterns from training on a large-scale residential building stock model containing 2.2 million buildings. We employ a tabular diffusion-based framework that is designed to handle heterogeneous (discrete and continuous) features in tabular building data, such as occupancy, floor area, heating, cooling, and other equipment details. We develop a capability for conditional diffusion, enabling the imputation of missing building characteristics conditioned on known attributes. We conduct a comprehensive validation of our conditional diffusion model, firstly by comparing the generated conditional distributions against the underlying data distribution, and secondly, by performing a case study for a Baltimore residential region, showing the practical utility of our approach. Our work is one of the first to demonstrate the potential of generative modeling to accelerate building energy modeling workflows.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Pricing Strategy of Electric Vehicle Aggregators Based on Locational Marginal Price to Minimize Photovoltaic (PV) Curtailment

The global climate crisis demands urgent action to mitigate global warming. Using renewable energy sources, such as solar and wind power, for electricity generation is crucial. This shift from centralized to distributed power systems, however, brings challenges, including voltage fluctuations and renewable energy curtailment. The rapid growth of the electric vehicle (EV) industry adds complexity, increasing overall electricity demand and straining the power supply during peak charging times. This paper proposes a scheduling strategy for EV aggregators to reduce renewable energy curtailment and stabilize grid operation by strategically scheduling EV charging. Using Multi -Agent Transport Simulation (MATSim), a traffic simulation tool, EV driving data in Denver, Colorado, USA, were modeled. The EV aggregator adjusts charging fees based on locational marginal prices, encouraging EVs to charge at different stations according to pricing. Simulations on an IEEE 33-bus system with distributed energy resources and EV charging stations validate the proposed algorithm, demonstrating its effectiveness in reducing curtailment by 12.55% and stabilizing grid operation.

33 ADVANCED PROPULSION SYSTEMS

Preventive Power Outage Estimation Based on a Novel Scenario Clustering Strategy

The increasing occurrence of extreme weather events is challenging power grid operation. For extreme weather events, the system operator is responsible for estimating the power outages and scheduling the restoration resources. This paper proposes an outage evaluation framework to identify the possible unserved load profiles, vulnerable areas, and mobile energy adequacy. The outputs of an outage prediction model tool are used to generate numerous faulted line scenarios. Next, each scenario's nodal unserved load profile is obtained by solving a three-phase restoration model that considers repair crews and mobile energy resources (MERs). Then, a novel scenario clustering strategy is developed to cluster the unserved load profiles into multiple representative profiles which the system operator can focus on. Finally, case studies on a distribution system evaluate the damage caused by an extreme weather event and verify the effectiveness of the proposed scenario clustering strategy.

MATHEMATICS AND COMPUTING,POWER TRANSMISSION AND D

MSD CoP Webinar: Quantum Computing Futures through a Multisector Lens

Context: This webinar featured two presentations examining quantum computing and its complex implications across the energy, water, and materials sectors. Olivier Ezratty introduced quantum computing, its anticipated applications and added value, and the hardware required to support these systems. He also discussed their energy demands and the role of the Quantum Energy Initiative in developing an interdisciplinary research field focused on these challenges. David McCollum then explored the opportunities and multisectoral challenges associated with next-generation, quantum-accelerated data centers, including their potential energy and resource impacts and the infrastructure chokepoints that could emerge. Together, the presentations emphasized the need for long-term planning and cross-cutting research collaboration as quantum computing technologies continue to develop. Presenters: Olivier Ezratty (Quantum Energy Initiative); David McCollum (Oak Ridge National Laboratory) Moderator: Patrick M. Reed (MSD CoP Facilitation Team); Gokul Iyer (Pacific Northwest National Laboratory) This webinar was held on: July 9th, 2026 from 1:00–2:30 PM EDT.

Quantum Computing

Particle Handling in Particle-Based Pumped Thermal Energy Storage

A particle-based pumped thermal electricity storage system stores high-temperature heat (~1000 degrees C) in low-cost silica sand and generates power through an efficient power cycle. Central to this system is a counterflow direct-contact gas/particle fluidized-bed heat exchanger, which can significantly improve the heat exchange process due to the large heat transfer surface area of particles. To showcase a lab-scale 10- to 20-kWe heat exchange process with particles heating up to 300 degrees C, a comprehensive hydrodynamic analysis of the fluidization condition inside the heat exchanger was conducted. The heat exchanger was designed to target for heat exchange process of 10-20 kW and accommodate an air mass flow rate of 0.3-0.7 kg/s. The fluidization condition was set to maintain stable bubbling fluidization, thereby maximizing the particle-to-air heat transfer. An air distributor was designed to equally distribute air over the bed, which can avoid defluidized zones in the heat exchanger. Additionally, particle handling systems including L-valves, screw conveyors, and pneumatic conveyors were developed for the prototype heat exchanger, efficiently conveying high-temperature particles at 0.2-0.5 kg/s. This work lays the foundation for scaling up the system and integrating it into larger energy storage applications, demonstrating its potential for efficient, high-temperature thermal energy storage and power generation.

25 ENERGY STORAGE

Machine Learning for Optimized Polarization at Jefferson Lab

Polarized cryo-targets and polarized photon beams are widely used in experiments at Jefferson Lab. Traditional methods for maintaining the optimal polarization involve manual adjustments throughout data taking by human shift takers. This may introduce some level of inconsistency simply due to the wide variety of experience and expertise of the shift takers themselves. Implementing machine learning-based control systems can improve the stability of the polarization without relying on human intervention. The cryo-target polarization is influenced by temperature, microwave energy, the distribution of paramagnetic radicals, as well as operational conditions including the radiation dose. Diamond radiators are used to generate linearly polarized photons from a primary electron beam. The energy spectrum of these photons can drift over time due to changes in the primary electron beam conditions and diamond degradation. As a first step towards automating the continuous optimization and control processes, uncertainty aware surrogate models have been developed to predict the polarization based on historical data. This talk will provide an overview of the use cases and models developed, highlighting the collaboration between data scientists and physicists at Jefferson Lab.

Jeske, Torri [Thomas Jefferson National Accelerato

Directional, joule per steradian THz pulses from multi-joule laser irradiation of wires

We report on THz pulses with energy flux exceeding 2.5 J/sr and high directionality, generated from picosecond, joule laser irradiation of microwires. The impact of wire diameter, length, and laser irradiation orientation is explored with the irradiation of 160 μm diameter, 750 μm, sharpened wires at the dull base found to produce the highest energy and shortest wavelength THz pulses among the targets tested. A traveling wave antenna combined with coherent transition radiation model is developed to explain the emission pattern, pulse energy, and spectrum seen.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

SCORE (Synthesis of COnsists as Rolling Energy microgrids) (Final Technical Report)

The SCORE toolset is an open source, web-based application to assess the impact of new powering technologies on railroad performance, specifically technologies capable of both putting power into the rail (motive force) and taking power from the rail (regeneration). SCORE’s primary goal is generate trade studies to analyze different powering and train make-up options to minimize energy usage and greenhouse gas generation. At the core of generating these trade spaces is calculating the optimal powering policy for the train given the makeup of the train, the route, and time constraints. This paper presents details on the algorithms used in SCORE to compute this powering policies that is fast and accurate, discusses its implementation in an Energy-Longitudinal Train Dynamics (E-LTD) model, compares it to naïve approaches, and demonstrates its use across a variety of train/route pairs.

24 POWER TRANSMISSION AND DISTRIBUTION

Region-Specific Merchant Hydrogen Market Assessment and Techno-Economic Assessment of Electrolytic Hydrogen Generation: Cooperative Research and Development Final Report, CRADA Number CRD-18-00751

Utilities need to recover value from baseload and some renewable assets even when the electricity is curtailed. The declining cost of renewables (particularly solar), the persistently low-cost of natural gas, and the declining electricity demand, have all worked to lower the price of electricity. Furthermore, the baseload assets have a high turndown cost, which is not reflected in the low market electricity prices. One option for utilizing the curtailed electricity is hydrogen generation. One important aspect of this project will be to provide a “go/no-go” recommendation on the economic feasibility of pursuing hydrogen generation vs. other markets that could offtake curtailed electricity or nuclear steam. This project will specifically assess the opportunities for hydrogen production and use in the service territories of Southern Company Services (SCS), Exelon SBC, and Xcel Energy. Each utility partner represents a different mix of generation fleets: Exelon has significant nuclear assets, Xcel is primarily renewables (wind) with some nuclear, and SCS represents both a renewables fleet and a heavily baseload fleet, which includes significant nuclear. The Contractors will conduct the study of hydrogen market opportunities by first considering the approximate electricity demand and price profiles for the year, and power generation capacity that can be used to produce hydrogen. Therefore, a profile for hydrogen generation will also be developed to better understand the quantity and timing of hydrogen production. Once the hydrogen production schedule is estimated, hydrogen storage requirements can be determined. This effort will provide sufficient information to make a go/no-go decision on moving ahead with a detailed regional case study for hydrogen production in any of the three utility areas.

08 HYDROGEN

GODEEEP-hydro: Historical and projected power system ready hydropower data for the United States

Hydropower is a critical electricity resource in the United States which, in addition to low-cost electricity generation, provides valuable ancillary grid services, and supports the integration of nondispatchable weather-dependent resources (e.g., wind and solar). Despite its value to the grid, there are very few comprehensive datasets available from which to study both historical and future impacts of climate, weather driven energy droughts, and integration of other weather driven generation. In this paper, we present a hydropower generation dataset covering 1,452 hydroelectric plants in the contiguous U.S. The dataset contains monthly and weekly hydropower generation estimates for both historical (1982–2019) and future (2020–2099) periods which includes 4 future climate scenarios. In addition, this dataset provides weekly and monthly constraints such as minimum and maximum power which are particularly useful in power system models which are used to study grid reliability, transmission planning and capacity expansion.

13 HYDRO ENERGY

Hypochlorite Redox Chemistry Enables High-Voltage and High-Power Saltwater Batteries

Saltwater batteries (SWBs) are promising alternatives to lithium-ion batteries for large-scale stationary energy storage. However, the performance of conventional oxygen redox-based saltwater battery systems is often constrained by sluggish oxygen evolution and reduction reactions (OER/ORR) at the cathode, leading to low voltage efficiency and limited power density. Here, OER and ORR are replaced by hypochlorite-based redox reactions through the introduction of sodium hypochlorite into saltwater. Operando pH and dissolved oxygen measurements confirm that OER and ORR are minimized and that hypochlorite redox reactions dominate the cathode behavior. Owing to the higher operating potential and faster reaction kinetics, the hypochlorite-redox-based SWBs delivers a higher discharge voltage of 3.3 V and reduced charge-discharge voltage polarization to 0.66 V. Further improvement is achieved by adjusting the saltwater pH to near-neutral conditions, increasing the discharge voltage to 3.5 V and more than doubling the peak power. The hypochlorite redox environment also exhibits chemical stability with key cell components, including the solid electrolyte and cathode current collectors. Operation of series-connected cells and cells employing hard carbon anodes demonstrates scalability and compatibility with alternative anode materials. These results provide a strong foundation for next-generation SWBs targeting large-scale stationary energy storage applications.

Go, Wooseok [ORNL]

Development of physics-consistent conditional diffusion model to overcome data scarcity in critical heat flux

Deep generative modeling provides a powerful pathway to overcome data scarcity in energy-related applications where experimental data are often limited. By learning the underlying probability distribution of the training dataset, deep generative models, such as the diffusion model, can generate high-fidelity synthetic samples that statistically resemble the training data. Such synthetic data generation can significantly enrich the size and diversity of the available training data, and more importantly, improve the robustness of downstream machine learning models in predictive tasks. The objective of this paper is to investigate the effectiveness of diffusion models for overcoming data scarcity in nuclear energy applications. By leveraging a public dataset on critical heat flux which covers a wide range of commercial nuclear reactor operational conditions, we developed a diffusion model that can generate an arbitrary amount of synthetic samples. Since a vanilla diffusion model can only generate samples randomly, we also developed a conditional diffusion model capable of generating targeted critical heat flux data under user-specified thermal-hydraulic conditions. The performance of the diffusion model was evaluated based on its ability to capture empirical feature distributions and pair-wise correlations, as well as to maintain physical consistency. The results showed that both the diffusion model and conditional diffusion model can successfully generate realistic and physics-consistent critical heat flux data. Furthermore, uncertainty quantification results demonstrate that the conditional diffusion model is highly effective in augmenting critical heat flux data while maintaining acceptable levels of uncertainty.

22 GENERAL STUDIES OF NUCLEAR REACTORS

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI